Plan Review Details - Permit 14041027
Plan Review Stops For Permit 14041027
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2014-06-28 Cont ID  
Sent By jwitmer Date 2014-06-28 Time 13:44 Rev Time 0.00
Received By jwitmer Date 2014-06-28 Time 12:34 Sent To  
Notes
2014-06-28 13:18:24BUILDING PLAN REVIEW
 PERMIT: 14041027
 ADD: 1795 PALM BEACH LAKES BLVD # W519
 CONT: TBD
 TEL: (561
  
 2010 FLORIDA BUILDING CODE W
 * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION
 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013.
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 2ND REVIEW
 DATE: SAT JUNE 27/ 2014
  
 ACTION: BUILDING PROVISO
 BUILDING APPROVED WITH EXCEPTION!
  
 1) SHEET F3.04 THE ACCESSIBLE CASH WRAP IS TO COMPLY
 WITH TTHE 2010 FBC-ACCESSIBILITY CODE 904.4 SALES AND
 SEREVICE COUNTERS WITH A MAXIMUM HEITH OF 36 IN. PLEASE
 REVIEW DETAIL # 2 AND THE LEFT SIDE OF THE CASH WRAP
 SHOWING THE ACCESSIBLE COUNTER AT 2'-10" OVER ALL
 HEIGHT. PLEASE SEE DETAIL # 4 SIDE ELEVATION INDICATING
 A 2'-10" ELEVATION PLUS AN ADDITIONAL 5 INCHES, IT
 APPEARS TO BE A TYPO.
 RED LINED DRAWINGS TO COMPLY WITH THE 2010 FBC
 ACCESSIBILITY CODE.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2014-05-25 Cont ID  
Sent By jwitmer Date 2014-05-25 Time 12:40 Rev Time 0.00
Received By jwitmer Date 2014-05-25 Time 10:48 Sent To  
Notes
2014-05-25 11:41:54BUILDING PLAN REVIEW
 PERMIT: 14041027
 ADD: 1795 PALM BEACH LAKES BLVD # W401
 CONT: TBD
 TEL: (561
  
 2010 FLORIDA BUILDING CODE W
 * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION
 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013.
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: SUN AY 25/ 2014
 ACTION: DENIED
  
 1) PLEASE CORRECT THE ADDRESS ON BOTH THE PERMIT
 APPLICATION AND NONE PROVIDED ON THE PLANS. SHEET A0.00
 THE KEY PLAN IDENTIIES THE LOCATION OF THE PROJECT
 WITHIN THE PALM BEACH OUTLET MALL AS BUILDING J2. THE
 CORRECT ADDRESS FOR THIS BUILDING IS 1795 PALM BEACH
 LAKES BLVD # W401.
  
 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING
 CODE, CHAPTER 1, ADMINISTRATION, 107.2.1 INFORMATION ON
 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS SHALL BE
 DIMENSIONED AND DRAWN UPON SUITABLE
 MATERIAL.CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT
 CLARITY TO INDICATE THE LOCATION, NATURE AND EXTENT OF
 THE WORK PROPOSED.
  
 2010 FBC-B [F] 501.2 ADDRESS IDENTIFICATION. NEW AND
 EXISTING BUILDINGS SHALL BE PROVIDED WITH APPROVED
 ADDRESS NUMBERS OR LETTERS.
  
 2) FOR THE TENANT BUILD-OUT CONTRACTOR TO START WORK
 BEFORE THE SHELL CONTRACTOR RECEIVES THEIR CERTIFICATE
 OF COMPLITION PLEASE REVIEW THE FOLLOWING REQUIREMENT.
 PB OUTLET MALLS:
 A LETTER FROM THE QUALIFIER OF BOTH THE SHELL
 CONTRACTOR (EMJ CORPORATION) AND TENANT BUILD-OUT
 CONTRACTOR MUST BE PROVIDED BEFORE TENANT BUILD-OUT
 PERMIT CAN BE ISSUED, IF THE TENANT BUILD-OUT
 CONTRACTOR WISHES TO START WORK BEFORE THE SHELL WORK
 HAS RECEIVED A CERTIFICATE OF COMPLETION, AGREEING THEY
 WILL WORK TOGETHER TO ACHIEVE CODE COMPLIANCE. THESE
 DOCUMENTS WILL NEED TO BE SIGNED BY THE QUALIFIER .
 PLEASE PROVIDE THE PERMIT NUMBER, ADDRESS WITH SUITE
 NUMBER WITHIN THE DOCUMENT.
  
 TRACY BECKER, TENANT COORDINATOR
 [email protected]
 618-514-2128
  
 3) THE COVERSHEET A0.00 OCCUPANT LOAD COUNT DOES NOT
 ROLL UP TO THE NEXT WHOKE NUMBER THEIR CAN NOT BE PARTS
 OF AN OCCUPANT. 2010 FBC-B 1004.1 SEE BOAF INFORMAL
 INTERPRETATION 5479 NOTICE: THE BUILDING OFFICIALS
 ASSOCIATION OF FLORIDA, IN COOPERATION WITH THE FLORIDA
 BUILDING COMMISSION, THE FLORIDA DEPARTMENT OF
 COMMUNITY AFFAIRS, ICC, AND INDUSTRY AND PROFESSIONAL
 EXPERTS OFFER THIS INTERPRETATION OF THE FLORIDA
 BUILDING CODE IN THE INTEREST OF CONSISTENCY IN THEIR
 APPLICATION STATEWIDE. THIS INTERPRETATION IS INFORMAL,
 NON-BINDING AND SUBJECT TO ACCEPTANCE AND APPROVAL BY
 THE LOCAL BUILDING OFFICIAL.
  
 4) SHEET A0.15 EGRESS PLAN / LIFE SAFETY PLAN
 4A) NOTE ON THE PLANS ABOUT EXIT NUMBER 3, NO EXITS ARE
 IDENTIFIED AS 1, 2 OR 3. THE OCCUPANT LOAD IS 474, X
 0,2 (FBC-B1005.1) = 94.8 INCHES OF REQUIRED EGRESS
 OPENINGS, PLEASE SHOW COMPLIANCE WITH ; 1015.2.1 TWO
 EXITS OR EXIT ACCESS DOORWAYS. EXCEPTIONS: 2. WHERE A
 BUILDING IS EQUIPPED THROUGHOUT WITH AN AUTOMATIC
 SPRINKLER SYSTEM IN ACCORDANCE WITH SECTION 903.3.1.1
 OR 903.3.1.2, THE SEPARATION DISTANCE OF THE EXIT DOORS
 OR EXIT ACCESS DOORWAYS SHALL NOT BE LESS THAN
 ONE-THIRD OF THE LENGTH OF THE MAXIMUM OVERALL DIAGONAL
 DIMENSION OF THE AREA SERVED.
 WHERE DOES THE 0.15 COME FROM.
  
 4B) COMPLIED.
  
 4C) (1)THE LIFE SAFETY / EGRESS PLAN DOES NOT PROVIDE A
 FURNITURE, KIOSK, COUNTER AAND TABLE LAYOUT OF THE
 MERCANTILE OCCUPANCY INCLUDING DRESSING ROOMS, STOCK
 ROOM,
 RESTROOM AND CORRIDORS PLEASE PROVIDE SUCH A LAYOUT AND
 SHOW EXIT SIGNS AND DIRECTIONAL IN ACCORDANCE WITH:
 2010 FBC-B 1006.3.1
 EXITS SHALL BE MARKED BY AN APPROVED SIGN READILY
 VISIBLE FROM ANY DIRECTION OF EXIT ACCESS. EVERY EXIT
 SIGN SHALL BE SUITABLY ILLUMINATED BY A RELIABLE LIGHT
 SOURCE. EXTERNALLY AND INTERNALLY ILLUMINATED SIGNS
 SHALL BE VISIBLE IN BOTH NORMAL AND EMERGENCY LIGHTING.
  
 4C)(2)1006.3.8
 WHERE THE DIRECTION OF TRAVEL TO REACH THE NEAREST EXIT
 IS NOT APPARENT, A DIRECTIONAL SIGN COMPLYING WITH
 SECTIONS 1006.3.5 OR 1006.3.6 READING ?EXIT,? OR A
 SIMILAR DESIGNATION WITH A DIRECTIONAL INDICATOR
 SHOWING THE DIRECTION OF TRAVEL SHALL BE PLACED IN
 EVERY LOCATION. DIRECTIONAL SIGNS SHALL BE LISTED.
  
 4C)(3) 1006.3.4 EXIT STAIR DOOR OR TACTILE SIGNAGE.
 TACTILE SIGNAGE STATING ?EXIT? AND COMPLYING WITH
 ICC/ANSI A117.1, AMERICAN NATIONAL STANDARD FOR
 ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES, SHALL
 BE INSTALLED ADJACENT TO THE LATCH SIDE OF THE DOOR 60
 INCHES (1524 MM) ABOVE THE FINISHED FLOOR TO THE CENTER
 LINE OF THE SIGN.
  
 5) SHEETH2 SHOWS A HIGH/ LOW DRINKING FOUNTAIN AND THEN
 2 SINGLE DRINKING FOUNTAINS WITH OUT DETAIL NUMBERS ,
 THERE IS EXTENSION LINES BUT NO INFORMATION AS TO
 CONFORMITY TO THE 2010 FL ACCESSIBILITY CODE, IF SHOWN
 ON THE PLAN THEY WILL NEED TO SHOW COMPLIANCE WITH 2010
 FL ACCESSIBILITY CODE 211.2 MINIMUM NUMBER.
 NO FEWER THAN TWO DRINKING FOUNTAINS SHALL BE PROVIDED.
 ONE DRINKING FOUNTAIN SHALL COMPLY WITH 602.1 THROUGH
 602.6 AND ONE DRINKING FOUNTAIN SHALL COMPLY WITH
 602.7.
  
 6) IF IN TTHE PLANS I DIDN'T SEE COMPLIANCE WITH 2010
 FL ACCESSIBILITY CODE 904.4 SALES AND SERVICE COUNTERS.
 SALES COUNTERS AND SERVICE COUNTERS SHALL COMPLY WITH
 904.4.1 OR 904.4.2. THE ACCESSIBLE PORTION OF THE
 COUNTER TOP SHALL EXTEND THE SAME DEPTH AS THE SALES OR
 SERVICE COUNTER TOP.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2014-07-14 Cont ID  
Sent By dhayes Date 2014-07-14 Time 16:00 Rev Time 0.00
Received By dhayes Date 2014-07-14 Time 16:00 Sent To  
Notes
2014-07-14 16:00:44DATE: 7/14/2014
 PROJECT: FOREVER 21
 PERMIT#: 14041027
 CODE: 2008 EDITION OF THE NEC
 2010 EDITION OF THE FBC
 2010 WPB AMENDMENTS TO THE FBC, CHAPTER 1,
 ADMINISTRATION, 2012 FBC SUPPLEMENTS.
  
 1ST ELECTRICAL PLAN REVIEW
 ACTION: PROVISO
  
 2) THE INTERIOR OF AN UNDERGROUND RACEWAY SHALL BE
 CONSIDERED A WET LOCATION. ALL CONDUCTORS INCLUDING LOW
 VOLTAGE DATA/COM WITHIN THE RACEWAY SHALL BE LISTED
 ACCORDINGLY. SUITABILITY FOR INSTALLATION AND USE IN
 CONFORMITY WITH THE PROVISIONS OF THIS CODE. NEC
 110.3(A)(1 THRU 8)
  
 3) A SEPARATE ELECTRICAL PERMIT APPLICATION ACCOMPANIED
 BY SHOP DRAWINGS, BATTERY CALCULATIONS, AND EQUIPMENT
 SUBMITTALS, SHALL BE SUBMITTED FOR ALL OF THE
 FOLLOWING:
 FIRE ALARM, SECURITY, CCTV, AND AUDIO/ VIDEO, NETWORK,
 AND DATA/COM.
  
 DAVID HAYES, ELECTRICAL PLANS EXAMINER, PX3421,
 561-805-6717 OR [email protected]

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2014-05-29 Cont ID  
Sent By dhayes Date 2014-05-29 Time 17:26 Rev Time 0.00
Received By dhayes Date 2014-05-29 Time 16:06 Sent To  
Notes
2014-05-29 17:26:54ELECTRICAL PROVISO:
  
 LIGHTING SHALL BE CONTROLED PER THE FBC-ENERGY SECTION
 505.
  
 A SEPARATE PERMIT INCLUDING SHOP DRAWINGS EQUIPMENT
 SPECIFICATIONS AND BATTERY CALCULATIONS.

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2014-06-18 Cont ID  
Sent By pleduc Date 2014-06-18 Time 11:18 Rev Time 0.00
Received By pleduc Date 2014-06-18 Time 11:04 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2014-05-19 Cont ID  
Sent By pleduc Date 2014-05-19 Time   Rev Time 0.00
Received By pleduc Date 2014-05-19 Time 15:30 Sent To  
Notes
2014-05-19 16:16:05THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC,
 FIRE MARSHAL, WITH THE FOLLOWING COMMENTS:
  
 SHEET AO.1.5 - PLEASE REVIEW THE LOCATION OF THE FIRE
 EXTIGUISHERS TO ENSURE COMPLIANCE WITHIN 75'. A FIRE
 INSPECTOR WILL VERIFY LOCATIONS ON FIRE INSPECTION.
  
 SHEET 3.0.1 - PLEASE INSTALL A ROOF LIGHTWEIGHT TRUSS
 SIGN. NOTICE IS REQUIRED FOR STRUCTURES WITH
 LIGHT-FRAME TRUSS-TYPE CONSTRUCTION. ANY COMMERCIAL,
 INDUSTRIAL, OR ANY MULTIUNIT RESIDENTIAL STRUCTURE OF
 THREE UNITS OR MORE WHICH USES HORIZONTAL OR VERTICAL
 LIGHT-FRAME TRUSS-TYPE CONSTRUCTION IN ANY PORTION
 SHALL BE MARKED WITH AN APPROVED SYMBOL. THE APPROVED
 SYMBOL SHALL BE PLACED WITHIN 24 INCHES TO THE LEFT OF
 THE MAIN ENTRY DOOR. A FIRE INSPECTOR WILL VERIFY ON
 FIRE INSPECTION.
  
 SHEET H2 - PLEASE INSTALL LETTERING TO READ "BY ORDER
 OF THE FIRE DEPARTMENT" FOR FIRE LANE NO PARKING SIGN.
 A FIRE INSPECTOR WILL VERIFY ON FIRE INSPECTION.

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2014-07-14 Cont ID  
Sent By dhayes Date 2014-07-14 Time 16:01 Rev Time 0.00
Received By dhayes Date 2014-06-16 Time 18:13 Sent To  
Notes
2014-06-16 18:18:23C36
  

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2014-05-29 Cont ID  
Sent By dhayes Date 2014-05-29 Time 17:27 Rev Time 0.00
Received By dhayes Date 2014-04-29 Time 14:49 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2014-07-10 Cont ID  
Sent By hmoser Date 2014-07-10 Time 11:15 Rev Time 0.00
Received By hmoser Date 2014-07-10 Time 10:59 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2014-05-14 Cont ID  
Sent By hmoser Date 2014-05-14 Time 14:42 Rev Time 0.00
Received By hmoser Date 2014-05-14 Time 14:42 Sent To  
Notes
2014-05-14 14:43:18PLAN REVIEW BY J S PX1328

Review Stop P PLUMBING
Rev No 2 Status P Date 2014-06-28 Cont ID  
Sent By jwitmer Date 2014-06-28 Time 13:44 Rev Time 0.00
Received By jwitmer Date 2014-06-28 Time 12:34 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date   Cont ID  
Sent By   Date 2014-05-25 Time   Rev Time 0.00
Received By jwitmer Date 2014-05-25 Time 10:48 Sent To  
Notes
2014-05-25 12:57:33PLUMBING PLAN REVIEW
 PERMIT: 14041027
 ADD: 1795 PALM BEACH LAKES BLVD # W401
 CONT: TBD
 TEL: (561
  
 2010 FLORIDA BUILDING CODE W
 * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION
 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013.
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: SUN AY 25/ 2014
 ACTION: DENIED
  
 1) NO INDEX OF PLANS AND NO PLUMBING DRAWINGS LABELED
 IN THE SET OF PLANS. PLUMBING RELATED REVIEW FOUND
 UNDER M1.3.0. 2010 WEST PALM BEACH AMENDMENTS TO THE
 FLORIDA BUILDING CODE, CHAPTER 1, ADMINISTRATION,
 107.3.5 MINIMUM PLAN REVIEW CRITERIA FOR BUILDINGS. THE
 EXAMINATION OF THE DOCUMENTS BY THE
 BUILDING OFFICIAL SHALL INCLUDE THE FOLLOWING MINIMUM
 CRITERIA AND DOCUMENTS:107.3.5.1 COMMERCIAL BUILDINGS,
 107.3.5.1.3 PLUMBING
 1. MINIMUM PLUMBING FACILITIES
 2. FIXTURE REQUIREMENTS
 3. WATER SUPPLY PIPING
 4. SANITARY DRAINAGE
 5. WATER HEATERS
  
 NOT UNDER MECHANICAL.
  
 2) SHEET M1.3.0 DETAIL #5 SHOWS A TRAP PRIMER BUT UNDER
 THE PLUMBING FIXTURE AND EQUIPMENT SCHEDULE NEITHER THE
 FLOOR DRAIN OR TRAP SEAL PRIMER IS LISTED.
 SHOW COMPLIANCE WITH 2010 FBC-PLUMBING 1002.2 & 1002.4.
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]

Review Stop POLICE POLICE
Rev No 1 Status N Date 2014-05-13 Cont ID  
Sent By eschneid Date 2014-05-13 Time 10:36 Rev Time 0.00
Received By eschneid Date   Time   Sent To  
Notes
2014-05-13 10:37:18CRIME PREVENTION THROUGH ENVIRONMENTAL DESIGN
 THE CITY OF WEST PALM BEACH HAS RECOGNIZED THAT
 TRADITIONAL CRIME PREVENTION STRATEGIES ARE NOT ENOUGH
 IN TODAY'S SOCIETY AND A NEW APPROACH IS NEEDED. THE
 NAME OF THIS APPROACH IS CRIME PREVENTION THROUGH
 ENVIRONMENTAL DESIGN (CPTED). CPTED ACKNOWLEDGES THE
 MANNER IN WHICH PHYSICAL SPACE IS DESIGNED OR USED HAS
 A DIRECT BEARING ON CRIME AND SECURITY.
 THE PHYSICAL ENVIRONMENT HAS A DRAMATIC EFFECT ON OUR
 OWN BEHAVIOR AND THE WAY IN WHICH WE VIEW THE BEHAVIOR
 OF OTHERS. CPTED IS A CONCEPT SUPPORTED BY A SERIES OF
 OVERLAPPING PRINCIPLES BASED ON THE RELATIONSHIP OF THE
 BUILT ENVIRONMENT TO THE PRESENCE OR ABSENCE OF
 UNDESIRABLE BEHAVIOR. THE CPTED CONCEPT IS: "THE PROPER
 DESIGN AND EFFECTIVE USE OF THE BUILT ENVIRONMENT CAN
 LEAD TO A REDUCTION IN THE INCIDENCE AND FEAR OF CRIME
 AND IMPROVEMENT IN THE QUALITY OF LIFE BY INCORPORATING
 ACCESS CONTROL, NATURAL SURVEILLANCE AND TERRITORIAL
 DEFENSIVE TACTICS.?
 CPTED THEORY IS BASED UPON THE CONTENTION THAT
 PLANNERS, DESIGNERS, ARCHITECTS, LANDSCAPERS AND LAW
 ENFORCEMENT CAN COOPERATIVELY CREATE A 'SAFE' CLIMATE
 WITHIN A BUILT ENVIRONMENT" RIGHT FROM THE BEGINNING.
 SAFETY STRIKES AT THE VERY CORE OF WHAT IS GENERALLY
 REFERRED TO IN A COMMUNITY AS "QUALITY OF LIFE." A SAFE
 ENVIRONMENT IS ONE THAT REGULAR USERS PERCEIVE AS SAFE
 AND NON-USERS (CRIMINALS) PERCEIVE AS HIGHLY RISKY TO
 FREQUENT AND IN WHICH TO COMMIT CRIMES.
 THE WEST PALM BEACH POLICE DEPARTMENT HAS OUTLINED
 GUIDELINES WE WOULD LIKE TO SEE FOLLOWED. IN ADDITION
 TO THE GUIDELINES, WE ENCOURAGE YOU TO PLEASE ADOPT
 THESE MINIMUM STANDARDS:
  
 (1) A FULLY FUNCTIONING AND OPERATIONAL CCTV SYSTEM
 CAPABLE OF RECORDING AND RETRIEVING ON SITE, AN
 IDENTIFIABLE IMAGE TO ASSIST IN OFFENDER IDENTIFICATION
 AND APPREHENSION. MONITORS FOR THE SYSTEM SHOULD BE
 PLACED IN A MANAGER'S OFFICE OR BACK ROOM, WITH A
 MONITOR IN PUBLIC VIEW FROM THE SALES FLOOR.
 (2) CAMERA COVERAGE SHOULD BE AT SENSITIVE LOCATIONS:
 (A) DOORS THAT LEADS TO THE BACK OF HOUSE (B) HALLWAYS
 THAT LEAD TO REAR EXITS (C) SALES FLOOR (D) REGISTERS
 (LOW FOR FACIAL RECOGNITION) (E) FRONT ENTRY.
 (3) DOOR THAT LEADS TO THE BACK OF HOUSE AND EXITING
 REAR DOORS SHOULD BE ALARMED WITH A SENSOR AND VIEW
 FINDER.
 (4) SILENT PANIC ALARM UNDER EACH REGISTER, ONE IN THE
 BACK OF HOUSE WORK AREA
 (5) A SECURED DROP SAFE OR CASH MANAGEMENT DEVICE FOR
 RESTRICTED ACCESS TO MONEY/CASH RECEIPTS AT THE
 REGISTER AND A SECURED DROP SAFE OR CASH MANAGEMENT
 DEVICE IN THE STORAGE AREA.
 (6) CASH OUT AREA SHOULD BE IN THE FRONT OF THE STORE,
 CLOSE TO THE ENTRANCE.
 (7) SECURE THE REGISTERS TO THE COUNTER.
 (8) INSTALL ANTI-THEFT DEVICES INCLUDING SECURITY
 TOWERS AT ENTRANCES.
 (9) USE CONVEX MIRRORS IN CORNERS AND ANTI-THEFT TAGS
 ON MERCHANDISE.
 (10) HEIGHT MARKERS AT THE ENTRANCE AND EXIT.
 (11) EMPLOYEE ACCESS CONTROL ON ALL DOORS THAT LEAD
 INTO THE BACK.
 (12) WHERE WINDOW(S) ARE PRESENT, A CLEAR AND
 UNOBSTRUCTED VIEW FROM OUTSIDE THE STORE AND IN A
 NORMAL LINE OF SIGHT OF THE CASH REGISTER AND SALES
 TRANSACTION AREA
 (13) IF INSTALLING SWING GATE AT REGISTERS THEY SHOULD
 HAVE SIMPLE ACCESS CONTROL.
 (14) ALL SHOWCASES SHOULD HAVE LOCKS AND IN THE
 EXPENSIVE SHOWCASES, CONSIDER AN ALARM.
 (15) INTERIOR SHELVING AND DISPLAYS SHOULD BE NO HIGHER
 THAN FIVE FEET, EVEN LESS IN FRONT OF WINDOWS.
  
  
 OFFICER K. TUCKER-CARSILLO
 CRIME PREVENTION UNIT
 WEST PALM BEACH POLICE DEPT
 600 BANYAN BLVD
 WEST PALM BEACH, FL 33401
 (561) 822-1620 OFFICE
 (561) 822-1648 FAX
 [email protected]
  

Review Stop Z ZONING
Rev No 2 Status P Date 2014-07-07 Cont ID  
Sent By eschneid Date 2014-07-07 Time 12:10 Rev Time 0.50
Received By eschneid Date 2014-06-25 Time 11:33 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2014-05-13 Cont ID  
Sent By eschneid Date 2014-05-13 Time 10:37 Rev Time 1.00
Received By eschneid Date 2014-05-13 Time 10:37 Sent To  
Notes
2014-05-13 13:53:03FAILED
  
 PLEASE PROVIDE WRITTEN COMMENT RESPONSES.
  
 1) THE DOOR TO THE ELECTRIC ROOM AT THE NORTHWEST
 CORNER OF THE BUILDING IS NOT SHOWN IN THE SAME
 LOCATION AS THE APPROVED SHELL PLANS. THE FLOOR PLANS
 AND ELEVATIONS REFLECT THE INCORRECT CONDITION AND
 SHALL BE CORRECTED. ALTERNATIVELY IF THE CONDITION IS
 TO CHANGE, DEMOLITION/CONSTRUCTION PLANS TO RELOCATE
 THE DOOR SHALL BE PROVIDED AS PART OF THIS SUBMITTAL.
  
 2) THE SIGNAGE REQUIRES A SEPARATE PERMIT, WITH PLANS.
  
 CONTACT ERIC SCHNEIDER @ (561) 822-1446.
2014-05-02 16:06:415/2/14