Plan Review Details - Permit 14050254
| Plan Review Stops For Permit 14050254 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2014-07-30 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2014-07-30 |
Time |
07:01 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-07-30 |
Time |
05:47 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2014-07-01 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2014-07-01 |
Time |
17:15 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-07-01 |
Time |
15:39 |
Sent To |
|
|
| Notes |
| 2014-07-01 15:57:30 | BUILDING PLAN REVIEW | | | PERMIT:14050254 | | | ADD: 109 S OLIVE AVE | | | CONT: TRI-R CONSTRUCTION | | | TEL: (772)336-6444 | | | | | | 2010 FLORIDA BUILDING CODE W | | | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | | | 2010 EXISTING BUILDING CODE LEVEL II 701.3 | | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | | | 2ND REVIEW | | | DATE: TUES. JULY 01 /2014 | | | ACTION: DENIED | | | | | | NOTE: FAILED!!!!! DID NOT HAPPEN, CONTRACTOR IS TO | | | INSERT NEW SHEETS INTO PLANS & REMOVE OLD SHEETS BEFORE | | | RESUBMITTAL!!!!!!!!!!! WHEN RESUBMITTING PLANS PLEASE | | | INDICATE THE REVISION & REMOVE & REPLACE ANY PAGES AS | | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | | EXPEDITE YOUR PERMIT. | | | | | | 1) 2ND REQUEST, THE LIFE SAFETY SHEET A-0.00 | | | 1A) CODE ANALYSIS INDICATES THIS BUILDING TO A TYPE V - | | | ASSUMED, PLEASE PROVIDE THE HEIGHT OF THE BUILDING, | | | THIS SPACE BEING TWO FLOORS AND HOW MANY ADDITIONAL | | | FLOORS ONE OR TWO. PLEASE REVIEW TABLE 503, IT APPEARS | | | IF THIS IS A 3 STORY BUILDING EITHER A III-B OR V-A OR | | | IF A 4 STORY A III-A. TAKING INTO ACCOUNT A STORY | | | INCREASE FOR FIRE SPRINKLERS. THE DESIGNER OF RECORD | | | WILL HAVE TO DECIDE IF THIS BUILDING WAS DESIGNED TO A | | | VA OR VB. NOT JUST A V UNDER THE 2001 FBC THERE WAS A | | | TYPE V WHEN THE 2004 FBC AND SINCE THERE WAS NO LONGER | | | ABUILDING TYPE VI, THE TYPE V IS CURRENTLY CONSIDERED A | | | IIIA, SEE THE 2007 CODE COMMENTARY FIGURE 600 FOR | | | CONSTRUCTION TYPE COMPARISONS. | | | | | | 1B) SHEET A101 NOW HAS A NEW 1 HOUR CHASE, IT APPEARS | | | TO BE IN THE STAIRWELL TO THE OTHER TENANTS. PLEASE | | | PROVIDE ON THE PLANS THE UL LISTING U415 SYSTEM A SINCE | | | THE INSPECTORS WILL NEED THE COMPONENTS OF THE ASSEMBLY | | | TO BE ABLE TO ACCOMPLISH THEIR INSPECTIONS. FBC-B 708.4 | | | AND 708.5 CONTINUITY. 708.8 PENETRATIONS. | | | | | | 1C) SHEET A-1.01 DOES HAVE A WALL TAG S2 WALL TYPE | | | IDENTIFYING FIRE RATED WALLS. NONE OF THE TENANT | | | SEPERATION WALLS ARE IDENTIFIED WITH THIS WALL TAG. FBC | | | 709.1.6. | | | | | | 1D )2ND REQUEST. ONLY NEW SHEET IS P3 NOT FOUND ON THIS | | | SHEET, CONTRACTOR FAILED TO COLATE PLANS INTO ONE SET | | | OF PLANS. THE TENANT SEPARATION WALL WITHIN THE LADIES | | | RESTROOM WILL HAVE VENTING THAT WILL PETRUDE OUT OF THE | | | FIRE RATED WALL, WHAT TYPE OF FIRE STOPPING DESIGN IS | | | TO BE SUBMITTED FOR THROUGH PENETRATIONS, 2010 FBC-B | | | 713.4.1.1. | | | | | | 1E) COMPLIED. | | | | | | 1F) SEMI COMPLIED MISSING THE NEW A4.01 AS INDICATED IN | | | RESPONSE. | | | 2) SHEET A-1.01: | | | 2A-J)COMPLIED. | | | | | | 3) 2ND REQUEST, SHEET M-4 INDICATES THE USE OF WALL | | | LOUVERS AND PRE-MANUFACTURED A/C STANDS, PLEAS PROVIDE | | | COMPLIANCE WITH : FLORIDA DEPARTMENT OF COMMUNITY | | | AFFAIRS RULE 9N-3 NOV. 01/ 2010 (31) SUB-CATEGORY OF | | | PRODUCTS OR CONSTRUCTION SYSTEMS THAT WILL REQUIRE | | | PRODUCT APPROVALS: | | | (31)(C) WALL LOUVERS | | | (G) PRE-ENGINEERED A/C STANDS | | | | | | 4) 2ND REQUEST, 2010 FBC 107.3.4.1 PRODUCT APPROVALS. | | | THOSE PRODUCTS WHICH ARE REGULATED BY THE DCA RULE | | | 9N-03 SHALL BE REVIEWED AND APPROVED IN WRITING BY THE | | | DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR | | | JURISDICTIONAL APPROVAL. | | | FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR | | | SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS, | | | SHOP DRAWINGS ETC.. | | | | | | 5) 2ND REQUEST, PLANS, SPECIFICATIONS, REPORTS OR OTHER | | | DOCUMENTS PREPARED BY THE DESIGN PROFESSIONAL AND BEING | | | FILED FOR PUBLIC RECORD SHALL HAVE THE SIGNATURE AND | | | SEAL OF THE DESIGN PROFESSIONAL AFFIXED TO THE | | | DOCUMENT. | | | FL ADMIN CODE 61G15-23.002 ENGINEERS | | | | | | PLEASE PROVIDE THE WIND DESIGN CRITERIA, PRESSURES FOR | | | THE WALL LOUVER & ROOFTOP A/C STAND. | | | 2010 FBC-B 1609.1.1 DETERMINATION OF WIND DESIGN- | | | CHAPTER 6 OF ASCE 7-10. | | | 1609.3 BASIC WIND SPEED FIGURE 1609.A-C | | | 1609.3 WIND SPEED CONVERSION | | | 5.1) THE BASIC WIND SPEED, VU, SHALL BE DETERMINED IN | | | ACCORDANCE WITH 1609.3.1 & ASCE 7-10 | | | | | | 5.2) AN IMPORTANCE FACTOR, FIGURE 1609 A-C, ASCE 7-10. | | | | | | 5.3) AN EXPOSURE CATEGORY SHALL BE DETERMINED IN | | | ACCORDANCE WITH 1609.4 & ASCE 7-10 | | | | | | 5.4) A HEIGHT AND EXPOSURE ADJUSTMENT COEFFICIENT, * | | | SHALL BE DETERMINED FROM TABLE 1609.7.2. ASCE 7-10. | | | | | | 5.5) COMPONENTS & CLADDING PRESSURES POSITVE & NEGATIVE | | | TABLE 1609.2(2) . | | | | | | 6) SHEET M-1 NOTE # 3 INDICATES TO RUN THE REFRIGARANT | | | LINES THROUGH CHASE TO ROOF. THERE IS NO DETAILS WITHIN | | | THE PLANS INDICATING HOW THIS CHASE WILL BE BUILT,AND | | | ACHIEVE FIRE RATINGS IN COMPLIANCE WITH 2010 FBC-B | | | 713.4.1 FIRE-RESISTANCE-RATED ASSEMBLIES. | | | | | | 6A) COMPLIED SEE SHEET M-5. | | | PENETRATIONS OF THE FIRE-RESISTANCE-RATED FLOOR, | | | FLOOR/CEILING ASSEMBLY OR THE CEILING MEMBRANE OF A | | | ROOF/CEILING ASSEMBLY SHALL COMPLY WITH SECTIONS | | | 713.4.1.1 THROUGH 713.4.1.4. | | | | | | 7) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION | | | & REMOVE & REPLACE ANY PAGES AS NECESSARY. A | | | TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT | | | NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE THE | | | CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2014-05-23 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2014-05-23 |
Time |
15:58 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-05-23 |
Time |
07:30 |
Sent To |
|
|
| Notes |
| 2014-05-23 13:28:08 | BUILDING PLAN REVIEW | | | PERMIT:14050254 | | | ADD: 109 S OLIVE AVE | | | CONT: TRI-R CONSTRUCTION | | | TEL: (772)336-6444 | | | | | | 2010 FLORIDA BUILDING CODE W | | | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | | | 2010 EXISTING BUILDING CODE LEVEL II 701.3 | | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | | | 1ST REVIEW | | | DATE: FRIDAY MAY 23/2014 | | | ACTION: DENIED | | | | | | 1) THE LIFE SAFETY SHEET A-0.00 | | | 1A) CODE ANALYSIS INDICATES THIS BUILDING TO A TYPE V - | | | ASSUMED, PLEASE PROVIDE THE HEIGHT OF THE BUILDING, | | | THIS SPACE BEING TWO FLOORS AND HOW MANY ADDITIONAL | | | FLOORS ONE OR TWO. PLEASE REVIEW TABLE 503, IT APPEARS | | | IF THIS IS A 3 STORY BUILDING EITHER A III-B OR V-A OR | | | IF A 4 STORY A III-A. TAKING INTO ACCOUNT A STORY | | | INCREASE FOR FIRE SPRINKLERS. | | | | | | 1B) SHEET A101 NOW HAS A NEW 1 HOUR CHASE, IT APPEARS | | | TO BE IN THE STAIRWELL TO THE OTHER TENANTS. PLEASE | | | PROVIDE ON THE PLANS THE UL LISTING U415 SYSTEM A SINCE | | | THE INSPECTORS WILL NEED THE COMPONENTS OF THE ASSEMBLY | | | TO BE ABLE TO ACCOMPLISH THEIR INSPECTIONS. FBC-B 708.4 | | | AND 708.5 CONTINUITY. 708.8 PENETRATIONS. | | | | | | 1C) SHEET A-1.01 DOES HAVE A WALL TAG S2 WALL TYPE | | | IDENTIFYING FIRE RATED WALLS. NONE OF THE TENANT | | | SEPERATION WALLS ARE IDENTIFIED WITH THIS WALL TAG. FBC | | | 709.1.6. | | | | | | 1D )2ND REQUEST. ONLY NEW SHEET IS P3 NOT FOUND ON THIS | | | SHEET, CONTRACTOR FAILED TO COLATE PLANS INTO ONE SET | | | OF PLANS. THE TENANT SEPARATION WALL WITHIN THE LADIES | | | RESTROOM WILL HAVE VENTING THAT WILL PETRUDE OUT OF THE | | | FIRE RATED WALL, WHAT TYPE OF FIRE STOPPING DESIGN IS | | | TO BE SUBMITTED FOR THROUGH PENETRATIONS, 2010 FBC-B | | | 713.4.1.1. | | | | | | 1E) COMPLIED. | | | | | | 1F) SEMI COMPLIED MISSING THE NEW A4.01 AS INDICATED IN | | | RESPONSE. | | | 2) SHEET A-1.01: | | | 2A-J)COMPLIED. | | | | | | 3) 2ND REQUEST, SHEET M-4 INDICATES THE USE OF WALL | | | LOUVERS AND PRE-MANUFACTURED A/C STANDS, PLEAS PROVIDE | | | COMPLIANCE WITH : FLORIDA DEPARTMENT OF COMMUNITY | | | AFFAIRS RULE 9N-3 NOV. 01/ 2010 (31) SUB-CATEGORY OF | | | PRODUCTS OR CONSTRUCTION SYSTEMS THAT WILL REQUIRE | | | PRODUCT APPROVALS: | | | (31)(C) WALL LOUVERS | | | (G) PRE-ENGINEERED A/C STANDS | | | | | | 4) 2ND REQUEST, 2010 FBC 107.3.4.1 PRODUCT APPROVALS. | | | THOSE PRODUCTS WHICH ARE REGULATED BY THE DCA RULE | | | 9N-03 SHALL BE REVIEWED AND APPROVED IN WRITING BY THE | | | DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR | | | JURISDICTIONAL APPROVAL. | | | FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR | | | SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS, | | | SHOP DRAWINGS ETC.. | | | | | | 5) 2ND REQUEST, PLANS, SPECIFICATIONS, REPORTS OR OTHER | | | DOCUMENTS PREPARED BY THE DESIGN PROFESSIONAL AND BEING | | | FILED FOR PUBLIC RECORD SHALL HAVE THE SIGNATURE AND | | | SEAL OF THE DESIGN PROFESSIONAL AFFIXED TO THE | | | DOCUMENT. | | | FL ADMIN CODE 61G15-23.002 ENGINEERS | | | | | | PLEASE PROVIDE THE WIND DESIGN CRITERIA, PRESSURES FOR | | | THE WALL LOUVER & ROOFTOP A/C STAND. | | | 2010 FBC-B 1609.1.1 DETERMINATION OF WIND DESIGN- | | | CHAPTER 6 OF ASCE 7-10. | | | 1609.3 BASIC WIND SPEED FIGURE 1609.A-C | | | 1609.3 WIND SPEED CONVERSION | | | 5.1) THE BASIC WIND SPEED, VU, SHALL BE DETERMINED IN | | | ACCORDANCE WITH 1609.3.1 & ASCE 7-10 | | | | | | 5.2) AN IMPORTANCE FACTOR, FIGURE 1609 A-C, ASCE 7-10. | | | | | | 5.3) AN EXPOSURE CATEGORY SHALL BE DETERMINED IN | | | ACCORDANCE WITH 1609.4 & ASCE 7-10 | | | | | | 5.4) A HEIGHT AND EXPOSURE ADJUSTMENT COEFFICIENT, * | | | SHALL BE DETERMINED FROM TABLE 1609.7.2. ASCE 7-10. | | | | | | 5.5) COMPONENTS & CLADDING PRESSURES POSITVE & NEGATIVE | | | TABLE 1609.2(2) . | | | | | | 6) SHEET M-1 NOTE # 3 INDICATES TO RUN THE REFRIGARANT | | | LINES THROUGH CHASE TO ROOF. THERE IS NO DETAILS WITHIN | | | THE PLANS INDICATING HOW THIS CHASE WILL BE BUILT,AND | | | ACHIEVE FIRE RATINGS IN COMPLIANCE WITH 2010 FBC-B | | | 713.4.1 FIRE-RESISTANCE-RATED ASSEMBLIES. | | | | | | 6A) COMPLIED SEE SHEET M-5. | | | PENETRATIONS OF THE FIRE-RESISTANCE-RATED FLOOR, | | | FLOOR/CEILING ASSEMBLY OR THE CEILING MEMBRANE OF A | | | ROOF/CEILING ASSEMBLY SHALL COMPLY WITH SECTIONS | | | 713.4.1.1 THROUGH 713.4.1.4. | | | | | | 7) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION | | | & REMOVE & REPLACE ANY PAGES AS NECESSARY. A | | | TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT | | | NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE THE | | | CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2014-07-28 |
|
|
Cont ID |
|
| Sent By |
dhayes |
Date |
2014-07-26 |
Time |
07:37 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
2014-07-26 |
Time |
13:11 |
Sent To |
|
|
| Notes |
| 2014-07-26 14:06:55 | DATE: 7/26/2014 | | | PROJECT: SHOUTE KARAOKE | | | PERMIT#: 14050254 | | | CODE: 2008 EDITION OF THE NEC | | | 2010 EDITION OF THE FBC | | | 2010 WPB AMENDMENTS TO THE FBC, CHAPTER 1, | | | ADMINISTRATION, 2012 FBC SUPPLEMENTS. | | | | | | 4TH ELECTRICAL PLAN REVIEW | | | ACTION: PROVISO | | | | | | A SEPARATE ELECTRICAL PERMIT APPLICATION SHALL BE | | | SUBMITTED ACCOMPANIED BY SHOP DRAWINGS, EQUIPMENT | | | SUBMITTALS, PRODUCT APPROVALS FOR ALL OF THE FOLLOWING | | | AS APPLICABLE: | | | GENERATOR, SIGNAGE, NETWORK, DATA/COM, FIRE ALARM, | | | SECURITY, CCTV, AND AUDIO/VIDEO. | | | | | | DAVID HAYES, ELECTRICAL PLANS EXAMINER, PX3421, | | | 561-805-6717 OR [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2014-07-16 |
|
|
Cont ID |
|
| Sent By |
dhayes |
Date |
2014-07-16 |
Time |
11:00 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
2014-07-15 |
Time |
14:11 |
Sent To |
|
|
| Notes |
| 2014-07-16 11:00:23 | DATE: 7/14/2014 | | | PROJECT: SHOUTE KARAOKE | | | PERMIT#: 14050254 | | | CODE: 2008 EDITION OF THE NEC | | | 2010 EDITION OF THE FBC | | | 2010 WPB AMENDMENTS TO THE FBC, CHAPTER 1, | | | ADMINISTRATION, 2012 FBC SUPPLEMENTS. | | | | | | 1ST ELECTRICAL PLAN REVIEW | | | ACTION: DENIED | | | | | | 1) INDICATE CIRCUITRY WITH MEANS OF DISCONNECT ON THE | | | FLOOR PLAN AND ON A PANELS SCHEDULE FOR EF-1, AND THE | | | MOTORIZED DAMPERS FOR MECHANICAL SYSTEMS. | | | A DISCONNECTING MEANS FOR THE MOTOR SHALL BE LOCATED IN | | | SIGHT FROM THE MOTOR LOCATION AND THE DRIVEN MACHINERY | | | LOCATION. 430.102(B)(1), .FBC 107.2.1.3, NEC 440.11 | | | | | | 2) PROVIIDE MANUFACTURERS'S DATA SHEET FOR ELEVATOR | | | LIFT TO INDICATE CODE COMPLIANCE WITH NEC110.3, 110.58, | | | 430.102(B)(1), 620, FBC 107.2.1.3, | | | | | | 3) PROVIDE MANUFACTURERS'S DATA SHEET FOR LED RIBBON | | | LIGHTING AND ASSOCIATED REMOTE TRANSFORMERS. NEC110.3, | | | 110.58, 411 | | | | | | 4) PROVIDE SAFETY LABELING FOR ARC FLASH PROTECTION FOR | | | THE PANEL BOARDS AND MAIN DISCONNECTING MEANS. NEC | | | 110.16, 110.22 | | | | | | 5) FIRE ALARM SYSTEM NOTES SHALL INDICATE COMPLIANCE | | | WITH NFPA 72 WITH REGARDS TO: (A) SMOKE DETECTOR | | | PLACEMENT NEAR THE ELEVATOR LOBBY AND ELEVATOR RECAL. | | | (B) AUXILIARY AUDIO SYSTEMS SHALL BE AUTOMATICALLY | | | MUTED BY THE FIRE ALARM CONTROL PANEL IN THE EVENT OF | | | AN ALARM CONDITION. | | | | | | 6) PLEASE INDICATE COMPLIANCE WITH THE FBC - ENERGY FOR | | | INTERIOR AND EXTERIOR LIGHTING CONTROL. SEE THE | | | FOLLOWING CODE REFERENCE: | | | | | | ELECTRICAL POWER AND LIGHTING SYSTEMS. (MANDATORY) | | | SECTION 505 | | | 505.2.2 AUTOMATIC LIGHTING SHUTOFF. | | | BUILDINGS LARGER THAN 5,000 SQUARE FEET (465 M2) SHALL | | | BE EQUIPPED WITH AN AUTOMATIC CONTROL DEVICE TO SHUT | | | OFF LIGHTING IN THOSE AREAS. THIS AUTOMATIC CONTROL | | | DEVICE SHALL FUNCTION ON EITHER: | | | 1. A SCHEDULED BASIS, USING TIME-OF-DAY, WITH AN | | | INDEPENDENT PROGRAM SCHEDULE THAT CONTROLS THE INTERIOR | | | LIGHTING IN AREAS THAT DO NOT EXCEED 25,000 SQUARE FEET | | | (2323 M2) AND ARE NOT MORE THAN ONE FLOOR; OR | | | 2. AN OCCUPANT SENSOR THAT SHALL TURN LIGHTING OFF | | | WITHIN 30 MINUTES OF AN OCCUPANT LEAVING A SPACE; OR | | | 3. A SIGNAL FROM ANOTHER CONTROL OR ALARM SYSTEM THAT | | | INDICATES THE AREA IS UNOCCUPIED. | | | | | | 505.2.2.1 OCCUPANT OVERRIDE. | | | WHERE AN AUTOMATIC TIME SWITCH CONTROL DEVICE IS | | | INSTALLED TO COMPLY WITH SECTION 505.2.2, ITEM 1, IT | | | SHALL INCORPORATE AN OVERRIDE SWITCHING DEVICE THAT: | | | 1. IS READILY ACCESSIBLE. | | | 2. IS LOCATED SO THAT A PERSON USING THE DEVICE CAN SEE | | | THE LIGHTS OR THE AREA CONTROLLED BY THAT SWITCH, OR SO | | | THAT THE AREA BEING LIT IS ANNUNCIATED. | | | 3. IS MANUALLY OPERATED BY AN OCCUPANT OR AUTOMATICALLY | | | BY SENSING AN OCCUPANT. | | | 4.MEETS THE REQUIREMENTS OF SECTION 505.2.1.2. | | | | | | 505.2.4 EXTERIOR LIGHTING CONTROLS. | | | LIGHTING FOR ALL EXTERIOR APPLICATIONS NOT EXEMPTED IN | | | SECTION 505.1 SHALL HAVE AUTOMATIC CONTROLS CAPABLE OF | | | TURNING OFF EXTERIOR LIGHTING WHEN SUFFICIENT DAYLIGHT | | | IS AVAILABLE OR WHEN THE LIGHTING IS NOT REQUIRED | | | DURING NIGHTTIME HOURS. LIGHTING NOT DESIGNATED FOR | | | DUSK-TO-DAWN OPERATION SHALL BE CONTROLLED BY EITHER A | | | COMBINATION OF A PHOTOSENSOR AND A TIME SWITCH, OR AN | | | ASTRONOMICAL TIME SWITCH. LIGHTING DESIGNATED FOR | | | DUSK-TO-DAWN OPERATION SHALL BE CONTROLLED BY AN | | | ASTRONOMICAL TIME SWITCH OR PHOTOSENSOR. ALL TIME | | | SWITCHES SHALL BE CAPABLE OF RETAINING PROGRAMMING AND | | | THE TIME SETTING DURING LOSS OF POWER FOR A PERIOD OF | | | AT LEAST 10 HOURS. | | | | | | A SEPARATE ELECTRICAL PERMIT APPLICATION SHALL BE | | | SUBMITTED ACCOMPANIED BY SHOP DRAWINGS, EQUIPMENT | | | SUBMITTALS, PRODUCT APPROVALS FOR ALL OF THE FOLLOWING: | | | NETWORK, DATA/COM, FIRE ALARM, SECURITY, CCTV, AND | | | AUDIO/ VIDEO WORK. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. SEE LINK: HTTP://WPB.ORG/DEVELOPMENT | | | /WPCONTENT/UPLOADS/SITES/33/2013/09/APPLICATION_RESUBMI | | | TTAL_FORM_04132010.PDF. | | | ADDITIONALLY, INSERT CORRECTED PAGES INTO SUBMITTAL AND | | | LEAVE THE PREVIOUSLY REVIEWED SHEETS. | | | | | | DAVID HAYES, ELECTRICAL PLANS EXAMINER, PX3421, | | | 561-805-6717 OR [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2014-06-19 |
|
|
Cont ID |
|
| Sent By |
albarran |
Date |
2014-06-19 |
Time |
16:24 |
Rev Time |
0.00 |
| Received By |
albarran |
Date |
2014-06-19 |
Time |
11:38 |
Sent To |
|
|
| Notes |
| 2014-06-19 16:52:19 | THESE PLANS FAILED THE SECOND ELECTRICAL REVIEW AS | | | INDICATED BELOW: | | | A) PAGE A-0.00 | | | 1. UNDER THE BOX "APPLICABLE CODES" REFERENCE TO THE | | | NON-EXISTENT 2010 NEC IS BEING MADE. CORRECT THAT TO | | | THE CURRENTLY ADOPTED CODE: NEC 2008 | | | 2. THERE IS NO WALL SCHEDULE OR LEGEND TO DESCRIBE THE | | | DIFFERENT TYPES OF WALLS DRAWN. | | | B) PAGE A-1.01 | | | 1. DESCRIBE THE SHADED AREA BETWEEN STORAGE ROOM 010 | | | AND ROOM 006. IS THAT A CHASE, A VOID OR A SOLID | | | COLUMN? | | | C) PAGE A-2.01 | | | 1. WHAT IS SUPPOSED TO BE AN OPEN AREA IN THE REFLECTED | | | CEILING PLAN SHOW LIGHTING FIXTURES (D). THEY SHOULD BE | | | ON THE SECOND FLOOR CEILING INSTEAD. | | | D) PAGE E-2.1 | | | 1. THE LOCATION OF THE EXISTING PANEL "B" IS NOT | | | CLEARLY INDICATED. IT APPEARS TO BE INSIDE THE AREA IN | | | WHICH I INQUIRED ABOVE. IF IS IS ON THE OTHER SIDE OF | | | THE WALL BEHIND THE DOOR, THERE DOES NOT APPEAR TO BE | | | ENOUGH LIGHTING THERE.. | | | 2. WHAT HAPPENED TO THE FACP FROM STAIRWELL 011 AS | | | SHOWN ON THE PREVIOUS DRAWING? | | | E) PAGE E-4.1 | | | 1. PANEL "B" CKT 14 SHALL BE MARKED IN RED AND BE | | | MECHANICALLY PROTECTED. | | | 2. CARE SHOULD BE TAKEN ON HOW THE TRANSITION TO | | | ALUMINUM CONDUIT IS MADE TO AVOID GALVANIC REACTION. | | | | | | THESE PLANS WERE REVIEWED BY MIKE ALBARRAN, ELECTRICAL | | | PLANS EXAMINER | | | YOU ARE WELCOME TO REVIEW STATUS OR COMMENTS AT THE | | | FOLLOWING LINK: | | | HTTP://ONESTOPSHOP.WPBGOV.COM/EGOVPLUS/PERMIT/PERM_STAT | | | US.ASPX | | | ENTER YOUR PERMIT NUMBER (SEE SUBJECT LINE OF THIS | | | EMAIL FOR YOUR PERMIT #), CLICK ON THE PERMIT NUMBER, | | | AND THEN GO TO "PLAN REVIEWS" TO SEE YOUR COMMENTS (TAB | | | ABOVE THE SECOND PERMIT INFORMATION). | | | AFTER ISSUANCE, PLEASE CHECK YOUR PLAN CAREFULLY FOR | | | COMPLIANCE WITH ANY REDLINES, NOTES, PROVISOS, OR OTHER | | | PERMIT CONDITIONS. | | | FOR FURTHER ASSISTANCE, PLEASE FEEL FREE TO CONTACT ME | | | AT (561) 805-6718 OR EMAIL: [email protected], OR | | | DAVID HAYES AT: [email protected], OR (561) 805-6717. | | | THANK YOU. | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2014-05-22 |
|
|
Cont ID |
|
| Sent By |
albarran |
Date |
2014-05-22 |
Time |
17:20 |
Rev Time |
0.00 |
| Received By |
albarran |
Date |
2014-05-22 |
Time |
15:30 |
Sent To |
|
|
| Notes |
| 2014-05-22 17:19:42 | FAILED FIRST ELECTRICAL REVIEW AS FOLLOWS: | | | | | | 1. NEC 110.26(D) REQUIRES THAT THEREE BE PROPER | | | ILLUMINATION IN THE AREA ABOUT THE ELECTRICAL PANELS, | | | THIS BEING BOTH PANEL "B" AND THE FACP | | | 2. NEC 600.5 REQUIRES A DEDICATED SIGN OUTLET BY EACH | | | ENTRY DOOR. | | | 3. MISSING EMERGENCY LIGHTING IN THE BATHROOMS AS PER | | | FBC-B1006.2.2 | | | 4. STAIR 013 IS MISSING THE EMERGENCY LIGHT ON THE | | | FIRST FLR. | | | 5. ELECTRIC ROOM IS MISSING AN EMERGENCY LIGHT | | | 6. AS PER THE SUBMITTED PLANS, THER IS NOT SUFFICIENT | | | LIGHTING IN THE STAIRWAYS | | | 7. THOUGH A SEPARATE PLAN & SET OF SHOP DRAWINGS IS | | | REQUIRED FOR THE FIRE ALARM, THE SUBMITTED PLANS SHOW | | | THE FACP IN THE 011 STAIRWELL, THEREFORE A DEDICATED 20 | | | AMP CIRCUIT FOR THE FIRE ALARM SHALL BE PROVIDED. | | | 8. VERIFY THE FEEDER FOR CU1; TAKING INTO ACCOUNT ANY | | | APPLICABLE VOLTAGE DROP AND EXPOSURE DERATIONS. | | | 9 IF PANEL RP1` IS A SINGLE PHASE 120/240, WHY DOES THE | | | FEEDER SHOW FOUR 4/0 CONDUCTORS PLUS THE GRD. | | | | | | THESE PLANS WERE REVIEWED BY MIKE ALBARRAN, ELECTRICAL | | | PLANS EXAMINER | | | YOU ARE WELCOME TO REVIEW STATUS OR COMMENTS AT THE | | | FOLLOWING LINK: | | | | | | HTTP://ONESTOPSHOP.WPBGOV.COM/EGOVPLUS/PERMIT/PERM_STAT | | | US.ASPX | | | | | | ENTER YOUR PERMIT NUMBER (SEE SUBJECT LINE OF THIS | | | EMAIL FOR YOUR PERMIT #), CLICK ON THE PERMIT NUMBER, | | | AND THEN GO TO "PLAN REVIEWS" TO SEE YOUR COMMENTS (TAB | | | ABOVE THE SECOND PERMIT INFORMATION). | | | AFTER ISSUANCE, PLEASE CHECK YOUR PLAN CAREFULLY FOR | | | COMPLIANCE WITH ANY REDLINES, NOTES, PROVISOS, OR OTHER | | | PERMIT CONDITIONS. | | | FOR FURTHER ASSISTANCE, PLEASE FEEL FREE TO CONTACT ME. | | | I CAN BE REACHED AT 561-805-6718 OR | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2014-05-19 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2014-05-19 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2014-05-19 |
Time |
12:08 |
Sent To |
|
|
| Notes |
| 2014-05-19 12:27:01 | THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC, | | | FIRE MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | THE LIFE SAFETY SYSTEMS, FIRE ALARM AND/OR FIRE | | | SPRINKLER SHALL REMAIN ACTIVE THROUGHOUT THE | | | CONSTRUCTION PERIOD. | | | | | | ANY AND ALL WORK ON THE FIRE ALARM AND FIRE SPRINKLER | | | SYSTEMS SHALL BE DONE UNDER SEPARATE SHOP DRAWINGS AND | | | BY CERTIFIED LIFE SAFETY CONTRACTORS. | | | | | | ANY TIME THAT WORK ON THE LIFE SAFETY SYSTEMS, | | | SPRINKLER AND/OR FIRE ALARM, EXCEEDS 4 HOURS, A FIRE | | | WATCH SHALL BE IMPLEMENTED AND MAINTAINED UNTIL FULL | | | AND COMPLETE PROTECTION IS RETURNED. |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2014-07-01 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2014-07-01 |
Time |
17:20 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-07-01 |
Time |
17:20 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2014-05-23 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2014-05-23 |
Time |
16:01 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-05-23 |
Time |
15:59 |
Sent To |
|
|
| Notes |
| 2014-05-23 16:01:35 | FUEL GAS PLAN REVIEW | | | PERMIT:14050254 | | | ADD: 109 S OLIVE AVE | | | CONT: TRI-R CONSTRUCTION | | | TEL: (772)336-6444 | | | | | | 2010 FLORIDA BUILDING CODE W | | | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | | | 2010 EXISTING BUILDING CODE LEVEL II 701.3 | | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | | | 1ST REVIEW | | | DATE: FRIDAY MAY 23/2014 | | | ACTION: DENIED | | | | | | INFORMATION SHALL BE SHOWN ON ALL GAS DRAWINGS | | | SUBMITTED FOR PERMITTING IN THE CITY OF WEST PALM | | | BEACH: | | | | | | 1. SUBMIT MANUFACTURE SHEETS FOR ALL GAS EQUIPMENT TO | | | VERIFY COMPLIANCE WITH STANDARDS NFPA 54, NFPA 58, AND | | | FBC-2010 FUEL GAS SEC. 402.2 | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2014-07-30 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2014-07-30 |
Time |
07:02 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-07-24 |
Time |
07:02 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2014-07-30 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2014-07-24 |
Time |
07:03 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-06-13 |
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2014-05-27 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2014-05-27 |
Time |
15:03 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2014-05-07 |
Time |
10:02 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
N |
Date |
2014-05-23 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2014-05-23 |
Time |
15:58 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-05-23 |
Time |
15:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2014-07-28 |
|
|
Cont ID |
|
| Sent By |
jsaez |
Date |
2014-07-28 |
Time |
09:15 |
Rev Time |
0.00 |
| Received By |
jsaez |
Date |
2014-07-28 |
Time |
09:14 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2014-05-27 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2014-05-27 |
Time |
15:03 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2014-05-27 |
Time |
13:29 |
Sent To |
|
|
| Notes |
| 2014-05-27 15:03:03 | PLAN DENIED | | | 1) PROVIDE A ENGINEER DETAIL ON THE A/C STAND OR CURB | | | TIE DOWN TO ROOF PER SECTION 301.12 WIND RESISTANCE. | | | 2010 FBC (M) (PROVIDE THE TYPE AND SIZE OF SCREW OR | | | ANCHOR USED) | | | 2) REFER TO SECTION 304.11 GUARDS.2010 FBC (M) | | | 3) REFER TO SECTION 401.3 ENERGY PERFORMANCE | | | CARD 2010 FLORIDA ENERGY CODE. | | | PLAN REVIEW BY HAROLD MOSER | | | [email protected] | | | OFFICE 561-805-6732 | | | FAX 561-805-6676 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2014-07-30 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2014-07-30 |
Time |
06:46 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-07-30 |
Time |
06:00 |
Sent To |
|
|
| Notes |
| 2014-07-30 06:46:55 | PLUMBING PLAN REVIEW | | | PERMIT: 14050254 | | | ADD: 109 N OLIVE AVE | | | CONT: TRI-R CONSTRUCTION | | | TEL: (772)336-6444 | | | | | | 2010 FLORIDA BUILDING CODE W | | | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | | | 2010 EXISTING BUILDING CODE LEVEL II 701.3 | | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | | | 3RD REVIEW | | | DATE: WED. JULY 30/ 2014 | | | | | | ACTION: PLUMBING PROVISO | | | | | | THE PLANS (P-3) INDICATES A NEW GREASE INTERCEPTOR. | | | THIS INTERCEPTOR IS TO BE PERMITTED UNDER A SEPARATE. | | | THE NEW GREASE INTERCEPTOR IS TO BE SIZED USING UNDER | | | THE 2010 FBC-PLUMBING CODE SECTION 1003.3.4 TOTAL FLOW | | | RATE WITH RATE OF FLOW CONTROL (1003.3.4.2) OR CONCRETE | | | VAULT TYPE INTERCEPTORS (TABLE 1003.5.1). | | | | | | THE CITY FOG INSPECTORS (FATS, OILS & GREASE) MONITOR | | | ALL GREASE INTERCEPTORS TO VERIFY COMPLIANCE WITH THE | | | CITY?S MUNI CODE SEC. 90-126. PROHIBITIONS AND | | | LIMITATIONS OF DISCHARGE.(7) MINERAL OIL IN EXCESS OF | | | 50 MG/L OR ANIMAL/VEGETABLE FATS, WAX, GREASE, OR OILS | | | IN EXCESS OF 100 MG/L, WHETHER EMULSIFIED OR NOT; OR | | | SUBSTANCES WHICH MAY SOLIDIFY OR BECOME VISCOUS AT | | | TEMPERATURES LOWER THAN OR EQUAL TO 150 DEGREES | | | FAHRENHEIT (65.56 DEGREES CELSIUS). | | | | | | IF THIS AMOUNT OF FATS, OILS OR GREASE IS EXCEEDED | | | DURING INSPECTIONS THE REQUIRED MAINTENANCE & PUMP-OUT | | | SCHEDULE WILL BE INCREASED TO KEEP IN COMPLIANCE WITH | | | THE CITY'S MUNICIPAL CODE OF ORDINANCES. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2014-07-01 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2014-07-01 |
Time |
17:40 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2014-07-01 17:27:03 | PLUMBING PLAN REVIEW | | | PERMIT:14050254 | | | ADD: 109 S OLIVE AVE | | | CONT: TRI-R CONSTRUCTION | | | TEL: (772)336-6444 | | | | | | 2010 FLORIDA BUILDING CODE W | | | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | | | 2010 EXISTING BUILDING CODE LEVEL II 701.3 | | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | | | 1ST REVIEW | | | DATE: TUES. JULY 01/2014 | | | ACTION: PLUMBING PROVISO: | | | | | | | | | 1) SHEET P-1 NOTE # 3 INDICATES THE REUSE OF THE | | | EXISTING GREASE INTERCEPTOR. PLEASE CONTACT WEST PALM | | | BEACH FOG (FATS, OILS & GREASE) INSPECTORS TO VERIFY | | | THE EXISITNG INTERCEPTOR SIZE AS WELL AS CONDITION TO | | | SEE IF THE EXISITNG INTERCEPTOR CAN BE REUSED. THE | | | CONCRETE TYPE VAULT INTERCEPTORS ARE TO BE LOCATED ON | | | THE EXTERIOR OF THE BUILDING. | | | CONTACT INFO: JOCELYN BROWN 822-2170 PUBLIC UTILITIES | | | DEPARTMENT. | | | | | | 2) IF THE EXISITNG GREASE INTERCEPTOR CAN BE REUSED | | | PLEASE PROVIDE THE CALCULATIONS TO VERIFY THE GREASE | | | INTERCEPTOR IS SIZED PROPERLY. FOR THE HYDROCEMICAL | | | TYPE OF GREASE INTERCEPTORS THERE ARE VARIOUS METHODS | | | FOR SIZING. FOR THE CONCRETE TYPE VAULT INTERCEPTORS | | | SEE SIZING TABLE 1003.5.1 2010 FBC-P SIZING FORMULA FOR | | | RESTAURANTS. | | | | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2014-05-23 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2014-05-23 |
Time |
18:31 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-05-23 |
Time |
15:58 |
Sent To |
|
|
| Notes |
| 2014-05-23 16:13:32 | PLUMBING PLAN REVIEW | | | PERMIT:14050254 | | | ADD: 109 S OLIVE AVE | | | CONT: TRI-R CONSTRUCTION | | | TEL: (772)336-6444 | | | | | | 2010 FLORIDA BUILDING CODE W | | | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | | | 2010 EXISTING BUILDING CODE LEVEL II 701.3 | | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | | | 1ST REVIEW | | | DATE: FRIDAY MAY 23/2014 | | | ACTION: DENIED | | | | | | 1) 2010 FBC-P ) 315.1 REQUIREMENTS. PUBLIC FOOD SERVICE | | | ESTABLISHMENTS AND FOOD ESTABLISHMENTS, AS DEFINED IN | | | CHAPTER 381 FLORIDA STATUTES, CHAPTER 500 FLORIDA | | | STATUTES AND CHAPTER 509 FLORIDA STATUTES, SHALL COMPLY | | | WITH THE APPLICABLE CODE REQUIREMENTS FOUND IN THE | | | FLORIDA BUILDING CODE, BUILDING, CHAPTER 4, SPECIAL | | | DETAILED REQUIREMENTS BASED ON USE AND OCCUPANCY. | | | PLEASE SEE DBPR WEBSITE FOR ADDITIONAL INFO: | | | HTTP://WWW.MYFLORIDALICENSE.COM/DBPR/HR/LICENSING/ | | | PLANREVIEWINDEX.HTML | | | | | | 2) SHEET A-0.00 & A-1.00 : THE UPCOMING COMMENT WILL OR | | | WILL NOT BE RELEVENT DEPENDING ON HOW THIS PROJECT IS | | | LOOKED AT. UNDER THE HEADING OF RESTAURANT THERE ARE | | | MORE THAN ADEQUITE FIXTURES, THE 2010 FBC-PLUMBING CODE | | | SECTION 403.5 DOES LOOK AT REQUIRED FIXTURES NOT IS | | | PROVIDED, UNDER THE HEADING OF RESTARAUNT THE FIXTURE | | | COUNT IS ABOVE THE CODE REQUIREMENTS. | | | | | | THE PROBLEM WE ARE HAVING IS UNDER A RESTAURANT YOU | | | HAVE A COMMERCIAL KITCHEN FOR FIXING MEALS, THERE IS NO | | | EQUIPMENT FOR THE HEATING AND PREPARING OF FOOD. THE | | | SECOND ISSUE WITH THE CLASSIFICATION OF A RESTAURANT | | | ,THERE IS NO TABLES AND CHAIRS THAT WOULD BE ASSOCIATED | | | WITH A RESTAURANT. WE DO NOT SEE ANY TABLE AND CHAIRS | | | ON THE LIFE SAFETY PLANS FOR FLOOR PLANS FOR THE FIRST | | | OR SECOND FLOOR. | | | | | | IF THIS PROJECT IS REVIEWED UNDER THE NIGHTCLUB USAGE, | | | NOT REQUIRING A FULL BLOWN KITCHEN, NOT REQUIRING TABLE | | | AND CHAIRS THE REQUIRED 40 SQ FT/ OCC GOES TO 75 SQ FT/ | | | OCC ALMOST DOUBLING THE REQUIRED FIXTURE COUNT, THEN | | | WITH THE COMBINED REQUIRED WATER CLOSET COUNT FOR MENS | | | & LADIES RESTROOMS A SEPERATE UNISEX RESTROOM WILL BE | | | REQUIRED. OUR PROBLEM IS THE PLANS APPEAR TO BE A | | | NIGHTCLUB SETTING AND NOT THE RESTAURANT DECLARED BY | | | THE DESIGN PROFESSIONAL. | | | | | | 2A)IF CONSIDERED A NIGHTCLUB: CODE ANALYSIS UNDER THE | | | HEADING USE & OCCUPANCY INDICATES THIS TO BE AN A2 | | | OCCUPANCY / RESTARAUNT. THE PLUMBING FIXTURE COUNT ALSO | | | REFLECTS | | | THE REQUIRED FIXTURES FOR A RESTARAUNT USE. THE | | | REQUIRED WATER CLOSET COUNT OF 2 REQUIRED WATER CLOSETS | | | ARE PROVIDED WITH A 3RD ACCESSIBLE RESTROOM FOR EACH | | | THE MENS AND WOMENS RESTROOMS. THE ISSUE IS THERE IS NO | | | UNISEX RESTROOM AS REQUIRED BY 2010 FL ACC CODE 403.5. | | | | | | 2010 FL ACC CODE SECTION :2010 FL ACC CODE 403.1.2 | | | FAMILY OR ASSISTED-USE TOILET AND BATH FIXTURES. | | | FIXTURES LOCATED WITHIN FAMILY OR ASSISTED-USE TOILET | | | AND BATHING ROOMS REQUIRED BY THE FLORIDA BUILDING | | | CODE, ACCESSIBILITY ARE PERMITTED TO BE INCLUDED IN THE | | | NUMBER OF REQUIRED FIXTURES FOR EITHER THE MALE OR | | | FEMALE OCCUPANTS IN ASSEMBLY AND MERCANTILE | | | OCCUPANCIES. THIS IS A GENERAL CODE ARTICLE THAT ALLOWS | | | THE FAMILY OR ASSITED- USE RESTROOMS TO BE COUNTED IN | | | EITHER OR MALE OR FEMALE FIXTURE COUNT. | | | | | | SECTION 403.5 IS A SPECIFIC CODE ARTILE THAT DEALS ONLY | | | WITH ASSEMBLY & MERCANTILE OCCUPANCIES. 403.5 UNISEX | | | TOILET AND BATHING ROOMS. IN ASSEMBLY AND MERCANTILE | | | OCCUPANCIES, AN ACCESSIBLE UNISEX TOILET ROOM SHALL BE | | | PROVIDED WHERE AN AGGREGATE OF SIX OR MORE MALE AND | | | FEMALE WATER CLOSETS IS REQUIRED, AGAIN UNDER A | | | NIGHTCLUB SETTING. | | | WITH THE SINGLE MENS ACCESIBLE RESTROOM THE PLANS ARE | | | MISSING THE REQUIRED UNISEX RESTROOM REQUIRED BY THE | | | 2010 FL ACCESSIBILITY CODE UNDER THE NIGHTCLUB SETTING. | | | | | | 3) SHEET P-1 NOTE # 3 INDICATES THE REUSE OF THE | | | EXISTING GREASE INTERCEPTOR. PLEASE CONTACT WEST PALM | | | BEACH FOG (FATS, OILS & GREASE) INSPECTORS TO VERIFY | | | THE EXISITNG INTERCEPTOR SIZE AS WELL AS CONDITION TO | | | SEE IF THE EXISITNG INTERCEPTOR CAN BE REUSED. THE | | | CONCRETE TYPE VAULT INTERCEPTORS ARE TO BE LOCATED ON | | | THE EXTERIOR OF THE BUILDING. | | | CONTACT INFO: JOCELYN BROWN 822-2170 PUBLIC UTILITIES | | | DEPARTMENT. | | | | | | 4) IF THE EXISITNG GREASE INTERCEPTOR CAN BE REUSED | | | PLEASE PROVIDE THE CALCULATIONS TO VERIFY THE GREASE | | | INTERCEPTOR IS SIZED PROPERLY. FOR THE HYDROCEMICAL | | | TYPE OF GREASE INTERCEPTORS THERE ARE VARIOUS METHODS | | | FOR SIZING. FOR THE CONCRETE TYPE VAULT INTERCEPTORS | | | SEE SIZING TABLE 1003.5.1 2010 FBC-P SIZING FORMULA FOR | | | RESTAURANTS. | | | | | | 5) SHEET P-3.0 IN THE LADIES RESTROOM THE WATER CLOSETS | | | NEED TO BE EITHER INDIVIDUALLY VENTED OR A CIRCUIT VENT | | | AS DRAWN IT APPEARS TO BE A VET VENT SYSTEM, | | | WET VENT SYSSTEMS ARE TO BE USED ON 1 & 2 FAMILY | | | RESIDENCE. | | | INFORMAL INTERPRETATION BOAF & FL DEPART COMMUNITY | | | AFFAIRS | | | DATE: MON APR 13 2009 | | | REPORT: 6090 | | | CODE: PLUMBING CODE YEAR: 2007 | | | SECTION: 909 | | | QUESTION: | | | IS IT THE INTENT OF THE FLORIDA BUILDING CODE - | | | PLUMBING SECTION 909 TO ALLOW A URINAL TO WET VENT A | | | SINGLE COMMERCIAL | | | WATER CLOSET OR TO DRAIN INTO THAT WATER CLOSET?S | | | INDIVIDUAL VENT? | | | COMMENT: | | | ANSWER: | | | NO. ONLY FIXTURES IN BATHROOM GROUPS AS DEFINED IN | | | FLORIDA BUILDING CODE - PLUMBING CHAPTER 2 ARE | | | PERMITTED TO | | | CONNECT TO THE WET VENT. ANY ADDITIONAL FIXTURES MUST | | | DISCHARGE DOWNSTREAM OF THE WET VENT. | | | COMMENTARY: | | | A URINAL IS NOT INCLUDED IN THE DEFINITION OF A | | | BATHROOM GROUP. | | | NOTICE: | | | THE BUILDING OFFICIALS ASSOCIATION OF FLORIDA, IN | | | COOPERATION WITH THE FLORIDA BUILDING COMMISSION, THE | | | FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS, | | | ICC, AND INDUSTRY AND PROFESSIONAL EXPERTS OFFER THIS | | | INTERPRETATION OF THE FLORIDA BUILDING CODE IN THE | | | INTEREST OF CONSISTENCY IN THEIR APPLICATION | | | STATEWIDE. THIS INTERPRETATION IS INFORMAL, NON-BINDING | | | AND SUBJECT TO ACCEPTANCE AND APPROVAL BY THE LOCAL | | | BUILDING OFFICIAL. | | | | | | 6) THE SAME SITUATION OCCURS WITHIN THE MENS RESTROOM | | | WITH THE WATER CLOSETS, THEY SHOULD BE EITHER | | | INDIVIDUALLY VENTED. 2010 FBC- P 907.1. | | | | | | 7) THE PLANS DO NOT SHOW ANY VENTING THA TIES BACK INTO | | | THE BUILDING TO THE OUTDOORS. 2010 FBC-P 903.1. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | | REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL | | | LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH | | | A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE | | | SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE | | | FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR | | | YOUR ANTICIPATED COOPERATION. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2014-06-27 |
|
|
Cont ID |
|
| Sent By |
aaponte |
Date |
2014-06-27 |
Time |
12:55 |
Rev Time |
0.00 |
| Received By |
aaponte |
Date |
2014-06-27 |
Time |
12:55 |
Sent To |
|
|
| Notes |
| 2014-06-27 12:56:18 | PROVISO: ESTABLISHMENT SHALL OPERATE AS A RESTAURANT. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2014-06-11 |
|
|
Cont ID |
|
| Sent By |
aaponte |
Date |
2014-06-11 |
Time |
09:51 |
Rev Time |
0.00 |
| Received By |
aaponte |
Date |
2014-06-11 |
Time |
09:50 |
Sent To |
|
|
| Notes |
| 2014-06-11 09:59:52 | 1.BASED ON THE INFORMATION PROVIDED IN THE SUBMITTAL, | | | THE PROPOSED ESTABLISHMENT IS CLASSIFIED AS A BAR. | | | BASED ON THE REQUIREMENTS OF CHAPTER 6 OF THE CITY | | | CODE, THE LOCATION IS NOT AUTHORIZED FOR THE SALE OF | | | ALCOHOL, AND THE PROPOSED KARAOKE BAR DOES NOT MEET THE | | | REQUIREMENTS OF A BONA FIDE RESTAURANT. IF THE SALE OF | | | ALCOHOL IS NOT PROPOSED IN THE ESTABLISHMENT PLEASE | | | INCLUDE A NOTE IN THE DRAWINGS STATING SUCH CONDITION. | | | 2. IF THE SALE OF ALCOHOL IS INTENDED, THE | | | ESTABLISHMENT SHALL COMPLY WITH THE REQUIREMENTS OF A | | | BONA FIDE RESTAURANT IN SECTION 6-1 OF THE CITY CODE | | | (CHAPTER 6, SECTION 6-1). | | | 3. PLEASE INCLUDE A FACADE OF THE EXISTING BUILDING, | | | AND INDICATE ANY PROPOSED CHANGES TO THE ELEVATION. | | | FOR ADDITIONAL INFORMATION PLEASE CONTACT ANA MARIA | | | APONTE AT 561-822-1439. |
|
|
|