| 2014-04-29 09:36:00 | BUILDING PLAN REVIEW |
| | PERMIT: 14040684 |
| | ADD: 400N FLAGLER# 2202 |
| | CONT: PHILIP E. JOHNSON |
| | TEL: (561) 366-1034 |
| | |
| | 2010 FLORIDA BUILDING CODE W |
| | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA |
| | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION |
| | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. |
| | |
| | 2010 EXISTING BUILDING CODE LEVEL II 701.3 |
| | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, |
| | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS |
| | OF THE FLORIDA BUILDING CODE, BUILDING. |
| | |
| | 1ST REVIEW |
| | DATE: TUESDAY APRIL 29/ 2014 |
| | ACTION: DENIED |
| | |
| | 1) GENERAL NOTES REFERS TO THE FBC-RESIDENTIAL CODE, |
| | THIS IS A HIGH RISE BUUILDING R-2 OCCUPANCYAND REVIEWS |
| | ARE UNDER THE 2010 FBC-B & 2010 FBC EXISTING BUILDING |
| | CODE. |
| | |
| | 2) GENERAL NOTES ALSO INICATE THE USE OF WOOD PRESSURE |
| | TREATED STUDS, 2010 FBC-B 603.1 HIGH RISE BUILDINGS IN |
| | NON- BEARING WALLS FIRE RETARDANT TREATED WOOD STUDS |
| | MAY BE USED. |
| | |
| | 3) 2010 FBC-BUILDING2509.2 BASE FOR TILE.GLASS MAT |
| | WATER-RESISTANT GYPSUM BACKING PANELS, DISCRETE |
| | NONASBESTOS FIBER-CEMENT INTERIOR SUBSTRATE SHEETS OR |
| | NONASBESTOS FIBER-MAT REINFORCED CEMENT SUBSTRATE |
| | SHEETS IN COMPLIANCE WITH ASTM C 1178, C 1288 OR C 1325 |
| | AND INSTALLED IN ACCORDANCE WITH MANUFACTURER |
| | RECOMMENDATIONS SHALL BE USED AS A BASE FOR WALL TILE |
| | IN TUB AND SHOWER AREAS AND WALL AND CEILING PANELS IN |
| | SHOWER AREAS. WATER-RESISTANT GYPSUM BACKING BOARD |
| | SHALL BE USED AS A BASE FOR TILE IN WATER CLOSET |
| | COMPARTMENT WALLS WHEN INSTALLED IN ACCORDANCE WITH |
| | GA-216 OR ASTM C 840 AND MANUFACTURER RECOMMENDATIONS. |
| | REGULAR GYPSUM WALLBOARD IS PERMITTED UNDER TILE OR |
| | WALL PANELS IN OTHER WALL AND CEILING AREAS WHEN |
| | INSTALLED IN ACCORDANCE WITH GA-216 OR ASTM C 840. |
| | |
| | 4) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION |
| | & REMOVE & REPLACE ANY PAGES AS NECESSARY. A |
| | TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT |
| | NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, |
| | IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE THE |
| | CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. |
| | THANK YOU FOR YOUR ANTICIPATED COOPERATION. |
| | |