Plan Review Details - Permit 14040647
| Plan Review Stops For Permit 14040647 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
JWITMER |
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2014-04-28 |
|
|
Cont ID |
|
| Sent By |
dhayes |
Date |
2014-04-28 |
Time |
12:57 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
2014-04-28 |
Time |
12:54 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
N |
Date |
2014-04-22 |
|
|
Cont ID |
|
| Sent By |
dhayes |
Date |
2014-04-22 |
Time |
12:20 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
2014-04-22 |
Time |
12:20 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2014-04-21 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2014-04-22 |
Time |
17:01 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
2014-04-22 |
Time |
12:46 |
Sent To |
|
|
| Notes |
| 2014-04-22 12:48:00 | NEC | | | (1). 110.3 LISTING ON ALL ELECTRICAL EQUIPMENT AND | | | COMPONENTS IS REQUIRED. | | | (2) 210.8(B)(4) REQUIRES GFI PROTECTION FOR PERSONNEL | | | "OUTDOORS". | | | (3) 314.15 IN DAMP OR WET LOCATIONS, BOXES, CONDUIT | | | BODIES, AND FITTINGS SHALL BE PLACED OR EQUIPPED SO AS | | | TO PREVENT MOISTURE FROM ENTERING OR ACCUMULATING | | | WITHIN THE BOX, CONDUIT BODY, OR FITTING. BOXES, | | | CONDUIT BODIES, AND FITTINGS INSTALLED IN WET LOCATIONS | | | SHALL BE LISTED FOR USE IN WET LOCATIONS. | | | (4) 300.6 PROTECTION AGAINST CORROSION AND | | | DETERIORATION. RACEWAYS, CABLE TRAYS, CABLEBUS, | | | AUXILIARY GUTTERS, CABLE ARMOR, BOXES, CABLE SHEATHING, | | | CABINETS, ELBOWS, COUPLINGS, FITTINGS, SUPPORTS, AND | | | SUPPORT HARDWARE SHALL BE OF MATERIALS SUITABLE FOR THE | | | ENVIRONMENT IN WHICH THEY ARE TO BE INSTALLED. IF THERE | | | IS A POTENTIAL FOR SPILLAGE OF CORROSIVE MATERIALS FROM | | | VEHICLES, PLEASE COMPLY WITH 300.6. | | | | | | FBC | | | 107.2.1 "CONSTRUCTION DOCUMENTS SHOULD BE OF SUFFICIENT | | | CLARITY TO INDICATE THE LOCATION NATURE AND EXTENT OF | | | THE WORK PROPOSED." | | | NO ELEVATION IS INDICATED FOR RECEPTACLE OUTLET. PLEASE | | | PROVIDE AN ELEVATION AND SHOW METHOD(S) FOR DRAINAGE | | | FROM THE PIT FOR ACCUMULATION OF RAIN WATER, CORROSIVE | | | WASTE MATERIALS AND WASHDOWN WATER. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2014-04-25 |
Time |
12:08 |
Sent To |
|
|
| Notes |
| 2014-04-28 12:09:14 | REVISION SENT TO DAVID' S DESK FOR REVIEW. JG. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2014-04-21 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2014-04-22 |
Time |
17:01 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
2014-04-17 |
Time |
18:43 |
Sent To |
|
|
| Notes |
| 2014-04-17 18:46:03 | GAVE TO STEVE KENNEDY. CAME IN AS A REVISION TO A | | | PERMIT THAT HAD NO ELECTRICAL REVIEW. |
|
|
|