Plan Review Details - Permit 14040448
Plan Review Stops For Permit 14040448
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2014-05-20 Cont ID  
Sent By jwitmer Date 2014-05-20 Time 19:30 Rev Time 0.00
Received By jwitmer Date 2014-05-20 Time 18:46 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2014-04-17 Cont ID  
Sent By jwitmer Date 2014-04-17 Time 07:42 Rev Time 0.00
Received By jwitmer Date 2014-04-17 Time 05:26 Sent To  
Notes
2014-04-17 07:42:53BUILDING PLAN REVIEW
 PERMIT: 14040448
 ADD: 205 CLEMATIS ST
 CONT: BLUEWATER BUILDER
 TEL: (561)312-8477
  
 2010 FLORIDA BUILDING CODE W
 * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION
 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013.
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: THURS. APRIL 17/2014
 ACTION: DENIED
  
 1) SHEET A0.01 FIRE RESISTANCE RATINGS INDICATE THE
 DESIGN IS TO THE 2007 FBC-B. THE 2010 FBC-B HAS BEEN
 ADOPTED STATEWIDE ON MARCH 15/ 2012. PLEASE UPDATE.
  
 2) THISTENANCY IS PART OF THE THEATER PROPERTY WHICH IS
 NOT A TYPE V CONSTRUCTION, IS THERE FIRE WALLS
 SEPERATING THE TO STRUCTURES SEE FBC-B TABLE 706.4.
  
 3) SHEET A0.02 INDICATES THE STOREFRONT NOT IN
 CONTRACT, TO DATE NO PERMIT APPLICATION HAS BEEN
 SUBMITTED FOR THE REPLACEMENT FOR STOREFRONT. THE PLANS
 INDICATE A CHANGE IN GRADE OF 1/2 INCH.
 2010 FBC-ACCESS. 404.2.5 THRESHOLDS. THRESHOLDS, IF
 PROVIDED AT DOORWAYS, SHALL BE 1/2 INCH (13 MM) HIGH
 MAXIMUM. RAISED THRESHOLDS AND CHANGES IN LEVEL AT
 DOORWAYS SHALL COMPLY WITH 302 AND 303
 2010 FBC-ACCESS.303.3 BEVELED. CHANGES IN LEVEL BETWEEN
 1/4 INCH (6.4 MM) HIGH MINIMUM AND 1/2 INCH (13 MM)
 HIGH MAXIMUM SHALL BE BEVELED WITH A SLOPE NOT STEEPER
 THAN 1:2.
  
 4) THE PLAN DOES NOT INDICATE IF THE RESTROOM IS
 EXISTING OR NEW? IF NEW IT MUST COMPLY WITH THE 2010
 FBC- ACCESSIBILITY 604.3.2.
  
 5) PLEASE PROVIDE COMPLIANCE WITH FL ACCESSIBILITY
 202.4.1 DISPROPORTIONATE COST.
 ALTERATIONS MADE TO PROVIDE AN ACCESSIBLE PATH OF
 TRAVEL TO THE ALTERED AREA WILL BE DEEMED
 DISPROPORTIONATE TO THE OVERALL ALTERATION WHEN THE
 COST EXCEEDS 20% OF THE COST OF THE ALTERATION TO THE
 PRIMARY FUNCTION AREA. COSTS THAT MAY BE COUNTED AS
 EXPENDITURES REQUIRED TO PROVIDE AN ACCESSIBLE PATH OF
 TRAVEL MAY INCLUDE: (I) COSTS ASSOCIATED WITH PROVIDING
 AN ACCESSIBLE ENTRANCE AND AN ACCESSIBLE ROUTE TO THE
 ALTERED AREA; (II) COSTS ASSOCIATED WITH MAKING
 RESTROOMS ACCESSIBLE, SUCH AS INSTALLING GRAB BARS,
 ENLARGING TOILET STALLS, INSULATING PIPES, OR
 INSTALLING ACCESSIBLE FAUCET CONTROLS; (III) COSTS
 ASSOCIATED WITH PROVIDING ACCESSIBLE TELEPHONES, SUCH
 AS RELOCATING THE TELEPHONE TO AN ACCESSIBLE HEIGHT,
 INSTALLING AMPLIFICATION DEVICES, OR INSTALLING A TEXT
 TELEPHONE (TTY); (IV) COSTS ASSOCIATED WITH RELOCATING
 AN INACCESSIBLE DRINKING FOUNTAIN.
  
 202.4.2 ACCESSIBLE FEATURES IN THE EVENT OF
 DISPROPORTIONALITY.
 WHEN THE COST OF ALTERATIONS NECESSARY TO MAKE THE PATH
 OF TRAVEL TO THE ALTERED AREA FULLY ACCESSIBLE IS
 DISPROPORTIONATE TO THE COST OF THE OVERALL ALTERATION,
 THE PATH OF TRAVEL SHALL BE MADE ACCESSIBLE TO THE
 EXTENT THAT IT CAN BE MADE ACCESSIBLE WITHOUT INCURRING
 DISPROPORTIONATE COSTS. IN CHOOSING WHICH ACCESSIBLE
 ELEMENTS TO PROVIDE, PRIORITY SHOULD BE GIVEN TO THOSE
 ELEMENTS THAT WILL PROVIDE THE GREATEST ACCESS, IN THE
 FOLLOWING ORDER: (I) AN ACCESSIBLE ENTRANCE; (II) AN
 ACCESSIBLE ROUTE TO THE ALTERED AREA; (III) AT LEAST
 ONE ACCESSIBLE RESTROOM FOR EACH SEX OR A SINGLE UNISEX
 RESTROOM; (IV) ACCESSIBLE TELEPHONES; (V) ACCESSIBLE
 DRINKING FOUNTAINS; AND (VI) WHEN POSSIBLE, ADDITIONAL
 ACCESSIBLE ELEMENTS SUCH AS PARKING, STORAGE, AND
 ALARMS.
  
 EITHER THE DESIGNER OF RECORD OR CONTRACTOR TO PROVIDE
 WHERE THE MONIES WILL BE SPENT TO REACH THE 20%
 DISPROPORTIONATE COST.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2014-05-27 Cont ID  
Sent By albarran Date 2014-05-27 Time 15:25 Rev Time 0.00
Received By albarran Date 2014-05-27 Time 14:56 Sent To M
Notes
2014-05-27 15:26:36ELECTRICAL PROVISO FOR PERMIT 14040448
 1. AS PER NEC 210.8(B), ALL 125 V. SINGLE PHASE 15 & 20
 AMP RECEPTACLES INSTALLED IN KITCHENS SHALL BE GFCI
 PROTECTION, (THIS MEANS EVERY OUTLET IN THE FOOD PREP
 AREA).
 2. AS PER NEC 600.5(A), THERE SHALL BE AN ACCESSIBLE
 OUTLET FOR SIGN AT EACH ENTRANCE. (THIS MEANS BOTH
 DOORS)
 3. UNLESS INSTALLED & COMPLETED BY THE ELECTRICAL
 CONTRACTOR OF RECORD, A SEPARATE PERMIT SHALL BE
 SECURED FOR ANY LOW VOLTAGE, DATA AND/OR COMMUNICATION
 SYSTEMS.
 THESE PLANS WERE REVIEWED BY MIKE ALBARRAN, ELECTRICAL
 PLANS EXAMINER
 YOU ARE WELCOME TO REVIEW STATUS OR COMMENTS AT THE
 FOLLOWING LINK:
 HTTP://ONESTOPSHOP.WPBGOV.COM/EGOVPLUS/PERMIT/PERM_STAT
 US.ASPX
 ENTER YOUR PERMIT NUMBER (SEE SUBJECT LINE OF THIS
 EMAIL FOR YOUR PERMIT #), CLICK ON THE PERMIT NUMBER,
 AND THEN GO TO "PLAN REVIEWS" TO SEE YOUR COMMENTS (TAB
 ABOVE THE SECOND PERMIT INFORMATION).
 AFTER ISSUANCE, PLEASE CHECK YOUR PLAN CAREFULLY FOR
 COMPLIANCE WITH ANY REDLINES, NOTES, PROVISOS, OR OTHER
 PERMIT CONDITIONS.
 FOR FURTHER ASSISTANCE, PLEASE FEEL FREE TO CONTACT ME.
 I CAN BE REACHED AT 561-805-6718 OR
 [email protected]
  
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2014-04-30 Cont ID  
Sent By albarran Date 2014-04-30 Time 12:43 Rev Time 0.00
Received By albarran Date 2014-04-30 Time 11:52 Sent To  
Notes
2014-04-30 13:04:29CONDITIONALLY APPROVED WITH THE FOLLOWING PROVISOS:
 ELECTRICAL PROVISOS FOR PERMIT #14040448
 1. AS PER NEC 210.8(B) ALL 125 V. SINGLE PHASE, 15 & 20
 AMP RECEPTACLES INSTALLED IN KITCHENS SHALL HAVE GFCI
 PROTECTION. (THIS MEANS EVERY OUTLET IN FOOD PREP
 AREAS)
 2. AS PER NEC 600.5(A) THERE SHALL BE AN ACCESSIBLE
 OUTLET FOR SIGN AT EACH ENTRANCE. THIS MEANS BOTH
 DOORS.
 3. UNLESS INSTALLED & COMPLETED BY THE ELECTRICAL
 CONTRACTOR OF RECORD, A SEPARATE PERMIT SHALL BE
 SECURED FOR ANY LOW VOLTAGE, DATA AND/OR COMMUNICATION
 SYSTEMS.
 FOR ANY QUESTIONS OR COMMENTS ON THIS REVIEW, PLEASE
 CONTACT:
 MIKE ALBARRAN, ELECTRICAL PLANS EXAMINER, PX3353
 CITY OF WEST PALM BEACH DEVELOPMENT SERVICES DEPARTMENT
 PH: (561) 805-6718, EMAIL: [email protected]
  
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2014-05-19 Cont ID  
Sent By pleduc Date 2014-05-19 Time   Rev Time 0.00
Received By pleduc Date 2014-05-19 Time 10:16 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2014-04-21 Cont ID  
Sent By pleduc Date 2014-04-21 Time 12:58 Rev Time 0.00
Received By pleduc Date 2014-04-21 Time 12:34 Sent To E
Notes
2014-04-21 12:55:04THIS PLAN WAS REVIEWED BY PETER LEDUC, FIRE MARSHAL,
 WITH THE FOLLOWING COMMENTS:
  
 FIRE ALARM AND FIRE SPRINKLER SYSTEMS OR DEVICES TO BE
 FIELD VERIFIED BY FIRE INSPECTOR.
  
 THE HOOD SYSTEM SHALL BE FIELD VERIFIED FOR PROPER
 WORKING ORDER BY FIRE INSPECTOR.

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2014-05-30 Cont ID  
Sent By hmoser Date 2014-05-30 Time 09:29 Rev Time 0.00
Received By hmoser Date 2014-05-09 Time 14:35 Sent To  
Notes
2014-05-14 14:35:20B17
  

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2014-05-09 Cont ID  
Sent By albarran Date 2014-05-09 Time 09:17 Rev Time 0.00
Received By skennedy Date 2014-04-11 Time 16:26 Sent To  
Notes
2014-04-11 16:27:38SENT TO B17 SHELF FOR REVIEW. JG.

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status N Date 2014-04-17 Cont ID  
Sent By jwitmer Date 2014-04-17 Time 07:43 Rev Time 0.00
Received By jwitmer Date 2014-04-17 Time 07:43 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2014-05-30 Cont ID  
Sent By hmoser Date 2014-05-30 Time 09:29 Rev Time 0.00
Received By hmoser Date 2014-05-30 Time 09:29 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2014-04-30 Cont ID  
Sent By hmoser Date 2014-04-30 Time 11:25 Rev Time 0.00
Received By hmoser Date 2014-04-30 Time 11:08 Sent To E
Notes
2014-04-30 11:25:05PLAN OK
 SEPARATE APPLICATION PLANS AND PERMIT
 FOR VAPOR HEAT HOOD AND
 WALK IN COOLERS REQUIRED.
 PLAN REVIEW BY HAROLD MOSER
 [email protected]
 OFFICE 561-805-6732
 FAX 561-805-6676

Review Stop P PLUMBING
Rev No 2 Status P Date 2014-05-20 Cont ID  
Sent By jwitmer Date 2014-05-20 Time 19:23 Rev Time 0.00
Received By jwitmer Date 2014-05-20 Time 18:46 Sent To  
Notes
2014-05-20 19:23:55NOTE : ENDURA LOW PRO GREASE INTERCEPTOR
 FLOW RATE 25 GPM
 CAPACITY 50 LBS

Review Stop P PLUMBING
Rev No 1 Status F Date 2014-04-17 Cont ID  
Sent By jwitmer Date 2014-04-17 Time 07:19 Rev Time 0.00
Received By jwitmer Date 2014-04-17 Time 05:28 Sent To  
Notes
2014-04-17 07:18:59PLUMBING PLAN REVIEW
 PERMIT: 14040448
 ADD: 205 CLEMATIS ST
 CONT: BLUEWATER BUILDER
 TEL: (561)312-8477
  
 2010 FLORIDA BUILDING CODE W
 * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION
 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013.
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: THURS. APRIL 17/2014
 ACTION: DENIED
  
 1) PLEASE PROVIDE A DETAIL OF THE GREASE INTERCEPTOR,
 REQUIRED SERVICE SINK, WASTE RECEPTOR & GLASS WASHER
 WITH EITHER A STANDPIPE OR WASTE RECEPTOR.
  
 1A)2010 FBC-P 1003.3.5 AUTOMATIC GREASE REMOVAL
 DEVICES. WHERE AUTOMATIC GREASE REMOVAL DEVICES ARE
 INSTALLED, SUCH DEVICES SHALL BE LOCATED DOWNSTREAM OF
 EACH FIXTURE OR MULTIPLE FIXTURES IN ACCORDANCE WITH
 THE MANUFACTURER?S INSTRUCTIONS. THE AUTOMATIC GREASE
 REMOVAL DEVICE SHALL BE SIZED TO PRETREAT THE MEASURED
 OR CALCULATED FLOWS FOR ALL CONNECTED FIXTURES OR
 EQUIPMENT. READY ACCESS SHALL BE PROVIDED FOR
 INSPECTION AND MAINTENANCE.
  
 1B)2010 FBC-P DEFINITIONS: READY ACCESS. THAT WHICH
 ENABLES A FIXTURE, APPLIANCE OR EQUIPMENT TO BE
 DIRECTLY REACHED WITHOUT REQUIRING THE REMOVAL OR
 MOVEMENT OF ANY PANEL, DOOR OR SIMILAR OBSTRUCTION AND
 WITHOUT THE USE OF A PORTABLE LADDER, STEP STOOL OR
 SIMILAR DEVICE.
  
 1C) 2010 FBC-P 802.1.7 COMMERCIAL DISHWASHING MACHINES.
 THE DISCHARGE FROM A COMMERCIAL DISHWASHING MACHINE
 SHALL BE THROUGH AN AIR GAP OR AIR BREAK INTO A
 STANDPIPE OR WASTE RECEPTOR IN ACCORDANCE WITH SECTION
 802.2.
  
 1D) 2010 FBC-P 802.2 INSTALLATION. ALL INDIRECT WASTE
 PIPING SHALL DISCHARGE THROUGH AN AIR GAP OR AIR BREAK
 INTO A WASTE RECEPTOR OR STANDPIPE. WASTE RECEPTORS AND
 STANDPIPES SHALL BE TRAPPED AND VENTED AND SHALL
 CONNECT TO THE BUILDING DRAINAGE SYSTEM. ALL INDIRECT
 WASTE PIPING THAT EXCEEDS 2 FEET (610 MM) IN DEVELOPED
 LENGTH MEASURED HORIZONTALLY, OR 4 FEET (1219 MM) IN
 TOTAL DEVELOPED LENGTH, SHALL BE TRAPPED.
  
 THE GLASS WASHER HAS A HEATER IN THE UNIT THAT HAS A
 SUSTAINER HEATER THAT PROVIDES 130 DEGREE CONTINIOUS
 WATER, IF THE TANKLESS WATER HEATER IS PROVIDING 120
 DEGREE WATER WHAT STOPS THE WATER TO BE HEATED ABOVE
 140 DEGREES? PLEASE PROVIDE COMPLIANCE WITH 2010 FBC-P
  
 1E) PLEASE PROVIDE THE SIZE OF THE WASTE BRANCH FOR THE
 GREASE INTERCEPTOR, MOP /SERVICE SINK, WASTE RECEPTOR &
 GLASS WASHER. 701.7 CONNECTIONS.
 DIRECT CONNECTION OF A STEAM EXHAUST, BLOWOFF OR DRIP
 PIPE SHALL NOT BE MADE WITH THE BUILDING DRAINAGE
 SYSTEM. WASTEWATER WHEN DISCHARGED INTO THE BUILDING
 DRAINAGE SYSTEM SHALL BE AT A TEMPERATURE NOT HIGHER
 THAN 140?F (60?C). WHEN HIGHER TEMPERATURES EXIST,
 APPROVED COOLING METHODS SHALL BE PROVIDE
  
 1F) 2010 FBC-P 803.1 WASTEWATER TEMPERATURE. STEAM
 PIPES SHALL NOT CONNECT TO ANY PART OF A DRAINAGE OR
 PLUMBING SYSTEM AND WATER ABOVE 140?F (60?C) SHALL NOT
 BE DISCHARGED INTO ANY PART OF A DRAINAGE SYSTEM. SUCH
 PIPES SHALL DISCHARGE INTO AN INDIRECT WASTE RECEPTOR
 CONNECTED TO THE DRAINAGE SYSTEM.
  
 2) THE SANITARY ISOMETRIC DOES NOT SHOW THE FLOW
 CONTROL DEVICE AND REQUIRED VENT. 2010 FBC-P 1003.3.4.2
 RATE OF FLOW CONTROLS.
 GREASE INTERCEPTORS AND GREASE TRAPS SHALL BE EQUIPPED
 WITH DEVICES TO CONTROL THE RATE OF WATER FLOW SO THAT
 THE WATER FLOW DOES NOT EXCEED THE RATED FLOW. THE
 FLOW-CONTROL DEVICE SHALL BE VENTED AND TERMINATE NOT
 LESS THAN 6 INCHES (152 MM) ABOVE THE FLOOD RIM LEVEL
 OR BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER?S
 INSTRUCTIONS.
  
 3) THE GLASS WASHER, ESPRESSO & COFFEE MAKERS HAVE
 CELLINOID VALVES AND WILL NEED TO COMPLY WITH : 2010
 FBC-P 604.9 WATER HAMMER.
 THE FLOW VELOCITY OF THE WATER DISTRIBUTION SYSTEM
 SHALL BE CONTROLLED TO REDUCE THE POSSIBILITY OF WATER
 HAMMER. A WATER-HAMMER ARRESTOR SHALL BE INSTALLED
 WHERE QUICK-CLOSING VALVES ARE UTILIZED. WATER-HAMMER
 ARRESTORS SHALL BE INSTALLED IN ACCORDANCE WITH THE
 MANUFACTURER?S SPECIFICATIONS. WATER-HAMMER ARRESTORS
 SHALL CONFORM TO ASSE 1010.
  
 4) T HE GLASS WASHER, ESPRESSO & COFFEE MAKER WILL ALSO
 NEED TO COMPLY WITH 2010 FBC-P 608.16.10 COFFEE
 MACHINES AND NONCARBONATED BEVERAGE DISPENSERS.
 THE WATER SUPPLY CONNECTION TO COFFEE MACHINES AND
 NONCARBONATED BEVERAGE DISPENSERS SHALL BE PROTECTED
 AGAINST BACKFLOW BY A BACKFLOW PREVENTER CONFORMING TO
 ASSE 1022 OR BY AN AIR GAP.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  
  

Review Stop Z ZONING
Rev No 1 Status P Date 2014-05-08 Cont ID  
Sent By aaponte Date 2014-05-08 Time 16:40 Rev Time 0.00
Received By aaponte Date 2014-05-08 Time 16:40 Sent To  
Notes
2014-05-08 16:41:05AWNING AND SIGN NOT INCLUDED IN THIS PERMIT.
2014-04-14 11:33:094/14/14