Plan Review Details - Permit 14040755
| Plan Review Stops For Permit 14040755 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2014-04-30 |
|
|
Cont ID |
|
| Sent By |
JWITMER |
Date |
2014-04-30 |
Time |
16:16 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-04-30 |
Time |
14:03 |
Sent To |
|
|
| Notes |
| 2014-04-30 16:16:29 | BUILDING/ PLUMBING | | | PLAN REVIEW | | | REVISION: 14040755 | | | PERMIT: 13050713 | | | ADD: 313 DATURA ST | | | CONT: ANDERSON MOORE | | | TEL: (561)662-1819 | | | | | | 2010 FLORIDA BUILDING CODE W | | | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | | | 2010 EXISTING BUILDING CODE LEVEL II 701.3 | | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | | | 1ST REVIEW | | | DATE: WED. APRIL 30/ 2014 | | | ACTION: PROVIO | | | BUILDING APPROVED WITH EXCEPTION! | | | THIS PLAN HAS BEEN APPROVED PROVISIONALLY. FAILURE TO | | | CORRECT THE LISTED DEFICIENCIES IN THIS PLAN PRIOR TO | | | INSPECTION WILL RESULT IN FAILED INSPECTION(S) AND THE | | | ASSESSMENT OF RE-INSPECTION FEE(S). REVISIONS REQUIRE | | | ADDITIONAL REVIEWS WITH ASSOCIATED FEES. | | | | | | 1) SHEET A1.01 PLEASE REVIEW ROOF DRAIN RD6 ROOF INLET | | | INDICATES DRAINING INTO DS5, NOT THE DS6 LABELED 8,814 | | | SF DISCHARGE. | | | PLEASE SEE IN THE INLET FOR ROOF DRAIN 6 / 7,276 S FT | | | OF DRAINAGE? ROOF DRAINS 3 & 4 ALSO DUMP ONTO THIS ROOF | | | IS THIS FIGURED INTO THE 8,814 SQ FT, IF SO THIS WOULD | | | BE THE SAME AMOUNT TO BE DRAINED FROM RD6. | | | PLEASE CONFIRM THE DISCREPANCIES, ALSO SEE ROOF | | | SCHEDULE A103, ROOF DRAIN # 6 IS NOT PART OF THE | | | SCHEDULE. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2014-05-09 |
|
|
Cont ID |
|
| Sent By |
dhayes |
Date |
2014-05-09 |
Time |
10:59 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
2014-05-09 |
Time |
10:59 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2014-04-24 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2014-04-24 |
Time |
14:16 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2014-04-24 |
Time |
13:54 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2014-05-09 |
|
|
Cont ID |
|
| Sent By |
dhayes |
Date |
2014-05-09 |
Time |
11:46 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
2014-04-21 |
Time |
17:21 |
Sent To |
|
|
| Notes |
| 2014-04-21 17:22:31 | REVISION SENT TO B7 SHELF FOR REVIEW. JG. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2014-05-02 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2014-05-02 |
Time |
12:52 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2014-05-02 |
Time |
12:43 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2014-04-30 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2014-04-30 |
Time |
16:16 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-04-30 |
Time |
14:03 |
Sent To |
|
|
| Notes |
| 2014-04-30 16:17:38 | BUILDING/ PLUMBING | | | PLAN REVIEW | | | REVISION: 14040755 | | | PERMIT: 13050713 | | | ADD: 313 DATURA ST | | | CONT: ANDERSON MOORE | | | TEL: (561)662-1819 | | | | | | 2010 FLORIDA BUILDING CODE W | | | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | | | 2010 EXISTING BUILDING CODE LEVEL II 701.3 | | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | | | 1ST REVIEW | | | DATE: WED. APRIL 30/ 2014 | | | ACTION: PROVIO | | | BUILDING APPROVED WITH EXCEPTION! | | | THIS PLAN HAS BEEN APPROVED PROVISIONALLY. FAILURE TO | | | CORRECT THE LISTED DEFICIENCIES IN THIS PLAN PRIOR TO | | | INSPECTION WILL RESULT IN FAILED INSPECTION(S) AND THE | | | ASSESSMENT OF RE-INSPECTION FEE(S). REVISIONS REQUIRE | | | ADDITIONAL REVIEWS WITH ASSOCIATED FEES. | | | | | | 1) SHEET A1.01 PLEASE REVIEW ROOF DRAIN RD6 ROOF INLET | | | INDICATES DRAINING INTO DS5, NOT THE DS6 LABELED 8,814 | | | SF DISCHARGE. | | | PLEASE SEE IN THE INLET FOR ROOF DRAIN 6 / 7,276 S FT | | | OF DRAINAGE? ROOF DRAINS 3 & 4 ALSO DUMP ONTO THIS ROOF | | | IS THIS FIGURED INTO THE 8,814 SQ FT, IF SO THIS WOULD | | | BE THE SAME AMOUNT TO BE DRAINED FROM RD6. | | | PLEASE CONFIRM THE DISCREPANCIES, ALSO SEE ROOF | | | SCHEDULE A103, ROOF DRAIN # 6 IS NOT PART OF THE | | | SCHEDULE. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2014-05-08 |
|
|
Cont ID |
|
| Sent By |
AAPONTE |
Date |
2014-05-08 |
Time |
16:12 |
Rev Time |
0.00 |
| Received By |
aaponte |
Date |
2014-05-08 |
Time |
16:12 |
Sent To |
|
|
| Notes |
|
|
|