Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2014-06-11 Cont ID  
Sent By jgomez Date 2014-06-11 Time 08:52 Rev Time 0.00
Received By jgomez Date 2014-06-11 Time 08:52 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2014-04-25 Cont ID  
Sent By jgomez Date 2014-04-25 Time 17:40 Rev Time 0.00
Received By jgomez Date 2014-04-25 Time 17:32 Sent To  
Notes
2014-04-25 17:46:29RE-ROOF BUILDING REVIEW COMMENTS
 CODE: 2010 FBC.
  
 1- NOA 12-0625.02 SUBMITTED WAS SUPERSEDED BY
 MIAMI-DADE. NEED CURRENT NOA. VISIT THE MIAMI-DADE
 WEBSITE AND DOWNLOAD CURRENT NOA. DCA RULE 9N-3.
  
 2- PROVIDE FIELD WITHDRAWAL RESISTANCE TEST (TAS 105)
 AS REQUIRED BY GENERAL LIMITATION #5 AND #6 ON LAST
 PAGE OF NOA SUBMITTED. SEC. 1609 FBC.
  
 3- PROVIDE SIGNED AND SEALED RAS 117 CALCULATIONS (2
 COPIES) AS REQUIRED BY GENERAL LIMITATION #7 ON LAST
 PAGE OF NOA SUBMITTED. SEC. 1609 FBC.
  
 ***NOTE: ANY ROOF EQUIPMENT REMOVAL REQUIRES SEPARATE
 PERMIT.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICE
 (561)805-6712

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2014-06-11 Cont ID  
Sent By jgomez Date 2014-06-11 Time 09:07 Rev Time 0.00
Received By jgomez Date 2014-06-09 Time 18:18 Sent To  
Notes
2014-06-09 18:18:20TO JG DESK
  

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2014-04-25 Cont ID  
Sent By jgomez Date 2014-04-25 Time 17:32 Rev Time 0.00
Received By jgomez Date 2014-04-25 Time 17:32 Sent To  
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved