Plan Review Details - Permit 14050111
| Plan Review Stops For Permit 14050111 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2014-08-19 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2014-08-19 |
Time |
17:26 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-08-19 |
Time |
15:17 |
Sent To |
|
|
| Notes |
| 2014-08-19 16:30:12 | BUILDING PLAN REVIEW | | | PERMIT:14050111 | | | ADD: 600 OKEECHOBEE BLVD | | | CONT: COASTAL CONSTRUCTION | | | TEL: (561) 630-3770 | | | | | | 2010 FLORIDA BUILDING CODE W | | | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | | | THE PALM BEACH CONVENTION CENTER HILTON HOTEL | | | CONSTRUCTION OF NEW 400 ROOM HOTEL INCLUDING BALLROOMS, | | | RESTAURANT(S), MEETING SPACE, POOL DECK AND AMENITIES | | | | | | 3RD REVIEW | | | DATE: TUES. AUGUST 19/ 2014 | | | | | | ACTION:BUILDING PROVISO | | | BUILDING APPROVED WITH EXCEPTION! | | | THIS PLAN HAS BEEN APPROVED PROVISIONALLY. FAILURE TO | | | CORRECT THE LISTED DEFICIENCIES IN THIS PLAN PRIOR TO | | | INSPECTION WILL RESULT IN FAILED INSPECTION(S) AND THE | | | ASSESSMENT OF RE-INSPECTION FEE(S). REVISIONS REQUIRE | | | ADDITIONAL REVIEWS WITH ASSOCIATED FEES. | | | | | | 1) THE PERMIT DESCRIPTION LISTED ABOVE TO BUILD THE | | | HOTEL, POOL, POOL DECK & AMENITIES IS A INCLUSIVE | | | PACKAGE WITHIN THE SUBMITTED PLANS. THERE ARE CIVIL, | | | SITE, LANDSCAPING, IRRIGATION, GREASE INTERCEPTORS, | | | FUEL GAS, GENERATOR, FIRE SPRINKLER, FIRE ALARM, | | | LOWVOLTAGE, AWNINGS AND SIGNAGE PLANS WITHIN THE | | | SUBMITTED DOCUMENTS. | | | THESE TYPE OF ACTIVITIES REQUIRE A SEPARATE PERMIT | | | APPLICATION, REVIEW AND ASSOCIATED FEES. PLEASE BACK | | | OUT THE VALUE OF WORK TO BE COMPLETED UNDER EACH OF | | | THESE PERMITS SO THE BUILDING DEPARTMENT DOES NOT | | | CHARGE YOU TWICE FOR THESE SERVICES. 2010 WEST PALM | | | BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER | | | 1, ADMINISTRATION 105.1 PERMITS | | | | | | 2) 0211-A2.01/ BASEMENT LEVEL: REVISION IS REQUIRED. | | | THE FIRST COMMENT ASKED WHY THER WAS STORAGE BINS IN | | | THE CORRIDOR, THE RESPONSE INDICATES THESE ARE SOILED | | | LAUNDRY BINS. | | | SOILED LAUNDRY IS CONSIDERED AN INCIDENTIAL ACCESSORY | | | OCCUPANY IN ITSELF, AND IS TO BE SEPARATE WITHIN A | | | ROOM, NOT IN A EXIT ACCESS COORIDOR, | | | SEE THE 2010 FBC-B TABLE 508.2.5. IT STATES THAT | | | LAUNDRY ROOMS ARE TO BE SEPARATED BY 1 HR ROOM OR | | | PROVIDE FIRE SPRINKLERS. PLEASE REVIEW 508.2.5.2 | | | NONFIRE-RESISTANCE-RATED SEPARATION AND PROTECTION. | | | WHERE TABLE 508.2.5 PERMITS AN AUTOMATIC | | | FIRE-EXTINGUISHING SYSTEM WITHOUT A FIRE BARRIER, THE | | | INCIDENTAL ACCESSORY OCCUPANCIES SHALL BE SEPARATED | | | FROM THE REMAINDER OF THE BUILDING BY CONSTRUCTION | | | CAPABLE OF RESISTING THE PASSAGE OF SMOKE. THE WALLS | | | SHALL EXTEND FROM THE TOP OF THE FOUNDATION OR FLOOR | | | ASSEMBLY BELOW TO THE UNDERSIDE OF THE CEILING THAT IS | | | A COMPONENT OF A FIRE-RESISTANCE-RATED FLOOR ASSEMBLY | | | OR ROOF ASSEMBLY ABOVE OR TO THE UNDERSIDE OF THE FLOOR | | | OR ROOF SHEATHING, DECK OR SLAB ABOVE. DOORS SHALL BE | | | SELF- OR AUTOMATIC-CLOSING UPON DETECTION OF SMOKE IN | | | ACCORDANCE WITH SECTION 715.4.8.3. DOORS SHALL NOT HAVE | | | AIR TRANSFER OPENINGS AND SHALL NOT BE UNDERCUT IN | | | EXCESS OF THE CLEARANCE PERMITTED IN ACCORDANCE WITH | | | NFPA 80. WALLS SURROUNDING THE INCIDENTAL ACCESSORY | | | OCCUPANCY SHALL NOT HAVE AIR TRANSFER OPENINGS UNLESS | | | PROVIDED WITH SMOKE DAMPERS IN ACCORDANCE WITH SECTION | | | 711.7. | | | | | | 3) COMPLIED ,LULA LIFT. | | | | | | 4A) NEW COMMENT/ SEMI NEW, NEW LOCATION, THE EXECUTIVE | | | LOUNGE HAS BEEN MOVED TO ROOM # 207 THE COMMENTS STILL | | | EXIST. THE EXECUTIVE LOUNGE HAS A OCCUPANT LOAD OF 73 | | | THIS IS AN ASSEMBLY OCCUPANCY PLEASE PROVIDE A | | | FURNATURE LATOUT. SHEET A3.00 DOES NOT INCLUDE THIS | | | ROOM IN THE PLUMBING FIXTURE COUNT. DEPENDING ON THE | | | USAGE THIS MAY BE CONSIDERED EIHER AN A2 OR A3, IF | | | CONSIDERED MORE AS A LOUNGE A-2 THE WATER CLOSET RATIO | | | WILL BE 1/40 REQUIRING ADDITIONAL FIXTURES. | | | | | | 4B) ROOM 207 THE EXECUTIVE LOUNGE, THERE IS A SMALL | | | ROOM THAT NO INFORMATION HAS BEEN PROVIDED, IS THIS FOR | | | STORAGE, BAR OR KITCHEN TO BE USED IN CONJUNCTION WITH | | | THE LOUNGE? FBC-B 302.1. NOTE FBC-B 1014.2 EGRESS | | | THROUGH INTERVENING SPACES. 4. EGRESS SHALL NOT PASS | | | THROUGH KITCHENS, STORAGE ROOMS, CLOSETS OR SPACES USED | | | FOR SIMILAR PURPOSES. | | | | | | 5) SHEET A4.20 SECTION THRU BUILDING A12.10 : 2010 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1, ADMINISTRATION | | | SHOW COMPLIANCE NOTES ON PLANS QUATING CODE DOES NOT | | | MEAN COMPLIED. 107.2.1 INFORMATION ON CONSTRUCTION | | | DOCUMENTS SUCH INFORMATION SHALL BE SPECIFIC, AND THE | | | TECHNICAL CODES SHALL NOT BE CITED AS A WHOLE OR IN | | | PART, NOR SHALL THE TERM "LEGAL" OR ITS EQUIVALENT BE | | | USED AS A SUBSTITUTE FOR SPECIFIC INFORMATION. | | | 16A NOTES ON THE PLANS INDICATES THE USE OF ALUMINUM | | | COMPOSITE WALL PANELS, PLEASE PROVIDE DOCUMENTATION FOR | | | CODE COMPLIANCE WITH: 2010 FBC-B 1407.2 EXTERIOR WALL | | | FINISH. | | | MCM USED AS EXTERIOR WALL FINISH OR AS ELEMENTS OF | | | BALCONIES AND SIMILAR PROJECTIONS AND BAY AND ORIEL | | | WINDOWS TO PROVIDE CLADDING OR WEATHER RESISTANCE SHALL | | | COMPLY WITH SECTIONS 1407.4 THROUGH 1407.14. | | | | | | 6) DEFFERED SUBMITTAL; A12.10 DETAILS 1 & 8 BOTH | | | INDICATE THE PERIMETER SUN SCREEN , DETAIL 3 A12.09 | | | ALSO A CLOSE UP OF THE PERIMETER SUNSCREEN INDICATE THE | | | USE OF STEEL EMBEDS W/ NELSON BOLTS PER THE | | | MANUFACTURERS REQUIREMENTS. PLEASE PROVIDE ENGINEERING | | | FOR THIS SYSTEM THAT THE DESIGN AND ATTACHMENTS WILL | | | MEET THE WINDLOADS AND HEIGHT ADJUSTMENT FACTORS FOR | | | THIS ELEVATION, TO BE DESIGNED TO ASCE 7-10 .1609.1.1 | | | DETERMINATION OF WIND LOADS. WIND LOADS ON EVERY | | | BUILDING OR STRUCTURE SHALL BE DETERMINED IN ACCORDANCE | | | WITH CHAPTERS 26 THROUGH 30 OF ASCE 7 OR THE PROVISIONS | | | OF THE ALTERNATE ALL HEIGHTS METHOD IN SECTION 1609.6. | | | L | | | | | | 7) THE FPL VAULT REQUIRES 3 HR WALLS 2008 NEC THE DOORS | | | ALSO REQUIRE A 3 HR RATING PER 2008 NEC 450.43(A) & | | | 2010 FBC-B TABLE 715.4. | | | | | | | | | 8) PLEASE CLARIFY: MICHAEL STELLINO & I HAVE SPOKEN ON | | | THIS SUBJECT. WHAT APPEARS TO BE A LINEN CHUTE DOOR IS | | | SUPPOSE TO BE A RECESSED FIRE EXTINGUISHER CABINET. | | | PLEASE CLARIFY. THE RESPONSE INDICATES THAT THE LINEN | | | CHUTE DOOR IS IDENTIFIED AS T26. PLEASE REVIEW THE DOOR | | | SCHEDULE ON A14.01, T26 IS FOR THE ICE ROOM NEXT TO THE | | | LAUNDRY CHUTE, THAT DOES NOT HAVE ANY DOOR, NOR IS THE | | | ARK OF A DOOR INDICATED ON THE PLANS. | | | | | | SHEET A2.10 SHOWS THE LAUNDRY CHUTE LOCATED ON THE GRID | | | LINES X.1 JUST NORTH & Y.2 CENTERED ON THE GRID LINE | | | WHICH IS LOCATED IN THE MAIDS ROOM.FLOORS 10-12 SEE | | | SHEET A2.11 THE LAUBDRY CHUTE IS OFFSET TO THE | | | NORTHEAST OR TO THE EAST OF GRID LINE Y.2 . THE PLANS | | | SHOW THE ACCESS TO THE ACCESS CHUTE DOOR LOCATED WITH | | | THE CORRADOR. PLEASE CONFORM WITH: | | | | | | 2010 FBC-B 708.13.3 REFUSE AND LAUNDRY CHUTE ACCESS | | | ROOMS. | | | ACCESS OPENINGS FOR REFUSE AND LAUNDRY CHUTES SHALL BE | | | LOCATED IN ROOMS OR COMPARTMENTS ENCLOSED BY NOT LESS | | | THAN 1-HOUR FIRE BARRIERS CONSTRUCTED IN ACCORDANCE | | | WITH SECTION 707 OR HORIZONTAL ASSEMBLIES CONSTRUCTED | | | IN ACCORDANCE WITH SECTION 712, OR BOTH. OPENINGS INTO | | | THE ACCESS ROOMS SHALL BE PROTECTED BY OPENING | | | PROTECTIVES HAVING A FIRE PROTECTION RATING OF NOT LESS | | | THAN 3/4 HOUR. DOORS SHALL BE SELF- OR | | | AUTOMATIC-CLOSING UPON THE DETECTION OF SMOKE IN | | | ACCORDANCE WITH SECTION 715.4.8.3. | | | | | | 8B) . SHEET A12.16 SHOWS A NEW DETAIL WITH A FIRE RISER | | | WITHIN THE 2 HR FIRE RATED CHASE BUT THE SPRINKLER HEAD | | | DOES NOT PENETRATE INTO THE THE LINEN CHUTE NOR DOES | | | THERE SHOW HOW THE SPRINKLER HEAD HAS ACCESSIBILITY FOR | | | MAINTENANCE. | | | SHEET A7.15 THE LINEN CHUTE DETAILS DO NOT MENTION THE | | | REQUIREMENT OR ANY ALLOWANCES FOR FIRE SPRINKLERS IN | | | THE LINEN CHUTE. THE FIRE SPRINKLER SHEETS ONLY PROVIDE | | | A DEAIL ON FP0.01 INDICATING SERVICE CHUTE DETAIL. | | | 708.13.6 AUTOMATIC SPRINKLER SYSTEM. | | | AN APPROVED AUTOMATIC SPRINKLER SYSTEM SHALL BE | | | INSTALLED IN ACCORDANCE WITH SECTION 903.2.11.2 F] | | | 903.2.11.2 RUBBISH AND LINEN CHUTES. | | | AN AUTOMATIC SPRINKLER SYSTEM SHALL BE INSTALLED AT THE | | | TOP OF RUBBISH AND LINEN CHUTES AND IN THEIR TERMINAL | | | ROOMS. CHUTES EXTENDING THROUGH THREE OR MORE FLOORS | | | SHALL HAVE ADDITIONAL SPRINKLER HEADS INSTALLED WITHIN | | | SUCH CHUTES AT ALTERNATE FLOORS. CHUTE SPRINKLERS SHALL | | | BE ACCESSIBLE FOR SERVICING. | | | | | | THE LAUNDRY CHUTE DETAIL SHEET ALSO DOESN'T MAKE | | | REFERANCE TO THE REQUIREMENT FOR CHUTE SPRINKLERS SHALL | | | BE ACCESSIBLE FOR SERVICING THIS MAY BE A ISSUE WHERE | | | THE RECESSED FIRE EXTINGUISHER BOXES ARE LOCATED ON THE | | | 10-12TH FLOORS IN FRONT OF THE LAUNDRY CHUTE. | | | | | | 9A) DEFERRED SUBMITTAL UNDER 107.3.4.2 BUT THE | | | PRESSURES HAVE TO BE INALLIZED BEFORE PERMIT ISSUANCE. | | | 2010 FBC-B 1609.1.2 PROTECTION OF OPENINGS, 1609.6.4.41 | | | COMPONENTS & CLADDING. | | | FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS RULE 9N-3 NOV. | | | 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION | | | SYSTEMS THAT WILL REQUIRE PRODUCT APPROVALS: | | | (31)(A) EXTERIOR DOORS. | | | (B) WINDOWS | | | (C) PANEL WALLS: STOREFRONTS, CURTAIN WALLS, WALL | | | LOUVERS, EFIS SYSTEMS, | | | (D) ROOFING PRODUCTS AND ASSEMBLIES | | | (E) SHUTTERS | | | (F) SKYLIGHTS | | | (G) EXTERIOR COOLER, FREEZERS & PRE-ENGINEERED A/C | | | STANDS | | | | | | 9B) DEFERRED SUBMITTAL UNDER 107.3.4.2. 2010 FBC | | | 107.3.4.1 PRODUCT APPROVALS. THOSE PRODUCTS WHICH ARE | | | REGULATED BY THE DCA RULE 9N-03 SHALL BE REVIEWED AND | | | APPROVED IN WRITING BY THE DESIGNER OF RECORD PRIOR TO | | | SUBMITTAL FOR JURISDICTIONAL APPROVAL. FL 61G1-23.015 | | | (2) THE ARCHITECT IS RESPONSIBLE FOR SUPERVISING AND | | | REVIEWING ALL PROJECT DATA, REPORTS, SHOP DRAWINGS | | | ETC.. | | | | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2014-08-06 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2014-08-06 |
Time |
07:45 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-08-01 |
Time |
07:05 |
Sent To |
|
|
| Notes |
| 2014-08-02 14:06:53 | BUILDING PLAN REVIEW | | | PERMIT:14050111 | | | ADD: 600 OKEECHOBEE BLVD | | | CONT: COASTAL CONSTRUCTION | | | TEL: (561) 630-3770 | | | | | | 2010 FLORIDA BUILDING CODE W | | | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | | | THE PALM BEACH CONVENTION CENTER HILTON HOTEL | | | CONSTRUCTION OF NEW 400 ROOM HOTEL INCLUDING BALLROOMS, | | | RESTAURANT(S), MEETING SPACE, POOL DECK AND AMENITIES | | | | | | 2ND REVIEW | | | DATE: SAT. AUGUST 02/ 2014 | | | | | | ACTION: DENIED | | | | | | 1) THE PERMIT DESCRIPTION LISTED ABOVE TO BUILD THE | | | HOTEL, POOL, POOL DECK & AMENITIES IS A INCLUSIVE | | | PACKAGE WITHIN THE SUBMITTED PLANS. THERE ARE CIVIL, | | | SITE, LANDSCAPING, IRRIGATION, GREASE INTERCEPTORS, | | | FUEL GAS, GENERATOR, FIRE SPRINKLER, FIRE ALARM, | | | LOWVOLTAGE, AWNINGS AND SIGNAGE PLANS WITHIN THE | | | SUBMITTED DOCUMENTS. | | | THESE TYPE OF ACTIVITIES REQUIRE A SEPARATE PERMIT | | | APPLICATION, REVIEW AND ASSOCIATED FEES. PLEASE BACK | | | OUT THE VALUE OF WORK TO BE COMPLETED UNDER EACH OF | | | THESE PERMITS SO THE BUILDING DEPARTMENT DOES NOT | | | CHARGE YOU TWICE FOR THESE SERVICES. 2010 WEST PALM | | | BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER | | | 1, ADMINISTRATION 105.1 PERMITS | | | | | | 2) UNDER CONSIDERATION BY THE BUILDING OFFICIAL. THE | | | APPLIED VALUE OF THE HOTEL IS VALUED AT $35,000,000.00. | | | THE CALCULATED VALUE OF THE PROJECT IS $55,930,374.00 | | | (312,216 SQ FT X $179.14 BUILDING ONLY, NO SITE | | | DEVELOPMENT) USING THE ICC BUILDING VALUATION DATA FOR | | | BOTH AUGUST 2013 & FEB, 2014. W P B ADMINISTRTIVE CODE | | | 108.2 SCHEDULE OF PERMIT FEES. ON BUILDINGS, | | | STRUCTURES, ELECTRICAL, GAS, MECHANICAL, AND PLUMBING | | | SYSTEMS OR ALTERATIONS REQUIRING A PERMIT, A FEE FOR | | | EACH PERMIT SHALL BE PAID AS REQUIRED, IN ACCORDANCE | | | WITH THE SCHEDULE ESTABLISHED BY THE APPLICABLE | | | GOVERNING AUTHORITY. | | | IF A BUILDING BREAK OUT OF SQUARE FOOTAGE UNDER EACH | | | OCCUPANCY CLASSIFICATION THIS NUMBER WOUD DROP SOME | | | WHAT, THIS WAS UNOT COMPLETED UNDER THE OCCUPANCY | | | CLASSIFICATION, PROBANLY BECAUSE OF UNLIMITED AREA FOR | | | A TYPE 1A BUILDING TYPE. | | | | | | 108.3* BUILDING PERMIT VALUATION. | | | IF, IN THE OPINION OF THE BUILDING OFFICIAL, THE | | | CLAIMED VALUATION OF BUILDING, ALTERATION, STRUCTURE, | | | ELECTRICAL, GAS, MECHANICAL, OR PLUMBING SYSTEMS | | | APPEARS TO BE UNDER ESTIMATED ON THE APPLICATION, THE | | | PERMIT SHALL BE DENIED. FOR PERMITTING PURPOSES, | | | VALUATION OF BUILDINGS AND SYSTEMS SHALL BE TOTAL | | | REPLACEMENT PURPOSES, VALUATION OF BUILDINGS AND | | | SYSTEMS SHALL BE THE TOTAL REPLACEMENT VALUE TO INCLUDE | | | STRUCTURAL, ELECTRICAL, PLUMBING, MECHANICAL, INTERIOR | | | FINISHES, NORMAL SITE WORK (EXCAVATION AND BACKFILL FOR | | | BUILDINGS), ARCHITECTURAL AND DESIGN FEES, MARKETING | | | COST, OVERHEAD AND PROFIT; EXCLUDING ONLY LAND VALUE. | | | VALUATION REFRENCES MAY INCLUDE THE LATEST PUBLISHED | | | DATA OF NATIONAL CONSTRUCTION COST ANALYSIS SERVICES | | | (MARSHALL-SWIFT, MEANS, ETC) WITH REGIONAL ADJUSTMENTS | | | FOR LOCATION AS PUBLISHED BY THE INTERNATIONAL CODE | | | CONGRESS. | | | | | | 3) 0210-A2.00: | | | | | | 3) COMPLIED. | | | 4) 0211-A2.01/ BASEMENT LEVEL: | | | | | | 4A) 2ND REQUEST, THE FIRST COMMENT ASKED WHY THER WAS | | | STORAGE BINS IN THE CORRIDOR, THE RESPONSE INDICATES | | | THESE ARE SOILED LAUNDRY BINS. | | | SOILED LAUNDRY IS CONSIDERED AN INCIDENTIAL ACCESSORY | | | OCCUPANY IN ITSELF, AND IS TO BE SEPARATE WITHIN A | | | ROOM, NOT IN A EXIT ACCESS COORIDOR, | | | SEE THE 2010 FBC-B TABLE 508.2.5. IT STATES THAT | | | LAUNDRY ROOMS ARE TO BE SEPARATED BY 1 HR ROOM OR | | | PROVIDE FIRE SPRINKLERS. PLEASE REVIEW 508.2.5.2 | | | NONFIRE-RESISTANCE-RATED SEPARATION AND PROTECTION. | | | WHERE TABLE 508.2.5 PERMITS AN AUTOMATIC | | | FIRE-EXTINGUISHING SYSTEM WITHOUT A FIRE BARRIER, THE | | | INCIDENTAL ACCESSORY OCCUPANCIES SHALL BE SEPARATED | | | FROM THE REMAINDER OF THE BUILDING BY CONSTRUCTION | | | CAPABLE OF RESISTING THE PASSAGE OF SMOKE. THE WALLS | | | SHALL EXTEND FROM THE TOP OF THE FOUNDATION OR FLOOR | | | ASSEMBLY BELOW TO THE UNDERSIDE OF THE CEILING THAT IS | | | A COMPONENT OF A FIRE-RESISTANCE-RATED FLOOR ASSEMBLY | | | OR ROOF ASSEMBLY ABOVE OR TO THE UNDERSIDE OF THE FLOOR | | | OR ROOF SHEATHING, DECK OR SLAB ABOVE. DOORS SHALL BE | | | SELF- OR AUTOMATIC-CLOSING UPON DETECTION OF SMOKE IN | | | ACCORDANCE WITH SECTION 715.4.8.3. DOORS SHALL NOT HAVE | | | AIR TRANSFER OPENINGS AND SHALL NOT BE UNDERCUT IN | | | EXCESS OF THE CLEARANCE PERMITTED IN ACCORDANCE WITH | | | NFPA 80. WALLS SURROUNDING THE INCIDENTAL ACCESSORY | | | OCCUPANCY SHALL NOT HAVE AIR TRANSFER OPENINGS UNLESS | | | PROVIDED WITH SMOKE DAMPERS IN ACCORDANCE WITH SECTION | | | 711.7. | | | | | | 1ST REVIEW COMMENT. THE SERVICE COORIDOR B000 IN FRONT | | | OF THE HOUSEMANS STORAGE AND HOUSE KEEPING LAUNDRY IT | | | APPEARS THERE IS STORAGE CABINETS BEING STORED WITHIN | | | THE CORRIDOR? PLEASE EXPLAIN THE USAGE OF THIS AREA? | | | 107.2.1.3 ADDITIONAL INFORMATION IS REQUIRED. | | | | | | 4B) COMPLIED. | | | | | | 5) 0212-A2.02/ LEVEL 0100 | | | | | | 5A-B) COMPLIED. | | | | | | 5C) 2ND REQUEST. THE RESPONCE INDICATES THE LULA LIFT | | | IS TO BE ON STANDBY POWER. THE NOTE ABOVE THE LULA LIFT | | | INDICATES THAT IT IS GOING TO BE HOOKED UP TO JRH-31 | | | WHICH IS FOR THE JUNIOR BALL ROOM, ISN'T THE LIFT ON | | | THE CONNVENTION CENTER SIDE OF THE PROPERTY LINE, AND | | | SHOULDN'T ALL THE POWER FOR THIS SIDE OF THE PROPERTY | | | BE COMING FROM THE CONVENTION CENTER? | | | NOTE THE PERMIT FOR THE HOTEL STOPS AT THE PROPERTY | | | LINE, A SECOND PERMIT WILL BE NEEDED FOR THE | | | CONSTRUCTION ACTIVITIES ON THE CONVENTION CENTER | | | PROPERTY. AGAIN THE LULA LIFT IS CONSIDERED AN ELEVATOR | | | AND TREATED AS SUCH. FBC-B 403.4.7.2 (3) DOES NOT SAY | | | ANYTHING ABOUT LIFTS. | | | [F] 403.4.7.2 STANDBY POWER LOADS. | | | THE FOLLOWING ARE CLASSIFIED AS STANDBY POWER LOADS: 3. | | | STANDBY POWER SHALL BE PROVIDED FOR ELEVATORS IN | | | ACCORDANCE WITH SECTIONS 1006.2.4, 3003, 3007 AND 3008. | | | | | | 5D-F COMPLIED. | | | | | | 5G) 2ND REQUEST, NOT SHOWN ON THIS SHEET BUT A4.04 DOES | | | SHOW THE WEST PROPERTY LINE GOING THROUGH THE CABANAS | | | AND POOL ON THE WEST OF THE PROPERTY. | | | UNITY OF TITLE. THE PROPOSED BUILDING STRUCTURE | | | TRANSGRESSES LEGAL BOUNDARY LINES BETWEEN THE LOTS | | | WHICH COMBINE TO FORM 'THE SITE'. A 'UNITY OF TITLE' | | | SHALL BE | | | RECORDED AT THE COUNTY COURTHOUSE. SUBMIT A COPY OF THE | | | RECORDED 'UNITY OF OF TITLE' DOCUMENT SO THAT FBC TABLE | | | 601 BOUNDARY LINE REQUIREMENTS MAY BE DEEMED | | | NOT APPLICABLE. | | | SEE WEBSITE FOR APPLICATION: | | | HTTP://WWW.WPB.ORG/ENGINEERING/ENG_FORMS.PHP | | | "APPLICATION FOR UNITY OF TITLE" | | | HTTP://WWW.WPB.ORG/ENGINEERING/UPLOADS/2010-10-12-14-45 | | | -38-UNITYOFTITLE3.PDF | | | | | | 6A-B) COMPLIED. | | | | | | 6C) NEW COMMENT/ SEMI NEW, NEW LOCATION, THE EXECUTIVE | | | LOUNGE HAS BEEN MOVED TO ROOM # 207 THE COMMENTS STILL | | | EXIST. THE EXECUTIVE LOUNGE HAS A OCCUPANT LOAD OF 73 | | | THIS IS AN ASSEMBLY OCCUPANCY PLEASE PROVIDE A | | | FURNATURE LATOUT. SHEET A3.00 DOES NOT INCLUDE THIS | | | ROOM IN THE PLUMBING FIXTURE COUNT. DEPENDING ON THE | | | USAGE THIS MAY BE CONSIDERED EIHER AN A2 OR A3, IF | | | CONSIDERED MORE AS A LOUNGE A-2 THE WATER CLOSET RATIO | | | WILL BE 1/40 REQUIRING ADDITIONAL FIXTURES. | | | | | | 6D) ROOM 207 THE EXECUTIVE LOUNGE, THERE IS A SMALL | | | ROOM THAT NO INFORMATION HAS BEEN PROVIDED, IS THIS FOR | | | STORAGE, BAR OR KITCHEN TO BE USED IN CONJUNCTION WITH | | | THE LOUNGE? FBC-B 302.1. NOTE FBC-B 1014.2 EGRESS | | | THROUGH INTERVENING SPACES. 4. EGRESS SHALL NOT PASS | | | THROUGH KITCHENS, STORAGE ROOMS, CLOSETS OR SPACES USED | | | FOR SIMILAR PURPOSES. | | | | | | 7-15) COMPLIED. | | | | | | 16) SHEET A4.20 SECTION THRU BUILDING A12.10 : 2010 | | | WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING | | | CODE, CHAPTER 1, ADMINISTRATION | | | SHOW COMPLIANCE NOTES ON PLANS QUATING CODE DOES NOT | | | MEAN COMPLIED. 107.2.1 INFORMATION ON CONSTRUCTION | | | DOCUMENTS SUCH INFORMATION SHALL BE SPECIFIC, AND THE | | | TECHNICAL CODES SHALL NOT BE CITED AS A WHOLE OR IN | | | PART, NOR SHALL THE TERM "LEGAL" OR ITS EQUIVALENT BE | | | USED AS A SUBSTITUTE FOR SPECIFIC INFORMATION. | | | 16A NOTES ON THE PLANS INDICATES THE USE OF ALUMINUM | | | COMPOSITE WALL PANELS, PLEASE PROVIDE DOCUMENTATION FOR | | | CODE COMPLIANCE WITH: 2010 FBC-B 1407.2 EXTERIOR WALL | | | FINISH. | | | MCM USED AS EXTERIOR WALL FINISH OR AS ELEMENTS OF | | | BALCONIES AND SIMILAR PROJECTIONS AND BAY AND ORIEL | | | WINDOWS TO PROVIDE CLADDING OR WEATHER RESISTANCE SHALL | | | COMPLY WITH SECTIONS 1407.4 THROUGH 1407.14. | | | | | | 16B) A12.10 DETAILS 1 & 8 BOTH INDICATE THE PERIMETER | | | SUN SCREEN , DETAIL 3 A12.09 ALSO A CLOSE UP OF THE | | | PERIMETER SUNSCREEN INDICATE THE USE OF STEEL EMBEDS W/ | | | NELSON BOLTS PER THE MANUFACTURERS REQUIREMENTS. PLEASE | | | PROVIDE ENGINEERING FOR THIS SYSTEM THAT THE DESIGN AND | | | ATTACHMENTS WILL MEET THE WINDLOADS AND HEIGHT | | | ADJUSTMENT FACTORS FOR THIS ELEVATION, TO BE DESIGNED | | | TO ASCE 7-10 .1609.1.1 DETERMINATION OF WIND LOADS. | | | WIND LOADS ON EVERY BUILDING OR STRUCTURE SHALL BE | | | DETERMINED IN ACCORDANCE WITH CHAPTERS 26 THROUGH 30 OF | | | ASCE 7 OR THE PROVISIONS OF THE ALTERNATE ALL HEIGHTS | | | METHOD IN SECTION 1609.6. L | | | | | | 17-21) COMPLIED. | | | | | | 22A-C) COMPLIED. | | | | | | 22D) THE FPL VAULT REQUIRES 3 HR WALLS 2008 NEC THE | | | DOORS ALSO REQUIRE A 3 HR RATING PER 2008 NEC 450.43(A) | | | & 2010 FBC-B TABLE 715.4. | | | | | | | | | 23) A5.18: | | | WALL IDENTIFICATION TAGS ARE MISSING AND IDENTIFICATION | | | OF FIRE RATED WALLS. ADDITIONAL INFORMATION IS | | | REQUIRED. SEE LIFE SAFETY PLAN FOR WALL FIRE RATING | | | DISCREPANCY IN PLANS. 107.2.1.3. | | | | | | 24-25) COMPLIED. | | | | | | 26) 2ND REQUEST. THE RESPONSE INDICATES THAT THE LINEN | | | CHUTE DOOR IS IDENTIFIED AS T26. PLEASE REVIEW THE DOOR | | | SCHEDULE ON A14.01, T26 IS FOR THE ICE ROOM NEXT TO THE | | | LAUNDRY CHUTE, THAT DOES NOT HAVE ANY DOOR, NOR IS THE | | | ARK OF A DOOR INDICATED ON THE PLANS. | | | | | | SHEET A2.10 SHOWS THE LAUNDRY CHUTE LOCATED ON THE GRID | | | LINES X.1 JUST NORTH & Y.2 CENTERED ON THE GRID LINE | | | WHICH IS LOCATED IN THE MAIDS ROOM.FLOORS 10-12 SEE | | | SHEET A2.11 THE LAUBDRY CHUTE IS OFFSET TO THE | | | NORTHEAST OR TO THE EAST OF GRID LINE Y.2 . THE PLANS | | | SHOW THE ACCESS TO THE ACCESS CHUTE DOOR LOCATED WITH | | | THE CORRADOR. PLEASE CONFORM WITH: | | | | | | 2010 FBC-B 708.13.3 REFUSE AND LAUNDRY CHUTE ACCESS | | | ROOMS. | | | ACCESS OPENINGS FOR REFUSE AND LAUNDRY CHUTES SHALL BE | | | LOCATED IN ROOMS OR COMPARTMENTS ENCLOSED BY NOT LESS | | | THAN 1-HOUR FIRE BARRIERS CONSTRUCTED IN ACCORDANCE | | | WITH SECTION 707 OR HORIZONTAL ASSEMBLIES CONSTRUCTED | | | IN ACCORDANCE WITH SECTION 712, OR BOTH. OPENINGS INTO | | | THE ACCESS ROOMS SHALL BE PROTECTED BY OPENING | | | PROTECTIVES HAVING A FIRE PROTECTION RATING OF NOT LESS | | | THAN 3/4 HOUR. DOORS SHALL BE SELF- OR | | | AUTOMATIC-CLOSING UPON THE DETECTION OF SMOKE IN | | | ACCORDANCE WITH SECTION 715.4.8.3. | | | | | | 27) 2ND REQUEST. SHEET A12.16 SHOWS A NEW DETAIL WITH A | | | FIRE RISER WITHIN THE 2 HR FIRE RATED CHASE BUT THE | | | SPRINKLER HEAD DOES NOT PENETRATE INTO THE THE LINEN | | | CHUTE NOR DOES THERE SHOW HOW THE SPRINKLER HEAD HAS | | | ACCESSIBILITY FOR MAINTENANCE. | | | SHEET A7.15 THE LINEN CHUTE DETAILS DO NOT MENTION THE | | | REQUIREMENT OR ANY ALLOWANCES FOR FIRE SPRINKLERS IN | | | THE LINEN CHUTE. THE FIRE SPRINKLER SHEETS ONLY PROVIDE | | | A DEAIL ON FP0.01 INDICATING SERVICE CHUTE DETAIL. | | | 708.13.6 AUTOMATIC SPRINKLER SYSTEM. | | | AN APPROVED AUTOMATIC SPRINKLER SYSTEM SHALL BE | | | INSTALLED IN ACCORDANCE WITH SECTION 903.2.11.2 F] | | | 903.2.11.2 RUBBISH AND LINEN CHUTES. | | | AN AUTOMATIC SPRINKLER SYSTEM SHALL BE INSTALLED AT THE | | | TOP OF RUBBISH AND LINEN CHUTES AND IN THEIR TERMINAL | | | ROOMS. CHUTES EXTENDING THROUGH THREE OR MORE FLOORS | | | SHALL HAVE ADDITIONAL SPRINKLER HEADS INSTALLED WITHIN | | | SUCH CHUTES AT ALTERNATE FLOORS. CHUTE SPRINKLERS SHALL | | | BE ACCESSIBLE FOR SERVICING. | | | | | | THE LAUNDRY CHUTE DETAIL SHEET ALSO DOESN'T MAKE | | | REFERANCE TO THE REQUIREMENT FOR CHUTE SPRINKLERS SHALL | | | BE ACCESSIBLE FOR SERVICING. | | | | | | 28-32) COMPLIED. | | | | | | 33) COMPLIED. 8/07/2014 SIGNED & SEALED ORIGINAL | | | SUBMITTED BY APPLICANT. | | | | | | A DRAFT COPY OF A WIND TUNNEL TEST WAS PROVIDED, THIS | | | COMMENT WILL STAY UNTIL THEWIND TUNNEL TEST IS A FINAL | | | VERSION. SHEET S0.00 THE WIND DESIGN CRITERIA IS SHOWN | | | IN VULT, PLEASE PROVIDE THE PRESSURES IN VASD SINCE ALL | | | PRODUCT APPROVALS ARE PRINTED IN VASD. | | | TABLE 1609.3. IS THIS PROJECT GOING TO DO WIND TUNNEL | | | TESTING TO REDUCE PRESSURES? | | | | | | 34) 2ND REQUEST, NOTE UPON WRITTEN REQUEST THIS CODE | | | ISSUE CAN BE A DEFERRED SUBMITTAL UNDER 107.3.4.2 BUT | | | THE PRESSURES HAVE TO BE INALLIZED BEFORE PERMIT | | | ISSUANCE. 2010 FBC-B 1609.1.2 PROTECTION OF OPENINGS, | | | 1609.6.4.41 COMPONENTS & CLADDING. | | | FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS RULE 9N-3 NOV. | | | 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION | | | SYSTEMS THAT WILL REQUIRE PRODUCT APPROVALS: | | | (31)(A) EXTERIOR DOORS. | | | (B) WINDOWS | | | (C) PANEL WALLS: STOREFRONTS, CURTAIN WALLS, WALL | | | LOUVERS, EFIS SYSTEMS, | | | (D) ROOFING PRODUCTS AND ASSEMBLIES | | | (E) SHUTTERS | | | (F) SKYLIGHTS | | | (G) EXTERIOR COOLER, FREEZERS & PRE-ENGINEERED A/C | | | STANDS | | | | | | 35) 2ND REQUEST, NOTE UPON WRITTEN REQUEST THIS CODE | | | ISSUE CAN BE A DEFERRED SUBMITTAL UNDER 107.3.4.2 BUT | | | THE PRESSURES HAVE TO BE INALLIZED BEFORE PERMIT | | | ISSUANCE. | | | 2010 FBC 107.3.4.1 PRODUCT APPROVALS. THOSE PRODUCTS | | | WHICH ARE REGULATED BY THE DCA RULE 9N-03 SHALL BE | | | REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF | | | RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL. | | | FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR | | | SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS, | | | SHOP DRAWINGS ETC.. | | | | | | 36) THE SMOKE CONTROL NARRATIVE APPEARS TO HAVE BEEN | | | PREPARED EARLY ON IN THE DEVELOPMENT OF THE PROJECT. | | | THERE ARE STATEMENTS WITHIN THE NARRATIVE THAT DO NOT | | | REFLECT THE ACTUAL CONFIGURATION OF THE BUILDING: | | | | | | 36A) PAGE 7 HEADING PRESSURE DIFFERENCES FLOOR TO | | | FLOOR. THE NARRATIVE STATE THE BASEMENT AND 1ST FLOOR | | | WILL NOT BE PRESSURIZED DASED ON THE BUILDING | | | CONFIGURATION THAT ALL STAIRS DISCHARGE TO THE | | | EXTERIOR. STAIR WELL # 2 BY THE LOBBY DOES NOT LEAD | | | DIRECTLY TO THE EXTERIOR OF THE BUILDING. | | | | | | 36B) PAGE 7 HEADING PRESSURE DIFFERENCES FLOOR TO | | | FLOOR. THE NARRATIVE STATE THE BASEMENT AND 1ST FLOOR | | | WILL NOT BE PRESSURIZED DASED ON THE BUILDING | | | CONFIGURATION THAT ALL STAIRS DISCHARGE TO THE | | | EXTERIOR. THE NARRATIVE INDICATES TO REVIEW THE NATURAL | | | METHODS OF POST FIRE SALVAGE OPERATION. PLEASE DIRECT | | | WHERE THE CODE ALLOWS FOR NATURAL METHODS OF POST FIRE | | | SALVAGE OPERATION IN LUE OF A ACTIVE SMOKE CONTROL | | | SYSTEM. | | | 909.20.3 909.20.3 NATURAL VENTILATION ALTERNATIVE DEALS | | | STRICTLY WITH THE STAIRWELLS NOT WHOLE FLOORS. | | | | | | THE SECOND ISSUE IS WITH THE BASEMENT NOT HAVING | | | NATURAL VENTILATION AND ALSO USING THE EXIT ACCESS | | | CORRIDOR TO STORE 25 + SOILED LAUNDRY CARTS WITHIN THE | | | EXIT ACCESS COORIDOR. SEE EARLIER COMMENT 4A). | | | | | | 36C) THIS IS A HIGH RISE BUILDING AND THIS STUDY HAS | | | NOT SHOWN HOW SMOKE WILL BE REMOVED FROM THE BASEMENT, | | | 1ST FLOOR, BALLROOMS WITH HIGH CEILINGS AS WELL AS THE | | | 2 STORY ATRIUM. 909.2 GENERAL DESIGN REQUIREMENTS. | | | BUILDINGS, STRUCTURES OR PARTS THEREOF REQUIRED BY THIS | | | CODE TO HAVE A SMOKE CONTROL SYSTEM OR SYSTEMS SHALL | | | HAVE SUCH SYSTEMS DESIGNED IN ACCORDANCE WITH THE | | | APPLICABLE REQUIREMENTS OF SECTION 909 AND THE | | | GENERALLY ACCEPTED AND WELL-ESTABLISHED PRINCIPLES OF | | | ENGINEERING RELEVANT TO THE DESIGN. THE CONSTRUCTION | | | DOCUMENTS SHALL INCLUDE SUFFICIENT INFORMATION AND | | | DETAIL TO ADEQUATELY DESCRIBE THE ELEMENTS OF THE | | | DESIGN NECESSARY FOR THE PROPER IMPLEMENTATION OF THE | | | SMOKE CONTROL SYSTEMS. THESE DOCUMENTS SHALL BE | | | ACCOMPANIED BY SUFFICIENT INFORMATION AND ANALYSIS TO | | | DEMONSTRATE COMPLIANCE WITH THESE PROVISIONS. | | | | | | 36D ) PAGE 12 DEALS WITH THE STAIRWELL SHAFTS THAT WILL | | | BE PRESSURIZED BY A FANS CONTROLLED BY A VARIABLE SPEED | | | DRIVE WITH RELIEF VENTS. WILL BE REQUIRED TO BE TESTED | | | IN ACCORDANCE WITH FBC-B 909.6.2./ 1008.1.2. | | | | | | 37) PLEASE PROVIDE CODE COMPLIANCE WITH: 2010 FBC-B [F] | | | 914.2 EQUIPMENT ROOM IDENTIFICATION. | | | FIRE PROTECTION EQUIPMENT SHALL BE IDENTIFIED IN AN | | | APPROVED MANNER. ROOMS CONTAINING CONTROLS FOR | | | AIR-CONDITIONING SYSTEMS, SPRINKLER RISERS AND VALVES | | | OR OTHER FIRE DETECTION, SUPPRESSION OR CONTROL | | | ELEMENTS SHALL BE IDENTIFIED FOR THE USE OF THE FIRE | | | DEPARTMENT. APPROVED SIGNS REQUIRED TO IDENTIFY FIRE | | | PROTECTION EQUIPMENT AND EQUIPMENT LOCATION SHALL BE | | | CONSTRUCTED OF DURABLE MATERIALS, PERMANENTLY INSTALLED | | | AND READILY VISIBLE. | | | | | | 38) EMERGENCY RESPONDER RADIO COVERAGE SHALL BE | | | PROVIDED IN ALL NEW BUILDINGS IN ACCORDANCE THE FLORIDA | | | FIRE PREVENTION CODE. | | | | | | 39) PLEASE PROVIDE COMPLIANCE WITH 2010 FBC-B [F] | | | 911.1.5 REQUIRED FEATURES. THE FIRE COMMAND CENTER | | | SHALL COMPLY WITH NFPA 72 AND SHALL CONTAIN THE | | | FOLLOWING FEATURES: 1-17. | | | | | | 40) THE SUBMITTED DOCUMENTS FOR 1ST REVIEW DID NOT | | | PROVIDE DOCUMENTS FOR THE ENERGY CODE FOR COMPLIANCE. | | | SEE 2010 FBC-ENERGY 103.2.1 & 103.2.3.1.2. | | | | | | A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW | | | COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | | THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR | | | PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2014-06-17 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2014-06-17 |
Time |
17:56 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-06-04 |
Time |
10:14 |
Sent To |
|
|
| Notes |
| 2014-06-05 06:31:33 | BUILDING PLAN REVIEW | | | PERMIT:14050111 | | | ADD: 600 OKEECHOBEE BLVD | | | CONT: COASTAL CONSTRUCTION | | | TEL: (561) 630-3770 | | | | | | 2010 FLORIDA BUILDING CODE W | | | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | | | THE PALM BEACH CONVENTION CENTER HILTON HOTEL | | | CONSTRUCTION OF NEW 400 ROOM HOTEL INCLUDING BALLROOMS, | | | RESTAURANT(S), MEETING SPACE, POOL DECK AND AMENITIES | | | | | | 1ST REVIEW | | | DATE: TUESDAY JUNE 17TH/ 2014 | | | | | | ACTION: DENIED | | | | | | 1) THE PERMIT DESCRIPTION LISTED ABOVE TO BUILD THE | | | HOTEL, POOL, POOL DECK & AMENITIES IS A INCLUSIVE | | | PACKAGE WITHIN THE SUBMITTED PLANS. THERE ARE CIVIL, | | | SITE, LANDSCAPING, IRRIGATION, GREASE INTERCEPTORS, | | | FUEL GAS, GENERATOR, FIRE SPRINKLER, FIRE ALARM, | | | LOWVOLTAGE, AWNINGS AND SIGNAGE PLANS WITHIN THE | | | SUBMITTED DOCUMENTS. | | | THESE TYPE OF ACTIVITIES REQUIRE A SEPARATE PERMIT | | | APPLICATION, REVIEW AND ASSOCIATED FEES. PLEASE BACK | | | OUT THE VALUE OF WORK TO BE COMPLETED UNDER EACH OF | | | THESE PERMITS SO THE BUILDING DEPARTMENT DOES NOT | | | CHARGE YOU TWICE FOR THESE SERVICES. 2010 WEST PALM | | | BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER | | | 1, ADMINISTRATION 105.1 PERMITS | | | | | | 2) THE APPLIED VALUE OF THE HOTEL IS VALUED AT | | | $35,000,000.00. THE CALCULATED VALUE OF THE PROJECT IS | | | $55,930,374.00 (312,216 SQ FT X $179.14 BUILDING ONLY, | | | NO SITE DEVELOPMENT) USING THE ICC BUILDING VALUATION | | | DATA FOR BOTH AUGUST 2013 & FEB, 2014. W P B | | | ADMINISTRTIVE CODE 108.2 SCHEDULE OF PERMIT FEES. ON | | | BUILDINGS, STRUCTURES, ELECTRICAL, GAS, MECHANICAL, AND | | | PLUMBING SYSTEMS OR ALTERATIONS REQUIRING A PERMIT, A | | | FEE FOR EACH PERMIT SHALL BE PAID AS REQUIRED, IN | | | ACCORDANCE WITH THE SCHEDULE ESTABLISHED BY THE | | | APPLICABLE GOVERNING AUTHORITY. | | | IF A BUILDING BREAK OUT OF SQUARE FOOTAGE UNDER EACH | | | OCCUPANCY CLASSIFICATION THIS NUMBER WOUD DROP SOME | | | WHAT, THIS WAS UNOT COMPLETED UNDER THE OCCUPANCY | | | CLASSIFICATION, PROBANLY BECAUSE OF UNLIMITED AREA FOR | | | A TYPE 1A BUILDING TYPE. | | | | | | 108.3* BUILDING PERMIT VALUATION. | | | IF, IN THE OPINION OF THE BUILDING OFFICIAL, THE | | | CLAIMED VALUATION OF BUILDING, ALTERATION, STRUCTURE, | | | ELECTRICAL, GAS, MECHANICAL, OR PLUMBING SYSTEMS | | | APPEARS TO BE UNDER ESTIMATED ON THE APPLICATION, THE | | | PERMIT SHALL BE DENIED. FOR PERMITTING PURPOSES, | | | VALUATION OF BUILDINGS AND SYSTEMS SHALL BE TOTAL | | | REPLACEMENT PURPOSES, VALUATION OF BUILDINGS AND | | | SYSTEMS SHALL BE THE TOTAL REPLACEMENT VALUE TO INCLUDE | | | STRUCTURAL, ELECTRICAL, PLUMBING, MECHANICAL, INTERIOR | | | FINISHES, NORMAL SITE WORK (EXCAVATION AND BACKFILL FOR | | | BUILDINGS), ARCHITECTURAL AND DESIGN FEES, MARKETING | | | COST, OVERHEAD AND PROFIT; EXCLUDING ONLY LAND VALUE. | | | VALUATION REFRENCES MAY INCLUDE THE LATEST PUBLISHED | | | DATA OF NATIONAL CONSTRUCTION COST ANALYSIS SERVICES | | | (MARSHALL-SWIFT, MEANS, ETC) WITH REGIONAL ADJUSTMENTS | | | FOR LOCATION AS PUBLISHED BY THE INTERNATIONAL CODE | | | CONGRESS. | | | | | | 3) 0210-A2.00: | | | | | | 3A) HEADING: PROJECT NAME LIST THE ADDRESS FORTHIS | | | PROJECT AS 901 FLORIDA AVENUE, PLEASE UPDATE THE | | | ADDRESS FOR THIS SITE TO 600 OKEECHOBEE BLVD. WEST PALM | | | BEACH, FL. (PALM BEACH COUNTY). | | | | | | 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING | | | CODE, CHAPTER 1, ADMINISTRATION, 107.2.1. CONSTRUCTION | | | DOCUMENTS SHALL BE OF SUFFICIENT CLARITY TO INDICATE | | | THE LOCATION, NATURE AND EXTENT OF THE WORK PROPOSED | | | AND SHOW IN DETAIL THAT IT WILL CONFORM TO THE | | | PROVISIONS OF THIS CODE AND RELEVANT LAWS, ORDINANCES, | | | RULES AND REGULATIONS, AS DETERMINED BY THE BUILDING | | | OFFICIAL. 2010 FBC-B 501.2 ADDRESS IDENTIFICATION. NEW | | | AND EXISTING BUILDINGS SHALL BE PROVIDED WITH APPROVED | | | ADDRESS NUMBERS OR LETTERS. | | | | | | 3B) HEADING: APPLICABLE CODES LIST THE (4) FLORIDA | | | BUILDING CODE-TEST PROTOCOLS FOR HIGH VELOCITY | | | HURRICANE ZONES- 2010 EDITION PLEASE NOTE THIS PORTION | | | OF THE CODE IS FOR BROWARD AND MIAMI-DADE COUNTIES. THE | | | ONLY REASON WE MAY LOOK AT THIS CODE IS IF A MIAMI-DADE | | | NOA NOTICE OF ACCEPTANCE REPORT IS SUBMITTED, THE | | | PRESCRIPTIVE REQUIREMENTS OF THIS CODE HAVE NOT AND CAN | | | NOT BE USED IN THIS JURISDICTION. | | | | | | 3C) HEADING CONSTRUCTION TYPE: LIST THE CODE SECTION | | | FOR OPEN PARIKNG GARAGES FBC 406.3.5 OPEN PARKING | | | GARAGES, PLEASE NOTE THE OPEN PARKING GARAGE IS ON | | | ANOTHER PROPERTY, WITH A SEPARATE ADDRESS. THIS | | | STRUCTURE WILL REQUIRE A SEPARATE PERMIT, REVIEW AND | | | ASSOCIATED FEES, FOR RECORD RECORDING PURPOSES. 2010 | | | WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING | | | CODE, CHAPTER 1, ADMINISTRATION, 105.1 PERMIT REQUIRED. | | | | | | 3D) THE FIRE RESISTANCE REQUIREMENTS- WALLS DOES NOT | | | PROVIDE THE RATING OF THE R-1 TENANT WALLS FOUND IN | | | SECTION 2010 FBC-B 439.2 FIRE PARTITIONS. | | | | | | PLEASE PROVIDE THE ACTUAL SQUARE FOOTAGE OF THE | | | BUILDING FOOT PRINT AS WELL AS THE SQUARE FOOTAGE FOR | | | THE TOWER AND THE TOTAL OVER ALL SQUARE FOOTAGE UNDER | | | ROOF, THESE ARE REQUIREMENTS FOR RECORD KEEPING AND | | | PRINTING OF CERTIFICATE OF OCCUPANCY. 107.2.1.3. | | | ADDITIONAL INFORMATION IS REQUIRED. | | | | | | 3E) SHEET A2.00 WHILE THIS SHEET PROVIDES TABLES FOR | | | OCCUPANCY CLASSIFICATION & OCCUPANT LOAD FACTORS THE | | | LIFR SAFETY SHEET DOES NOT PROVIDE OCCUPANT LOADS PER | | | FLOOR OR FOR THE TOTAL BUILDING. 2010 FBC-B 1004.1 | | | DESIGN OCCUPANT LOAD. | | | | | | 4) 0211-A2.01/ BASEMENT LEVEL: | | | | | | 4A) THE SERVICE COORIDOR B000 IN FRONT OF THE HOUSEMANS | | | STORAGE AND HOUSE KEEPING LAUNDRY IT APPEARS THERE IS | | | STORAGE CABINETS BEING STORED WITHIN THE CORRIDOR? | | | PLEASE EXPLAIN THE USAGE OF THIS AREA? 107.2.1.3 | | | ADDITIONAL INFORMATION IS REQUIRED. | | | | | | 4B) THE 2 ROOMS TO THE LEFT OF STORAGE ROOM B005 DO NOT | | | PROVIDE IDENTIFICATION, OR USAGE BUT INDICATE A 2 HR | | | FIRE RATING PLEASE IDENTIFY ROOMS AND OCCUPANCY. FBC-B | | | TABLE 508.4. | | | | | | 5) 0212-A2.02/ LEVEL 0100 | | | | | | 5A) IN THE LAST MEETING ALOT OF DISCUSSION TOOK PLACE | | | ABOUT THE CONNECTOR BETWEEN THE CONVENTION CENTER AND | | | THE HOTEL PROPERTY. ONE TOPIC WAS A DELUGE SYSTEM | | | REQUIRED FOR THE GLAZING. 3104.5 REQUIRES A 2 HR | | | SEPARATION, WALKWAYS SHALL BE SEPARATED FROM THE | | | INTERIOR OF THE BUILDING BY NOT LESS THAN 2 HOURS. | | | THERE ARE 4 EXCEPTIONS TO THE CODE. THERE ARE 4 | | | EXCEPTIONS TO THIS REQUIREMENT. | | | WITHIN EXCEPTION # 1 THERE IS 3 COMPONENTS: | | | 1). THE THE WALL IS CAPABLE OF RESISTING THE PASSAGE OF | | | SMOKE OR IS CONSTRUCTED OF A TEMPERED, WIRED OR | | | LAMINATED GLASS WALL AND DOORS SUBJECT TO THE | | | FOLLOWING: | | | 1.1. THE WALL OR GLASS SEPARATING THE INTERIOR OF THE | | | BUILDING FROM THE PEDESTRIAN WALKWAY SHALL BE PROTECTED | | | BY AN AUTOMATIC SPRINKLER SYSTEM IN ACCORDANCE WITH | | | SECTION 903.3.1.1 AND THE SPRINKLER SYSTEM SHALL | | | COMPLETELY WET THE ENTIRE SURFACE OF INTERIOR SIDES OF | | | THE WALL OR GLASS WHEN ACTUATED; | | | 1.2. THE GLASS SHALL BE IN A GASKETED FRAME AND | | | INSTALLED IN SUCH A MANNER THAT THE FRAMING SYSTEM WILL | | | DEFLECT WITHOUT BREAKING (LOADING) THE GLASS BEFORE THE | | | SPRINKLER OPERATES; AND | | | 1.3. OBSTRUCTIONS SHALL NOT BE INSTALLED BETWEEN THE | | | SPRINKLER HEADS AND THE WALL OR GLASS. | | | | | | THE ISSUE WITH THIS EXCEPTION STATES THE INTERIOR SIDE | | | OF THE GLASS SHALL BE PROTECTED WITH A SPRINKLER, WHEN | | | THE DOORS ARE OPEN THEY WILL NOT BE PROTECTED. | | | | | | 5B) ON THE EMERGENCY EXITING SIDE OF THE CONNECTOR THE | | | PLANS STATE THAT THE DOORWAY WILL ACCEPT 640 OCCUPANTS. | | | PLEASE REVIEW THE DOORWAY LEADING FROM THE JR. | | | BALLROOMS WITH A OCCUPANT LOAD OF 320 OCCUPANTS, THE | | | LEFT HAND DOOR BLOCKS ONE OF THE 4 EXIT DOORWAYS | | | REDUCING THE CLEAR WIDTH OF THE OPENING. THE OTHER | | | ISSUE WITH THIS CONFIGURATION IS THE SAME DOUBLE DOORS | | | LEADING FROM THE JR BALLROOMS, THE RIGHT HAND DOOR IS | | | PARTIALLY BLOCKED BY THE LEADING EDGE OF THE INSWING | | | DOOR, THERE IS ONLY A FOOT UNTIL THIS DOOR SWING | | | BECOMES AN OBSTRUCTION AGAIN DECREASING THE ABILITY TO | | | GET THE DECLARED OCCUPANT LOAD OUT THIS EXIT THE ACTUAL | | | OCCUPANT ACCESS LOADS ARE SKEWED. 2010 FBC-B 1005.1., | | | 1005.2 & FBC-B 1008.1.1.1. | | | | | | 5C) PLEASE PROVIDE IF THE LULA LIFT IS ON STANDBY | | | POWER? IF THE 3 HOUR FIRE DOOR IS ACTIVATED BY THE FIRE | | | ALARM AND IS CLOSED WILL A OCCUPANT IN THE LULA LIFT IF | | | LOCATED ON THE LOWER LEVEL BE ABLE TO OPERATE THE LIFT | | | TO THE UPPER LANDING TO BE ABLE TO ESCAPE FROM THE | | | BUILDING? FBC-B 403.4.7.2 (3) DOES NOT SAY ANYTHING | | | ABOUT LIFTS. | | | [F] 403.4.7.2 STANDBY POWER LOADS. | | | THE FOLLOWING ARE CLASSIFIED AS STANDBY POWER LOADS: 3. | | | STANDBY POWER SHALL BE PROVIDED FOR ELEVATORS IN | | | ACCORDANCE WITH SECTIONS 1006.2.4, 3003, 3007 AND 3008. | | | | | | 5D) WHAT APPEARS TO BE THE MENS RESTROOM, NOT LABELED, | | | BY THE WOMENS RESTROOM # 116 THIS RESTROOM HAS 4 | | | QUESTION MARKS WITHIN THE RESTROOM. | | | 107.2.1.3 ADDITIONAL INFORMATION IS REQUIRED. | | | | | | 5E) THE LAST MEETING THERE WAS DISCUSSION ABOUT THE | | | RATING OF THE COORIDOR IN FRONT OF THE RESTARAUNT 115. | | | THE CODE ALLOWS FOR 250 FEET (FBC-B TABLE 1016.1) | | | BEFORE HAVING TO REACH EITHER A PROTECTED EXIT FRONT | | | THE ENTRANCE OF THE BALL ROOM TO THE FRONT ENTRY THE | | | TRAVEL DISTANCE IS APPROXIMATELY 237 FEET. THE OTHER | | | ISSUE IS REQUIED EXIT ACCESS CORRIDORS, FBC-B 1018.1 | | | FOR AN ASSEMBLY OCCUPANCY IN A FIRE SPRINKLERED | | | BUILDING THERE IS NO FIRE RATING REQUIRED FOR THIS | | | CORRIDOR, YOU SEE THIS IN CONFIGURATION IN MALLS & | | | AIRPORT CONCOURSES AND TERMINAL. | | | | | | 5F) MEETING ROOM 2 & 3 WHEN COMBINED THE DIAGONAL | | | DISTANCE FROM CORNER TO CORNER APPEARS TO BE 57.2 FEET | | | ON THE DIAGONAL AND THE TO ENTRY DOORS ONLY BEING | | | 13'-0" APART CENTERLINE TO CENTER LINE NOT THE 18'-7 " | | | AS INDICATED ON THE PLANS. 2010 FBC-B 1015.2.1 EXCEP # | | | 2. | | | | | | 5G) NOT SHOWN ON THIS SHEET BUT A4.04 DOES SHOW THE | | | WEST PROPERTY LINE GOING THROUGH THE CABANAS AND POOL | | | ON THE WEST OF THE PROPERTY. | | | UNITY OF TITLE. THE PROPOSED BUILDING STRUCTURE | | | TRANSGRESSES LEGAL BOUNDARY LINES BETWEEN THE LOTS | | | WHICH COMBINE TO FORM 'THE SITE'. A 'UNITY OF TITLE' | | | SHALL BE | | | RECORDED AT THE COUNTY COURTHOUSE. SUBMIT A COPY OF THE | | | RECORDED 'UNITY OF OF TITLE' DOCUMENT SO THAT FBC TABLE | | | 601 BOUNDARY LINE REQUIREMENTS MAY BE DEEMED | | | NOT APPLICABLE. | | | SEE WEBSITE FOR APPLICATION: | | | HTTP://WWW.WPB.ORG/ENGINEERING/ENG_FORMS.PHP | | | "APPLICATION FOR UNITY OF TITLE" | | | HTTP://WWW.WPB.ORG/ENGINEERING/UPLOADS/2010-10-12-14-45 | | | -38-UNITYOFTITLE3.PDF | | | | | | 6) 0213-A-2.03 0200 LEVEL: | | | | | | 6A) SERVICE ELEVATOR LOBBY TO MAKE CHANGES AS PER THE | | | LAST MEETING AS DISCUSSED. | | | | | | 6B) THE MEETING ROOM # 1, BOARDROOM & MEETING ROOM # 2 | | | ARE TO BE REWORKED AS THE LAST MEETING ALLOWING EACH OF | | | THE ADJACENT ROOMS TO BE CONSIDERED INTERVENING ROOMS | | | AS PER FBC-B 1014.2 AND THE CORRIDOR DOORS THAT | | | SEPARATE THE 2 STORY ATRIUM BE MOVED CLOSER IN TO THE | | | ATRIUM AREA ALLOWING EGRESS FROM MEETING ROOM 1 & 2 | | | INTO THE RATED PORTION OF THE CORRIDOR ACCHIEVING CODE | | | COMPLIANCE WITH A HYBRID TYPE OF ATRIM WALL RATED 1 HR | | | AND ACHIEVING EXITING WITHOUT HAVING TO TRAVEL THROUGH | | | A UNPROTECTED ATRIUM. | | | | | | 7) 0214-A-2.04 / 0300 LEVEL. PLEASE REVIEW GUEST ROOM # | | | 346 IT APPEARS TO BE MISSING A LAVATORY. SEE DEFITITION | | | OF SLEEPING ROOM. | | | | | | 8)0221-A2.11 0100 LEVEL: GUEST ROOM #1046 IS A SHELL | | | ROOM, PLEASE PROVIDE A OCCUPANCY TYPE AND OCCUPANCY | | | LOAD FOR THIS UNIT, AS DEPICTED THIS MAY BE A ASSMBLY | | | OCCUPANCY, PLEASE PROVIDE ADDITIONAL DETAILS THIS ROOM | | | IS AN ADJOINING ROOM WITH SUITE # 1044 WHAT IS THE FIRE | | | RATING OF THE 2 COMMUNICATING DOORS. FBC-B 302.1, TABLE | | | 508.4 & TABLE 715.4. | | | | | | 9A) 0222-A2.12/ 1200 LEVEL ROOM 1136 THE EXECUTIVE | | | LOUNGE HAS A OCCUPANT LOAD OF 96 THIS IS AN ASSEMBLY | | | OCCUPANCY PLEASE PROVIDE A FURNATURE LATOUT. SHEET | | | A3.00 DOES NOT INCLUDE THIS ROOM IN THE PLUMBING | | | FIXTURE COUNT. DEPENDING ON THE USAGE THIS MAY BE | | | CONSIDERED EIHER AN A2 OR A3, IF CONSIDERED MORE AS A | | | LOUNGE A-2 THE WATER CLOSET RATIO WILL BE 1/40 | | | REQUIRING ADDITIONAL FIXTURES. | | | | | | 9B) 0222-A2.12/ 1200 LEVEL ROOM 1136 THE EXECUTIVE | | | LOUNGE, THERE IS A SMALL ROOM THAT NO INFORMATION HAS | | | BEEN PROVIDED, IS THIS FOR STORAGE, BAR OR KITCHEN TO | | | BE USED IN CONJUNCTION WITH THE LOUNGE? FBC-B 302.1. | | | | | | 10) A201 LIFE SAFETY BASEMENT PLAN VERSES A4.00 VERSES | | | DOOR SCHEDULE. | | | | | | 10A) THE DOMESTIC PUMP ROOM B002 IS SHOWN TO HAVE 2 HR | | | RATED WALLS WHERE AS THE DOOR SCHEDULE INDICATESS THE | | | DOOR TO BE A 45 MINUTE DOOR. | | | 2010 FBC-B TABLE 715.4/ 2HR RATED WALLS REQUIRES 1 1/2 | | | HR PROTECTIVES. | | | | | | 10B) THE STORE ROOM B005 IS INDICATED TO HAVE 1 HR | | | WALLS WHERE AS THE DOOR SCHEDULE INDICATES DOOR B005 TO | | | BE 90 MIN. FBC-B TABLE 715.4. | | | | | | 10C) THE LAUNDRY ROOM WALLS ARE SHOWN AS 1 HR RATED | | | WALLS WHEREAS THE DOOR SCHEDULE INDICATES B006 TO BE A | | | 90 MIN. DOOR. FBC-B TABLE 715.4. | | | | | | 10D) ROOM B013 SOILED LINEN ROOM IS ALSO THE | | | TERMINATION ROOM FOR THE LAUNDRY CHUTE THE WALLS ARE | | | INDICATED TO BE ONE HOUR WHERE AS THE DOORS SHOW AS 90 | | | MINUTE RATED. SEE 708.11 & 708.13.4. THE LAUNDRY CHUTE | | | MUST HAVE A 2 HOUR FIRE RATING AT THE END OF THE CHUTE | | | TO KEEP THE 1 HR FIRE RATING OF THE ROOM AND 45 MINUTE | | | OPENING PROTECTIVES. FBC-B TABLE 715.4. | | | | | | 10E) STAIR # 2, DOOR # B)16A BLOCKS THE STAIRWAY, 2010 | | | FBC-B 1008.1.1.1 PROJECTIONS INTO THE CLEAR WIDTH. | | | 1008.1.6 LANDINGS AT DOORS & 1009.5 STAIRWELL LANDINGS | | | BLOCKS THE REQUIRED LANDING LENGHT. | | | | | | 11) A2.02 VERSES A4.01 AND DOOR SCHEDULE: | | | | | | 11A) WALLS SHOWN ON A2.02 TO BE 1 HOUR FIRE RATED, | | | DOORS IDENTIFIED ON A4.01 AND DOOR SCHEDULE , DOORS | | | MISSING RATING IN THE DOOR SCHEDULE ARE | | | DOOR 121L, DOOR 121N & DOOR 121O. FBC-B TABLE 715.4 | | | | | | 11B) STAIR # 6 A 2 HOUR FIRE RATING AND DOOR SCHEDULE | | | MISSING 1 1/2 HR PROTECTIVE . FBC-B TABLE 715.4. | | | | | | 11C) ROOM POOL STORAGE IS A 1 HR RATING , DOOR SCHEDULE | | | MISSING FIRE RATING. FBC-B TABLE 715.4. | | | | | | 12) A2.02 VERSES A4.02 AND DOOR SCHEDULE: | | | | | | 12A) FPL VAULT 3 HR FIRE RATING THE DOOR SCHEDULE IS | | | MISSING THE1 1/2 HOUR FIRE RATING PER NEC 450.21. | | | | | | 13) SHEET A2.02 & A4.03, SHEET A4.03 COUNTING ROOM 112N | | | TABLE IS BLOCKING THE EGRESS DOOR. 2010 FBC-B | | | 1008.1.1.1 PROJECTIONS INTO THE CLEAR WIDTH. | | | | | | 14) SHEET A2.03 VS A4.07: | | | | | | 14A) SHEET A2.03 INDICATES A 1HR FIRE RATING BETWEEN | | | SLEEPING ROOMS IN ACCORDANCE WITH 709.1, PLEASE NOTE | | | 709.3 DOES NOT GIVE THE 1/2 HR REDUCTION IN WALL RATINS | | | SINCE THIS IS A TYPE IA CONSTRUCTION. THE EXCEPTION IS | | | FOR IIB, IIIB & VB CONSTRUCTION. THE COMMUNICATING | | | DOORS T12 WILL REQUIRE A 3/4 HR FIRE RATED DOOR. THE | | | DOOR SCHEDULE DOES NOT INDICATE ANY FIRE RATING. IF | | | TRYING TO USE 2/ 20 MIN DOORS, PLEASE SHOW A TESTED | | | ASSEMBLY MEETING THE 3/4 HR FIRE RATING. THIS COMMENT | | | WILL STAND FOR ALL FLOORS WITH SLEEPING ROOMS WITH | | | INTER-CONNECTING DOORS. | | | | | | 14B) DOOR # 219 NOTE # 20 INDICATES THE USE OF A CARD | | | READER TO GAIN ACCESS TO THE VERTICAL EXIT STAIRWAY. | | | SHEET A2.00 DOES NOT PROVIDE THE ACTUAL OCCUPANT LOADS | | | FOR ANY FLOORS PLEASE PROVIDE A MATRIX WITH OCCUPANT | | | LOADS PER FLOOR. FBC-B TABLE 1021.1 ONLY REQUIRES 2 | | | VERTICAL EXITS IF THE OCCUPANT LOAD IS 500 OR LESS, | | | REMOTENESS IS MET WITH STAIRWELL 1 &3 WITH THE | | | EXCEPTION OF THE TOP 3 FLOORS THERE THE CARD READER | | | WOULD NEED TO BE REMOVED. THE TOP FLOOR IS LESS THAN | | | 120'-0" IN HEIGHT, A FIRE SERVICE ELEVATOR (403.6.1 | | | REQUIRED AT 120 FT OCCUPIED FLOOR LEVEL) IS NOT | | | REQUIRED, THIS STAIR AND ELEVATOR COULD BE FOR BACK OF | | | HOUSE USE ONLY AND LIMITED TO EMPLOYEES ONLY. IF THE | | | ELEVATORS ARE TO BE FOR THE FIREMEN THEN THE ACCESS | | | CARD READERS WOULD NEED TO BE CONNECTED TO THE FIRE | | | COMMAND ROOM FOR THIER USE IN CASE OF EMERGENCY. | | | | | | 14C) THE OTHER ISSUE IS THE WAY THE ATRIUM WALL RATING | | | IS BEING CONSIDERED AS THE 1 HOUR WALL AT THE MEETING | | | ROOMS & BOARD ROOM. THE LAST MEETING IT WAS DISCUSSED | | | THAT THERE WOULD BE FIRE RATED DOOR OPENINGS AT EACH | | | SIDE OF THE ATRIUM AREA AND NEW COMMUNACATING DOORS | | | WITHIN THE BOARDROOM AND MEETING ROOMS TO CREATE | | | INTERVENING ROOMS AND A WAY FOR THE OCCUPANTS WITH THE | | | BOARD & MEETING ROOMS TO EXIT INTO A EXIT ACCESS | | | CORRIDOR. | | | TO DO THIS WILL THERE BE EXIT DIRECTIONAL SIGNS SHOWING | | | THIS AS A PART OF THE EGRESS PATH. THE OTHER QUESTION | | | IS THE A3 ASSEMBLY BOARD & MEETING ROOMS WILL REQUIRE A | | | INTERIOR FINISH FOR THE ROOMS AS A C AND THE CORRIDORS | | | AS A B, NOW WILL THE MEETING ROOMS BE CONSIDERED | | | CORRIDORS AND A B INTERIOR JUST AS THE CORRIDOR. NOTE | | | THE ASSEMBLY OCCUPANCY NOW WILL BE EXITING INTO THE | | | PORTION OF THE CORRIDOR FOR THE HOTEL ROOMS BUT WILL | | | NEED TO MAINTAIN THE FINISH FOR CORRIDORS AS FOR A3 | | | OCCUPANCY A B FINISH. TABLE 803.9. | | | | | | ROOMS 201- 217 HAVE THE TWO MEANS OF EGRESS, ROOMS 235 | | | THRU 250 WILL BE REQUIRED TO TRAVEL THRU THE MEETING | | | ROOMS TO MEET THE REQUIRED 2 MEANS OF EGRESS. FBC-B | | | TABLE 1018.1 FINSHES & TABLE 1021.1 MINIMUM EXITS. | | | | | | 14D) PLEASE SEE MEETING ROOM # 2 THE LOCAION OF THE ONE | | | HOUR RATED WALLTHE PURPLE LINE REPRESENTING THE RATED | | | WALL GOES AROUND THE DUCTWOK THAT COMES UP FROM THE 1ST | | | FLOOR 48"X15", THE MECHANICAL SHEET M-1.08 DOES NOT | | | SHOW A DAMPER IN IT. IT APPEARS THE FIRE RATING SHOULD | | | BE ONLY BEHIND THE DUCTWORK, THEN NO DAMPER WOULD BE | | | REQUIRED, 713.1.1 DUCTS AND AIR TRANSFER OPENINGS. | | | | | | 15) SHEET A2.03 VS A4.08: | | | | | | 15A) DETAIL 7/12.05 IS A FIRE EXTINGUISHER CABINET IN A | | | FIRE RATED WALL, THE DETAILS ON 12.05 DO NOT INDICATE | | | HOW THE FIRE RATINGS ARE TO BE MAINTAINED IN THE FIRE | | | RATED WALLS. ON SOME OF THE DETAILS FEC RATING SHOULD | | | BE SIMILAR TO WALL RATING. PLEASE PROVIDE HOW THE FIRE | | | RATING WILL BE MAINTAINED. | | | | | | 15B) SUITE OF ROOMS 240 & 247 DO HAVE INTERVENING ROOMS | | | AND DO MEET THE COMMON PATH OF TRAVEL OF 50 FT. ALL | | | SUITES WILL NEED TO MEET THE 50' COMMON PATH OF TRAVEL | | | FOR A R1 OCCUPANCY. FBC-B 1014.3 ECP # 6. | | | | | | 16) SHEET A4.20 SECTION THRU BUILDING A12.10 : | | | | | | 16A NOTES ON THE PLANS INDICATES THE USE OF ALUMINUM | | | COMPOSITE WALL PANELS, PLEASE PROVIDE DOCUMENTATION FOR | | | CODE COMPLIANCE WITH: 2010 FBC-B | | | 1407.2 EXTERIOR WALL FINISH. | | | MCM USED AS EXTERIOR WALL FINISH OR AS ELEMENTS OF | | | BALCONIES AND SIMILAR PROJECTIONS AND BAY AND ORIEL | | | WINDOWS TO PROVIDE CLADDING OR WEATHER RESISTANCE SHALL | | | COMPLY WITH SECTIONS 1407.4 THROUGH 1407.14. | | | | | | 16B) A12.10 DETAILS 1 & 8 BOTH INDICATE THE PERIMETER | | | SUN SCREEN , DETAIL 3 A12.09 ALSO A CLOSE UP OF THE | | | PERIMETER SUNSCREEN INDICATE THE USE OF | | | STEEL EMBEDS W/ NELSON BOLTS PER THE MANUFACTURERS | | | REQUIREMENTS. PLEASE PROVIDE ENGINEERING FOR THIS | | | SYSTEM THAT THE DESIGN AND ATTACHMENTS WILL MEET THE | | | WINDLOADS AND HEIGHT ADJUSTMENT FACTORS FOR THIS | | | ELEVATION, TO BE DESIGNED TO ASCE 7-10 .1609.1.1 | | | DETERMINATION OF WIND LOADS. | | | WIND LOADS ON EVERY BUILDING OR STRUCTURE SHALL BE | | | DETERMINED IN ACCORDANCE WITH CHAPTERS 26 THROUGH 30 OF | | | ASCE 7 OR THE PROVISIONS OF THE ALTERNATE ALL HEIGHTS | | | METHOD IN SECTION 1609.6. L | | | | | | 17A) SHEET # A5.00 THIS COMMENT WILL STAND FOR ALL | | | FLOORS. TYPICAL STANDARD KING. THE PLANS INDICATE A | | | WALL TAG 28C WITHIN THE BATHROOM THAT BACKS UP TO | | | ANOTHER SLEEPING UNIT. TENANT SEPARATION WALL NOT | | | RATED. FBC-B 709.1(6). THE WALL TAG 28C USES | | | ABBREVIATIONS GMGB AND SAFB NOT FOUND IN THE | | | ABBRREVIATIONS FOUND ON SHEET A0.02. PLEASE PROVIDE | | | WHAT THIS STAND FOR? ALSO SEE COMPLIANCE WITH 2010 | | | FBC-B 2509.2 BASE FOR TILE. | | | GLASS MAT WATER-RESISTANT GYPSUM BACKING PANELS, | | | DISCRETE NONASBESTOS FIBER-CEMENT INTERIOR SUBSTRATE | | | SHEETS OR NONASBESTOS FIBER-MAT REINFORCED CEMENT | | | SUBSTRATE SHEETS IN COMPLIANCE WITH ASTM C 1178, C 1288 | | | OR C 1325 AND INSTALLED IN ACCORDANCE WITH MANUFACTURER | | | RECOMMENDATIONS SHALL BE USED AS A BASE FOR WALL TILE | | | IN TUB AND SHOWER AREAS AND WALL AND CEILING PANELS IN | | | SHOWER AREAS. WATER-RESISTANT GYPSUM BACKING BOARD | | | SHALL BE USED AS A BASE FOR TILE IN WATER CLOSET | | | COMPARTMENT WALLS WHEN INSTALLED IN ACCORDANCE WITH | | | GA-216 OR ASTM C 840 AND MANUFACTURER RECOMMENDATIONS. | | | REGULAR GYPSUM WALLBOARD IS PERMITTED UNDER TILE OR | | | WALL PANELS IN OTHER WALL AND CEILING AREAS WHEN | | | INSTALLED IN ACCORDANCE WITH GA-216 OR ASTM C 840. | | | 2509.3 LIMITATIONS. WATER-RESISTANT GYPSUM BACKING | | | BOARD SHALL NOT BE USED IN THE FOLLOWING LOCATIONS: | | | 1. OVER A VAPOR RETARDER IN SHOWER OR BATHTUB | | | COMPARTMENTS. | | | 2. WHERE THERE WILL BE DIRECT EXPOSURE TO WATER OR IN | | | AREAS SUBJECT TO CONTINUOUS HIGH HUMIDITY. | | | 3. ON CEILINGS WHERE FRAME SPACING EXCEEDS 12 INCHES | | | (305 MM) O.C. FOR 1/2-INCH-THICK (12.7 MM) | | | WATER-RESISTANT GYPSUM BACKING BOARD AND MORE THAN 16 | | | INCHES (406 MM) O.C. FOR 5/8-INCH-THICK (15.9 MM) | | | WATER-RESISTANT GYPSUM BACKING BOARD. | | | | | | 17B) TYPICAL STANDARD KING TENANT SEPERATION WALL, WALL | | | TAG 5B DETAIL SHEET 11/1200 INDICATES FIRE RATING NOT | | | REQUIRED. FBC-B 709.1(6). | | | | | | 18) ) SHEET A5.11: | | | A) SHEET A5.11 VERSES A2.02 SEE WALL RATINGS OF 1 HOUR | | | WALL TAGS 7, 5C & 13 DO NOT SHOW THE 1 HOUR FIRE RATING | | | THAT THE LIFE SAFETY PLANS INDICATE. | | | | | | B) SHEET A5.11 0100 LEVEL BOH RESTROOM PLANS DOES NOT | | | MATCH UP WITH A2.02. WALL TYPE IDENTIFIED AS WALL TAG | | | 10A IS INDICATED AS A 2 HR WALL THIS WALL IS A COMMON | | | WALL TO THE FPL VAULT A 3 HR RATED WALL. WALL TAG 3B IS | | | INDICATED AS NOT RATED BY WALL TAG, A2.02 THE LIFE | | | SAFETY PLANS INDICATES THIS WALL TO BE A 1 HOUR FIRE | | | RATED WALL. 107.2.1.3 ADDITIONAL INFORMATION IS | | | REQUIRED, DISCREPANCY IN PLANS. | | | | | | C)SHEET A5.11 0100 LEVEL BOH RESTROOM PLANS DOES NOT | | | MATCH UP WITH A2.02. WALL TYPE IDENTIFIED AS WALL TAG | | | 3B IS INDICATED AS A NON-RATED WALL A2.02 LIFE SAFETY | | | SHEET A 1 HOUR RATED WALL. 107.2.1.3 DISCREPANCY IN | | | PLANS. ADDITIONAL INFORMATION IS REQUIRED. | | | | | | 19) SHEET A5.12 : | | | A) WALL TAGS 5A COMMON TO RESTROOM 124 AND PRE-FUNCTION | | | AREA ARE INDICATED NOT TO BE FIRE RATED WHERE AS A2.02 | | | LIFE SAFETY SHEET INDICATES THEM TO BE A 1 HOUR FIRE | | | RATING. 107.2.1.3 DISCREPANCY IN PLANS. ADDITIONAL | | | INFORMATION IS REQUIRED. | | | | | | B) POOL STORAGE ROOM 126, MISSING WALL TAG FOR THE | | | COMMON WALL WITH MENS RESTROOM 125, LIFE SAFETY SHOW | | | THE BLOCKWALL A 2 HR FIRE RATED WALL. 107.2.1.3 | | | DISCREPANCY IN PLANS. ADDITIONAL INFORMATION IS | | | REQUIRED. | | | | | | C) ) POOL STORAGE ROOM 126, MISSING WALL TAG FOR THE | | | COMMON WALL WITH MENS RESTROOM 125, LIFE SAFETY SHOW | | | THE BLOCKWALL A 2 HR FIRE RATED WALL. 107.2.1.3 | | | DISCREPANCY IN PLANS. ADDITIONAL INFORMATION IS | | | REQUIRED. | | | | | | 20) SHEET A5.15: | | | A) ADMINISTRATIVE OFFICES WALL IDENTIFICATION TAGS LIFE | | | SAFETY SHEET INDICATES THIS TO BE A 1 HOUR FIRE RATING | | | WHERE AS THE WALL IDENTIFICATION TAGS INDICATE A 2 HR. | | | 107.2.1.3.DISCREPANCY. ADDITIONAL INFORMATION IS | | | REQUIRED. | | | | | | B) SHEET A5.15 COMMON WALL OF SERVICE CORRIDOR AND | | | PAYMASTER AT WATER FOUNTAINS WALL IDENTIFICATION TAG | | | 28C. THIS WALL TAG INDICATES THIS A NON-FIRE RATED WALL | | | WHERE AS THE LIFE SAFETY PLAN SHOW THE ONE HOUR FIRE | | | RATING GOING THROUGH BEHIND THE WATER FOUNTAINS. | | | 107.2.1.3.DISCREPANCY. ADDITIONAL INFORMATION IS | | | REQUIRED. | | | | | | 21) SHEET A5.16 DOCK OFFICE WALL IDENTIFICATION TAGS 4A | | | & 2A BOTH INDICATE A 1 HOUR FIRERATING WHERE AS THE | | | LIFE SAFETY PLAN INDICATES THESE WALLS AS 2 HR FIRE | | | RATING. WINDOW IN A 2 HR RATED WALL 1 1/2 HOUR | | | PROTECTIVE. 107.2.1.3.DISCREPANCY. ADDITIONAL | | | INFORMATION IS REQUIRED. | | | | | | 22) SHEET A5.17: | | | A) THE FPL VAULT SWITH ROOMS DO NOT HAVE WALL | | | IDENTIFICATION TAGS, NOR DOES THE 2 SWITCH ROOMS HAVE | | | ROOM IDENTIFICATION NUMBERS. | | | 107.2.1.3.DISCREPANCY. ADDITIONAL INFORMATION IS | | | REQUIRED. SEE LIFE SAFETY PLAN FOR WALL FIRE RATING. | | | | | | B) NEITHER THE LIFE SAFETY PLAN NOR A5.17 PROVIDE | | | WHATTHE REQUIRED FIRE RATING OF THE FPL VAULT CEILING | | | IS? SEE A2.00 FPL TRANSFORMER VAULT 2008 NEC 450.21. | | | | | | C) SHEET A5.17 FPL VAULT DOOR # 143 DOOR HARDWARE | | | SCHEDULE UPDATE HARDWARE SEE SECTION FBC-B 1008.1.10 | | | PANIC AND FIRE EXIT HARDWARE. ELECTRICAL ROOMS WITH | | | EQUIPMENT RATED 1,200 AMPERES OR MORE AND OVER 6 FEET | | | (1829 MM) WIDE THAT CONTAIN OVERCURRENT DEVICES, | | | SWITCHING DEVICES OR CONTROL DEVICES WITH EXIT OR EXIT | | | ACCESS DOORS SHALL BE EQUIPPED WITH PANIC HARDWARE OR | | | FIRE EXIT HARDWARE. THE DOORS SHALL SWING IN THE | | | DIRECTION OF EGRESS TRAVEL. | | | | | | 23) A5.18: | | | WALL IDENTIFICATION TAGS ARE MISSING AND IDENTIFICATION | | | OF FIRE RATED WALLS. ADDITIONAL INFORMATION IS | | | REQUIRED. SEE LIFE SAFETY PLAN FOR WALL FIRE RATING | | | DISCREPANCY IN PLANS. 107.2.1.3. | | | | | | 24) A7.03, A7.05 & A7.10 THE STAIR FLOOR PLANS DO NOT | | | INDICATE THE REQUIRED STANDPIPES 2010 FBC-B 905.3. [F] | | | 403.3.1.1 RISER LOCATION. | | | SPRINKLER RISERS SHALL BE PLACED IN EXIT ENCLOSURES | | | THAT ARE REMOTELY LOCATED IN ACCORDANCE WITH SECTION | | | 1015.2. | | | | | | | | | 25) SHEET A7.15 THE LINEN CHUTE DETAIL AT THE 12TH | | | FLOOR THE 2 HOUR RATED SHAFT STOPS SHORT OF THE ROOF | | | DECK, YET THE LAUNDRY CHUTE CONTINUES THROUGH THE ROOF. | | | 708.12 ENCLOSURE AT THE TOP. A SHAFT ENCLOSURE THAT | | | DOES NOT EXTEND TO THE UNDERSIDE OF THE ROOF SHEATHING, | | | DECK OR SLAB OF THE BUILDING SHALL BE ENCLOSED AT THE | | | TOP WITH CONSTRUCTION OF THE SAME FIRE-RESISTANCE | | | RATING AS THE TOPMOST FLOOR PENETRATED BY THE SHAFT, | | | BUT NOT LESS THAN THE FIRE-RESISTANCE RATING REQUIRED | | | FOR THE SHAFT ENCLOSURE. | | | | | | 26) SHEET A2.10 SHOWS THE LAUNDRY CHUTE LOCATED ON THE | | | GRID LINES X.1 JUST NORTH & Y.2 CENTERED ON THE GRID | | | LINE WHICH IS LOCATED IN THE MAIDS ROOM. | | | FLOORS 10-12 SEE SHEET A2.11 THE LAUBDRY CHUTE IS | | | OFFSET TO THE NORTHEAST OR TO THE EAST OF GRID LINE Y.2 | | | . THE PLANS SHOW THE ACCESS TO THE ACCESS CHUTE DOOR | | | LOCATED WITH THE CORRADOR. PLEASE CONFORM WITH: | | | | | | 2010 FBC-B 708.13.3 REFUSE AND LAUNDRY CHUTE ACCESS | | | ROOMS. | | | ACCESS OPENINGS FOR REFUSE AND LAUNDRY CHUTES SHALL BE | | | LOCATED IN ROOMS OR COMPARTMENTS ENCLOSED BY NOT LESS | | | THAN 1-HOUR FIRE BARRIERS CONSTRUCTED IN ACCORDANCE | | | WITH SECTION 707 OR HORIZONTAL ASSEMBLIES CONSTRUCTED | | | IN ACCORDANCE WITH SECTION 712, OR BOTH. OPENINGS INTO | | | THE ACCESS ROOMS SHALL BE PROTECTED BY OPENING | | | PROTECTIVES HAVING A FIRE PROTECTION RATING OF NOT LESS | | | THAN 3/4 HOUR. DOORS SHALL BE SELF- OR | | | AUTOMATIC-CLOSING UPON THE DETECTION OF SMOKE IN | | | ACCORDANCE WITH SECTION 715.4.8.3. | | | | | | 27) SHEET A7.15 THE LINEN CHUTE DETAILS DO NOT MENTION | | | THE REQUIREMENT OR ANY ALLOWANCES FOR FIRE SPRINKLERS | | | IN THE LINEN CHUTE. THE FIRE SPRINKLER SHEETS ONLY | | | PROVIDE A DEAIL ON FP0.01 INDICATING SERVICE CHUTE | | | DETAIL. | | | 708.13.6 AUTOMATIC SPRINKLER SYSTEM. | | | AN APPROVED AUTOMATIC SPRINKLER SYSTEM SHALL BE | | | INSTALLED IN ACCORDANCE WITH SECTION 903.2.11.2 F] | | | 903.2.11.2 RUBBISH AND LINEN CHUTES. | | | AN AUTOMATIC SPRINKLER SYSTEM SHALL BE INSTALLED AT THE | | | TOP OF RUBBISH AND LINEN CHUTES AND IN THEIR TERMINAL | | | ROOMS. CHUTES EXTENDING THROUGH THREE OR MORE FLOORS | | | SHALL HAVE ADDITIONAL SPRINKLER HEADS INSTALLED WITHIN | | | SUCH CHUTES AT ALTERNATE FLOORS. CHUTE SPRINKLERS SHALL | | | BE ACCESSIBLE FOR SERVICING. | | | | | | THE LAUNDRY CHUTE DETAIL SHEET ALSO DOESN'T MAKE | | | REFERANCE TO THE REQUIREMENT FOR CHUTE SPRINKLERS SHALL | | | BE ACCESSIBLE FOR SERVICING. | | | | | | 28A) SHEET A7.03, A7.07 & A7.10 THE STAIR PLANS AND | | | NOTES DO NOT INDICATE COMPLIANCE WITH 2010 FBC-B | | | 403.5.5 AND SECION 1024 LUMINOUS EGRESS PATH MARKINGS. | | | | | | 28B) THESE SHEETS ALSO ARE MISSING COMPLIANCE WITH | | | 403.5.3.1 STAIRWAY COMMUNICATION SYSTEMS. | | | | | | 29) SHEET A12.20 DETAILS 4A & 4B SHOW THE USE OF PIING | | | PILE CAPS AND GRADE BEAMS, AREN'T THE PILES BEING | | | ELIMINATED? 107.2.1.3 ADDITIONAL INFORMATION IS | | | REQUIRED. | | | | | | 30) SHEET A12.22 DETAIL # 1 SPRAY APPLIED | | | FIRE-RESISTANCE MATERIALS INDICATES SEE DETAIL ON | | | A12.04 SPRAY APPLIED RESISTIVE MATERIAL. PLEASE PROVIDE | | | COMPLIANCE WITH FBC-B 403.2.4 SPRAYED FIRE-RESISTANT | | | MATERIALS (SFRM). | | | THE BOND STRENGTH OF THE SFRM INSTALLED THROUGHOUT THE | | | BUILDING SHALL BE IN ACCORDANCE WITH TABLE | | | 403.2.4.HEIGHT OF BUILDING (A FOOTNOTE) | | | SFRM MINIMUM BOND STRENGTH UP TO 420 FEET 430 PSF (A) | | | ABOVE THE LOWEST LEVEL OF FIRE DEPARTMENT VEHICLE | | | ACCESS. | | | | | | 31) SHEET A12.09.2 ALUMINUM FRAMED GLASS CANOPY DETAILS | | | PLEASE PROVIDE COMPLIANCE WITH GLAZING REQUIREMENTS | | | FOUND UNDER THE 2010 FBC-B | | | 2405.2 ALLOWABLE GLAZING MATERIALS AND LIMITATIONS. | | | SLOPED GLAZING SHALL BE ANY OF THE FOLLOWING MATERIALS, | | | SUBJECT TO THE LISTED LIMITATIONS. | | | 1. FOR MONOLITHIC GLAZING SYSTEMS, THE GLAZING MATERIAL | | | OF THE SINGLE LIGHT OR LAYER SHALL BE LAMINATED GLASS | | | WITH A MINIMUM 30-MIL (0.76 MM) POLYVINYL BUTYRAL (OR | | | EQUIVALENT) INTERLAYER, WIRED GLASS, LIGHT-TRANSMITTING | | | PLASTIC MATERIALS MEETING THE REQUIREMENTS OF SECTION | | | 2607, HEAT-STRENGTHENED GLASS OR FULLY TEMPERED GLASS. | | | 2. FOR MULTIPLE-LAYER GLAZING SYSTEMS, EACH LIGHT OR | | | LAYER SHALL CONSIST OF ANY OF THE GLAZING MATERIALS | | | SPECIFIED IN ITEM 1 ABOVE. | | | ANNEALED GLASS IS PERMITTED TO BE USED AS SPECIFIED | | | WITHIN EXCEPTIONS 2 AND 3 OF SECTION 2405.3. | | | FOR ADDITIONAL REQUIREMENTS FOR PLASTIC SKYLIGHTS, SEE | | | SECTION 2610. GLASS-BLOCK CONSTRUCTION SHALL CONFORM TO | | | THE REQUIREMENTS OF SECTION 2101.2.5. | | | | | | 32)) SHEET A5.04 PLEASE REVIEW THE HOSPITALITY SUITES | | | DETAIL 1 & 2 NEITHER OF THESE SUITES SHOW UP ON THE | | | FLORIDA ACCESSIBLITY ROOM MATRIX. PLEASE REVIEW 2010 FL | | | ACCESSIBILITY SECTION 224.5 THESE UNITS DO HAVE | | | KITCHENS IN THEM WHERE AS NONE OF THE OTHER UNITS IN | | | THE MATRIX INDICATE SUITES WITH KITCHENS NOR ARE THE | | | BATHROOMS ACCESSIBLE. | | | | | | 33) SHEET S0.00 THE WIND DESIGN CRITERIA IS SHOWN IN | | | VULT, PLEASE PROVIDE THE PRESSURES IN VASD SINCE ALL | | | PRODUCT APPROVALS ARE PRINTED IN VASD. | | | TABLE 1609.3. IS THIS PROJECT GOING TO DO WIND TUNNEL | | | TESTING TO REDUCE PRESSURES? | | | | | | 34) 2010 FBC-B 1609.1.2 PROTECTION OF OPENINGS, | | | 1609.6.4.41 COMPONENTS & CLADDING. | | | FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS RULE 9N-3 NOV. | | | 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION | | | SYSTEMS THAT WILL REQUIRE PRODUCT APPROVALS: | | | (31)(A) EXTERIOR DOORS. | | | (B) WINDOWS | | | (C) PANEL WALLS: STOREFRONTS, CURTAIN WALLS, WALL | | | LOUVERS, EFIS SYSTEMS, | | | (D) ROOFING PRODUCTS AND ASSEMBLIES | | | (E) SHUTTERS | | | (F) SKYLIGHTS | | | (G) EXTERIOR COOLER, FREEZERS & PRE-ENGINEERED A/C | | | STANDS | | | | | | 35) 2010 FBC 107.3.4.1 PRODUCT APPROVALS. THOSE | | | PRODUCTS WHICH ARE REGULATED BY THE DCA RULE 9N-03 | | | SHALL BE REVIEWED AND APPROVED IN WRITING BY THE | | | DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR | | | JURISDICTIONAL APPROVAL. | | | FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR | | | SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS, | | | SHOP DRAWINGS ETC.. | | | | | | 36) SHEET M5.1 SMOKE CONTROL NOTES UNDER THE HEADING | | | GENERAL , SMOKE CONTROL NOTES AND SMOKE CONTROL | | | SEQUENCE THE NOTES DO NOT MAKE IT CLEAR HOW THE SMOKE | | | CONTROL SYSTEM IS TO OPERATE. | | | 2010 FBC-B 03.4.6 SMOKE REMOVAL.SMOKE CONTROL SHALL BE | | | PROVIDED IN ACCORDANCE WITH SECTION 909. SECTION 909 | | | PROVIDES VARIOUS METHODS OF COMPLYING WITH SMOKE | | | CONTROL: | | | 909.6 PRESSURIZATION METHOD. | | | 909.7 AIRFLOW DESIGN METHOD. | | | 909.8 EXHAUST METHOD. | | | 909.9 DESIGN FIRE. | | | | | | [F] 909.2 GENERAL DESIGN REQUIREMENTS. | | | BUILDINGS, STRUCTURES OR PARTS THEREOF REQUIRED BY THIS | | | CODE TO HAVE A SMOKE CONTROL SYSTEM OR SYSTEMS SHALL | | | HAVE SUCH SYSTEMS DESIGNED IN ACCORDANCE WITH THE | | | APPLICABLE REQUIREMENTS OF SECTION 909 AND THE | | | GENERALLY ACCEPTED AND WELL-ESTABLISHED PRINCIPLES OF | | | ENGINEERING RELEVANT TO THE DESIGN. THE CONSTRUCTION | | | DOCUMENTS SHALL INCLUDE SUFFICIENT INFORMATION AND | | | DETAIL TO ADEQUATELY DESCRIBE THE ELEMENTS OF THE | | | DESIGN NECESSARY FOR THE PROPER IMPLEMENTATION OF THE | | | SMOKE CONTROL SYSTEMS. THESE DOCUMENTS SHALL BE | | | ACCOMPANIED BY SUFFICIENT INFORMATION AND ANALYSIS TO | | | DEMONSTRATE COMPLIANCE WITH THESE PROVISIONS. | | | | | | [F] 909.3 SPECIAL INSPECTION AND TEST REQUIREMENTS. | | | IN ADDITION TO THE ORDINARY INSPECTION AND TEST | | | REQUIREMENTS WHICH BUILDINGS, STRUCTURES AND PARTS | | | THEREOF ARE REQUIRED TO UNDERGO, SMOKE CONTROL SYSTEMS | | | SUBJECT TO THE PROVISIONS OF SECTION 909 SHALL UNDERGO | | | SPECIAL INSPECTIONS AND TESTS SUFFICIENT TO VERIFY THE | | | PROPER COMMISSIONING OF THE SMOKE CONTROL DESIGN IN ITS | | | FINAL INSTALLED CONDITION. THE DESIGN SUBMISSION | | | ACCOMPANYING THE CONSTRUCTION DOCUMENTS SHALL CLEARLY | | | DETAIL PROCEDURES AND METHODS TO BE USED AND THE ITEMS | | | SUBJECT TO SUCH INSPECTIONS AND TESTS. SUCH | | | COMMISSIONING SHALL BE IN ACCORDANCE WITH GENERALLY | | | ACCEPTED ENGINEERING PRACTICE AND, WHERE POSSIBLE, | | | BASED ON PUBLISHED STANDARDS FOR THE PARTICULAR TESTING | | | INVOLVED. | | | | | | [F] 909.4 ANALYSIS. | | | A RATIONAL ANALYSIS SUPPORTING THE TYPES OF SMOKE | | | CONTROL SYSTEMS TO BE EMPLOYED, THEIR METHODS OF | | | OPERATION, THE SYSTEMS SUPPORTING THEM AND THE METHODS | | | OF CONSTRUCTION TO BE UTILIZED SHALL ACCOMPANY THE | | | SUBMITTED CONSTRUCTION DOCUMENTS AND SHALL INCLUDE, BUT | | | NOT BE LIMITED TO, THE ITEMS INDICATED IN SECTIONS | | | 909.4.1 THROUGH 909.4.6. | | | | | | 37) PLEASE PROVIDE CODE COMPLIANCE WITH: 2010 FBC-B [F] | | | 914.2 EQUIPMENT ROOM IDENTIFICATION. | | | FIRE PROTECTION EQUIPMENT SHALL BE IDENTIFIED IN AN | | | APPROVED MANNER. ROOMS CONTAINING CONTROLS FOR | | | AIR-CONDITIONING SYSTEMS, SPRINKLER RISERS AND VALVES | | | OR OTHER FIRE DETECTION, SUPPRESSION OR CONTROL | | | ELEMENTS SHALL BE IDENTIFIED FOR THE USE OF THE FIRE | | | DEPARTMENT. APPROVED SIGNS REQUIRED TO IDENTIFY FIRE | | | PROTECTION EQUIPMENT AND EQUIPMENT LOCATION SHALL BE | | | CONSTRUCTED OF DURABLE MATERIALS, PERMANENTLY INSTALLED | | | AND READILY VISIBLE. | | | | | | 38) EMERGENCY RESPONDER RADIO COVERAGE SHALL BE | | | PROVIDED IN ALL NEW BUILDINGS IN ACCORDANCE THE FLORIDA | | | FIRE PREVENTION CODE. | | | | | | 39) PLEASE PROVIDE COMPLIANCE WITH 2010 FBC-B [F] | | | 911.1.5 REQUIRED FEATURES. THE FIRE COMMAND CENTER | | | SHALL COMPLY WITH NFPA 72 AND SHALL CONTAIN THE | | | FOLLOWING FEATURES: 1-17. | | | | | | 40) THE SUBMITTED DOCUMENTS FOR 1ST REVIEW DID NOT | | | PROVIDE DOCUMENTS FOR THE ENERGY CODE FOR COMPLIANCE. | | | SEE 2010 FBC-ENERGY 103.2.1 & 103.2.3.1.2. | | | | | | A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW | | | COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | | THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR | | | PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | DEVELOPMENT SERVICES HOME PAGE | | | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP | | | | | | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS | | | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS | | | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO | | | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE | | | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. | | | | | | MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF | | | FLORIDA SAVING LIVES AND PROPERTY SINCE 1953 | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2014-08-20 |
|
|
Cont ID |
|
| Sent By |
dhayes |
Date |
2014-08-20 |
Time |
16:26 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
2014-08-13 |
Time |
16:22 |
Sent To |
|
|
| Notes |
| 2014-08-15 12:48:02 | DATE: 8/15/2014 | | | PROJECT: WPB HILTON CONVENTION CENTER HOTEL | | | PERMIT#: 14050111 | | | CODE: 2008 EDITION OF THE NEC | | | 2010 EDITION OF THE FBC | | | 2010 WPB AMENDMENTS TO THE FBC, CHAPTER 1, | | | ADMINISTRATION, 2012 FBC SUPPLEMENTS. | | | | | | 2ND ELECTRICAL PLAN REVIEW | | | ACTION: PROVISO | | | | | | 1) SHEET E1-01 | | | A. ELECTRICAL RM, FIRE PUMP RM, ELEVATOR EQUIPMENT ROOM | | | MECHANICAL RM AND SIMILAR ROOMS, SHOULD NOT HAVE AN OS | | | SWITCH DUE TO FBC 505.2.2 EXCEPTION #4 SPACES WHERE AN | | | AUTOMATIC SHUTOFF WOULD ENDANGER OCCUPANT SAFETY OR | | | SECURITY. | | | | | | 2) SHEET E1.09 | | | A. 680.10 UNDERGROUND WIRING LOCATION. UNDERGROUND | | | WIRING SHALL NOT BE PERMITTED UNDER THE POOL OR WITHIN | | | THE AREA EXTENDING 1.5 M (5 FT) HORIZONTALLY FROM THE | | | INSIDE WALL OF THE POOL UNLESS THIS WIRING IS NECESSARY | | | TO SUPPLY POOL EQUIPMENT PERMITTED BY THIS ARTICLE. | | | WHERE SPACE LIMITATIONS PREVENT WIRING FROM BEING | | | ROUTED A DISTANCE 1.5 M (5 FT) OR MORE FROM THE POOL, | | | SUCH WIRING SHALL BE PERMITTED WHERE INSTALLED IN | | | COMPLETE RACEWAY SYSTEMS OF RIGID METAL CONDUIT, | | | INTERMEDIATE METAL CONDUIT, OR A NONMETALLIC RACEWAY | | | SYSTEM. ALL METAL CONDUIT SHALL BE CORROSION RESISTANT | | | AND SUITABLE FOR THE LOCATION. THE MINIMUM COVER DEPTH | | | SHALL BE AS GIVEN IN TABLE 680.10. | | | B. 680.22 (5)(C)(1) MEASUREMENTS. IN DETERMINING THE | | | DIMENSIONS IN THIS SECTION ADDRESSING RECEPTACLE | | | SPACING THE DISTANCE TO BE MEASURED SHALL BE THE | | | SHORTEST PATH THE SUPPLY CORD OF AN APPLIANCE CONNECTED | | | TO THE RECEPTACLE WOULD FOLLOW WITHOUT PIERCING A | | | FLOOR, WALL, CEILING, DOORWAY WITH HINGED OR SLIDING | | | DOOR, WINDOW OPENING, OR OTHER EFFECTIVE PERMANENT | | | BARRIER. | | | (C) LUMINAIRES, LIGHTING OUTLETS, AND CEILING-SUSPENDED | | | (PADDLE) FANS. | | | (1) NEW OUTDOOR INSTALLATION CLEARANCES. IN OUTDOOR | | | POOL AREAS, LUMINAIRES, LIGHTING OUTLETS, AND CEILING | | | SUSPENDED (PADDLE) FANS INSTALLED ABOVE THE POOL OR THE | | | AREA EXTENDING 1.5 M (5 FT) HORIZONTALLY FROM THE | | | INSIDE WALLS OF THE POOL SHALL BE INSTALLED AT A HEIGHT | | | NOT LESS THAN 3.7 M (12 FT) ABOVE THE MAXIMUM WATER | | | LEVEL OF THE POOL. | | | | | | 3) SHEET E4.01 | | | A. PROVIDE SAFETY LABELING FOR ARC FLASH PROTECTION FOR | | | THE PANEL BOARDS AND MAIN DISCONNECTING MEANS. NEC | | | 110.16, 110.22 | | | B. IDENTIFY ALL SWITCHGEAR. SEE NEC 110.22 | | | IDENTIFICATION OF DISCONNECTING MEANS. AND 240.86(A) | | | (A) GENERAL. EACH DISCONNECTING MEANS SHALL BE LEGIBLY | | | MARKED TO INDICATE ITS PURPOSE UNLESS LOCATED AND | | | ARRANGED SO THE PURPOSE IS EVIDENT. THE MARKING SHALL | | | BE OF SUFFICIENT DURABILITY TO WITHSTAND THE | | | ENVIRONMENT INVOLVED. | | | (B) NEC 230.95 GROUNDFAULT PROTECTION OF EQUIPMENT | | | SHALL BE PROVIDED FOR SOLIDLY GROUNDED WYE ELECTRIC | | | SERVICES OF MORE THAN 150 VOLTS TO GROUND BUT NOT | | | EXCEEDING 600 VOLTS PHASE-TO-PHASE FOR EACH SERVICE | | | DISCONNECT RATED 1000 AMPERES OR MORE. | | | (C) NEC 230.95 (C) THE GROUND-FAULT PROTECTION SYSTEM | | | SHALL BE PERFORMANCE TESTED WHEN FIRST INSTALLED ON | | | SITE. THE TEST SHALL BE CONDUCTED IN ACCORDANCE WITH | | | INSTRUCTIONS THAT SHALL BE PROVIDED WITH THE EQUIPMENT. | | | A WRITTEN RECORD OF THIS TEST SHALL BE MADE AND SHALL | | | BE AVAILABLE TO THE AUTHORITY HAVING JURISDICTION. | | | (D) ENGINEERED SERIES COMBINATION SYSTEMS. | | | NEC 240.86 SERIES RATINGS. WHERE A CIRCUIT BREAKER IS | | | USED ON A CIRCUIT HAVING AN AVAILABLE FAULT CURRENT | | | HIGHER THAN THE MARKED INTERRUPTING RATING BY BEING | | | CONNECTED ON THE LOAD SIDE OF AN ACCEPTABLE OVERCURRENT | | | PROTECTIVE DEVICE HAVING A HIGHER RATING, THE CIRCUIT | | | BREAKER SHALL MEET THE REQUIREMENTS SPECIFIED IN (A) OR | | | (B), AND (C) | | | C. PROVIDE VERIFICATION ON THE PLANS THAT THE FIRE PUMP | | | FEEDERS, CIRCUIT CONDUCTORS, GENERATOR CONTROL WIRING | | | AND PUMP WIRING ARE APPROPRIATELY FIRE PROTECTED. | | | INDICATE THE FIRE RATING AND MATERIAL REQUIRED. NEC | | | 695.6, 695.14 | | | D. VERIFY THE FIRE PUMP FEEDERS ARE SIZED WITH A RATING | | | NOT LESS THAN 125% OF THE SUM OF THE FIRE PUMP MOTOR, | | | PRESSURE MAINTENANCE MOTORS AND 100 PERCENT OF THE | | | ACCESSORIES. VERIFY THE MAXIMUM VOLTAGE DROP IS NOT | | | MORE THAN 15 % BELOW NORMAL STARTING AND 5% BELOW WHEN | | | THE MOTOR IS OPERATING AT 115% OF THE FULL ?LOAD | | | CURRENT RATING. NEC 695.6, 695.7 | | | INDICATE THAT ALL WIRING FOR EMERGENCY LOADS WILL BE | | | IDENTIFIED WITH PERMANENT MARKINGS AND KEPT ENTIRELY | | | INDEPENDENT OF ALL OTHER WIRING AND EQUIPMENT. NEC | | | 700.9 | | | E. PROVIDE SIGNS AT THE SERVICE INDICATING THE TYPE AND | | | LOCATION OF THE ON SITE EMERGENCY POWER SOURCE. NEC | | | 700.8 | | | | | | 4) SHEET E5.01, E5.04 | | | PANEL 2CH, PANEL M1, AND POSSIBLY OTHERS NOT NOTED IN | | | THIS REVIEW INDICATE MORE CIRCUITS THAN THE PANEL BOARD | | | IS RATED FOR. 2, AND 3 POLE CIRCUITS SHALL BE | | | CONSIDERED 2 OR 3 POLE DEVICES. IDENTIFY ALL | | | PANELBOARDS ACCORDINGLY NEC 408.54. REVISE PANEL | | | SCHEDULES TO COMPLY. | | | | | | 5) GENERAL NOTES: | | | A. PROVIDE MANUFACTURER DATA SHEETS FOR FLOOR BOXES, | | | B. A SEPARATE PERMIT APPLICATIONS ACCOMPANIED BY | | | MANUFACTURERS EQUIPMENT SUBMITTALS, AND SHOP DRAWINGS | | | ARE REQUIRED FOR GENERATOR, SWIMMING POOL, FIRE ALARM, | | | SECURITY, CCTV, DATA/COM, NETWORK, STRUCTURED CABLING, | | | AUDIO/VIDEO, AND SIGNAGE. | | | | | | DAVID HAYES, ELECTRICAL PLANS EXAMINER, PX3421, | | | 561-805-6717 OR [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2014-06-11 |
|
|
Cont ID |
|
| Sent By |
albarran |
Date |
2014-06-11 |
Time |
11:39 |
Rev Time |
0.00 |
| Received By |
albarran |
Date |
2014-06-03 |
Time |
09:07 |
Sent To |
|
|
| Notes |
| 2014-06-11 11:41:29 | PERMIT 14050111, WEST PALM BEACH CONVENTION CENTER | | | HILTON HOTEL | | | THE FIRST ELECTRICAL REVIEW FAILED AS LISTED BELOW: | | | THE FOLLOWING IS A LIST OF THE CHANGEMARKS, NOTES AND | | | CORRECTIONS ENTERED AS RESULT OF THE ELECTRICAL REVIEW | | | ON THE ABOVE MENTIONED PERMIT. THE DIGITAL SET HAS BEEN | | | MARKED WITH EVERY NOTE AND COMMENT THAT APPEARS BELOW. | | | FOR EASE OF CORRECTING, PLEASE NOTE THAT THE COMMENTS | | | ARE ARRANGED WITH PAGE NUMBERS AND THE RESPECTIVE | | | CHANGEMARK NUMBER PER PAGE. | | | PAGE E0.00 | | | 1. THE ADOPTED VERSION OF THE NEC AT THE TIME OF THIS | | | REVIEW IS THE 2008 EDITION, WHICH IS THE ONE THAT SHALL | | | APPLY. | | | 2. NEED MORE SPECIFICS ON THE WIND LOAD CRITERIA. IS | | | THE REFERENCE TO ULTIMATE OR NOMINAL? | | | 3. CORRECT THIS QUOTE/REFERRAL TO NEC SECTION 368.6 AS | | | IT DOES NOT EXIST IN THE 2008 EDITION OF THE NEC. | | | 4. A SEPARATE PERMIT AND SHOP DRAWINGS ARE REQUIRED FOR | | | THE FIRE ALARM INSTALLATION. | | | PAGE E1.01 | | | 1. LIGHTING CONTROL TO BE IN ACCORDANCE WITH THE | | | REQUIREMENTS OF 2010 FLORIDA BLDG. CODE - ENERGY | | | CONSERVATION, SEC. 505. | | | PAGE E1.06, E1.07 | | | 1. LIGHTING CONTROL TO BE IN ACCORDANCE WITH THE | | | REQUIREMENTS OF 2010 FLORIDA BLDG. CODE - ENERGY | | | CONSERVATION, SEC. 505. | | | PAGE E1.22 | | | 1. PER NEC 406.8, ALL 15 AND 20 AMPERE, 125 AND 250 | | | VOLT NON-LOCKING RECEPTACLES SHALL BE LISTED | | | WEATHER-RESISTANT TYPE. | | | PAGE E2.00, E2.01, E2.03, E2.04 | | | 1. THE 2010 EDITION OF THE FLORIDA BUILDING CODE - | | | ENERGY CONSERVATION SECTION 505.2.1.3(3) SLEEPING UNIT | | | CONTROLS HAS SPECIFIC LIGHTING CONTROL REQUIREMENTS FOR | | | HOTEL GUEST SUITES WHICH HAVE TO BE COMPLIED WITH. SEE | | | CLOUDED AREAS ON PLANS. | | | 2. AS PER 2008 NEC 210.60, RECEPTACLE PLACEMENT IN | | | HOTEL ROOMS SHALL COMPLY WITH NEC SECTIONS 210.52(A) & | | | (D) | | | 3. PAGE E2.04, E2.05 CIRCUIT ?L? IS NOT IDENTIFIED. | | | THIS CIRCUIT APPEARS TO BE IN A KITCHEN AREA. THOUGH | | | NOT INDICATED, IF PERMANENT COOKING FACILITIES ARE | | | INSTALLED, OUTLET PLACEMENT SHALL BE AS PER NEC 210.52 | | | PAGE E3.09 | | | 1. ADDED NOTE: EVERY GENERAL PURPOSE OUTLET INSTALLED | | | WITHIN 6' OF A SINK SHALL BE GFI PROTECTED, AS PER NEC | | | 210.8(B)(5) | | | 2. REFERRAL TO AN OUTLET IN A PORTABLE POOL BAR IS | | | MADE. ELABORATE FURTHER ON THIS. IF THE POOL BAR IS | | | PORTABLE WHAT OUTLET ARE YOU REFERRING TO? | | | PAGE E4.01 | | | REFERENCE TO THE ARC-FLASH LABEL REQUIREMENTS OF NEC | | | 110.16 IS MADE. | | | 1. ACCORDING TO THE PANEL SCHEDULE FOR MDP "M1", THIS | | | GOES TO CKT 12 | | | 2. NOT USED | | | 3. MISSING OCPD FOR PANEL "1LB", FROM PANEL "1L" ON | | | RISER PAGE 501 PANEL "1L" | | | 4. THERE ARE INCONSISTENCIES WITH THE REFERENCES TO "G" | | | PANEL. AT TIMES IT IS REFERRED TO "2G" OTHERS TIMES | | | "GL" AND YET ANOTHER "GLN" ARE THESE ALL ONE AND THE | | | SAME? IF SO, CORRECT TO MATCH | | | 5. THIS PANEL IS LABELED "GL" IN THE PANEL SCHEDULE FOR | | | "BRH". | | | 6. THE MAINS FOR THESE TWO PANELS ARE INVERTED | | | ACCORDING TO THE PANEL SCHEDULE FOR "M2" ON PAGE E5.05. | | | 7. THIS DISCONNECT & TRANSFORMER ARE MISSING FROM THE | | | RISER DIAGRAM | | | 8. SAME AS NOTE 7, THIS DISCONNECT AND TRANSFORMER DO | | | NOT APPEAR ON THE PANEL SCHEDULE. | | | 9. THE PANEL SCHEDULE OF PANEL "12NLA" HAS CKTS FOR | | | THIS PANEL RATHER THAN FROM PANEL "12NL" AS INDICATED | | | HERE. CORRECT TO MATCH. | | | 10. THIS PANEL APPEARS TO BE LABELED "ILDE" ON THE | | | PANEL SCHEDULE PAGE E4.03 | | | PAGE E4.02 | | | ALL WIRE SHALL BE LISTED FOR THE APPLICATION | | | 1. AS INDICATED HEREIN THAT 120V FOR LIGHTING CONTROL | | | PROVIDED BY OTHER. UNLESS THIS WORK IS INITIATED & | | | COMPLETED BY THE ELECTRICAL CONTRACTOR OF RECORD, A | | | SEPARATE PERMIT SHALL BE REQUIRED FOR THE LOW VOLTAGE | | | CONTROL WORK. | | | PAGE E4.03 | | | 1. ON THE RISER DIAGRAM OF PAGE E4.01, THIS PANEL | | | APPEARS TO BE LABELED "1LDE" RATHER THAN "ILDE". | | | CORRECT TO MATCH. | | | PAGE E5.01 | | | 1. REFERENCE MADE ON PANEL ?L?, ?2L? OF GFCI | | | REQUIREMENTS OF NEC 422.52 | | | 2. MISSING OCPD FOR PANEL "1LB", PER RISER ON PG. E4.01 | | | PAGE E5.02 | | | 1. REFERENCE NOTE TO THE NEC 210.8 GFCI REQUIREMENT FOR | | | OUTLETS ON ROOFS. | | | 2. SOURCE REFERENCE FOR PANELS ?2LS? & ?2LSA? | | | 3. THERE ARE INCONSISTENCIES WITH THE REFERENCES TO "G" | | | PANEL. AT TIMES IT IS REFERRED TO "2G" OTHERS TIMES | | | "GL" AND YET ANOTHER "GLN" ARE THESE ALL ONE AND THE | | | SAME? IF SO, CORRECT TO MATCH | | | PAGE E5.04 | | | 1. ACCORDING TO THE RISER DIAGRAM OF PAGE E4.01 THE | | | SOURCE FOR PANEL "2CH" IS "M2". HERE IT INDICATES "M1" | | | CORRECT ACCORDINGLY. | | | 2. NEC 422.52 REQUIRES ELECTRIC DRINKING FOUNTAINS TO | | | BE ON A GFCI CKT. | | | 3. NEC 422.51 HAS SPECIFIC REQUIREMENTS FOR VENDING | | | MACHINE CKTS. | | | 4. THERE ARE NUMEROUS GFI REQUIREMENTS NOT ADDRESSED | | | WITH RESPECT TO THE POOL AS WELL AS THE ELECTRIC | | | DRINKING FOUNTAIN. | | | PAGE E5.05 | | | 1. CLARIFY IF THE INTENTION OF THIS IS MAIN 3, "M3" | | | WHICH IS NON-EXISTENT. CORRECT TO MATCH WITH MDP "M2" | | | PAGE E5.06 | | | 1. CLARIFY IF THE INTENTION OF THIS IS MAIN 3, "M3" | | | WHICH IS NON-EXISTENT. CORRECT TO MATCH WITH MDP "M2" | | | PAGE E5.07 | | | 1. THE RISER DIAGRAM OF PAGE E4.01 SHOWS PANEL "PSLD" | | | AS BEING FED FROM PANEL "12NL" NOT "12NLA" CORRECT TO | | | MATCH. | | | PAGE E5.08 | | | 1. INDICATE THAT THIS PANEL ("KEQL") IS FED THROUGH | | | TRANSFORMER "T75", TO MATCH RISER DIAGRAM | | | 2. INDICATE THAT THIS PANEL "("3EQL") IS FED THROUGH | | | THE DISCONNECT VIA TRANSFORMER "T45". | | | PAGE E5.09 | | | 1. PER NFPA REQUIREMENTS, THESE CKT/BKRS SHALL BE RED | | | AND MECHANICALLY PROTECTED AS REQUIRED. | | | PAGE FA0.00 | | | SEPARATE PERMIT & SHOP DRAWINGS REQUIRED FOR THE FIRE | | | ALARM | | | | | | THESE PLANS WERE REVIEWED BY MIKE ALBARRAN, ELECTRICAL | | | PLANS EXAMINER | | | YOU ARE WELCOME TO REVIEW STATUS OR COMMENTS AT THE | | | FOLLOWING LINK: | | | | | | HTTP://ONESTOPSHOP.WPBGOV.COM/EGOVPLUS/PERMIT/PERM_STAT | | | US.ASPX | | | | | | ENTER YOUR PERMIT NUMBER (SEE SUBJECT LINE OF THIS | | | EMAIL FOR YOUR PERMIT #), CLICK ON THE PERMIT NUMBER, | | | AND THEN GO TO "PLAN REVIEWS" TO SEE YOUR COMMENTS (TAB | | | ABOVE THE SECOND PERMIT INFORMATION). | | | AFTER ISSUANCE, PLEASE CHECK YOUR PLAN CAREFULLY FOR | | | COMPLIANCE WITH ANY REDLINES, NOTES, PROVISOS, OR OTHER | | | PERMIT CONDITIONS. | | | FOR FURTHER ASSISTANCE, PLEASE FEEL FREE TO CONTACT ME. | | | I CAN BE REACHED AT 561-805-6718 OR [email protected] | | | |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
2 |
Status |
P |
Date |
2014-08-13 |
|
|
Cont ID |
|
| Sent By |
Mgonzale |
Date |
2014-08-13 |
Time |
|
Rev Time |
1.00 |
| Received By |
mgonzale |
Date |
2014-08-13 |
Time |
|
Sent To |
E |
|
| Notes |
| 2014-08-13 10:18:45 | NO OBJECTION |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
F |
Date |
2014-06-27 |
|
|
Cont ID |
|
| Sent By |
Mgonzale |
Date |
2014-06-27 |
Time |
|
Rev Time |
1.00 |
| Received By |
mgonzale |
Date |
2014-06-27 |
Time |
|
Sent To |
I |
|
| Notes |
| 2014-06-27 12:58:44 | PLEASE ADDRESS PLANNING'S COMMENTS.THANK YOU! | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2014-08-20 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2014-08-20 |
Time |
11:50 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2014-07-30 |
Time |
17:01 |
Sent To |
|
|
| Notes |
| 2014-08-08 11:26:07 | 600 OKEECHOBEE BOULEVARD - HIGH RISE HOTEL | | | PERMIT #14050111 | | | REVIEW COMMENTS - FIRE DEPARTMENT | | | NOTE: ALL FIRE REVIEW COMMENTS REFERENCE NFPA 101 REFER | | | TO NFPA 101-THE LIFE SAFETY CODE (2009 EDITION WITH | | | FLORIDA AMENDMENTS). | | | | | | | | | NEW COMMENT - SHEETS A3.00 - A3.14: DRAWING SERIES WILL | | | NEED TO BE UPDATED TO INCORPORATE THE NEW FLOOR PLANS | | | REPRESENTED ON THE OTHER SHEETS. | | | | | | NEW COMMENT - SHEET A4.03: FIRE COMMAND #150 HAS BEEN | | | RECONFIGURED RESULTING IN A MINIMUM ROOM DIMENSION OF | | | LESS THAN 10'-0" (FBC 911.1.3). | | | | | | NEW COMMENT - SHEET A4.04: FITNESS (#104) FREE-WEIGHTS | | | STORAGE RACK IS OBSTRUCTING EXIT DOOR #104A. | | | | | | RESPONSE COMMENT: FIRE PIT (SKY TERRACE) HAS NOT BEEN | | | ACCEPTED OR REJECTED AT THIS TIME. PRODUCT DATA AND | | | SHOP DRAWINGS TO BE SUBMITTED BY CONTRACTOR. OPEN | | | FLAMES WILL NEED TO BE GUARDED AGAINST ACCIDENTAL OR | | | INTENTIONAL CONTACT BY OCCUPANTS. | | | ORIGINAL COMMENT - GENERAL: PROVIDE ADDITIONAL | | | INFORMATION ON THE PROPOSED GAS FIRED PIT LOCATED NEAR | | | THE OPEN SKY TERRACE/BAR. SHEET E1-05 REFERENCES A GAS | | | FIRED PIT CONTROLLER, BUT NO OTHER DESIGN INFORMATION | | | WAS FOUND. | | | | | | RESPONSE COMMENT: ONLY ONE EXIT SIGN PROVIDED. THIS ONE | | | FIXTURE WILL BE INSUFFICIENT TO CLEARLY AND OBVIOUSLY | | | DIRECT OCCUPANTS TO THE EXITS. | | | ORIGINAL COMMENT - SHEET E1-06: NO EXTERIOR EXIT SIGNS | | | DIRECTING POOL OCCUPANTS TO EGRESS THROUGH THE | | | CONNECTOR. | | | | | | NEW COMMENT - SHEET E3.04: PROVIDE EMERGENCY LIGHTING | | | IN UNDERGROUND POOL EQUIPMENT ROOM IF NOT ALREADY | | | PROVIDED. | | | | | | RESPONSE COMMENT: PORTIONS OF THE SYSTEM UPSTREAM OF | | | ANY PRVS WILL BE SUBJECT TO PRESSURES EXCEEDING 150 PSI | | | DUE TO THE FIRE PUMP CHURN PRESSURE (+140 PSI) PLUS AN | | | ADDITIONAL +70 PSI FROM THE CITY SUPPLY SIDE. | | | ORIGINAL COMMENT - SHEET FP0-01: FIRE SPRINKLER NOTE | | | #15 - PER NFPA 13 SECTION 24.2.1.2 PORTIONS OF THE | | | SYSTEM NORMALLY SUBJECTED TO SYSTEM WORKING PRESSURES | | | IN EXCESS OF 150 PSI SHALL BE TESTED AT A PRESSURE OF | | | 50 PSI IN EXCESS OF SYSTEM WORKING PRESSURE. | | | | | | MODIFIED COMMENT: SHEET FP1-04, PROVIDE AN ADDITIONAL | | | 2-1/2" FIRE DEPARTMENT HOSE VALVE IN HOTEL LOBBY #100 | | | CORRIDOR. | | | ORIGINAL COMMENT - FIRE PROTECTION LEVEL 1: DUE TO THE | | | SIZE OF THE FLOOR PLATE, PLEASE PROVIDE 2-1/2" FIRE | | | DEPARTMENT HOSE VALVES THROUGHOUT THE CORRIDORS. | | | | | | NEW COMMENT: SHEET FP1-04, VERIFY AND CONFIRM ANY | | | EXTERIOR ROOFS, CANOPIES AND PORTE-COCHERES COMPLY WITH | | | NFPA 13 SECTION 8.15.7. | | | | | | RESPONSE COMMENT: DRAWINGS HAVE NOT BEEN MODIFIED TO | | | ADDRESS THE ORIGINAL COMMENT. | | | ORIGINAL COMMENT - SHEET FP1-13: THE SPRINKLERS | | | PROTECTING THE SPACES ON THE ROOF LEVEL WILL NEED TO BE | | | SUPPLIED BY A SEPARATE SUPERVISED CONTROL VALVE AND | | | FLOW SWITCH SO FIREFIGHTERS CAN DISTINGUISH A FIRE ON | | | THE 12TH FLOOR FROM A FIRE ON THE ROOF LEVEL. | | | | | | WESLEY JOLIN | | | ASSISTANT FIRE MARSHAL | | | WEST PALM BEACH FIRE RESCUE | | | [email protected] | | | (561) 805-6730 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2014-06-11 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2014-06-11 |
Time |
16:26 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2014-05-06 |
Time |
17:19 |
Sent To |
|
|
| Notes |
| 2014-05-07 08:31:54 | 600 OKEECHOBEE BOULEVARD - HIGH RISE HOTEL | | | PERMIT #14050111 | | | REVIEW COMMENTS - FIRE DEPARTMENT | | | NOTE: ALL FIRE REVIEW COMMENTS REFERENCE NFPA 101 REFER | | | TO NFPA 101-THE LIFE SAFETY CODE (2009 EDITION WITH | | | FLORIDA AMENDMENTS). | | | | | | | | | SHEET A2.02: FITNESS (#104) IS USING AN OCCUPANT LOAD | | | FACTOR OF 100 SQUARE FEET PER PERSON. EXERCISE ROOMS | | | WITH EQUIPMENT OR WITHOUT EQUIPMENT SHALL USE AN | | | OCCUPANT LOAD FACTOR OF 15 SQUARE FEET PERSON OR 50 | | | SQUARE FEET PERSON RESPECTIVELY PER TABLE 7.3.1.2. | | | PROVIDE AN EQUIPMENT LAYOUT. | | | | | | SHEET A2.02: A DELUGE SPRINKLER SYSTEM IS INDICATED TO | | | PROTECT THE CONNECTOR AND ACHIEVE AN EQUIVALENT 2-HOUR | | | FIRE RATED ENCLOSURE. TO MY KNOWLEDGE, THERE IS NOT A | | | LISTED DELUGE SYSTEM CAPABLE OF ACHIEVING THIS FIRE | | | RESISTANCE RATING. A MORE APPROPRIATE DESIGN MAY | | | INCLUDE THE USE OF THE TYCO WIINDOW SPRINKLERS. IF THE | | | DESIGN INTENT IS TO USE TYCO WINDOW SPRINKLERS TO | | | ACHIEVE UP TO A TWO-HOUR FIRE RATED SEPARATION, THE | | | SPRINKLERS MUST BE INSTALLED ACCORDING TO THE UL | | | LISTING DATA AND SHALL WET THE ENTIRE GLAZING SURFACE. | | | SPRINKLERS CANNOT BE USED TO PROTECT OPERABLE DOORS OR | | | WINDOWS. THE WINDOW SPRINKLERS DO NOT ALLOW HORIZONTAL | | | WINDOW MULLIONS AND REQUIRE THE GLASS CURTAIN WALL TO | | | BE ATTACHED TO A THREE FOOT HIGH PONY WALL TO KEEP | | | COMBUSTIBLE MATERIALS AT LEAST TWO INCHES AWAY FROM THE | | | GLAZING. PAY SPECIAL ATTENTION TO THE GLAZING ASSEMBLY | | | AS THE SPRINKLER POSITIONING VARIES FOR BUTT-GLAZED | | | INSTALLATIONS COMPARED TO VERTICAL MULLION | | | INSTALLATIONS. VERTICAL MULLIONS SHALL BE OF A DEPTH | | | THAT PREVENTS COLD SOLDERING OF ADJACENT SPRINKLERS. | | | THE SPRINKLER DESIGN SHOULD INDICATE WHICH WINDOW | | | SPRINKLER MODEL WILL BE USED (HORIZONTAL SIDEWALL OR | | | PENDENT VERTICAL SIDEWALL). | | | | | | SHEET A2.03: THE TWO STORY OPENING (PRE-FUNCTION #221) | | | SHALL COMPLY WITH THE REQUIREMENTS OF SECTION 8.6 FOR | | | VERTICAL OPENINGS AS EITHER A "COMMUNICATING SPACE", | | | "ATRIUM" OR " CONVENIENCE OPENING." FOR EXAMPLE, A | | | COMMUNICATING SPACE REQUIRES THE ENTIRE FLOOR AREA TO | | | BE OPEN AND UNOBSTRUCTED SUCH THAT A FIRE IN ANY PART | | | OF THE SPACE WILL BE READILY OBVIOUS TO THE OCCUPANTS | | | OF THE SPACE PRIOR TO THE TIME A FIRE BECOMES A HAZARD. | | | ANOTHER EXAMPLE, A CONVENIENCE OPENING REQUIRES THAT | | | THE FLOOR OPENING BE SEPARATED FROM EXIT ACCESS | | | CORRIDORS. | | | | | | SHEET A2.03: THE PLAN SHOWS THE 1-HOUR FIRE RATING | | | CROSSING THE CORRIDOR AT DOOR #221A; HOWEVER, THERE IS | | | NO 1-HOUR FIRE RATING INDICATED FOR THE WALL CROSSING | | | THE CORRIDOR AT DOOR #221B. ALSO THE DOOR SCHEDULE | | | (SHEET A14.01) DOES NOT INDICATE A FIRE RATING FOR | | | EITHER SET OF DOORS. | | | | | | SHEET A3.0: PROVIDE DIRECT ACCESS INTO THE FIRE PUMP | | | ROOM (B003) FROM THE CORRIDOR WITHOUT HAVING TO TRAVEL | | | THROUGH THE DOMESTIC PUMP ROOM (B002) FIRST. | | | | | | SHEET A3.01: STAIR #2 TERMINATES INSIDE THE BUILDING | | | WHICH IS PERMITTED BY SECTION 28.2.7.2; HOWEVER, THE | | | TRAVEL DISTANCE FROM THE TERMINATION OF THE EXIT | | | ENCLOSURE TO AN EXTERIOR EXIT DOOR LEADING TO A PUBLIC | | | WAY SHALL NOT EXCEED 100 FEET. | | | | | | SHEET A4.01: CONNECTOR DOORS (#156-#156F & 118A) | | | INDICATE THE USE OF TEMPERED GLASS. DOOR GLAZING WILL | | | NEED TO BE FIRE RATED AS SPRINKLERS ARE NOT LISTED TO | | | PROTECT OPERABLE DOOR/WINDOW GLAZING AND PROVIDE AN | | | EQUIVALENT FIRE RATING. | | | | | | SHEET A4.01: THE LIFE SAFETY PLAN (SHEET A2.02) | | | INDICATES A TWO-HOUR WALL RATING AROUND STAIR #6; | | | HOWEVER, THE DOOR SCHEDULE (SHEET A14.00) DOES NOT | | | INDICATE A DOOR FIRE RATING OR CLOSER. | | | | | | SHEET A4.01: THE LIFE SAFETY PLAN (SHEET A2.02) | | | INDICATES A ONE-HOUR WALL RATING AROUND POOL STORAGE | | | #126; HOWEVER, THE DOOR SCHEDULE (SHEET A14.00) DOES | | | NOT INDICATE A DOOR FIRE RATING OR CLOSER. | | | | | | SHEET A4.01: THE LIFE SAFETY PLAN (SHEET A2.02) | | | INDICATES A ONE-HOUR WALL RATING AROUND PARTITION | | | STORAGE #121N; HOWEVER, THE DOOR SCHEDULE (SHEET | | | A14.00) DOES NOT INDICATE A DOOR FIRE RATING OR CLOSER | | | FOR DOORS #121N AND #121O. | | | | | | SHEET A4.01: THE LIFE SAFETY PLAN (SHEET A2.02) | | | INDICATES A ONE-HOUR WALL RATING AROUND PARTITION | | | STORAGE #121L; HOWEVER, THE DOOR SCHEDULE (SHEET | | | A14.00) DOES NOT INDICATE A DOOR FIRE RATING OR CLOSER | | | FOR DOORS #121L. | | | | | | SHEET A4.04: DOOR #103C IN CORRIDOR #103C IS MISSING | | | PANIC HARDWARE IN DOOR SCHEDULE (SHEET A14.00). | | | | | | SHEET A4.04: DOOR #104 IN FITNESS #104 IS MISSING PANIC | | | HARDWARE IN THE DOOR SCHEDULE (SHEET A14.00). OCCUPANT | | | LOAD WILL EXCEED 100 PERSONS IN THE FITNESS ROOM ONCE | | | THE APPROPRIATE OCCUPANT LOAD FACTOR IS APPLIED. | | | EXITING STAIR #2 AND THEN TRAVELING THROUGH THE HOTEL | | | LOBBY EXCEEDS 100 FEET. ADDITIONALLY THIS PATH OF | | | TRAVEL IS NOT OBVIOUS AND DIRECT. | | | | | | LEVEL 100: THE OVERALL LIFE SAFETY EXITING CONCEPT | | | NEEDS TO BE COORDINATED WITH THE ELECTRICAL DRAWINGS | | | REGARDING THE PLACEMENT OF EXIT SIGNAGE. FOR EXAMPLE, | | | SHEET E1-09 SHOWS EXIT SIGNS AT DOORS #100E AND #106B | | | LEADING TO THE BAR TERRACE. HOW ARE OCCUPANTS BEING | | | DIRECTED TO THE PUBLIC WAY ONCE THEY ENTER THE BAR | | | TERRACE AREA? DOOR #100E IS NOT EQUIPPED WITH PANIC | | | HARDWARE. ADDITIONALLY AN EXIT SIGN HAS BEEN PLACED AT | | | DOOR #105A LEADING BAR OCCUPANTS THROUGH THE KITCHEN | | | AREA TO REACH AN EXIT. | | | | | | SHEET A4.06 (STAIR #3/BOILER ROOM #229/ELECTRICAL | | | #224): PER SECTION 28.3.2.1 ALL ROOMS CONTAINING | | | HIGH-PRESSURE BOILERS, TRANSFORMERS OR OTHER SERVICE | | | EQUIPMENT SUBJECT TO POSSIBLE EXPLOSION SHALL NOT BE | | | LOCATED DIRECTLY ADJACENT TO EXITS. | | | | | | SHEET A4.07: LEVEL 200 HAS ASSEMBLY USE ROOMS WITH | | | OCCUPANT LOADS EXCEEDING 100 PERSONS. THE EXIT ACCESS | | | DOORS FROM THESE ROOMS ARE EQUIPPED WITH PANIC/FIRE | | | EXIT HARDWARE; HOWEVER, THE OTHER EXIT ACCESS DOORS ON | | | THE FLOOR ARE NOT EQUIPPED WITH PANIC/FIRE EXIT | | | HARDWARE SUCH AS DOOR T08, 219, 219A, 221A, 221B, & | | | 223. PER SECTION 6.1.14.1.2, WHERE EXIT ACCESS FROM AN | | | OCCUPANCY TRAVERSES ANOTHER OCCUPANCY, THE MULTIPLE | | | OCCUPANCY SHALL BE TREATED AS A MIXED OCCUPANCY AND THE | | | MOST STRINGENT FIRE AND LIFE SAFETY REQUIREMENTS OF | | | EACH OCCUPANCY SHALL APPLY TO THE BUILDING. | | | | | | SHEET A4.07: THE SERVICE ELEVATOR LOBBY (ALL FLOORS) | | | INDICATES AN EXIT ACCESS DOOR (#219) WITH A CARD | | | READER. A CARD READER ON THE EGRESS SIDE IS NOT | | | PERMITTED AS THIS REQUIRES SPECIAL KNOWLEDGE AND A TOOL | | | TO GAIN ACCESS TO AN EXIT. | | | | | | SHEET A4.07 - DOOR T12 (SUITES #204 & #205): PER | | | SECTION 28.3.7.2, IN BUILDINGS PROTECTED THROUGHOUT BY | | | AN APPROVED, SUPERVISED AUTOMATIC SPRINKLER SYSTEM, | | | EACH HOTEL GUEST ROOM, INCLUDING GUEST SUITES SHALL BE | | | SEPARATED FROM OTHER GUEST ROOMS BY WALLS AND FLOORS | | | CONSTRUCTED AS FIRE BARRIERS HAVING A MINIMUM 1/2-HOUR | | | FIRE RESISTANCE RATING. DOORS IN THE FIRE BARRIERS | | | SHALL HAVE A FIRE RESISTANCE RATING OF NOT LESS THAN | | | 20-MINUTES AND SHALL NOT BE REQUIRED TO BE | | | SELF-CLOSING. | | | | | | SHEET A4.08: PER SECTION 28.3.7.2, IN BUILDINGS | | | PROTECTED THROUGHOUT BY AN APPROVED, SUPERVISED | | | AUTOMATIC SPRINKLER SYSTEM, EACH HOTEL GUEST ROOM, | | | INCLUDING GUEST SUITES SHALL BE SEPARATED FROM OTHER | | | GUEST ROOMS BY WALLS AND FLOORS CONSTRUCTED AS FIRE | | | BARRIERS HAVING A MINIMUM 1/2-HOUR FIRE RESISTANCE | | | RATING. DOORS IN THE FIRE BARRIERS SHALL HAVE A FIRE | | | RESISTANCE RATING OF NOT LESS THAN 20-MINUTES AND SHALL | | | NOT BE REQUIRED TO BE SELF-CLOSING. APPLIES TO SEVERAL | | | SUITES INCLUDING SUITES, #235, #240, #247 ETC. CHECK | | | OTHER FLOORS AS WELL. ALSO NO DOOR TAGS PROVIDED FOR | | | DOORS COMMUNICATING BETWEEN TWO ROOMS SUCH AS SUITE | | | #240 AND SUITE #247. | | | | | | SHEET A4.19: EXECUTIVE LOUNGE #1136 APPEARS TO BE AN | | | ASSEMBLY USE ROOM; HOWEVER, NO PANIC HARDWARE IS SHOWN | | | ON DOORS #1136 OR #1136D. | | | | | | GENERAL: PROVIDE ADDITIONAL INFORMATION ON THE PROPOSED | | | GAS FIRED PIT LOCATED NEAR THE OPEN SKY TERRACE/BAR. | | | SHEET E1-05 REFERENCES A GAS FIRED PIT CONTROLLER, BUT | | | NO OTHER DESIGN INFORMATION WAS FOUND. | | | | | | SHEET M1-00: COULD NOT OPEN DRAWING. FILE CONSISTENTLY | | | CRASHES COMPUTER. | | | | | | SHEET M1-04: KITCHEN #105 EXHAUST LOUVER FROM EXHAUST | | | FAN #3 (WALL TERMINATION) APPEARS TO BE WITHIN 10 FEET | | | OF OPERABLE DOORS #100F, #104A AND #105C (REFERENCE | | | SHEET A4.04). PER NFPA 96, SECTION 7.8.3 WALL | | | TERMINATIONS. WALL TERMINATIONS SHALL BE ARRANGED WITH | | | OR PROVIDED WITH THE FOLLOWING PROPERTIES: (1) THROUGH | | | A NONCOMBUSTIBLE WALL WITH A MINIMUM OF 10 FEET OF | | | CLEARANCE FROM THE OUTLET TO ADJACENT BUILDINGS, | | | PROPERTY LINES, GRADE LEVEL, COMBUSTIBLE CONSTRUCTION, | | | ELECTRICAL EQUIPMENT OR LINES, AND THE CLOSEST POINT OF | | | ANY AIR INTAKE OR OPERABLE DOOR OR WINDOW AT OR BELOW | | | THE PLANE OF THE EXHAUST TERMINATION. | | | | | | SHEET M1-04: VERIFY THERE ARE NO OPERABLE WINDOWS ABOVE | | | KIITCHEN #105 EXHAUST LOUVER FROM FAN #3 (WALL | | | TERMINATION). PER NFPA 96 SECTION 7.8.3, THE CLOSEST | | | POINT OF ANY AIR INTAKE OR OPERABLE DOOR OR WINDOW | | | ABOVE THE PLANE OF THE EXHAUST TERMINATION SHALL BE A | | | MINIMUM OF 10 FEET IN DISTANCE, PLUS 3-INCHES FOR EACH | | | 1 DEGREE FROM HORIZONTAL, THE ANGLE OF DEGREE BEING | | | MEASURED FROM THE CENTER OF THE EXHAUST TERMINATION TO | | | THE CENTER OF THE AIR INTAKE OR OPERABLE DOOR OR | | | WINDOW, AS INDICATED IN FIGURE 7.8.3. | | | | | | SHEET E1-06: SOUTH DIRECTION INDICATING CHEVRONS ARE | | | NEEDED AT THE EXIT SIGN PLACED AT THE CONNECTOR (HOTEL | | | TO CONVENTION CENTER). OCCUPANTS WILL NOT BE ABLE TO | | | EXIT THROUGH THE CONNECTOR (FROM HOTEL) IF THE FIRE | | | SHUTTER ACTIVATES. | | | | | | SHEET E1-06: NO EXTERIOR EXIT SIGNS DIRECTING POOL | | | OCCUPANTS TO EGRESS THROUGH THE CONNECTOR. | | | | | | SHEET E1-08: ONLY ONE EXIT SIGN PROVIDED IN MAIN | | | KITCHEN. ALSO, EXIT SIGNS LOCATED CORRIDOR | | | INTERSECTIONS SUCH AS SERVICE CORRIDOR #127 MAY NEED TO | | | HAVE TWO EXIT SIGNS IN LIEU OF ONLY ONE SIGN. THE | | | CURRENT SIGN PLACEMENT WILL ALLOW OCCUPANTS TRAVELING | | | NORTH/SOUTH TO VIEW THE SIGN; HOWEVER, OCCUPANTS | | | TRAVELING EAST/WEST WILL NOT BE ABLE TO VIEW THE SIGN. | | | | | | SHEET E1-09: EXIT SIGN IS ROUTING OCCUPANTS THROUGH THE | | | KITCHEN AREA. | | | | | | SHEET E1-09: NO EXIT SIGNS PROVIDED IN MEETING ROOM | | | #101. | | | | | | SHEET E1-09: EXIT SIGN NOT VIEWABLE FROM LONG PORTION | | | OF CORRIDOR #103A. | | | | | | SHEET E1-16 & E1-17: NO EXIT SIGNS PROVIDED IN ASSEMBLY | | | ROOMS. EXIT SIGNS IN THE CORRIDOR ADJACENT TO THE | | | ASSEMBLY ROOMS ONLY DIRECT OCCUPANTS TO USE THE CENTER | | | EXIT STAIR. ADDITIONAL EXIT SIGNAGE IS NEEDED NOTIFYING | | | OCCUPANTS THEY CAN ALSO USE THE SOUTH OR WEST STAIRS AS | | | WELL. | | | | | | SHEET E1-17: EXIT SIGN ALSO NEEDED ON SOUTHEAST SIDE OF | | | CORRIDOR DOORS. | | | | | | SHEET E1-20: NO EXIT SIGNS IN EXECUTIVE LOUNGE #1136. | | | | | | SHEET E3.00: COULD NOT LOCATE FIREFIGHTERS' SMOKE | | | CONTROL PANEL (KEY NOTE 9) IN THE FIRE COMMAND ROOM. | | | | | | SHEET E4.01: CONFIRM SMOKE CONTROL SYSTEM IS CONNECTED | | | TO THE EMERGENCY GENERATOR AND THE LOAD IS ACCOUNTED | | | FOR. | | | | | | SHEET FA0.00: PER LOCAL AHJ POLICY, DUCT SMOKE | | | DETECTORS SHALL INITIATE AN ALARM CONDITION IN LIEU OF | | | A SUPERVISORY ALARM. | | | | | | SHEET FA1-01: NO NOTIFICATION APPLIANCES LOCATED IN | | | CORRIDOR JUST EAST OF JUNIOR BALLROOM #121. | | | | | | SHEET FA1-09: ADD FIRE ALARM DEVICE (POSSIBLY TACTILE | | | WARNING DEVICES) SHOWN IN GUESTROOM #305 TO THE FIRE | | | ALARM LEGEND (B SYMBOLS). | | | | | | FIRE ALARM: INDICATE ALL GUESTROOMS THAT WILL BE ADA | | | COMPLIANT. APPEARS ONLY ROOM #305 HAS BEEN SETUP FOR | | | ADA REQUIREMENTS ON ALL FLOORS. | | | | | | SHEET FA1-12: PLAN NOTE INDICATES TO PROVIDE A FIRE | | | ALARM INTERFACE WITH BI-DIRECTIONAL ANTENNA SYSTEM. ARE | | | BOTH WIRED FIREFIGHTER PHONE JACKS AND BI-DIRECTIONAL | | | AMPLIFIER BEING PROVIDED? IF BOTH ARE NOT INTENDED, | | | PROVIDE BI-DIRECTIONAL RADIO AMPLIFIER SYSTEM IN LIEU | | | OF WIRED COMMUNICATION SYSTEM (FIREFIGHTER PHONE/JACKS) | | | PER FBC SECTION 907.2.13.2. | | | | | | SHEET FA1-13: CONFIRM SMOKE DETECTORS LOCATED AT THE | | | TOP OF THE ELEVATOR SHAFTS ARE TO BE INSTALLED TO | | | ACTIVATE THE ELEVATOR HOISTWAY SMOKE RELIEF EQUIPMENT; | | | OTHERWISE, NFPA 72 SECTION 21.3.6 PROHIBITS SMOKE | | | DETECTORS FROM BEING INSTALLED IN THESE LOCATIONS. | | | | | | SHEET FP0-01: FIRE SPRINKLER NOTE #15 - PER NFPA 13 | | | SECTION 24.2.1.2 PORTIONS OF THE SYSTEM NORMALLY | | | SUBJECTED TO SYSTEM WORKING PRESSURES IN EXCESS OF 150 | | | PSI SHALL BE TESTEDAT A PRESSURE OF 50 PSI IN EXCESS OF | | | SYSTEM WORKING PRESSURE. | | | | | | FIRE PROTECTION LEVEL 1: DUE TO THE SIZE OF THE FLOOR | | | PLATE, PLEASE PROVIDE 2-1/2" FIRE DEPARTMENT HOSE | | | VALVES THROUGHOUT THE CORRIDORS. | | | | | | SHEET FP1-08: COULD NOT LOCATE SPRINKLER PROTECTION FOR | | | LARGE OPEN AREA (COMMUNICATING SPACE). SPRINKLERS | | | PROTECTING HIGH CEILING OF COMMUNICATING SPACE WILL | | | NEED TO BE SUPPLIED AND ZONED FROM THE FIRST FLOOR | | | SYSTEM. | | | | | | SHEET FP1-13: THE SPRINKLERS PROTECTING THE SPACES ON | | | THE ROOF LEVEL WILL NEED TO BE SUPPLIED BY A SEPARATE | | | SUPERVISED CONTROL VALVE AND FLOW SWITCH SO | | | FIREFIGHTERS CAN DISTINGUISH A FIRE ON THE 12TH FLOOR | | | FROM A FIRE ON THE ROOF LEVEL. | | | | | | FIRE PROTECTION: COULD NOT LOCATE ANY HYDRANT FLOW TEST | | | DATA. | | | | | | WESLEY JOLIN | | | ASSISTANT FIRE MARSHAL | | | WEST PALM BEACH FIRE RESCUE | | | [email protected] | | | (561) 805-6730 | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
3 |
Status |
P |
Date |
2014-08-19 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2014-08-19 |
Time |
15:12 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-08-19 |
Time |
15:12 |
Sent To |
|
|
| Notes |
| 2014-08-19 15:12:03 | FUEL GAS PLAN REVIEW | | | PERMIT:14050111 | | | ADD: 600 OKEECHOBEE BLVD | | | CONT: COASTAL CONSTRUCTION | | | TEL: (561) 630-3770 | | | | | | 2010 FLORIDA BUILDING CODE W | | | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | | | THE PALM BEACH CONVENTION CENTER HILTON HOTEL | | | CONSTRUCTION OF NEW 400 ROOM HOTEL INCLUDING BALLROOMS, | | | RESTAURANT(S), MEETING SPACE, POOL DECK AND AMENITIES | | | | | | 3RD REVIEW | | | DATE: TUES. AUGUST 19/2014 | | | | | | ACTION: FUEL GAS PROVISO | | | | | | NOTE: FUEL GAS PERMITS ARE A SEPARATE PERMIT AND FEES, | | | THE REVIEW WILL BE COMPLETED UNDER THE MASTER SET OF | | | PLANS NO OTHER PLANS REQUIRED. | | | | | | 1) SHEET P3.02 THERE ARE (3) AREAS OF CONCERN, THE PIPE | | | SIZING IS CORRECT, THERE SEEMS TO BE A DISCREPANCY IN | | | THE BTU LOADS: | | | | | | 1A) PLEASE VIEW KEY NOTES 6 & 7, LAUNDRY & KITCHEN | | | BOILERS INDICATES A TOTAL OF (5) BOILERS WHERE AS | | | DEPICTED ONLY THE KITCHEN BOILERS ARE SHOWN. NO BOILERS | | | # 6 ARE SHOWN ON THE PLAN. THE TOTAL LOAD FOR THESE | | | BOILERS IS SHOWN AS 1,195,000 BTU LOAD, TYPO SHOULD BE | | | 1,995,000. PLEASE NOTE THE COMBINED LOADS OF THE | | | KITCHEN/ LAUNDRY BOILERS AND THE POOL(NOTE 8) AND SPA | | | (NOTE 9) IS CORRECT AT 3,995,000 BTU. 2010 FUEL GAS | | | CODE SECTIONS BTU LOAD OF EACH APPLIANCE AND THE TOTAL | | | BTU LOAD ON THE SYSTEM. REFER TO THE FBC-2010 FUEL GAS | | | SECS. 401.8 THRU 402.6.1 AND TABLES 402.4(1) THRU | | | 402.4(35) | | | | | | 1B) PLEASE VIEW KEY NOTES 6 & 7, LAUNDRY & KITCHEN | | | BOILERS INDICATES A TOTAL OF (5) BOILERS WHERE AS | | | DEPICTED ONLY THE KITCHEN BOILERS ARE SHOWN. NO BOILERS | | | # 6 ARE SHOWN ON THE PLAN. THE OTAL LOAD FOR THESE | | | BOILERS IS SHOWN AS 1,195,000 BTU LOAD, TYPO SHOULD BE | | | 1,995,000. PLEASE NOTE THE COMBINED LOADS OF THE | | | KITCHEN/ LAUNDRY BOILERS AND THE POOL(NOTE 8) AND SPA | | | (NOTE 9) IS CORRECT AT 3,995,000 BTU. 2010 FUEL GAS | | | CODE SECTIONS BTU LOAD OF EACH APPLIANCE AND THE TOTAL | | | BTU LOAD ON THE SYSTEM. REFER TO THE FBC-2010 FUEL GAS | | | SECS. 401.8 THRU 402.6.1 AND TABLES 402.4(1) THRU | | | 402.4(35) | | | | | | 1C) THE (3RD) AREA OF INTEREST IS THE RESTAURANT | | | KITCHEN, IN TOTALING UP ALL THE TOTAL BTU LOADS FOR THE | | | KITCHEN I COME UP WITH 922,000 BTU'S PLEASE RECHECK THE | | | TOTAL LOADS, 107.2.1.3 ADDITIONAL INFORMATION, | | | DISCREPANCY IN PLANS IN THIS AREA. NOTE THIS WILL | | | INCREASE THE TOTAL BTU LOAD FOR THE SYSTEM, BUT NOT | | | AFFECT THE PIPE SIZING. | | | | | | 2) 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE, CHAPTER 1, ADMINISTRATION 107.3.4.2 | | | DEFERRED SUBMITTALS. | | | THIS ITEM CAN BE A DEFERRED SUBMITTAL BUT WILL BE | | | REQUIRED TO VARIFY NOT OVER LOADING THE CAPACITY OF THE | | | FUEL GAS SYSTEM AND FOR SIZING. SUBMIT MANUFACTURE | | | SHEETS FOR ALL GAS EQUIPMENT TO VERIFY COMPLIANCE WITH | | | STANDARDS NFPA 54, NFPA 58, AND FBC-2010 FUEL GAS SEC. | | | 402.2 | | | | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
F |
Date |
2014-08-05 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2014-08-05 |
Time |
14:36 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-08-05 |
Time |
14:01 |
Sent To |
|
|
| Notes |
| 2014-08-05 14:36:24 | FUEL GAS PLAN REVIEW | | | PERMIT:14050111 | | | ADD: 600 OKEECHOBEE BLVD | | | CONT: COASTAL CONSTRUCTION | | | TEL: (561) 630-3770 | | | | | | 2010 FLORIDA BUILDING CODE W | | | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | | | THE PALM BEACH CONVENTION CENTER HILTON HOTEL | | | CONSTRUCTION OF NEW 400 ROOM HOTEL INCLUDING BALLROOMS, | | | RESTAURANT(S), MEETING SPACE, POOL DECK AND AMENITIES | | | | | | 2ND REVIEW | | | DATE: TUES. AUGUST 05/2014 | | | ACTION: DENIED | | | | | | NOTE: FUEL GAS PERMITS ARE A SEPARATE PERMIT AND FEES, | | | THE REVIEW WILL BE COMPLETED UNDER THE MASTER SET OF | | | PLANS NO OTHER PLANS REQUIRED. | | | | | | 1) SHEET P3.02 THERE ARE (3) AREAS OF CONCERN, THE PIPE | | | SIZING IS CORRECT, THERE SEEMS TO BE A DISCREPANCY IN | | | THE BTU LOADS: | | | | | | 1A) PLEASE VIEW KEY NOTES 6 & 7, LAUNDRY & KITCHEN | | | BOILERS INDICATES A TOTAL OF (5) BOILERS WHERE AS | | | DEPICTED ONLY THE KITCHEN BOILERS ARE SHOWN. NO BOILERS | | | # 6 ARE SHOWN ON THE PLAN. THE TOTAL LOAD FOR THESE | | | BOILERS IS SHOWN AS 1,195,000 BTU LOAD, TYPO SHOULD BE | | | 1,995,000. PLEASE NOTE THE COMBINED LOADS OF THE | | | KITCHEN/ LAUNDRY BOILERS AND THE POOL(NOTE 8) AND SPA | | | (NOTE 9) IS CORRECT AT 3,995,000 BTU. 2010 FUEL GAS | | | CODE SECTIONS BTU LOAD OF EACH APPLIANCE AND THE TOTAL | | | BTU LOAD ON THE SYSTEM. REFER TO THE FBC-2010 FUEL GAS | | | SECS. 401.8 THRU 402.6.1 AND TABLES 402.4(1) THRU | | | 402.4(35) | | | | | | 1B) PLEASE VIEW KEY NOTES 6 & 7, LAUNDRY & KITCHEN | | | BOILERS INDICATES A TOTAL OF (5) BOILERS WHERE AS | | | DEPICTED ONLY THE KITCHEN BOILERS ARE SHOWN. NO BOILERS | | | # 6 ARE SHOWN ON THE PLAN. THE OTAL LOAD FOR THESE | | | BOILERS IS SHOWN AS 1,195,000 BTU LOAD, TYPO SHOULD BE | | | 1,995,000. PLEASE NOTE THE COMBINED LOADS OF THE | | | KITCHEN/ LAUNDRY BOILERS AND THE POOL(NOTE 8) AND SPA | | | (NOTE 9) IS CORRECT AT 3,995,000 BTU. 2010 FUEL GAS | | | CODE SECTIONS BTU LOAD OF EACH APPLIANCE AND THE TOTAL | | | BTU LOAD ON THE SYSTEM. REFER TO THE FBC-2010 FUEL GAS | | | SECS. 401.8 THRU 402.6.1 AND TABLES 402.4(1) THRU | | | 402.4(35) | | | | | | 1C) THE (3RD) AREA OF INTEREST IS THE RESTAURANT | | | KITCHEN, IN TOTALING UP ALL THE TOTAL BTU LOADS FOR THE | | | KITCHEN I COME UP WITH 922,000 BTU'S PLEASE RECHECK THE | | | TOTAL LOADS, 107.2.1.3 ADDITIONAL INFORMATION, | | | DISCREPANCY IN PLANS IN THIS AREA. NOTE THIS WILL | | | INCREASE THE TOTAL BTU LOAD FOR THE SYSTEM, BUT NOT | | | AFFECT THE PIPE SIZING. | | | | | | 2) 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE, CHAPTER 1, ADMINISTRATION 107.3.4.2 | | | DEFERRED SUBMITTALS. | | | THIS ITEM CAN BE A DEFERRED SUBMITTAL BUT WILL BE | | | REQUIRED TO VARIFY NOT OVER LOADING THE CAPACITY OF THE | | | FUEL GAS SYSTEM AND FOR SIZING. SUBMIT MANUFACTURE | | | SHEETS FOR ALL GAS EQUIPMENT TO VERIFY COMPLIANCE WITH | | | STANDARDS NFPA 54, NFPA 58, AND FBC-2010 FUEL GAS SEC. | | | 402.2 | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | | REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL | | | LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH | | | A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE | | | SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE | | | FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR | | | YOUR ANTICIPATED COOPERATION. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2014-06-20 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2014-06-20 |
Time |
06:27 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-06-20 |
Time |
05:31 |
Sent To |
|
|
| Notes |
| 2014-06-20 06:27:42 | FUEL GAS PLAN REVIEW | | | PERMIT:14050111 | | | ADD: 600 OKEECHOBEE BLVD | | | CONT: COASTAL CONSTRUCTION | | | TEL: (561) 630-3770 | | | | | | 2010 FLORIDA BUILDING CODE W | | | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | | | THE PALM BEACH CONVENTION CENTER HILTON HOTEL | | | CONSTRUCTION OF NEW 400 ROOM HOTEL INCLUDING BALLROOMS, | | | RESTAURANT(S), MEETING SPACE, POOL DECK AND AMENITIES | | | | | | 1ST REVIEW | | | DATE: FRIDAY JUNE 20/2014 | | | ACTION: DENIED | | | | | | NOTE: FUEL GAS PERMITS ARE A SEPARATE PERMIT AND FEES, | | | THE REVIEW WILL BE COMPLETED UNDER THE MASTER SET OF | | | PLANS NO OTHER PLANS REQUIRED. | | | | | | 1) SHEET P3.02 THERE ARE (3) AREAS OF CONCERN, THE PIPE | | | SIZING IS CORRECT, THERE SEEMS TO BE A DISCREPANCY IN | | | THE BTU LOADS: | | | | | | 1A) PLEASE VIEW KEY NOTES 6 & 7, LAUNDRY & KITCHEN | | | BOILERS INDICATES A TOTAL OF (5) BOILERS WHERE AS | | | DEPICTED ONLY THE KITCHEN BOILERS ARE SHOWN. NO BOILERS | | | # 6 ARE SHOWN ON THE PLAN. THE OTAL LOAD FOR THESE | | | BOILERS IS SHOWN AS 1,195,000 BTU LOAD, TYPO SHOULD BE | | | 1,995,000. PLEASE NOTE THE COMBINED LOADS OF THE | | | KITCHEN/ LAUNDRY BOILERS AND THE POOL(NOTE 8) AND SPA | | | (NOTE 9) IS CORRECT AT 3,995,000 BTU. 2010 FUEL GAS | | | CODE SECTIONS BTU LOAD OF EACH APPLIANCE AND THE TOTAL | | | BTU LOAD ON THE SYSTEM. REFER TO THE FBC-2010 FUEL GAS | | | SECS. 401.8 THRU 402.6.1 AND TABLES 402.4(1) THRU | | | 402.4(35) | | | | | | 1B) PLEASE VIEW KEY NOTES 6 & 7, LAUNDRY & KITCHEN | | | BOILERS INDICATES A TOTAL OF (5) BOILERS WHERE AS | | | DEPICTED ONLY THE KITCHEN BOILERS ARE SHOWN. NO BOILERS | | | # 6 ARE SHOWN ON THE PLAN. THE OTAL LOAD FOR THESE | | | BOILERS IS SHOWN AS 1,195,000 BTU LOAD, TYPO SHOULD BE | | | 1,995,000. PLEASE NOTE THE COMBINED LOADS OF THE | | | KITCHEN/ LAUNDRY BOILERS AND THE POOL(NOTE 8) AND SPA | | | (NOTE 9) IS CORRECT AT 3,995,000 BTU. 2010 FUEL GAS | | | CODE SECTIONS BTU LOAD OF EACH APPLIANCE AND THE TOTAL | | | BTU LOAD ON THE SYSTEM. REFER TO THE FBC-2010 FUEL GAS | | | SECS. 401.8 THRU 402.6.1 AND TABLES 402.4(1) THRU | | | 402.4(35) | | | | | | 1C) THE (3RD) AREA OF INTEREST IS THE RESTAURANT | | | KITCHEN, IN TOTALING UP ALL THE TOTAL BTU LOADS FOR THE | | | KITCHEN I COME UP WITH 922,000 BTU'S PLEASE RECHECK THE | | | TOTAL LOADS, 107.2.1.3 ADDITIONAL INFORMATION, | | | DISCREPANCY IN PLANS IN THIS AREA. NOTE THIS WILL | | | INCREASE THE TOTAL BTU LOAD FOR THE SYSTEM, BUT NOT | | | AFFECT THE PIPE SIZING. | | | | | | 2) 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE, CHAPTER 1, ADMINISTRATION 107.3.4.2 | | | DEFERRED SUBMITTALS. | | | THIS ITEM CAN BE A DEFERRED SUBMITTAL BUT WILL BE | | | REQUIRED TO VARIFY NOT OVER LOADING THE CAPACITY OF THE | | | FUEL GAS SYSTEM AND FOR SIZING. SUBMIT MANUFACTURE | | | SHEETS FOR ALL GAS EQUIPMENT TO VERIFY COMPLIANCE WITH | | | STANDARDS NFPA 54, NFPA 58, AND FBC-2010 FUEL GAS SEC. | | | 402.2 | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | | REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL | | | LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH | | | A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE | | | SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE | | | FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR | | | YOUR ANTICIPATED COOPERATION. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2014-08-20 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2014-08-20 |
Time |
16:56 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2014-07-15 |
Time |
08:08 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2014-06-27 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2014-06-27 |
Time |
13:39 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2014-05-06 |
Time |
09:15 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
N |
Date |
2014-06-21 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2014-06-21 |
Time |
15:00 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-06-21 |
Time |
15:00 |
Sent To |
|
|
| Notes |
| 2014-06-21 15:01:39 | PAID ON THE FOUNDATION PERMIT . |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2015-04-30 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2015-04-30 |
Time |
14:07 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2015-04-30 |
Time |
14:03 |
Sent To |
|
|
| Notes |
| 2015-04-30 14:07:22 | SHOP DRAWINGS OK FOR FLOOR 3 - 8 HM. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2014-08-15 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2014-08-15 |
Time |
13:51 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2014-08-13 |
Time |
14:57 |
Sent To |
|
|
| Notes |
| 2014-08-15 13:51:37 | PASS PROVISO | | | 1) PROVIDE SEPARATE APPLICATION, PLANS, AND PERMIT FOR | | | KITCHEN HOOD AND COOLERS. | | | 2) PROVIDE DRYER MANUFACTURERS INSTALLATION | | | INSTRUCTIONS | | | AT ROUGH INSPECTION. | | | 3) PROVIDE A DETAIL ON ROOF TOP EQUIPMENT PER SECTION | | | 301.12 WIND RESISTANCE | | | | | | PLAN REVIEW BY HAROLD MOSER | | | [email protected] | | | OFFICE 561-805-6732 | | | FAX 561-805-6676 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2014-06-27 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2014-06-27 |
Time |
09:31 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2014-06-25 |
Time |
14:54 |
Sent To |
|
|
| Notes |
| 2014-06-27 09:30:12 | PLAN DENIED | | | 1) REFER TO SECTION 506.3.12.2 TERMINATION THROUGH AN | | | EXTERIOR WALL. | | | 2010 FBC (M) (FOR HOOD EXHAUST) | | | 2) REFER TO SECTION 607 DUCT AND TRANSFER OPENING. WHAT | | | TYPE OF | | | PROTECTION OF DUCT PENETRATION ARE USED FOR MEETING | | | ROOMS AND SUITES | | | 2ED LEVEL AND UP 2010 FBC (M) | | | 3) PROVIDEE DRYER MANUFACTURERS INSTRUCTIONS WITH THE | | | PLANS PER | | | SECTION 504.7 COMMERCIAL CLOTHES DRYER. 2010 FBC (M) | | | REFER TO DRYER BOOSTER FAN DETAIL. | | | 4) PLEASE MOVE THE DIESEL FUEL PIPING ISOMETRIC TO THE | | | MECHANICAL PLAN | | | PER SECTION 1301 FBC (M) | | | 5) PROVIDE AN ISOMETRIC OF THE GENERATOR EXHAUST ON THE | | | MECHANICAL PLAN. | | | PER SECTION 510 FBC (M) | | | 6) PROVIDE STATIC PRESSURE OF AIR CONDITIONING SYSTEMS | | | ON THE PLAN. | | | PROVID A DETAIL ON THE TYPE OF DUCT REINFORCEMENT | | | REQUIRED ON THE PLAN. | | | CHAPTER 2 SMACNA | | | | | | PLAN REVIEW BY HAROLD MOSER | | | [email protected] | | | OFFICE 561-805-6732 | | | FAX 561-805-6676 | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2014-08-19 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2014-08-19 |
Time |
15:13 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-08-19 |
Time |
15:13 |
Sent To |
|
|
| Notes |
| 2014-08-19 15:17:31 | P B CONVENTION CENTER HILTON HOTEL PLUMBING REVIEW | | | PLUMBING PLAN REVIEW | | | PERMIT:14050111 | | | ADD: 600 OKEECHOBEE BLVD | | | CONT: COASTAL CONSTRUCTION | | | TEL: (561) 630-3770 | | | | | | 2010 FLORIDA BUILDING CODE W | | | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | | | THE PALM BEACH CONVENTION CENTER HILTON HOTEL | | | CONSTRUCTION OF NEW 400 ROOM HOTEL INCLUDING BALLROOMS, | | | RESTAURANT(S), MEETING SPACE, POOL DECK AND AMENITIES | | | | | | 3RD REVIEW | | | DATE: TUESDAY AUGUST 19/ 2014 | | | | | | ACTION: PLUMBING PROVISO | | | | | | FUEL GAS: THIS REVIEW IS UNDER A SEPARATE PLAN REVIEW | | | STOP, SEE FOR STATUS AND COMMENTS. | | | | | | 1) 2ND REQUEST: THE ASSOCIATES CAFETERIA PLUMBING PLAN | | | LIST EQUIPMENT AND PLUMBING FIXTURES WITH A C-LABEL. | | | THE PLUMBING INDEX LIST SHEET P2.01 AS THE BANQUET | | | KITCHEN & ASSO. CAFE SCHEDULE, THERE ARE NO C EQUIPMENT | | | ON SHEET P2.01, THIS LIST ALL FIXTURES & EQUIPMENT ON | | | THIS SHEET ARE LISTED WITH A Q. I CAN'T IDENTIFY THE | | | TYPE OF EQUIPMENT FOR THE TYPE OR WASTE REQUIRED. NOTE | | | # 10 REFERS TO GREASY WASTE FOR THIS SHEET BUT NOT | | | IDENTIFIED ON THE PLAN. | | | | | | 2) SHEET P1.02 LEVEL 1 AREA Q2, NOTE# 21 INDICATES A | | | NEW 750 GALLON CONCRETE VAULT TYPE GREASE INTERCEPTOR, | | | NOTE 36 SEE SHEET P3.01D FOR THE CONTINUATION OF GREASY | | | WASTE. PLEASE PROVIDE THE SIZING CALCULATIONS FOR THE | | | CONCRETE VAULT TYPE GREASE INTERCEPTOR, SIZING IS TO BE | | | IN ACCORDANCE WITH 2010 FBC-P SECTION 1003.5.1 AND | | | TABLE 1003.5.1. | | | | | | 3) SHEET P1.03 LEVEL 1 AREA Q3. SHEET P1.03 LEVEL 1 | | | AREA Q3, NOTE# 01 INDICATES A NEW 1,250 GALLON CONCRETE | | | VAULT TYPE GREASE INTERCEPTOR, NOTE REFERS TO SHEET | | | P4.03 THE GREASE INTERCEPTOR DETAIL. SHEET P3.00 | | | INDICATES 132 FU DRAINING INTO THE GREASE INTERCEPTOR. | | | IF SIZING USING TABLE 1003.3.4.1 THIS TABLE IS TO BE | | | USED WHEN THE DESIGN IS FOR HYDRO MECHANICAL GREASE | | | INTERCEPTORS. PLEASE PROVIDE THE SIZING CALCULATIONS | | | FOR THE CONCRETE VAULT TYPE GREASE INTERCEPTOR, SIZING | | | IS TO BE IN ACCORDANCE WITH 2010 FBC-P SECTION 1003.5.1 | | | AND TABLE 1003.5.1. | | | | | | THE CITY FOG INSPECTORS (FATS, OILS & GREASE) MONITOR | | | ALL GREASE INTERCEPTORS TO VERIFY COMPLIANCE WITH THE | | | CITY?S MUNI CODE SEC. 90-126. PROHIBITIONS AND | | | LIMITATIONS OF DISCHARGE.(7) MINERAL OIL IN EXCESS OF | | | 50 MG/L OR ANIMAL/VEGETABLE FATS, WAX, GREASE, OR OILS | | | IN EXCESS OF 100 MG/L, WHETHER EMULSIFIED OR NOT; OR | | | SUBSTANCES WHICH MAY SOLIDIFY OR BECOME VISCOUS AT | | | TEMPERATURES LOWER THAN OR EQUAL TO 150 DEGREES | | | FAHRENHEIT (65.56 DEGREES CELSIUS). | | | | | | 4) SHEET P1.04 LEVEL 1 AREA Q4. KITCHEN 105 , NO GREASY | | | WASTE IS SHOWN ON THE PLANS, NOTE # 15 INDICATES SEE | | | P2.04 FOR CONTINUATION. THIS SHEET IS A EQUIPMENT | | | SCHEDULE, PLEASE PROVIDE A GREASY WASTE ISOMETRIC OR | | | WHERE TO LOCATE SUCH PLANS. PLEASE PROVIDE THE SIZING | | | CALCULATIONS FOR THE CONCRETE VAULT TYPE GREASE | | | INTERCEPTOR, SIZING IS TO BE IN ACCORDANCE WITH 2010 | | | FBC-P SECTION 1003.5.1 AND TABLE 1003.5.1. | | | | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2014-08-05 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2014-08-05 |
Time |
15:42 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-08-01 |
Time |
07:05 |
Sent To |
|
|
| Notes |
| 2014-08-05 15:42:09 | P B CONVENTION CENTER HILTON HOTEL 1ST PLUMBING REVIEW | | | PLUMBING PLAN REVIEW | | | PERMIT:14050111 | | | ADD: 600 OKEECHOBEE BLVD | | | CONT: COASTAL CONSTRUCTION | | | TEL: (561) 630-3770 | | | | | | 2010 FLORIDA BUILDING CODE W | | | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | | | THE PALM BEACH CONVENTION CENTER HILTON HOTEL | | | CONSTRUCTION OF NEW 400 ROOM HOTEL INCLUDING BALLROOMS, | | | RESTAURANT(S), MEETING SPACE, POOL DECK AND AMENITIES | | | | | | 2ND REVIEW | | | DATE: TUESDAY AUGUST 05/ 2014 | | | | | | ACTION: DENIED | | | | | | FUEL GAS: THIS REVIEW IS UNDER A SEPARATE PLAN REVIEW | | | STOP, SEE FOR STATUS AND COMMENTS. | | | | | | 1-2) COMPLIED. | | | 3) SHEET P0.01 BASEMENT LEVEL: | | | | | | 3A) 2ND REQUEST: THE ASSOCIATES CAFETERIA PLUMBING PLAN | | | LIST EQUIPMENT AND PLUMBING FIXTURES WITH A C-LABEL. | | | THE PLUMBING INDEX LIST SHEET P2.01 AS THE BANQUET | | | KITCHEN & ASSO. CAFE SCHEDULE, THERE ARE NO C EQUIPMENT | | | ON SHEET P2.01, THIS LIST ALL FIXTURES & EQUIPMENT ON | | | THIS SHEET ARE LISTED WITH A Q. I CAN'T IDENTIFY THE | | | TYPE OF EQUIPMENT FOR THE TYPE OR WASTE REQUIRED. NOTE | | | # 10 REFERS TO GREASY WASTE FOR THIS SHEET BUT NOT | | | IDENTIFIED ON THE PLAN. | | | | | | 3B)(1)(2)(3)(4) COMPLIED. | | | | | | 3C) COMPLIED. | | | | | | 3D) COMPLIED. | | | | | | 3E) COMPLIED. | | | | | | 3F) FOUND, NO COMMENT. | | | | | | 3G) 2ND REQUEST, RESPONSE INDICATES SEE SHEET P4.02. | | | SHEET P0.01 THE BASEMENT LEVEL/ POOL EQUIPMENT ROOM | | | NOTE #10 INDICATES THE USE OF A SUMP PUMP TO PUMP THE | | | POOL BACK WASH TO SANITARY, THERE IS NO PIT SHOWN ON | | | THE PLANS, NOR IS THERE A NOTE PROVIDING DETAILS SIZE | | | OF PUMP OR DISCHARGE REQUIRED. SUMPS ARE TO COMPLY WITH | | | 2010 FBC-P 712. | | | | | | 3H) COMPLIED. | | | | | | 4 ) COMPLIED. | | | | | | 5) SHEET P1.02 LEVEL 1 AREA Q2: | | | | | | 5A) COMPLIED. | | | | | | 5B) 2ND REQUEST. SHEET P1.02 LEVEL 1 AREA Q2, NOTE# 21 | | | INDICATES A NEW 750 GALLON CONCRETE VAULT TYPE GREASE | | | INTERCEPTOR, NOTE 36 SEE SHEET P3.01D FOR THE | | | CONTINUATION OF GREASY WASTE. PLEASE PROVIDE THE SIZING | | | CALCULATIONS FOR THE CONCRETE VAULT TYPE GREASE | | | INTERCEPTOR, | | | SIZING IS TO BE IN ACCORDANCE WITH 2010 FBC-P SECTION | | | 1003.5.1 AND TABLE 1003.5.1. | | | | | | 5C) REVIEWED BY MECHANICAL PLAN REVIEW.NO ACTION | | | REQUIRED. SHEET P1.02 LEVEL 1 AREA Q2, NOTES 22-25 | | | DEALS WITH FUEL LINES, PLEASE NOTE DIRECTLY ABOVE THE | | | NEXT STORY IS THE DIESEL EMERGENCY GENERATOR. DIESEL, | | | FUEL TANKS AND ASSOCIATED LINES WILL BE REVIEWED BY THE | | | MECHANICAL REVIEWER AND INSPECTED BY THE MECHANICAL | | | INSPECTOR. DETAIL P4.04. | | | | | | 6) 2ND REQUEST. SHEET P1.03 LEVEL 1 AREA Q3. SHEET | | | P1.03 LEVEL 1 AREA Q3, NOTE# 01 INDICATES A NEW 1,250 | | | GALLON CONCRETE VAULT TYPE GREASE INTERCEPTOR, NOTE | | | REFERS TO SHEET P4.03 THE GREASE INTERCEPTOR DETAIL. | | | SHEET P3.00 INDICATES 132 FU DRAINING INTO THE GREASE | | | INTERCEPTOR. IF SIZING USING TABLE 1003.3.4.1 THIS | | | TABLE IS TO BE USED WHEN THE DESIGN IS FOR HYDRO | | | MECHANICAL GREASE INTERCEPTORS. | | | PLEASE PROVIDE THE SIZING CALCULATIONS FOR THE CONCRETE | | | VAULT TYPE GREASE INTERCEPTOR, SIZING IS TO BE IN | | | ACCORDANCE WITH 2010 FBC-P SECTION 1003.5.1 AND TABLE | | | 1003.5.1. | | | | | | THE CITY FOG INSPECTORS (FATS, OILS & GREASE) MONITOR | | | ALL GREASE INTERCEPTORS TO VERIFY COMPLIANCE WITH THE | | | CITY?S MUNI CODE SEC. 90-126. PROHIBITIONS AND | | | LIMITATIONS OF DISCHARGE.(7) MINERAL OIL IN EXCESS OF | | | 50 MG/L OR ANIMAL/VEGETABLE FATS, WAX, GREASE, OR OILS | | | IN EXCESS OF 100 MG/L, WHETHER EMULSIFIED OR NOT; OR | | | SUBSTANCES WHICH MAY SOLIDIFY OR BECOME VISCOUS AT | | | TEMPERATURES LOWER THAN OR EQUAL TO 150 DEGREES | | | FAHRENHEIT (65.56 DEGREES CELSIUS). | | | | | | 7) 2ND REQUEST, RESPONSE INDICATES SEE SHEET P2.01 FOR | | | THIS AREA. SHEET P1.04 LEVEL 1 AREA Q4. KITCHEN 105 , | | | NO GREASY WASTE IS SHOWN ON THE PLANS, NOTE # 15 | | | INDICATES SEE P2.04 FOR CONTINUATION. THIS SHEET IS A | | | EQUIPMENT SCHEDULE, PLEASE PROVIDE A GREASY WASTE | | | ISOMETRIC OR WHERE TO LOCATE SUCH PLANS. PLEASE PROVIDE | | | THE SIZING CALCULATIONS FOR THE CONCRETE VAULT TYPE | | | GREASE INTERCEPTOR, SIZING IS TO BE IN ACCORDANCE WITH | | | 2010 FBC-P SECTION 1003.5.1 AND TABLE 1003.5.1. | | | | | | 8) COMPLIED. | | | | | | 9) COMPLIED. | | | | | | 10) COMPLIED | | | | | | 11) COMPLIED. | | | | | | 12) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW | | | COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | | THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR | | | PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2014-06-21 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2014-06-21 |
Time |
14:59 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-06-04 |
Time |
10:14 |
Sent To |
|
|
| Notes |
| 2014-06-17 17:59:22 | P B CONVENTION CENTER HILTON HOTEL 1ST PLUMBING REVIEW | | | PLUMBING PLAN REVIEW | | | PERMIT:14050111 | | | ADD: 600 OKEECHOBEE BLVD | | | CONT: COASTAL CONSTRUCTION | | | TEL: (561) 630-3770 | | | | | | 2010 FLORIDA BUILDING CODE W | | | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | | | THE PALM BEACH CONVENTION CENTER HILTON HOTEL | | | CONSTRUCTION OF NEW 400 ROOM HOTEL INCLUDING BALLROOMS, | | | RESTAURANT(S), MEETING SPACE, POOL DECK AND AMENITIES | | | | | | 1ST REVIEW | | | DATE: TUESDAY JUNE 17TH/ 2014 | | | | | | ACTION: DENIED | | | | | | FUEL GAS: THIS REVIEW IS UNDER A SEPARATE PLAN REVIEW | | | STOP, SEE FOR STATUS AND COMMENTS. | | | | | | 1) THE PERMIT DESCRIPTION LISTED ABOVE TO BUILD THE | | | HOTEL, POOL, POOL DECK & AMENITIES IS A INCLUSIVE | | | PACKAGE WITHIN THE SUBMITTED PLANS. THERE ARE CIVIL, | | | SITE, LANDSCAPING, IRRIGATION, GREASE INTERCEPTORS, | | | FUEL GAS, GENERATOR, FIRE SPRINKLER, FIRE ALARM, | | | LOW-VOLTAGE, AWNINGS AND SIGNAGE PLANS WITHIN THE | | | SUBMITTED DOCUMENTS. | | | THESE TYPE OF ACTIVITIES REQUIRE A SEPARATE PERMIT | | | APPLICATION, REVIEW AND ASSOCIATED FEES. PLEASE BACK | | | OUT THE VALUE OF WORK TO BE COMPLETED UNDER EACH OF | | | THESE PERMITS SO THE BUILDING DEPARTMENT DOES NOT | | | CHARGE YOU TWICE FOR THESE SERVICES. 2010 WEST PALM | | | BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER | | | 1, ADMINISTRATION 105.1 PERMITS | | | | | | 2) SHEET A3.00 MINIMUM NUMBER OF REQUIRED PLUMBING | | | FIXTURES: | | | | | | 2A) HEADING: A-2 OCCUPANCY (BANQUET HALL) GRAND BALL | | | ROOM, JR. BALLROOM & MEETING ROOMS ARE FIGURED AT 1/75 | | | FOR WATER CLOSETS & 1/200 FOR LAVS. | | | THE USE OF THESE ROOMS WILL VARY DEPENDING ON THE | | | EVENT, EVEN THOUGH THE OCCUPANT LOAD WILL STAY THE SAME | | | THE MINIMUM NUMBER OF REQUIRED FIXTURES WILL CHANGE. IF | | | IT IS TO BE CONSIDERED A DANCE HALL THE MINIMUM NUMBER | | | OF REQUIRED FIXTURES (W.C.) WOULD BE CONSIDERED AT 1/40 | | | OR IF A EXHIBITION HALL THE WOMEN?S (W. C.) WOULD DROP | | | TO 1/65. THE VARIOUS BALLROOMS AND MEETING ROOMS MAY BE | | | RENTED OUT BY VARIOUS ORGANIZATIONS WITH DIFFERENT | | | EVENT TYPES THIS LOADING FACTOR NEEDS TO BE REFIGURED. | | | | | | 2B) HEADING: POOL AN A4 OCCUPANCY. WITHIN THE CHART THE | | | CELL FOR REQUIRED DRINKING FOUNTAIN & SERVICE SINK IS | | | STRUCK THROUGH. TABLE 403.1 UNDER THE ASSEMBLY HEADING | | | A4 POOLS UNDER THE REQUIRED MINIMUM FIXTURES LIST | | | DRINKING FOUNTAINS AND SERVICE SINKS. | | | | | | 2C) HEADING SPORTS BAR & TERRACE A-2 OCCUPANCY | | | INDICATES THE LAVS FIGURED AT 1/200, THAT IS FOR | | | RESTAURANTS, PLEASE SEE TABLE 403.2 LAVS ARE TO BE | | | FIGURED AT 1/40 FOR BARS AND SIMILAR PURPOSES. | | | | | | 2D) HEADING FOR THE FITNESS CENTER IS A BUSINESS | | | OCCUPANCY THIS WOULD BE ACCEPTABLE IF THERE IS TO BE A | | | INSTRUCTOR THERE ALL THE TIME FOR PERSONAL TRAINING AND | | | FITNESS OTHERWISE THIS HEADING SHOULD BE AN A3 | | | OCCUPANCY FOR A GYM THE OCCUPANT LOAD WOULD CHANGE. | | | | | | 3) SHEET P0.01 BASEMENT LEVEL: | | | 3A) THE ASSOCIATES CAFETERIA PLUMBING PLAN LIST | | | EQUIPMENT AND PLUMBING FIXTURES WITH A C-LABEL. THE | | | PLUMBING INDEX LIST SHEET P2.01 AS THE BANQUET KITCHEN | | | & ASSO. CAFE SCHEDULE, THERE ARE NO C EQUIPMENT ON THIS | | | LIST ALL FIXTURES & EQUIPMENT ON THIS SHEET ARE LISTED | | | WITH A Q. I CAN'T IDENTIFY THE TYPE OF EQUIPMENT FOR | | | THE TYPE OR WASTE REQUIRED. NOTE # 10 REFERS TO GREASY | | | WASTE FOR THIS SHEET BUT NOT IDENTIFIED ON THE PLAN. | | | | | | 3B)(1) SHEET P0.01 THE BASEMENT LEVEL WITHIN THE ACTIVE | | | LINEN STORAGE ROOM THERE IS A SUMP PIT, NOTE # 1 | | | INDICATES SEE DETAIL SHEET P4.01 FOR SANITARY LIFT | | | STATION. THE DETAIL SHOWS THE 2" DISCHARGE PIPE | | | VERTICALLY THEN MAKING A 90 DEGREE TURN BENEATH THE | | | SLAB, THERE INSTALLED A FLANGED CHECK VALVE FOR EACH | | | PUMP AND A FLANGED GATE VALVE (1) FOR EACH PUMP. PLEASE | | | SEE SECTION FBC-P 712.2 FOR REQUIRED COMPLIANCE. | | | 2010 FBC-PLUMBING 712.2 VALVES REQUIRED. | | | A CHECK VALVE AND A FULL OPEN VALVE LOCATED ON THE | | | DISCHARGE SIDE OF THE CHECK VALVE SHALL BE INSTALLED IN | | | THE PUMP OR EJECTOR DISCHARGE PIPING BETWEEN THE PUMP | | | OR EJECTOR AND THE GRAVITY DRAINAGE SYSTEM. ACCESS | | | SHALL BE PROVIDED TO SUCH VALVES. SUCH VALVES SHALL BE | | | LOCATED ABOVE THE SUMP COVER REQUIRED BY SECTION 712.1 | | | OR, WHERE THE DISCHARGE PIPE FROM THE EJECTOR IS BELOW | | | GRADE, THE VALVES SHALL BE ACCESSIBLY LOCATED OUTSIDE | | | THE SUMP BELOW GRADE IN AN ACCESS PIT WITH A REMOVABLE | | | ACCESS COVER. | | | | | | 3B)(2) SHEET P0.01 THE BASEMENT LEVEL WITHIN THE ACTIVE | | | LINEN STORAGE ROOM THERE IS A SUMP PIT, NOTE # 1 | | | INDICATES SEE DETAIL SHEET P4.01 FOR SANITARY LIFT | | | STATION. THE DETAIL OF THE LIFT STATION ALSO DOES NOT | | | PROVIDE ANY DETAILS ON THE ACCESS COVER, SIZE, | | | THICKNESS OF COVER, TYPE OF MATERIAL OR HOW ACCESS | | | COVER WILL BE ATTACHED TO THE FLOOR, OR HOW THE COVER | | | WILL BE ACCESSIBLE FOR MAINTENANCE. | | | 2010 FBC-P 712.3.2 SUMP PIT. | | | THE SUMP PIT SHALL BE NOT LESS THAN 18 INCHES (457 MM) | | | IN DIAMETER AND 24 INCHES (610 MM) DEEP, UNLESS | | | OTHERWISE APPROVED. THE PIT SHALL BE ACCESSIBLE AND | | | LOCATED SUCH THAT ALL DRAINAGE FLOWS INTO THE PIT BY | | | GRAVITY. THE SUMP PIT SHALL BE CONSTRUCTED OF TILE, | | | CONCRETE, STEEL, PLASTIC OR OTHER APPROVED MATERIALS. | | | THE PIT BOTTOM SHALL BE SOLID AND PROVIDE PERMANENT | | | SUPPORT FOR THE PUMP. THE SUMP PIT SHALL BE FITTED WITH | | | A GAS-TIGHT REMOVABLE COVER ADEQUATE TO SUPPORT | | | ANTICIPATED LOADS IN THE AREA OF USE. | | | | | | 3B)(3) SHEET P0.01 THE BASEMENT LEVEL WITHIN THE ACTIVE | | | LINEN STORAGE ROOM THERE IS A SUMP PIT, NOTE # 1 | | | INDICATES SEE DETAIL SHEET P4.01 FOR SANITARY LIFT | | | STATION. THE PLUMBING SHEET P0.01 NOR HAS THIS DETAIL | | | P4.01 PROVIDED THE TOTAL DRAINAGE FIXTURE UNITS/ | | | GALLONS PER MINUTE OF WASTE THAT IS TO DRAIN INTO THE | | | SANITARY LIFT STATION. PLEASE PROVIDE THIS DATA TO SEE | | | THAT THE SPECKED PUMPS WILL MEET THE DEMAND AND PROVIDE | | | COMPLIANCE WITH 2010 FBC-P 712.4.2 CAPACITY. | | | 712.4.2 CAPACITY. | | | A SEWAGE PUMP OR SEWAGE EJECTOR SHALL HAVE THE CAPACITY | | | AND HEAD FOR THE APPLICATION REQUIREMENTS. PUMPS OR | | | EJECTORS THAT RECEIVE THE DISCHARGE OF WATER CLOSETS | | | SHALL BE CAPABLE OF HANDLING SPHERICAL SOLIDS WITH A | | | DIAMETER OF UP TO AND INCLUDING 2 INCHES (51 MM). OTHER | | | PUMPS OR EJECTORS SHALL BE CAPABLE OF HANDLING | | | SPHERICAL SOLIDS WITH A DIAMETER OF UP TO AND INCLUDING | | | 1 INCH (25.4 MM). THE MINIMUM CAPACITY OF A PUMP OR | | | EJECTOR BASED ON THE DIAMETER OF THE DISCHARGE PIPE | | | SHALL BE IN ACCORDANCE WITH TABLE 712.4.2. | | | | | | 3B)(4) SHEET P1.03 LEVEL 1 AREA Q3 IS WHERE THE LIFT | | | STATION TIES INTO THE BUILDING DRAIN, NOTE # 29 | | | IDENTIFIES THE WASTE LINE. HERE THERE IS 2 ISSUES, THE | | | CONNECTION OF THE DISCHARGE PIPING IS TO OCCUR EITHER | | | TO THE BUILDING SEWER OR TO A WYE FITTING IN THE | | | BUILDING DRAIN. THE CONNECTION TO THE BUILDING DRAIN, | | | WYE FITTING MUST BE A MINIMUM OF 10 FEET AWAY FROM | | | OTHER PIPE CONNECTIONS OR FIXTURES TO REDUCE THE | | | LIKELIHOOD THAT DISCHARGE FROM THE PUMP/ EJECTOR WILL | | | INTERFERE WITH THE GRAVITY FLOW IN THE DRAINAGE SYSTEM. | | | | | | THERE IS A 2 INCH HUB DRAIN CONNECTION WITHIN THE 2" | | | DISCHARGE LINE OF THE SUMP/ EJECTOR PIPING SYSTEM, THIS | | | 2 INCH HUB DRAIN WILL NEED TO TIE INTO BUILDING DRAIN | | | LINE DIRECTLY. | | | | | | THE 2ND ISSUE IS THERE IS ANOTHER 2 INCH HUB DRAIN LINE | | | THAT TIES INTO THE BUILDING DRAIN LINE WITHIN THE 10 | | | FEET WHERE THE SUMP/ EJECTOR PUMP IS TYING INTO THE | | | BUILDING DRAIN LINE. WHEN VIEWING WHERE AND HOW THE | | | SUMP/ EJECTOR PUMP DISCHARGE INTO THE BUILDING DRAIN IT | | | IS DEPICTED AS THE WYE ON ITS SIDE. SEE 2010 FBC-P | | | 712.3.5 EJECTOR CONNECTION TO THE DRAINAGE SYSTEM. | | | PUMPS CONNECTED TO THE DRAINAGE SYSTEM SHALL CONNECT TO | | | THE BUILDING SEWER OR SHALL CONNECT TO A WYE FITTING IN | | | THE BUILDING DRAIN A MINIMUM OF 10 FEET (3048 MM) FROM | | | THE BASE OF ANY SOIL STACK, WASTE STACK OR FIXTURE | | | DRAIN. WHERE THE DISCHARGE LINE CONNECTS INTO | | | HORIZONTAL DRAINAGE PIPING, THE CONNECTOR SHALL BE MADE | | | THROUGH A WYE FITTING INTO THE TOP OF THE DRAINAGE | | | PIPING. | | | | | | 3C) SHEET P0.01 THE BASEMENT LEVEL WITHIN THE ACTIVE | | | LINEN STORAGE ROOM AT THE THREE COMMERCIAL WASHING | | | MACHINES THERE IS NO DRAINAGE, NO TRENCH DRAIN, ONLY A | | | 3 INCH FLOOR DRAIN. PLEASE PROVIDE THE MANUFACTURERS | | | SPECS ON THE COMMERCIAL CLOTHES WASHERS, WILL THEY BE A | | | GRAVITY DRAIN OR PUMP, IF PUMP WHAT WILL THE GPM FLOW | | | BE? WILL THESE UNITS BE USING A TRENCH DRAIN? SHOW | | | COMPLIANCE WITH | | | 2010 FBC-PLUMBING 406.3 WASTE CONNECTION. TABLE 709.1 | | | COMMERCIAL FOOTNOTES (A & G). | | | | | | 3D) SHEET P0.01 THE BASEMENT LEVEL WITHIN THE SERVICE | | | ELEVATOR B016 THE PLANS DO NOT SHOW A SUMP PUMP DETAIL | | | AS DOES THE SERVICE ELEVATOR ST4B NOTE # 9 PROVIDES | | | DETAILS ON P4.01. | | | 2010 FBC-P 1003.4 OIL SEPARATORS REQUIRED. AT REPAIR | | | GARAGES, CAR-WASHING FACILITIES, AT FACTORIES WHERE | | | OILY AND FLAMMABLE LIQUID WASTES ARE PRODUCED AND IN | | | HYDRAULIC ELEVATOR PITS, SEPARATORS SHALL BE INSTALLED | | | INTO WHICH ALL OIL-BEARING, GREASE-BEARING OR FLAMMABLE | | | WASTES SHALL BE DISCHARGED BEFORE EMPTYING INTO THE | | | BUILDING DRAINAGE SYSTEM OR OTHER POINT OF DISPOSAL. | | | | | | 3E) SHEET P0.01 THE BASEMENT LEVEL NOTE # 2 A/C | | | CONDENSATE DRAIN PIPE TO RUN BELOW BASEMENT SLAB, SIZE | | | IS NOT PROVIDED, NOTE THIS PIPE IS SHOWN ON THE FLOOR | | | PLANS TO DRAIN INTO THE SUMP PIT WHERE AS IT IS NOT | | | SHOWN ON THE DETAIL OF THE SUMP PIT, NOTE SURE AT WHAT | | | LEVEL IT WILL DISCHARGE INTO THE SUMP PIT. | | | THE OTHER ISSUE IS A/C CONDENSATE DUMPING INTO THE CITY | | | SEWER. WEST PALM BCH MUNI CODE SEC. 90-126 | | | PROHIBITIONS & LIMITATIONS OF DISCHARGE (A)GENERALLY. | | | USERS SHALL NOT DISCHARGE POLLUTANTS INTO THE WWF | | | UNLESS IN ACCORDANCE WITH THIS ARTICLE. | | | (5)STORM WATER, SURFACE WATER, GROUNDWATER, ARTESIAN | | | WELL WATER, ROOF RUNOFF, SUBSURFACE DRAINAGE, SWIMMING | | | POOL DISCHARGES, UNCONTAMINATED COOLING WATER, | | | UNPOLLUTED INDUSTRIAL PROCESS WATERS, AIR CONDITIONING | | | CONDENSATE, UNLESS SPECIFICALLY AUTHORIZED BY THE CITY | | | IN WRITING. | | | | | | 3F) FOUND, NO COMMENT. | | | | | | 3G) SHEET P0.01 THE BASEMENT LEVEL/ POOL EQUIPMENT ROOM | | | NOTE #10 INDICATES THE USE OF A SUMP PUMP TO PUMP THE | | | POOL BACK WASH TO SANITARY, THERE IS NO PIT SHOWN ON | | | THE PLANS, NOR IS THERE A NOTE PROVIDING DETAILS SIZE | | | OF PUMP OR DISCHARGE REQUIRED. SUMPS ARE TO COMPLY WITH | | | 2010 FBC-P 712. | | | | | | 3H) NOTE THE POOL EQUIPMENT ROOM IS MISSING A HOSE BIBB | | | PER SECTION 2010 FBC-B 424.1.5.9. | | | | | | 4) SHEET P1.01 LEVEL 1 AREA Q1: NOTE OUTSIDE OF THE | | | POOL STORAGE EQUIPMENT ROOM THERE IS DEPICTED HOSE BIBB | | | PLEASE INDICATE WHERE COMPLIANCE WITH SECTION 2010 | | | FBC-B 424.1.6.2 RINSE SHOWER CAN BE FOUND? | | | | | | 5) SHEET P1.02 LEVEL 1 AREA Q2: | | | | | | 5A) SHEET P1.02 LEVEL 1 AREA Q2, NOTE# 35 INDICATES CAN | | | WASH SEE P4.01 CAN WASH DETAIL: | | | 5A) (1) THE SIDE ELEVATION SECTION AND FRONT ELEVATION, | | | THERE ARE QUESTIONS, NOTE # 5 INDICATES THE HOT WATER | | | TO THE CAN WASH WILL BE 180 DEGREES BUT NOTE 4 | | | INDICATES HOSE BIBB NIBCO- SCOTT 760 (W/ CREST WASHER - | | | 100 DEGREES. THE SIDE VIEW OF THE HOSE BIBBS AND FRONT | | | VIEW IT APPEARS THERE WILL BE TO INDEPENDENT HOSE BIBBS | | | WHERE WATER CANNOT MIX AS IF IT WERE GOING THROUGH A | | | MIXING VALVE, WATER HOTTER THAN 140 DEGREES WILL NEED | | | TO COMPLY WITH: | | | 2010 FBC-P 701.7 CONNECTIONS. | | | DIRECT CONNECTION OF A STEAM EXHAUST, BLOWOFF OR DRIP | | | PIPE SHALL NOT BE MADE WITH THE BUILDING DRAINAGE | | | SYSTEM. WASTEWATER WHEN DISCHARGED INTO THE BUILDING | | | DRAINAGE SYSTEM SHALL BE AT A TEMPERATURE NOT HIGHER | | | THAN 140?F (60?C). WHEN HIGHER TEMPERATURES EXIST, | | | APPROVED COOLING METHODS SHALL BE PROVIDED. | | | | | | 5B) SHEET P1.02 LEVEL 1 AREA Q2, NOTE# 21 INDICATES A | | | NEW 750 GALLON CONCRETE VAULT TYPE GREASE INTERCEPTOR, | | | NOTE 36 SEE SHEET P3.01D FOR THE CONTINUATION OF GREASY | | | WASTE. PLEASE PROVIDE THE SIZING CALCULATIONS FOR THE | | | CONCRETE VAULT TYPE GREASE INTERCEPTOR, | | | SIZING IS TO BE IN ACCORDANCE WITH 2010 FBC-P SECTION | | | 1003.5.1 AND TABLE 1003.5.1. | | | | | | 5C) SHEET P1.02 LEVEL 1 AREA Q2, NOTES 22-25 DEALS WITH | | | FUEL LINES, PLEASE NOTE DIRECTLY ABOVE THE NEXT STORY | | | IS THE DIESEL EMERGENCY GENERATOR. DIESEL, FUEL TANKS | | | AND ASSOCIATED LINES WILL BE REVIEWED BY THE MECHANICAL | | | REVIEWER AND INSPECTED BY THE MECHANICAL INSPECTOR. | | | DETAIL P4.04. | | | | | | 6) SHEET P1.03 LEVEL 1 AREA Q3. SHEET P1.03 LEVEL 1 | | | AREA Q3, NOTE# 01 INDICATES A NEW 1,250 GALLON CONCRETE | | | VAULT TYPE GREASE INTERCEPTOR, NOTE REFERS TO SHEET | | | P4.03 THE GREASE INTERCEPTOR DETAIL. SHEET P3.00 | | | INDICATES 132 FU DRAINING INTO THE GREASE INTERCEPTOR. | | | IF SIZING USING TABLE 1003.3.4.1 THIS TABLE IS TO BE | | | USED WHEN THE DESIGN IS FOR HYDRO MECHANICAL GREASE | | | INTERCEPTORS. | | | PLEASE PROVIDE THE SIZING CALCULATIONS FOR THE CONCRETE | | | VAULT TYPE GREASE INTERCEPTOR, SIZING IS TO BE IN | | | ACCORDANCE WITH 2010 FBC-P SECTION 1003.5.1 AND TABLE | | | 1003.5.1. | | | | | | 7) SHEET P1.04 LEVEL 1 AREA Q4. KITCHEN 105 , NO GREASY | | | WASTE IS SHOWN ON THE PLANS, NOTE # 15 INDICATES SEE | | | P2.04 FOR CONTINUATION. THIS SHEET IS A EQUIPMENT | | | SCHEDULE, PLEASE PROVIDE A GREASY WASTE ISOMETRIC OR | | | WHERE TO LOCATE SUCH PLANS. PLEASE PROVIDE THE SIZING | | | CALCULATIONS FOR THE CONCRETE VAULT TYPE GREASE | | | INTERCEPTOR, SIZING IS TO BE IN ACCORDANCE WITH 2010 | | | FBC-P SECTION 1003.5.1 AND TABLE 1003.5.1. | | | | | | 8) SHEET P1.06 NOTE # 15 INDICATES 3 ELECTRIC WATER | | | HEATERS FOR USE IN THE KITCHEN THIS IS REVISION 4.5 IS | | | THIS PART OF A REVISION FOUND IN THE GAS PLAN REVISION | | | 3.5 WHERE THERE IS A DISCREPANCY IN THE AMOUNT OF | | | BOILERS FOR THE KITCHEN AND BTU'S. | | | | | | 9) SHEET P3.04 RWL # 2. WITH THE 4 " ROOF DRAIN 1106 S. | | | F. BEING ADDED TO THE HORIZONTAL LOAD OF2597 SQ FT | | | TABLE 1106.3/ 1 % SLOPE . WILL REQUIRE 5 " HORIZONTAL | | | DRAIN PIPE. WHEN 4 " RD 739 S F IS ADDED, THE LOAD IS | | | 3336 S F / 1 % SLOPE, A 6 IN HORIZONTAL PIPE WILL BE | | | REQUIRED. | | | | | | 10) SHEET P3.05: | | | 10A) SHEET P3.05 (MARK UP # 1) THE COMBINED SQUARE | | | FOOTAGE OF RWL 15 & 16 = 1748 OVER THE 1652 SQ FT @ 4.5 | | | IN/ 100 YR RAIN OF 1652 IF USING 1% SLOPE? SLOPE NOT | | | INDICATED. 2010 FBC-P TABLE 1106.3. | | | | | | 10B) SHEET P3.05 (MARK UP # 2) THE COMBINED SQUARE | | | FOOTAGE OF RWL UNKNOWN NOT MARKED & 17 = 2254 OVER THE | | | 1652 SQ FT @ 4.5 IN/ 100 YR RAIN OF 1652 IF USING 1% | | | SLOPE? SLOPE NOT INDICATED. 2010 FBC-P TABLE 1106.3. | | | | | | 11) SHEET P3.09 (MARK UP # 1) THE 2 X 770 S F= 1540 S F | | | + 603 S F+2143 SQ FT, OVER THE ALLOWED 1652 SQ FT @ 4.5 | | | IN/ 100 YR RAIN OF 1652 IF USING 1% SLOPE? SLOPE NOT | | | INDICATED. 2010 FBC-P TABLE 1106.3. | | | | | | 12) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW | | | COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | | THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR | | | PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2014-08-22 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2014-08-22 |
Time |
11:31 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2014-08-21 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2014-08-21 |
Time |
09:11 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2014-08-19 |
Time |
14:17 |
Sent To |
|
|
| Notes |
| 2014-08-21 09:26:23 | 1ST REVIEW; FBC 2010: | | | | | | THE SIGNATURE REPORT FOR ANDREW P SULLIVAN IS MISSING | | | THE FILE NAME FOR THE FOLLOWING PAGES: | | | 501, 502, 505, 508, 510, 512, 513, 514, 515, 516, 517, | | | 518, 520, 532, 555, 556, 557, 559, 560, 561, 568, 569, | | | 570, 573, 574, 576, 580, 582, 585, 586, 591, 592, 594, | | | 596, & 597. | | | | | | THE SIGNATURE REPORT FOR STEVEN FELLER IS MISSING THE | | | FILE NAME FOR THE FOLLOWING PAGES: | | | 600, 601, 608, 616, 618-624, 627, 629, 701, 708-714, | | | 717-721, 733, 734, 737, 740, 756-762, 769, 806, | | | 817-823, 826, 828, 830, 834, 836-838, 840, 841. | | | | | | THE SIGNATURE REPORT FOR MICHAEL SPRUCE IS MISSING | | | MULTIPLE PAGES: | | | | | | THE SIGNATURE REPORT FOR THE SURVEYS IS MISSING. | | | | | | SPOKE TO ALDOPHO REYNA. HE WILL SUPPLY MISSING PEDDS. | | | | | | STEVEN KENNEDY, CBO | | | CHIEF PLANS EXAMINER | | | (561) 805-6710 | | | [email protected] | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2014-08-20 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2014-08-20 |
Time |
11:32 |
Rev Time |
1.50 |
| Received By |
eschneid |
Date |
2014-08-20 |
Time |
11:32 |
Sent To |
|
|
| Notes |
| 2014-08-20 11:32:28 | PASSED W/PROVISOS | | | | | | 1) PROVISO: THE FOLLOWING CONDITION WAS LISTED IN | | | RESOLUTION NO. 329-13 AS REQUIRED PRIOR TO THE ISSUANCE | | | OF THE FIRST BUILDING PERMIT IN ORDER TO ADDRESS | | | PERMANENT CONSTRUCTION ACROSS THE PROPERTY LINE. THE | | | BUILDING OFFICIAL HAS DETERMINED THAT THE CURRENT | | | TEMPORARY CONSTRUCTION EASEMENT WILL SUFFICE FOR | | | BUILDING PERMIT TO BE ISSUED; HOWEVER, HE HAS STATED | | | THAT THE PERMANENT INSTRUMENT SHALL BE RECORDED IN | | | ACCORDANCE WITH THE CONDITION (A. BELOW) PRIOR TO | | | ISSUANCE OF THE CO OR TCO, OR THE CONNECTOR BETWEEN THE | | | HOTEL AND THE CONVENTION CENTER AND ANY OTHER | | | STRUCTURES OR SYSTEMS THAT CROSS THE SHARED PROPERTY | | | LINE SHALL BE REMOVED. | | | | | | A. PRIOR TO THE ISSUANCE OF THE SPECIFIC BUILDING | | | PERMIT FOR STRUCTURES OR SYSTEMS THAT CROSS THE SHARED | | | PROPERTY LINE WITH THE PALM BEACH COUNTY CONVENTION | | | CENTER PARCEL, TO INCLUDE WALKWAY CONNECTIONS, THE | | | POOL, POOL DECK, POOL EQUIPMENT, IRRIGATION LINES, | | | ETC., THE APPLICANT SHALL RECORD IN THE PUBLIC RECORD A | | | UNITY OF TITLE, UNITY OF CONTROL, A RESTRICTIVE | | | COVENANT, IN LIEU OF UNITY OF TITLE, OR OTHER | | | APPROPRIATE INSTRUMENT, AS APPROVED BY THE OFFICE OF | | | THE CITY ATTORNEY, TO ADDRESS THE HOTEL STRUCTURES OR | | | SYSTEMS THAT ARE ON THE CONVENTION CENTER PARCEL OR | | | WHICH CROSS THE SHARED PROPERTY LINE. | | | | | | 2) THE FOLLOWING CONDITIONS WERE LISTED IN RESOLUTION | | | NO. 329-13 AS REQUIRED PRIOR TO THE ISSUANCE OF THE | | | FIRST BUILDING PERMIT FOR VERTICAL CONSTRUCTION; | | | HOWEVER, UPON ENGINEERING SERVICES DEPARTMENT AND CITY | | | SURVEYOR REVIEW OF THE PROJECT AND RELATED PLANS, IT | | | HAS BEEN DETERMINED THAT THESE CONDITIONS SHALL BE | | | ADDRESSED PRIOR TO THE ISSUANCE OF THE CERTIFICATE OF | | | OCCUPANCY. | | | | | | A. PROVISO: RECORD EASEMENTS IN FAVOR OF THE CITY FOR | | | ANY PUBLIC SIDEWALKS OR UTILITIES ON THE HOTEL OR | | | PARKING STRUCTURE PARCELS. ****FINAL EASEMENT LOCATIONS | | | WILL BE BASED ON THE AS BUILT SURVEY OF THE SITE.**** | | | | | | B. PROVISO: SECURE A RIGHT-OF-WAY PERMIT FROM THE CITY | | | FOR THE RECONFIGURATION OF THE MEDIANS AND INSTALLATION | | | OF LANDSCAPE MATERIAL WITHIN THE FLORIDA AVENUE | | | RIGHT-OF-WAY. AS PART OF THE RECONFIGURATION OF THE | | | MEDIANS, THE APPLICANT SHALL INSTALL APPROPRIATE | | | SIGNAGE TO WARN MOTORISTS OF THE MID-BLOCK PEDESTRIAN | | | CROSSING ON FLORIDA AVENUE IN ACCORDANCE WITH THE | | | LATEST VERSION OF THE MANUAL ON UNIFORM TRAFFIC CONTROL | | | DEVICES (MUTCD). ****THE ENGINEERING SERVICES | | | DEPARTMENT HAS DETERMINED THAT IT IS TOO PREMATURE TO | | | ISSUE A RIGHT-OF-WAY PERMIT SINCE THE ACTUAL | | | RIGHT-OF-WAY WORK IS NOT SET TO BEGIN UNTIL THE | | | CONSTRUCTION IS FURTHER ALONG.**** | | | | | | 3) PROVISO: AS PART OF A PERMIT REVISION PRIOR TO THEIR | | | INSTALLATION, PROVIDE SHEET E6.02, THE FIXTURE SHEET | | | WHICH SHOWS THE SPECIFIC LIGHTING WHICH WILL BE | | | PROVIDED FOR THE ART NICHES. THIS SHEET IS REFERENCED | | | AS INCLUDED, BUT IS NOT ON THE ELECTRONIC UPLOAD. ALSO, | | | PLEASE INCLUDE THE SPEC SHEET. | | | | | | 4) PROVISO: PRIOR TO THE FIRST INSPECTION, THE | | | ARCHITECTURAL FLOOR PLAN SHEETS (A3.** SERIES) WHICH DO | | | NOT MATCH THE ELEVATIONS AND SHOW THE SOUTHERN WINDOWS | | | SHALL BE EITHER CORRECTED OR REMOVED FROM THE PERMIT | | | RECORD DRAWINGS (ANY INFORMATION SHALL BE TRANSFERRED | | | TO DRAWINGS WHICH REMAIN) SO THAT THERE IS NO FURTHER | | | CONFUSION AS TO WHICH FLOOR PLAN DESIGNS APPLY. THE | | | A4.** SERIES FLOOR PLANS SHOW THE INFORMATION CORRECTLY | | | AND HAVE BEEN STAMPED BY ZONING. | | | | | | 5) PROVISO: PRIOR TO FIRST INSPECTION, THE DATA ON | | | SHEET A0.03 SHALL BE REVISED TO BE CORRECT AND TO MATCH | | | THE MINOR AMENDMENT DATA. | | | | | | 6) PROVISO: SHEET A3.01 SHOWS DIFFERENT SQUARE FOOTAGE | | | NUMBERS FOR THE PUBLIC AREAS (RESTAURANT, BAR, ETC.) | | | THAN ON THE SUBMITTED MINOR AMENDMENT AND THE LIFE | | | SAFETY PLAN (SHEET A2.02). ADDITIONALLY, NO SQUARE | | | FOOTAGE IS PROVIDED FOR THE MARKET. PRIOR TO FIRST | | | INSPECTION, THE PLANS SHALL BE REVISED WITH ALL THE | | | NUMBERS SHOWN AND BE CONSISTENT AMONG ALL PLANS. | | | | | | 7) PRIOR TO C.O., SEPARATE PERMITS, WITH PLANS, ARE | | | REQUIRED FOR THE FOLLOWING ITEMS. THE VALUE OF THE WORK | | | SHALL BE SUBMITTED WITH EACH PERMIT AND NOT THE MAIN | | | PERMIT. FULL ZONING REVIEW WILL OCCUR UPON SUBMITTAL OF | | | THE SEPARATE PERMITS PLANS. | | | | | | A. SITE FURNITURE THAT WILL BE PERMANENTLY AFFIXED TO | | | THE GROUND (EX. TRASH CANS, BENCHES, FIRE PIT, ETC.) | | | STAFF HAS REVIEWED THE LOCATIONS OF THE SITE FURNITURE | | | AND THEY COMPLY WITH THE APPROVED SITE PLAN. | | | B. SITE LIGHTING | | | C. BICYCLE RACKS | | | D. ENTRY DRIVE - A RIGHT-OF-WAY PERMIT IS REQUIRED FOR | | | THE CONNECTION TO FLORIDA AVENUE. | | | E. CIVIL PLANS AND RIGHT-OF-WAY PERMIT (THROUGH | | | ENGINEERING SERVICES) | | | F. SIGNS - SEE COMMENT 10 FOR ADDITIONAL INFORMATION. | | | G. POOL, SPA AND POOL DECK H | | | H. FENCES/GATES - THE OVERALL HEIGHT OF THE | | | FENCE/RETAINING WALL/COLUMNS MAY NOT EXCEED EIGHT (8) | | | FEET IN HEIGHT WHEN MEASURED ON THE EXTERIOR SIDE | | | (CONVENTION CENTER SIDE) FROM GRADE. DIMENSIONS WERE | | | NOT PROVIDED. | | | I. CABANAS, INCLUDING THE TOWEL ISSUE CABANA | | | J. SUN SHADE | | | K. FOUNTAIN WALL | | | L. SIDEWALKS, COVERED WALKWAY AND OTHER ITEMS WHOLLY ON | | | THE CONVENTION CENTER PARCEL. | | | M. IRRIGATION PERMIT | | | | | | 8) ADDITIONAL COMMENTS MAY BE GENERATED BASED ON THE | | | RESUBMITTAL AND THE FULL ZONING REVIEW OF THE PLANS | | | SUBMITTED WITH THE SEPARATE PERMITS. | | | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1446. | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2014-08-12 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2014-08-12 |
Time |
16:24 |
Rev Time |
8.00 |
| Received By |
eschneid |
Date |
2014-08-04 |
Time |
08:03 |
Sent To |
|
|
| Notes |
| 2014-08-04 08:03:53 | FAILED | | | | | | PLEASE PROVIDE WRITTEN RESPONSES TO THE COMMENTS. | | | | | | 1) THE FOLLOWING CONDITION WAS LISTED IN RESOLUTION NO. | | | 329-13 AS REQUIRED PRIOR TO THE ISSUANCE OF THE FIRST | | | BUILDING PERMIT IN ORDER TO ADDRESS PERMANENT | | | CONSTRUCTION ACROSS THE PROPERTY LINE. THE BUILDING | | | OFFICIAL HAS DETERMINED THAT THE CURRENT TEMPORARY | | | CONSTRUCTION EASEMENT WILL SUFFICE FOR BUILDING PERMIT | | | TO BE ISSUED; HOWEVER, HE HAS STATED THAT THE PERMANENT | | | INSTRUMENT SHALL BE RECORDED IN ACCORDANCE WITH THE | | | CONDITION PRIOR TO ISSUANCE OF THE CO OR TCO, OR THE | | | CONNECTOR BETWEEN THE HOTEL AND THE CONVENTION CENTER | | | AND ANY OTHER STRUCTURES OR SYSTEMS THAT CROSS THE | | | SHARED PROPERTY LINE SHALL BE REMOVED. | | | | | | A. PRIOR TO THE ISSUANCE OF THE SPECIFIC BUILDING | | | PERMIT FOR STRUCTURES OR SYSTEMS THAT CROSS THE SHARED | | | PROPERTY LINE WITH THE PALM BEACH COUNTY CONVENTION | | | CENTER PARCEL, TO INCLUDE WALKWAY CONNECTIONS, THE | | | POOL, POOL DECK, POOL EQUIPMENT, IRRIGATION LINES, | | | ETC., THE APPLICANT SHALL RECORD IN THE PUBLIC RECORD A | | | UNITY OF TITLE, UNITY OF CONTROL, A RESTRICTIVE | | | COVENANT, IN LIEU OF UNITY OF TITLE, OR OTHER | | | APPROPRIATE INSTRUMENT, AS APPROVED BY THE OFFICE OF | | | THE CITY ATTORNEY, TO ADDRESS THE HOTEL STRUCTURES OR | | | SYSTEMS THAT ARE ON THE CONVENTION CENTER PARCEL OR | | | WHICH CROSS THE SHARED PROPERTY LINE. | | | | | | 2) THE FOLLOWING CONDITIONS WERE LISTED IN RESOLUTION | | | NO. 329-13 AS REQUIRED PRIOR TO THE ISSUANCE OF THE | | | FIRST BUILDING PERMIT FOR VERTICAL CONSTRUCTION; | | | HOWEVER, UPON ENGINEERING SERVICES DEPARTMENT AND CITY | | | SURVEYOR REVIEW OF THE PROJECT AND RELATED PLANS, IT | | | HAS BEEN DETERMINED THAT THESE CONDITIONS SHALL BE | | | ADDRESSED PRIOR TO THE ISSUANCE OF THE CERTIFICATE OF | | | OCCUPANCY. | | | | | | A. RECORD EASEMENTS IN FAVOR OF THE CITY FOR ANY PUBLIC | | | SIDEWALKS OR UTILITIES ON THE HOTEL OR PARKING | | | STRUCTURE PARCELS. ****FINAL EASEMENT LOCATIONS WILL BE | | | BASED ON THE AS BUILT SURVEY OF THE SITE.**** | | | | | | B. SECURE A RIGHT-OF-WAY PERMIT FROM THE CITY FOR THE | | | RECONFIGURATION OF THE MEDIANS AND INSTALLATION OF | | | LANDSCAPE MATERIAL WITHIN THE FLORIDA AVENUE | | | RIGHT-OF-WAY. AS PART OF THE RECONFIGURATION OF THE | | | MEDIANS, THE APPLICANT SHALL INSTALL APPROPRIATE | | | SIGNAGE TO WARN MOTORISTS OF THE MID-BLOCK PEDESTRIAN | | | CROSSING ON FLORIDA AVENUE IN ACCORDANCE WITH THE | | | LATEST VERSION OF THE MANUAL ON UNIFORM TRAFFIC CONTROL | | | DEVICES (MUTCD). ****THE ENGINEERING SERVICES | | | DEPARTMENT HAS DETERMINED THAT IT IS TOO PREMATURE TO | | | ISSUE A RIGHT-OF-WAY PERMIT SINCE THE ACTUAL | | | RIGHT-OF-WAY WORK IS NOT SET TO BEGIN UNTIL THE | | | CONSTRUCTION IS FURTHER ALONG.**** | | | | | | 3) REPEAT COMMENT: LIGHTING SHALL BE PROVIDED FOR THE | | | ART NICHES. WHILE A NOTE WAS ADDED TO THE ENLARGED | | | ELEVATIONS REFERRING TO THE ELECTRICAL DRAWINGS FOR THE | | | LIGHTING IN THE NICHES, THE REVIEWER IS UNABLE TO | | | LOCATE THE LIGHTING ON THE ELECTRICAL DRAWINGS. PLEASE | | | CLEARLY IDENTIFY ON WHAT SHEETS THE LIGHTING DETAILS | | | ARE LOCATED. | | | | | | 4) PARTIAL REPEAT COMMENT: THE FLOOR PLANS FAIL TO SHOW | | | THE NEW GLAZING AND ARCHITECTURAL DETAILS ON THE | | | SOUTHERN ELEVATION OF THE TOWER THAT WAS SHOWN ON THE | | | MINOR AMENDMENT AND THE REVISED ELEVATIONS. EXAMPLE | | | HALLWAY AND END ROOMS DO NOT HAVE WINDOWS. | | | | | | 5) DATA ON SHEET A0.03 SHALL BE REVISED TO MATCH THE | | | MINOR AMENDMENT DATA. | | | | | | 6) SHEET A3.01 SHOWS DIFFERENT SQUARE FOOTAGE NUMBERS | | | FOR THE PUBLIC AREAS (RESTAURANT, BAR, ETC.) THAT ON | | | THE SUBMITTED MINOR AMENDMENT AND THE LIFE SAFETY PLAN | | | (SHEET A2.02). ADDITIONALLY, NO SQUARE FOOTAGE IS | | | PROVIDED FOR THE MARKET. THE NUMBERS SHALL BE SHOWS AND | | | BE CONSISTENT AMONG ALL PLANS. | | | | | | 7) SEPARATE PERMITS, WITH PLANS, ARE REQUIRED FOR THE | | | FOLLOWING ITEMS. THE VALUE OF THE WORK SHALL BE | | | SUBMITTED WITH EACH PERMIT AND NOT THE MAIN PERMIT. | | | FULL ZONING REVIEW WILL OCCUR UPON SUBMITTAL OF THE | | | SEPARATE PERMITS PLANS. | | | | | | A. SITE FURNITURE THAT WILL BE PERMANENTLY AFFIXED TO | | | THE GROUND (EX. TRASH CANS, BENCHES, FIRE PIT, ETC.) | | | STAFF HAS REVIEWED THE LOCATIONS OF THE SITE FURNITURE | | | AND THEY COMPLY WITH THE APPROVED SITE PLAN. | | | B. SITE LIGHTING | | | C. BICYCLE RACKS | | | D. ENTRY DRIVE - A RIGHT-OF-WAY PERMIT IS REQUIRED FOR | | | THE CONNECTION TO FLORIDA AVENUE. | | | E. CIVIL PLANS AND RIGHT-OF-WAY PERMIT (THROUGH | | | ENGINEERING SERVICES) | | | F. SIGNS - SEE COMMENT 10 FOR ADDITIONAL INFORMATION. | | | G. POOL, SPA AND POOL DECK H | | | H. FENCES/GATES - THE OVERALL HEIGHT OF THE | | | FENCE/RETAINING WALL/COLUMNS MAY NOT EXCEED EIGHT (8) | | | FEET IN HEIGHT WHEN MEASURED ON THE EXTERIOR SIDE | | | (CONVENTION CENTER SIDE) FROM GRADE. DIMENSIONS WERE | | | NOT PROVIDED. | | | I. CABANAS, INCLUDING THE TOWEL ISSUE CABANA | | | J. SUN SHADE | | | K. FOUNTAIN WALL | | | L. SIDEWALKS, COVERED WALKWAY AND OTHER ITEMS WHOLLY ON | | | THE CONVENTION CENTER PARCEL. | | | M. IRRIGATION PERMIT | | | | | | 8) ADDITIONAL COMMENTS MAY BE GENERATED BASED ON THE | | | RESUBMITTAL AND THE FULL ZONING REVIEW OF THE PLANS | | | SUBMITTED WITH THE SEPARATE PERMITS. | | | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1446. | | | | | | | | | | | | | | | | | 2014-07-01 12:59:06 | 7/1/14 ZONING SENT TO ES. SG |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2014-06-09 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2014-06-09 |
Time |
10:23 |
Rev Time |
8.00 |
| Received By |
eschneid |
Date |
2014-06-09 |
Time |
10:23 |
Sent To |
|
|
| Notes |
| 2014-06-09 11:20:28 | FAILED | | | | | | PLEASE PROVIDE WRITTEN RESPONSES TO THE COMMENTS. | | | | | | 1) THE FOLLOWING ITEMS REQUIRED BY RESOLUTION NO. | | | 329-13 HAVE NOT BEEN MET. | | | | | | A. PRIOR TO THE ISSUANCE OF THE SPECIFIC BUILDING | | | PERMIT FOR STRUCTURES OR SYSTEMS THAT CROSS THE SHARED | | | PROPERTY LINE WITH THE PALM BEACH COUNTY CONVENTION | | | CENTER PARCEL, TO INCLUDE WALKWAY CONNECTIONS, THE | | | POOL, POOL DECK, POOL EQUIPMENT, IRRIGATION LINES, | | | ETC., THE APPLICANT SHALL RECORD IN THE PUBLIC RECORD A | | | UNITY OF TITLE, UNITY OF CONTROL, A RESTRICTIVE | | | COVENANT, IN LIEU OF UNITY OF TITLE, OR OTHER | | | APPROPRIATE INSTRUMENT, AS APPROVED BY THE OFFICE OF | | | THE CITY ATTORNEY, TO ADDRESS THE HOTEL STRUCTURES OR | | | SYSTEMS THAT ARE ON THE CONVENTION CENTER PARCEL OR | | | WHICH CROSS THE SHARED PROPERTY LINE. | | | | | | B. PRIOR TO THE ISSUANCE OF THE FIRST BUILDING PERMIT | | | FOR VERTICAL CONSTRUCTION, THE APPLICANT SHALL: | | | | | | I. SUBMIT A MINOR AMENDMENT SHOWING THE LOCATIONS OF | | | THE STREET LIGHTS AND THE PEDESTRIAN SCALE LIGHTING. | | | THE MINOR AMENDMENT SHALL SHOW THAT THE STREET LIGHTS | | | MEET THE DOWNTOWN MASTER PLAN SPECIFICATIONS AND SHALL | | | SPECIFY AND PROVIDE DETAILS OF THE LIGHTING FIXTURES | | | USED FOR THE PEDESTRIAN SCALE LIGHTING. NO LIGHTING | | | SHALL CONFLICT WITH PROPOSED LANDSCAPE. | | | | | | II. RECORD EASEMENTS IN FAVOR OF THE CITY FOR ANY | | | PUBLIC SIDEWALKS OR UTILITIES ON THE HOTEL. | | | | | | III. SECURE A RIGHT-OF-WAY PERMIT FROM THE CITY FOR THE | | | RECONFIGURATION OF THE MEDIANS AND INSTALLATION OF | | | LANDSCAPE MATERIAL WITHIN THE FLORIDA AVENUE | | | RIGHT-OF-WAY. AS PART OF THE RECONFIGURATION OF THE | | | MEDIANS, THE APPLICANT SHALL INSTALL APPROPRIATE | | | SIGNAGE TO WARN MOTORISTS OF THE MID-BLOCK PEDESTRIAN | | | CROSSING ON FLORIDA AVENUE IN ACCORDANCE WITH THE | | | LATEST VERSION OF THE MANUAL ON UNIFORM TRAFFIC CONTROL | | | DEVICES (MUTCD). | | | | | | IV. THE LANDSCAPE PLANS SHALL BE SUBMITTED AS A | | | LANDSCAPE PERMIT AND INCLUDE THE NOTATION AND DETAILS | | | THAT ROOT BARRIERS AND STRUCTURAL SOILS SHALL BE USED | | | FOR ALL THE OAK TREE PLANTINGS IN SIDEWALK CUTOUTS OR | | | WITHIN CLOSE PROXIMITY TO SIDEWALKS TO ENSURE PROPER | | | ROOT GROWTH WHILE LIMITING THE POTENTIAL FOR ROOT | | | DAMAGE. | | | | | | 2) THE SITE LAYOUT, INCLUDING THE ELEVATIONS, HAS | | | CHANGED. SUBMIT A MINOR PLANNED DEVELOPMENT AMENDMENT | | | TO THE PLANNING DIVISION FOR REVIEW WHICH SHOWS THE | | | PROPOSED CHANGES. | | | | | | 3) SEPARATE PERMITS, WITH PLANS, ARE REQUIRED FOR THE | | | FOLLOWING ITEMS. THE VALUE OF THE WORK SHALL BE | | | SUBMITTED WITH EACH PERMIT AND NOT THE MAIN PERMIT. | | | FULL ZONING REVIEW WILL OCCUR UPON SUBMITTAL OF THE | | | SEPARATE PERMITS PLANS. | | | | | | A. SITE FURNITURE THAT WILL BE PERMANENTLY AFFIXED TO | | | THE GROUND (EX. TRASH CANS, BENCHES, FIRE PIT, ETC.) | | | STAFF HAS REVIEWED THE LOCATIONS OF THE SITE FURNITURE | | | AND THEY COMPLY WITH THE APPROVED SITE PLAN. | | | B. SITE LIGHTING - SEE COMMENT 1)B.I FOR ADDITIONAL | | | APPLICATION REQUIREMENTS. | | | C. BICYCLE RACKS | | | D. LANDSCAPE - LANDSCAPE IN THE RIGHT-OF-WAY REQUIRES A | | | RIGHT-OF-WAY PERMIT. | | | E. ENTRY DRIVE - A RIGHT-OF-WAY PERMIT IS REQUIRED FOR | | | THE CONNECTION TO FLORIDA AVENUE. | | | F. CIVIL PLANS AND RIGHT-OF-WAY PERMIT (THROUGH | | | ENGINEERING SERVICES) | | | G. SIGNS - SEE COMMENT 10 FOR ADDITIONAL INFORMATION. | | | H. POOL, SPA AND POOL DECK - SEE COMMENT 1 | | | I. FENCES/GATES - SEE COMMENT 1 - THE OVERALL HEIGHT OF | | | THE FENCE/RETAINING WALL/COLUMNS MAY NOT EXCEED SIX (6) | | | FEET IN HEIGHT WHEN MEASURED ON THE EXTERIOR SIDE | | | (CONVENTION CENTER SIDE) FROM GRADE. DIMENSIONS WERE | | | NOT PROVIDED. SHEET LS505 AND LS506. (LS101H) | | | J. CABANAS - SEE COMMENT 1 | | | K. SUN SHADE | | | L. FOUNTAIN WALL - SEE COMMENT 1 | | | M. SIDEWALKS, COVERED WALKWAY AND OTHER ITEMS WHOLLY ON | | | THE CONVENTION CENTER PARCEL. | | | | | | 4) THE ELEVATION DRAWINGS TO NOT SHOW THE FULL | | | CONVENTION CENTER CONNECTOR (APPEARS THAT PLAN LAYERS | | | WHERE NOT TURNED ON). | | | | | | 5) THE SOUTH FACADE FOR FLOORS 3-10, AT THE END OF THE | | | CORRIDOR, MAY NOT BE A BLANK FACADE. THE CITY | | | COMMISSION APPROVED PLANS SHOW WINDOWS AND A WALL THAT | | | IS NOT FLAT AT THIS LOCATION. | | | | | | 6) THERE IS SOME EQUIPMENT SHOWN PROJECTING ABOVE THE | | | ROOF PARAPET ON THE ELEVATIONS. PER THE CITYPLACE DRI, | | | ALL ROOFTOP MECHANICAL EQUIPMENT SHALL BE SCREENED. | | | | | | 7) THE DETAIL TAG FOR THE POOL GATE D1 LS509 (NORTHERN | | | GATE) LEADS TO THE DETAIL ON SHEET LS509 WHICH DOES NOT | | | MATCH THE GATE IN PLAN VIEW ON SHEET LS103. | | | | | | 8) ADD THE NOTE TO THE EAST ELEVATION REFERENCING THAT | | | THERE WILL BE ART LOCATED IN THE NICHES, PER THE PLANS | | | APPROVED BY RESOLUTION NO. 329-13. | | | | | | 9) LIGHTING SHALL BE PROVIDED FOR THE ART NICHES. | | | | | | 10) CHANGE ALL REFERENCE TO THE CORNER SIGN (RELOCATED | | | MONUMENT SIGN) TO STATE THE APPROVED SIZE FROM | | | RESOLUTION NO. 329-11, AS STATED BELOW: | | | | | | A. THE CORNER SIGN SHALL CONTAIN A MAXIMUM TOTAL OF 240 | | | SQUARE FEET IN AREA (120 SQUARE FEET MAXIMUM PER FACE). | | | | | | B. THE CORNER SIGN SHALL BE NO GREATER THAN TWELVE (12) | | | FEET IN HEIGHT AND TEN (10) FEET IN WIDTH. | | | | | | 11) ADDITIONAL COMMENTS MAY BE GENERATED BASED ON THE | | | RESUBMITTAL AND THE FULL ZONING REVIEW OF THE PLANS | | | SUBMITTED WITH THE SEPARATE PERMITS. | | | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1446. | | | | | 2014-05-06 14:24:20 | 5/6/14 |
|
|
|