| Plan Review Stops For Permit 14050112 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2014-09-15 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-09-15 |
Time |
17:46 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2014-09-15 |
Time |
14:57 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2014-06-05 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-06-05 |
Time |
07:45 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2014-06-04 |
Time |
16:24 |
Sent To |
|
|
| Notes |
| 2014-06-05 07:16:21 | 2010 FBC | | | | | | DENIED BY BUILDING | | | | | | 1) THE VALUE OF $25,000.00 SPECIFIED ON THE PERMIT | | | APPLICATION IS LOW FOR THE SCOPE OF WORK SHOWN ON THE | | | PLANS. PER CITY AMENDMENTS 109.3 FOR PERMITTING | | | PURPOSES VALUATION OF BUILDINGS AND SYSTEMS SHALL BE | | | THE TOTAL REPLACEMENT VALUE TO INCLUDE STRUCTURAL, | | | ELECTRIC, PLUMBING, MECHANICAL, INTERIOR FINISH, | | | RELATIVE SITE WORK, ARCHITECTURAL AND DESIGN FEES, | | | OVERHEAD AND PROFIT. | | | | | | 2) THE ENERGY FORM 402 - 2010 CAN NOT BE USED FOR THIS | | | PROJECT. THE GLASS AREA IN THE ADDITION EXCEEDS 20 | | | PERCENT OF THE CONDITIONED FLOOR AREA. SEE NOTE 1 UNDER | | | GENERAL INSTRUCTIONS ON THE FORM. | | | | | | 3) SUBMIT TWO COPIES OF ICC EVALUATION REPORT ESR 1826 | | | FOR THE ICYNENE FOAM INSULATION. FBC R316 | | | | | | 4) PLAN SHEET SP-1 SPECIFIES THE STRUCTURE IS LOCATED | | | IN EXPOSURE "C" AND ON SHEET S-000 IT IS SPECIFIED AS | | | EXPOSURE "D". PLEASE CORRECT. CITY AMENDMENTS 107.2.1 | | | AND FBC R301.2.1.4.3 | | | | | | 5) SUBMIT TWO SETS OF SIGNED AND SEALED RAS 117 | | | CALCULATIONS FOR ENHANCED FASTENING OF THE TAMKO | | | MODIFIED ROOF SYSTEM ON PAGE 12 OF NOA NO. 12-0716.18. | | | FBC R301.2.1 | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2014-06-05 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-06-05 |
Time |
08:20 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2014-06-05 |
Time |
07:16 |
Sent To |
|
|
| Notes |
| 2014-06-05 08:20:54 | RED-LINED PLANS. |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2014-09-15 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-09-15 |
Time |
16:13 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2014-09-15 |
Time |
14:57 |
Sent To |
|
|
| Notes |
| 2014-09-15 17:56:42 | A GAS SUB-PERMIT IS REQUIRED. THE GAS RISER DIAGRAM WAS | | | INCLUDED IN THE PLANS. |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2014-06-04 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-06-04 |
Time |
17:32 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2014-06-04 |
Time |
16:52 |
Sent To |
|
|
| Notes |
| 2014-06-04 17:32:52 | 2010 FBC | | | | | | GAS REVIEW DENIED | | | | | | 1) THE 3/4" SCHEDULE 40 METALLIC PIPE SPECIFIED FOR THE | | | 2 LB SYSTEM FROM THE METER TO THE FIRST BRANCH IS TOO | | | SMALL. THE CAPACITY FROM TABLE 402.4(3) FOR 3/4" PIPE | | | AT 100 FEET IS 934 MBH AND THE REQUIRED LOAD IS 945 MBH | | | PER THE PLAN ON SHEET P-2.1. PLEASE CORRECT. FBC FUEL | | | GAS 402.1 | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | [email protected] |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
P |
Date |
2014-05-05 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2014-05-05 |
Time |
09:22 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2014-05-05 |
Time |
09:22 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2014-09-15 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-09-15 |
Time |
17:46 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2014-08-29 |
Time |
12:13 |
Sent To |
|
|
| Notes |
| 2014-08-30 12:13:44 | SENT TO R MCDOUGAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2014-06-05 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-06-05 |
Time |
08:20 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2014-05-05 |
Time |
17:18 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
3 |
Status |
P |
Date |
2014-09-17 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-09-17 |
Time |
16:12 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2014-09-17 |
Time |
16:12 |
Sent To |
|
|
| Notes |
| 2014-09-17 16:13:20 | MU 2014-20652 |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
F |
Date |
2014-09-15 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-09-15 |
Time |
14:58 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2014-09-15 |
Time |
14:58 |
Sent To |
|
|
| Notes |
| 2014-09-15 14:59:48 | IMPACT FEES | | | | | | PLANS REQUIRE REVIEW BY THE PBC IMPACT FEE OFFICE. CALL | | | 233-5025. UPON APPROVAL, YOU MAY CHECK OUT ONE PLAN AND | | | TAKE TO THAT OFFICE FOR REVIEW. PLEASE RETURNED STAMPED | | | WITH A COPY OF RECEIPT AS APPLICABLE. | | | | | | |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2014-06-04 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-06-04 |
Time |
16:26 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2014-06-04 |
Time |
16:26 |
Sent To |
|
|
| Notes |
| 2014-06-04 16:27:26 | IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY, PLANS STAMPED BY THEM AND | | | COPY OF RECEIPT SUBMITTED TO CITY OF | | | WEST PALM BEACH BUILDING DEPARTMENT, | | | BEFORE A BUILDING PERMIT CAN BE ISSUED. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2014-09-15 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-09-15 |
Time |
14:57 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2014-09-15 |
Time |
14:41 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2014-05-29 |
|
|
Cont ID |
|
| Sent By |
jsaez |
Date |
2014-05-29 |
Time |
15:16 |
Rev Time |
0.00 |
| Received By |
jsaez |
Date |
2014-05-29 |
Time |
15:00 |
Sent To |
|
|
| Notes |
| 2014-05-29 15:10:13 | FAILED MECHANICAL REVIEW AS FOLLOWS: | | | 1. PROVIDE A.H.U. SCHUDULE | | | THESE PLANS WERE REVIEWED BY JOEY SAEZ, MECHANICAL | | | PLANS EXAMINER | | | YOU ARE WELCOME TO REVIEW STATUS OR COMMENTS AT THE | | | FOLLOWING LINK: | | | | | | HTTP://ONESTOPSHOP.WPBGOV.COM/EGOVPLUS/PERMIT/PERM_STAT | | | US.ASPX | | | | | | ENTER YOUR PERMIT NUMBER (SEE SUBJECT LINE OF THIS | | | EMAIL FOR YOUR PERMIT #), CLICK ON THE PERMIT NUMBER, | | | AND THEN GO TO "PLAN REVIEWS" TO SEE YOUR COMMENTS (TAB | | | ABOVE THE SECOND PERMIT INFORMATION). | | | AFTER ISSUANCE, PLEASE CHECK YOUR PLAN CAREFULLY FOR | | | COMPLIANCE WITH ANY REDLINES, NOTES, PROVISOS, OR OTHER | | | PERMIT CONDITIONS. | | | | | | FEEL FREE TO CONTACT ME DIRECTLY AT: [email protected] | | | | | | THESE PLANS WERE REVIEWED BY JOEY SAEZ, MECHANICAL | | | PLANS EXAMINER | | | YOU ARE WELCOME TO REVIEW STATUS OR COMMENTS AT THE | | | FOLLOWING LINK: | | | | | | HTTP://ONESTOPSHOP.WPBGOV.COM/EGOVPLUS/PERMIT/PERM_STAT | | | US.ASPX | | | | | | ENTER YOUR PERMIT NUMBER (SEE SUBJECT LINE OF THIS | | | EMAIL FOR YOUR PERMIT #), CLICK ON THE PERMIT NUMBER, | | | AND THEN GO TO "PLAN REVIEWS" TO SEE YOUR COMMENTS (TAB | | | ABOVE THE SECOND PERMIT INFORMATION). | | | AFTER ISSUANCE, PLEASE CHECK YOUR PLAN CAREFULLY FOR | | | COMPLIANCE WITH ANY REDLINES, NOTES, PROVISOS, OR OTHER | | | PERMIT CONDITIONS. | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2014-06-04 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-06-04 |
Time |
16:52 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2014-06-04 |
Time |
16:52 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
P |
Date |
2014-09-15 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-09-15 |
Time |
17:56 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2014-09-15 |
Time |
17:56 |
Sent To |
|
|
| Notes |
| 2014-09-15 18:02:56 | ROOFING PRODUCT APPROVALS. | | | | | | - CLAY BARREL TILE, NOA NO. 13-0226.01 | | | | | | - AH - 160 ROOF TILE ADHESIVE, NOA NO. 12-0228.18 | | | | | | - TAMKO MODIFIED ROOF SYSTEM, FL735-R8 ( NOA NO. | | | 12-0716.18 ) AND RAS 117 CALCULATIONS. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2014-05-05 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2014-05-05 |
Time |
09:22 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2014-05-05 |
Time |
09:22 |
Sent To |
|
|
| Notes |
|
|