Plan Review Details - Permit 14040756
| Plan Review Stops For Permit 14040756 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2014-06-26 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2014-06-26 |
Time |
11:06 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2014-06-26 |
Time |
11:06 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2014-05-19 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2014-05-19 |
Time |
13:04 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2014-05-19 |
Time |
13:04 |
Sent To |
|
|
| Notes |
| 2014-05-19 13:08:37 | RE-ROOF SECOND BUILDING REVIEW CHECKLIST. | | | CODE; 2010 FBC. | | | | | | ***INFORMATION SUBMITTED TODAY IS THE SAME INFORMATION | | | THAT WAS DENIED THE FIRST TIME. NEED TO ADDRESS THE | | | COMMENTS FROM THE FIRST CHECKLIST. | | | | | | | | | FLAT ROOF: | | | | | | 1- SELECTED ASSEMBLY ON PAGE 27 OF NOA 13-0204.03 | | | SUBMITTED CAN'T BE USED. THIS ASSEMBLY IS LIMITED BY | | | GENERAL LIMITATION #9. THIS LIMITATION DOESN'T ALLOW | | | FOR NAIL ENHANCING TO COMPLY WITH THE DESIGN PRESSURES | | | OF SEC. 1609 FBC. NEED TO SELECT ANOTHER APPROVED | | | ASSEMBLY. | | | | | | 2- ARCHITECT TO REVISE THE RAS 117 CALCULATIONS | | | SUBMITTED. IF THE SELECTED ASSEMBLY DOESN'T MEET THE | | | DESIGN PRESSURES CALCULATED FOR THE ROOF ZONE #1, THEN | | | THE SELECTED ASSEMBLY CAN'T BE USED. SELECTED ASSEMBLY | | | IS FOR -45PSF. THE CALCULATED DESIGN PRESSURES FOR ZONE | | | 1 ARE 52.5PSF. REVISE AS REQUIRED. SEE SECTION 8.1 OF | | | RAS 117 OF 2010 FBC-TEST PROTOCOLS HVHZ. | | | | | | 3- ARCHITECT TO COORDINATE BASE SHEET FASTENING SPECS | | | FOR ROOF ZONE #1 WITH THE FASTENING SPECS SHOWN ON THE | | | SELECTED ASSEMBLY. IF THE BASE SHEET FASTENING SPECS | | | DON'T MATCH THE FASTENING SPECS SHOWN ON THE PRODUCT | | | APPROVAL SUBMITTED, THEN THE RAS 117 CALCULATIONS WON'T | | | BE CORRECT. REVISE AS REQUIRED AND COORDINATE WITH ITEM | | | # 2 ABOVE. SEC. 107.2.1 CITY AMENDMENTS TO FBC. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561)805-6712 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2014-04-23 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2014-04-23 |
Time |
15:37 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2014-04-23 |
Time |
14:38 |
Sent To |
|
|
| Notes |
| 2014-04-23 16:07:37 | RE-ROOF BUILDING REVIEW COMMENTS. | | | CODE; 2010 FBC. | | | | | | | | | FLAT ROOF: | | | | | | 1- SELECTED ASSEMBLY ON PAGE 27 OF NOA 13-0204.03 | | | SUBMITTED CAN'T BE USED. THIS ASSEMBLY IS LIMITED BY | | | GENERAL LIMITATION #9. THIS LIMITATION DOESN'T ALLOW | | | FOR NAIL ENHANCING TO COMPLY WITH THE DESIGN PRESSURES | | | OF SEC. 1609 FBC. NEED TO SELECT ANOTHER APPROVED | | | ASSEMBLY. | | | | | | 2- ARCHITECT TO REVISE THE RAS 117 CALCULATIONS | | | SUBMITTED. IF THE SELECTED ASSEMBLY DOESN'T MEET THE | | | DESIGN PRESSURES CALCULATED FOR THE ROOF ZONE #1, THEN | | | THE SELECTED ASSEMBLY CAN'T BE USED. SELECTED ASSEMBLY | | | IS FOR -45PSF. THE CALCULATED DESIGN PRESSURES FOR ZONE | | | 1 ARE 52.5PSF. REVISE AS REQUIRED. SEE SECTION 8.1 OF | | | RAS 117 OF 2010 FBC-TEST PROTOCOLS HVHZ. | | | | | | 3- ARCHITECT TO COORDINATE BASE SHEET FASTENING SPECS | | | FOR ROOF ZONE #1 WITH THE FASTENING SPECS SHOWN ON THE | | | SELECTED ASSEMBLY. IF THE BASE SHEET FASTENING SPECS | | | DON'T MATCH THE FASTENING SPECS SHOWN ON THE PRODUCT | | | APPROVAL SUBMITTED, THEN THE RAS 117 CALCULATIONS WON'T | | | BE CORRECT. REVISE AS REQUIRED AND COORDINATE WITH ITEM | | | # 2 ABOVE. SEC. 107.2.1 CITY AMENDMENTS TO FBC. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561)805-6712 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2014-06-26 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2014-06-26 |
Time |
11:06 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2014-06-26 |
Time |
09:08 |
Sent To |
|
|
| Notes |
| 2014-06-26 09:08:33 | SENT TO J. GOMEZ DESK. JW |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2014-05-19 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2014-05-19 |
Time |
13:03 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2014-05-19 |
Time |
13:03 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2014-04-23 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2014-04-23 |
Time |
14:38 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2014-04-23 |
Time |
14:38 |
Sent To |
|
|
| Notes |
|
|
|