| Plan Review Stops For Permit 14050164 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2014-05-28 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-05-28 |
Time |
14:31 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2014-05-28 |
Time |
14:31 |
Sent To |
|
|
| Notes |
| 2014-05-28 14:33:00 | PROVISO ITEMS HAVE BEEN ADDRESSED IN THE REVISED PLANS. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2014-05-24 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-05-24 |
Time |
10:13 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2014-05-24 |
Time |
09:26 |
Sent To |
|
|
| Notes |
| 2014-05-24 10:31:01 | APPROVED WITH EXCEPTIONS. | | | | | | 1) SUBMIT TWO COPIES OF THE PRODUCT APPROVALS FOR THE | | | FRENCH DOORS IN THE LIVING ROOM THAT WAS PREVIOUSLY THE | | | GARAGE AREA. DCA RULE 9N-3 | | | | | | 2) EXISTING WINDOWS IN FORMER GARAGE AREA ARE REQUIRED | | | TO HAVE LARGE MISSILE IMPACT PROTECTION. FBC R301.2.1.2 | | | | | | 3) THE BEDROOM IS REQUIRED TO HAVE AN EMERGENCY ESCAPE | | | AND RESCUE OPENING THAT COMPLIES WITH FBC R310. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2014-05-09 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-05-09 |
Time |
10:54 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2014-05-06 |
Time |
18:23 |
Sent To |
|
|
| Notes |
| 2014-05-08 13:28:40 | 2010 FBC | | | | | | DENIED BY BUILDING | | | | | | 1) THE PALM BEACH COUNTY PROPERTY APPRAISER RECORDS | | | SHOW THAT THIS STRUCTURE IS A ONE STORY GARAGE | | | APARTMENT. THE CITY OF WEST PALM BEACH DOES NOT HAVE | | | ANY RECORDS THAT INDICATE THAT THE 16' X 22' GARAGE | | | PORTION WAS CONVERTED TO LIVING AREA WITH THE REQUIRED | | | PERMITS AND INSPECTIONS. IN ORDER TO BRING THE GUEST | | | HOUSE INTO COMPLIANCE, THE AREA THAT WAS CONVERTED FROM | | | GARAGE TO LIVING SPACE WILL HAVE TO BE MADE CODE | | | COMPLIANT OR RETURNED TO A GARAGE. THE FOLLOWING REVIEW | | | WILL BE WHAT IS REQUIRED TO BRING THE CONVERTED GARAGE | | | INTO COMPLIANCE. 2010 FBC EXISTING BUILDING, 2010 FBC | | | RESIDENTIAL AND 2008 NEC | | | | | | 2) GENERAL NOTE #9 ON SHEET GH1 NEEDS TO BE CORRECTED. | | | THE WINDSPEED IS 170 MPH VULT , THE EXPOSURE CATEGORY | | | IS D AND THE APPLICABLE BUILDING CODE IS THE 2010 | | | FLORIDA BUILDING CODE. | | | | | | 3) UNLESS YOU CAN SHOW THAT THE EXTERIOR FRENCH DOOR | | | AND THE WINDOWS IN THE CONVERTED GARAGE WERE PERMITTED | | | AND INSPECTED, PRODUCT APPROVALS WILL NEED TO BE | | | SUBMITTED AS REQUIRED BY DCA RULE 9N-3. | | | | | | 4) SHOW COMPLIANCE WITH FBCR 301.2.1.2 WHICH REQUIRES | | | THE WINDOWS AND DOORS WITH GLAZED AREAS TO PROTECTED | | | FROM LARGE MISSILE IMPACT. IMPACT RATED EXTERIOR DOORS | | | AND WINDOWS OR STORM PANELS WILL BE REQUIRED. | | | | | | 5) PRODUCT APPROVALS WILL BE REQUIRED FOR THE STORM | | | PANELS. A KEY PLAN AND INSTALLATION SCHEDULE THAT | | | PROVIDES COMPLETE INSTALLATION DETAILS IS REQUIRED. DCA | | | RULE 9N-3, CITY AMENDMENTS 107.2.1 AND 107.2.1.3 | | | | | | 6) THE CONTINUOUS LOAD PATH FROM THE ROOF THE THE | | | FOUNDATION WILL NEED TO BE EVALUATED. IF IT IS NOT CODE | | | COMPLIANT, ADDITION STRAPS AND CONNECTORS MAY BE | | | REQUIRED. FBC R301.1 | | | | | | 7) SMOKE ALARMS AS REQUIRED FOR NEW DWELLINGS WILL BE | | | REQUIRED. FBC R314.3.1 | | | | | | 8)THE ELECTRICAL SYSTEM WILL NEED TO BE MADE CODE | | | COMPLIANT. SEE ELECTRICAL REVIEW NOTES. 2008 NEC | | | | | | 9) BECAUSE THE STRUCTURE IS HISTORIC PER FS 267.021, IT | | | IS EXEMPT FROM THE 2010 FBC ENERGY CODE PER SECTION | | | 101.4.2. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2014-05-28 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-05-28 |
Time |
14:33 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2014-05-28 |
Time |
14:33 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2014-05-24 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-05-24 |
Time |
10:31 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2014-05-24 |
Time |
09:26 |
Sent To |
|
|
| Notes |
| 2014-05-24 10:39:47 | 2010 FBC / 2008 NEC | | | | | | DENIED | | | | | | 1) THE ELECTRIC PLAN DID NOT PRINT PROPERLY. PARTS OF | | | IT ARE FADED OUT AND ARE NOT ACCEPTABLE FOR COPYING | | | INTO THE BUILDING DEPARTMENT'S PUBLIC RECORDS. CITY | | | AMENDMENTS 107.2.1.4 | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2014-05-09 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-05-09 |
Time |
11:43 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2014-05-06 |
Time |
18:23 |
Sent To |
|
|
| Notes |
| 2014-05-09 11:37:03 | 2010 FBC / 2008 NEC | | | | | | DENIED BY ELECTRICAL | | | | | | 1) SHOW THE LOCATION OF THE EXISTING METER AND CIRCUIT | | | BREAKER PANEL. CITY AMENDMENTS 107.2.1 AND NEC | | | | | | 2) SUBMIT LOAD CALCULATIONS AND A PANEL SCHEDULE. NEC | | | 220.40 AND NEC 408.4 | | | | | | 3) SHOW COMPLIANCE WITH NEC 210.11 (C) (3) FOR THE | | | REQUIRED 20 AMP BATHROOM CIRCUIT. | | | | | | 4) SHOW COMPLIANCE WITH NEC 210.8 (A) (1), (2) AND (3) | | | FOR GROUND-FAULT CIRCUIT-INTERRUPTER PROTECTION. | | | | | | 5) SHOW COMPLIANCE WITH NEC 210.12 FOR ARC-FAULT | | | PROTECTION. | | | | | | 6) SHOW COMPLIANCE WITH NEC 406.11 FOR TAMPER-RESISTANT | | | RECEPTACLES. | | | | | | 7) SHOW COMPLIANCE WITH NEC 210.52 (A) (1) FOR | | | RECEPTACLE SPACING. | | | | | | 8) SHOW COMPLIANCE WITH NEC 210.52 (D) AND (E) (1) FOR | | | BATHROOM AND OUTDOOR RECEPTACLE OUTLETS. | | | | | | 9) SHOW COMPLIANCE WITH NEC 210.70 (A) (1), (2) AND (3) | | | FOR REQUIRED INTERIOR AND OUTDOOR LIGHTING OUTLETS. | | | | | | 10) THE NAME AND LICENSE NUMBER OF THE PERSON | | | RESPONSIBLE FOR THE DESIGN IS REQUIRED ON THE | | | ELECTRICAL PLANS. CITY AMENDMENTS 107.2.1 | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | [email protected] |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2014-05-24 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-05-24 |
Time |
10:41 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2014-05-23 |
Time |
11:28 |
Sent To |
|
|
| Notes |
| 2014-05-23 11:28:31 | TO RMCDOUGA DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2014-05-09 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-05-09 |
Time |
11:43 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2014-05-06 |
Time |
16:13 |
Sent To |
|
|
| Notes |
| 2014-05-06 16:14:21 | EXPEDITED!!! INCOMING SENT TO ROBERT MC DOUGALS DESK . | | | JW |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
3 |
Status |
P |
Date |
2014-05-30 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2014-05-30 |
Time |
11:24 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2014-05-30 |
Time |
11:24 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
F |
Date |
2014-05-24 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-05-24 |
Time |
10:40 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2014-05-24 |
Time |
10:40 |
Sent To |
|
|
| Notes |
| 2014-05-24 10:41:03 | SEE PREVIOUS COMMENT. |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2014-05-08 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-05-08 |
Time |
13:07 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2014-05-08 |
Time |
13:07 |
Sent To |
|
|
| Notes |
| 2014-05-08 13:13:33 | ONE SET OF PLANS IS REQUIRED TO BE SIGNED OUT AND TAKEN | | | TO PALM BEACH COUNTY FOR AN IMPACT FEE REVIEW. THE | | | PLANS WITH THE IMPACT FEE REVIEW ON THEM AND A COPY OF | | | THE IMPACT FEE RECEIPT ARE TO BE SUBMITTED TO THE CITY | | | BUILDING DEPARTMENT BEFORE THE BUILDING PERMIT CAN BE | | | ISSUED. PBC IMPACT FEES PHONE # 561-233-5025 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2014-05-06 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-05-06 |
Time |
18:26 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2014-05-06 |
Time |
18:26 |
Sent To |
|
|
| Notes |
| 2014-05-06 18:27:42 | NO MECHANICAL WORK IS SHOWN ON THE PLANS. A SEPARATE | | | PERMIT, APPLICATION AND REVIEW IS REQUIRED. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2014-05-06 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-05-06 |
Time |
18:25 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2014-05-06 |
Time |
18:25 |
Sent To |
|
|
| Notes |
| 2014-05-06 18:28:12 | A PLUMBING SUB-PERMIT IS REQUIRED. |
|
|