| Plan Review Stops For Permit 14040797 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2014-06-25 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-06-25 |
Time |
18:26 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2014-06-25 |
Time |
18:26 |
Sent To |
|
|
| Notes |
| 2014-06-23 09:45:10 | NEW SHEETS SUBMITTED. JG. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2014-05-19 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-05-19 |
Time |
10:58 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2014-05-19 |
Time |
10:58 |
Sent To |
|
|
| Notes |
| 2014-05-19 11:01:31 | PASSED WITH PROVISO | | | | | | REMOVE THE SHEETS THAT ARE NOT SPECIFIC TO SHOWING THE | | | LOCATION OF THE PAVILION FOUNTAIN FROM THE TWO LARGE | | | SETS OF PLANS. CLEARLY MARK THE LOCATION OF THE | | | PAVILION FOUNTAIN ON THE SITE PLANS. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2014-07-11 |
|
|
Cont ID |
|
| Sent By |
dhayes |
Date |
2014-07-11 |
Time |
14:56 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
2014-07-09 |
Time |
07:15 |
Sent To |
|
|
| Notes |
| 2014-07-11 15:00:22 | DATE: 7/9/2014 | | | PROJECT: COURTNEY LAKES FOUNTAIN | | | PERMIT#: 14040797 | | | CODE: 2008 EDITION OF THE NEC | | | 2010 EDITION OF THE FBC | | | 2010 WPB AMENDMENTS TO THE FBC, CHAPTER 1, | | | ADMINISTRATION, 2012 FBC SUPPLEMENTS. | | | | | | 4TH ELECTRICAL PLAN REVIEW | | | ACTION: PROVSO | | | | | | 1) THE PROVISIONS OF PART I AND PART V OF THE NEC | | | ARTICLE 680 SHALL APPLY TO ALL PERMANENTLY INSTALLED | | | FOUNTAINS AS DEFINED IN 680.2. NEC 680.50 | | 2014-07-10 07:16:06 | SENT TO D HAYES |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2014-07-09 |
|
|
Cont ID |
|
| Sent By |
dhayes |
Date |
2014-07-09 |
Time |
08:19 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
2014-07-09 |
Time |
08:19 |
Sent To |
|
|
| Notes |
| 2014-07-09 08:22:03 | DATE: 7/9/2014 | | | PROJECT: COURTNEY LAKES FOUNTAIN | | | PERMIT#: 14040797 | | | CODE: 2008 EDITION OF THE NEC | | | 2010 EDITION OF THE FBC | | | 2010 WPB AMENDMENTS TO THE FBC, CHAPTER 1, | | | ADMINISTRATION, 2012 FBC SUPPLEMENTS. | | | | | | 3RD ELECTRICAL PLAN REVIEW | | | ACTION: DENIED | | | | | | DUPLICATE COMMENTS: | | | | | | 1) THE PROVISIONS OF PART I AND PART V OF THE NEC | | | ARTICLE 680 SHALL APPLY TO ALL PERMANENTLY INSTALLED | | | FOUNTAINS AS DEFINED IN 680.2. NEC 680.50 | | | | | | 2) INDICATE ON THE PLANS A SINGLE LINE DIAGRAM, | | | GROUNDING DETAILS, LOAD CALCULATION, AND PANEL SCHEDULE | | | INDICATING THE AVAILABILITY OF THE CIRCUITRY AND | | | AMPACITY FOR THE INSTALLATION OF THE NEW EQUIPMENT | | | LOADS. NEC 680.6 & FBC 107.2.1 | | | | | | 3) INDICATE ON A SITE PLAN THE LOCATION OF THE | | | CIRCULATION PUMP AND DISCONNECTING MEANS, LED DRIVER, | | | AND THE SWITCHGEAR PROVIDING THE ELECTRICAL CIRCUITRY. | | | NEC 680.12, FBC 107.2.1 | | | | | | DAVID HAYES, ELECTRICAL PLANS EXAMINER, PX3421, | | | 561-805-6717 OR AT [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2014-06-24 |
|
|
Cont ID |
|
| Sent By |
dhayes |
Date |
2014-06-24 |
Time |
17:02 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
2014-06-24 |
Time |
16:39 |
Sent To |
B |
|
| Notes |
| 2014-06-24 17:02:25 | DATE: 6/24/2014 | | | PROJECT: COURTNEY LAKES FOUNTAIN | | | PERMIT#: 14040797 | | | CODE: 2008 EDITION OF THE NEC | | | 2010 EDITION OF THE FBC | | | 2010 WPB AMENDMENTS TO THE FBC, CHAPTER 1, | | | ADMINISTRATION, 2012 FBC SUPPLEMENTS. | | | | | | 2ND ELECTRICAL PLAN REVIEW | | | ACTION: DENIED | | | | | | PLEASE REVISE AND RESUBMIT THE PLANS WITH THE FOLLOWING | | | INFORMATION: | | | | | | 1) THE PROVISIONS OF PART I AND PART V OF THE NEC | | | ARTICLE 680 SHALL APPLY TO ALL PERMANENTLY INSTALLED | | | FOUNTAINS AS DEFINED IN 680.2. NEC 680.50 | | | | | | 2) INDICATE ON THE PLANS A SINGLE LINE DIAGRAM, | | | GROUNDING DETAILS, LOAD CALCULATION, AND PANEL SCHEDULE | | | INDICATING THE AVAILABILITY OF THE CIRCUITRY AND | | | AMPACITY FOR THE INSTALLATION OF THE NEW EQUIPMENT | | | LOADS. NEC 680.6 & FBC 107.2.1 | | | | | | 3) INDICATE ON A SITE PLAN THE LOCATION OF THE | | | CIRCULATION PUMP AND DISCONNECTING MEANS, LED DRIVER, | | | AND THE SWITCHGEAR PROVIDING THE ELECTRICAL CIRCUITRY. | | | NEC 680.12, FBC 107.2.1 | | | | | | 4) INDICATE ON THE PLANS THE LOCATION, WIRING METHOD, | | | AND DISCONNECTING MEANS FOR THE CIRCULATION PUMP. NEC | | | 680.12 | | | | | | DAVID HAYES, ELECTRICAL PLANS EXAMINER, PX3421, | | | 561-805-6717 OR AT [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2014-04-28 |
|
|
Cont ID |
|
| Sent By |
albarran |
Date |
2014-04-28 |
Time |
17:23 |
Rev Time |
0.00 |
| Received By |
albarran |
Date |
2014-04-28 |
Time |
17:13 |
Sent To |
P |
|
| Notes |
| 2014-04-28 17:25:33 | INCORRECT PLANS SUBMITTED ON ONE SET AND NOT ENOUGH | | | ELECTRICAL INFORMATION ON THE OTHER SET. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2014-07-11 |
|
|
Cont ID |
|
| Sent By |
dhayes |
Date |
2014-07-11 |
Time |
15:00 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
2014-07-09 |
Time |
15:00 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
dhayes |
Date |
2014-07-10 |
Time |
08:22 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
2014-07-08 |
Time |
17:48 |
Sent To |
|
|
| Notes |
| 2014-07-08 17:48:24 | TO DAH DESK | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2014-06-25 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-06-25 |
Time |
18:27 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2014-06-19 |
Time |
09:48 |
Sent To |
|
|
| Notes |
| 2014-06-23 09:49:14 | RESUBMITTAL SENT TO C13 SHELF FOR REVIEW. JG. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2014-05-19 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-05-19 |
Time |
10:58 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2014-04-23 |
Time |
17:08 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2014-06-25 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-06-25 |
Time |
18:27 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2014-06-25 |
Time |
18:27 |
Sent To |
|
|
| Notes |
| 2014-06-23 09:44:48 | NEW SHEETS SUBMITTED. JG. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2014-05-19 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-05-19 |
Time |
10:58 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2014-05-19 |
Time |
10:58 |
Sent To |
|
|
| Notes |
| 2014-04-28 17:29:24 | BACK TO C1 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2014-06-24 |
|
|
Cont ID |
|
| Sent By |
ajones |
Date |
2014-06-24 |
Time |
15:46 |
Rev Time |
0.00 |
| Received By |
ajones |
Date |
2014-06-24 |
Time |
15:46 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2014-05-02 |
|
|
Cont ID |
|
| Sent By |
avann40 |
Date |
2014-05-02 |
Time |
11:28 |
Rev Time |
0.00 |
| Received By |
ajones |
Date |
2014-05-02 |
Time |
11:28 |
Sent To |
|
|
| Notes |
| 2014-05-02 11:30:33 | 5/2/14- FAILED. PLANS SUBMITTED SHOW DIFFERENT THINGS | | | BEING DONE, NOT SURE WHAT THE PERMIT IS FOR. MORE | | | CLARIFICATION IS NEEDED. | | | | | | ANGELLA VANN | | | 561-822-1441 | | | [email protected] | | 2014-04-29 15:06:00 | 4/29/14 |
|
|