Plan Review Details - Permit 14040610
Plan Review Stops For Permit 14040610
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2014-06-13 Cont ID  
Sent By jwitmer Date 2014-06-13 Time 12:26 Rev Time 0.00
Received By jwitmer Date 2014-06-13 Time 11:57 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2014-05-20 Cont ID  
Sent By jwitmer Date 2014-05-20 Time 17:45 Rev Time 0.00
Received By jwitmer Date 2014-05-20 Time 12:35 Sent To  
Notes
2014-05-20 14:23:43BUILDING PLAN REVIEW
 PERMIT:14040610
 ADD: 300 COURTNEY LAKES
 CONT: LAGASSE POOL CONSTRUCTION
 TEL: (954)587-1000
  
 2010 FLORIDA BUILDING CODE W
 * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION
 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013.
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: TUESDAY MAY 20/2014
 ACTION: DENIED
  
 1) INCLUDED UNDER THIS PERMIT ARE ARCHITECTURAL,
 PLUMBING & ELECTRICAL SHEETS THAT WERRE REVIEWED UNDER
 THE CLUBHOUSE PERMIT (13051012) ADDRESS 290 COURTNEY
 LAKES, THEY SHOW AS REVISION # 2 UNDER THE
 ARCHITECTURAL, AND REVISION # 1 UNDER THE ELECTRICAL &
 PLUMBING SHEETS. TO BE REVIEWED UNDER A REVISION TO THE
 CLUBHOUSE PERMIT. 2010 WEST PALM BEACH AMENDMENTS TO
 THE FLORIDA BUILDING CODE, CHAPTER 1, ADMINISTRATION,
 2010 EDITION 107.3.4.2 DEFERRED SUBMITTALS,
 (REVISIONS).
  
 2) CIVIL AND HARDSCAPE PLANS WERE ALSO SUBMITTED WHICH
 ARE NOT PART OF THE POOL PACKAGE, PLEASE REMOVE THESE
 PLANS ANS SUBMIT UNDER THE APPROPRIATE PERMIT OR
 REVISION. NOTE THE POOL FENCE AND POOL DECK WILL NEED
 TO SUBMIT SEPERATE PLANS FOR REVIEW AT THIS TIME IT CAN
 NOT BE DETERMINED WHAT PLANS ARE TO BE REVIEWED UNDER
 WHICH PERMIT, THERE ARE CIVIL PLANS SUBMITTED SHOWING
 THE UNDERGROUND FIRE LINES? 2010 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION, 2010 EDITION 107.2.1.3 ADDITIONAL
 INFORMATION IS REQUIRED.
  
 3) 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, CHAPTER 1, ADMINISTRATION, 107.3.5
 MINIMUM PLAN REVIEW CRITERIA FOR BUILDINGS. SHEETS 1
 OF7 PROVIDES THE OCCUPANT LOAD OF 282 OCCUPANTS, THERE
 IS NO FORMULA OF HOW THIS OCCUPANT LOAD WAS DERIVED,
 PLEASE PROVIDE THE OCCUPANT LOAD OF THE POOL , 50 GROSS
 SWIMMING POOL WATER SURFACE AND THE POOL DECK USING 30
 GROSS SEE 2010
 FBC-B TABLE 1004.1.1.
  
 4) UNDER THE FAIR HOUSING ACT DESIGN MANUAL, CHART 2.4
 DIAGRAM 2.8 A SWIMMING POOL MUST BE LOCATED ON AN
 ACCESSIBLE ROUTE, BUT THERE IS NO REQUIREMENT THAT AN
 ACCESSIBLE ROUTE BE PROVIDED INTO THE POOL. IN
 ADDITION, A DOOR OR GATE ACCESSING THE POOL MUST MEET
 REQUIREMENT 3 AND THE ROUTE MUST PROVIDE ACCESS TO THE
 DECK AROUND THE POOL.
 WILL THERE EVER BE WHERE THE CLUBHOUSE OR FITNES CENTER
 BE RENTED OUT OR USED BY THE PUBLIC WHERE THE POOL
 WOULD NEED TO COMPLY WITH THE 2010 FL ACCESSIBILITY
 CODE SECTION 1009.2 POOL LIFTS?
  
 5) UNABLE TO LOCATE DETAILS FOR FOUNTAIN AS TO SIZE,
 LOCATION OF FOUNTAIN AND PIPING AND PUMPS TYPE OF HEADS
 IN THE FOUNTAIN. 107.2.1.3 ADDITIONAL INFORMATION IS
 REQUIRED. REMOVE THE UNNECESSARY PLANS FORM THE POOL
 AND FOUNTAIN PERMIT.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2014-05-06 Cont ID  
Sent By albarran Date 2014-05-06 Time 12:48 Rev Time 0.00
Received By albarran Date 2014-05-06 Time 11:31 Sent To  
Notes
2014-05-06 12:49:09PASSED ELECTRICAL REVIEW. PLACED REMINDER FOR NEC
 680.26(C)

Review Stop G GAS REVIEW
Rev No 1 Status N Date 2014-05-19 Cont ID  
Sent By rmcdouga Date 2014-05-19 Time 11:34 Rev Time 0.00
Received By rmcdouga Date 2014-05-19 Time 11:34 Sent To  
Notes
2014-05-19 11:37:57NO GAS RISER PLAN OR GAS PERMIT APPLICATION WAS
 SUBMITTED. A SEPARATE APPLICATION, PLANS AND REVIEW IS
 REQUIRED.

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2014-06-13 Cont ID  
Sent By jwitmer Date 2014-06-13 Time 12:27 Rev Time 0.00
Received By jwitmer Date 2014-06-04 Time 07:53 Sent To  
Notes
2014-06-04 07:54:32SENT TO J WITMER

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2014-05-20 Cont ID  
Sent By jwitmer Date 2014-05-20 Time 17:56 Rev Time 0.00
Received By jwitmer Date 2014-04-16 Time 11:47 Sent To  
Notes
2014-04-17 11:51:39IN C21

Review Stop P PLUMBING
Rev No 2 Status P Date 2014-06-13 Cont ID  
Sent By jwitmer Date 2014-06-13 Time 12:17 Rev Time 0.00
Received By jwitmer Date   Time   Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2014-05-20 Cont ID  
Sent By jwitmer Date 2014-05-20 Time 17:56 Rev Time 0.00
Received By jwitmer Date 2014-05-20 Time 12:35 Sent To  
Notes
2014-05-20 17:56:28PLUMBING PLAN REVIEW
 PERMIT:14040610
 ADD: 300 COURTNEY LAKES
 CONT: LAGASSE POOL CONSTRUCTION
 TEL: (954)587-1000
  
 2010 FLORIDA BUILDING CODE W
 * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION
 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013.
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: TUESDAY MAY 20/2014
 ACTION: DENIED
  
 1) PLEASE PROVIDE CODE COMPLIANCE WITH 2010 FBC-B
 424.1.1 SIZING MAXIMUM GALLONS PER MINUTE?
  
 2) PLEASE SHOW LOCATION AND COMPLIANCE WITH 2010 FBC-B
 424.1.3.1.5
 WALKWAYS SHALL BE PROVIDED BETWEEN THE POOL AND THE
 SANITARY FACILITIES, AND SHALL BE CONSTRUCTED OF
 CONCRETE OR OTHER NONABSORBENT MATERIAL HAVING A SMOOTH
 SLIP-RESISTANT FINISH FOR THE FIRST 15 FEET (4572 MM)
 OF THE WALKWAY MEASURED FROM THE NEAREST POOL WATER?S
 EDGE. A HOSE BIBB WITH A VACUUM BREAKER SHALL BE
 PROVIDED TO ALLOW THE DECK TO BE WASHED DOWN WITH
 POTABLE WATER.
  
 3) PLEASE SHOW LOCATION AND COMPLIANCE WITH 2010 FBC-B
 424.1.5.9 HOSE BIBBS. A HOSE BIBB WITH VACUUM BREAKER
 SHALL BE LOCATED IN THE EQUIPMENT ROOM OR AREA.
  
 3) PLEASE SHOW LOCATION AND COMPLIANCE WITH 2010 FBC-B
 424.1.6.1.4 HOSE BIBB. A HOSE BIBB WITH VACUUM BREAKER
 SHALL BE PROVIDED IN OR WITHIN 25 FEET (7620 MM) OF
 EACH RESTROOM TO ALLOW FOR EASE OF CLEANING.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  

Review Stop Z ZONING
Rev No 2 Status P Date 2014-05-15 Cont ID  
Sent By ajones Date 2014-05-15 Time 14:18 Rev Time 0.00
Received By ajones Date 2014-05-15 Time 14:18 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2014-05-06 Cont ID  
Sent By avann Date 2014-05-06 Time 14:27 Rev Time 0.00
Received By ajones Date 2014-05-06 Time 14:27 Sent To  
Notes
2014-04-21 14:54:524/21/14


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved