| 2014-04-22 06:02:47 | BUILDING PLAN REVIEW |
| | PERMIT: 14040359 |
| | ADD: 1875 PALM BEACH LAKES SUITE # ???????? |
| | CONT: TBD |
| | TEL: (561)348-4805 LEXI |
| | |
| | 2010 FLORIDA BUILDING CODE W |
| | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA |
| | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION |
| | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. |
| | |
| | 2010 EXISTING BUILDING CODE LEVEL II 701.3 |
| | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, |
| | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS |
| | OF THE FLORIDA BUILDING CODE, BUILDING. |
| | |
| | 1ST REVIEW |
| | DATE: TUESDAY APRIL 22/ 2014 |
| | ACTION: DENIED |
| | |
| | 1) THE PERMIT APPLICATION NOR THE PLANS IDENTIFY THE |
| | TENANT SUITE NUMBER. 2010 WEST PALM BEACH AMENDMENTS TO |
| | THE FLORIDA BUILDING CODE, CHAPTER 1, ADMINISTRATION, |
| | 2010 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. |
| | CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT CLARITY |
| | TO INDICATE THE LOCATION, ALSO WPB MUNI CODE SECTION |
| | 78-6 & FBC-B 501.2. |
| | |
| | 2) PB OUTLET MALLS: |
| | A LETTER FROM THE QUALIFIER OF BOTH THE SHELL |
| | CONTRACTOR (EMJ CORPORATION) AND TENANT BUILD-OUT |
| | CONTRACTOR MUST BE PROVIDED BEFORE TENANT BUILD-OUT |
| | PERMIT CAN BE ISSUED, IF THE TENANT BUILD-OUT |
| | CONTRACTOR WISHES TO START WORK BEFORE THE SHELL WORK |
| | HAS RECEIVED A CERTIFICATE OF COMPLETION, AGREEING THEY |
| | WILL WORK TOGETHER TO ACHIEVE CODE COMPLIANCE. THESE |
| | DOCUMENTS WILL NEED TO BE SIGNED BY THE QUALIFIER. |
| | |
| | 3) THE PLANS DO NOT HAVE THE STAMP APPROVED BY THE NEW |
| | ENGLAND DEVELOPMENT PALM BEACH OUTLET SKY GROUP TENANT |
| | COORDINATION. |
| | |
| | 4) SHEET A0.3 NOTE 7 INDICATES FUTURE CUSTOMER FITTING |
| | ROOM WHEREAS SHEET AA.2.2-4 DETAIL 1 INTRODUCES THIS |
| | AREA AS WOMENS DRESSING ROOMS. NO FITTING ROOMS ARE |
| | INDICATED ON PLANS FOR MEN OR HANDICAPPED MEN. PLEASE |
| | REVIEW: |
| | 2010 FL ACCESSIBILITY CODE 103 EQUIVALENT FACILITATION |
| | NOTHING IN THESE REQUIREMENTS PREVENTS THE USE OF |
| | DESIGNS, PRODUCTS, OR TECHNOLOGIES AS ALTERNATIVES TO |
| | THOSE PRESCRIBED, PROVIDED THEY RESULT IN SUBSTANTIALLY |
| | EQUIVALENT OR GREATER ACCESSIBILITY AND USABILITY. |
| | DEPARTURE FROM THE EXPLICIT TECHNICAL AND SCOPING |
| | REQUIREMENTS OF THIS CODE FOR ANY ELEMENT VOIDS ANY |
| | OTHERWISE APPLICABLE PRESUMPTION OF REBUTTABLE EVIDENCE |
| | THAT THE ELEMENT HAS BEEN CONSTRUCTED OR ALTERED IN |
| | ACCORDANCE WITH THE MINIMUM ACCESSIBILITY REQUIREMENTS |
| | OF THE ADA. |
| | ADVISORY 103 EQUIVALENT FACILITATION. |
| | THE RESPONSIBILITY FOR DEMONSTRATING EQUIVALENT |
| | FACILITATION IN THE EVENT OF A CHALLENGE RESTS WITH THE |
| | COVERED ENTITY. WITH THE EXCEPTION OF TRANSIT |
| | FACILITIES, WHICH ARE COVERED BY REGULATIONS ISSUED BY |
| | THE DEPARTMENT OF TRANSPORTATION, THERE IS NO PROCESS |
| | FOR CERTIFYING THAT AN ALTERNATIVE DESIGN PROVIDES |
| | EQUIVALENT FACILITATION. |
| | US DEPARTMENT OF JUSTICE ?CERTIFICATION? OF THE FLORIDA |
| | ACCESSIBILITY CODE AS SUBSTANTIALLY EQUIVALENT TO THE |
| | ADA STANDARDS FOR ACCESSIBLE DESIGN MEANS THE CODE |
| | MEETS OR EXCEEDS THE MINIMUM REQUIREMENTS OF TITLE III |
| | OF THE ADA FOR ACCESSIBILITY AND USABILITY OF |
| | FACILITIES COVERED BY TITLE III. CERTIFICATION PROVIDES |
| | PRIVATE ENTITIES, COMPLYING WITH THE FLORIDA CODE A |
| | ?PRESUMPTION OF REBUTTABLE EVIDENCE? OF COMPLIANCE WITH |
| | THE ADA TITLE III REGULATIONS. HOWEVER, THE |
| | ?PRESUMPTION? APPLIES ONLY IF THE EXPLICIT REQUIREMENTS |
| | OF THE CODE ARE MET. EQUIVALENT FACILITATION IS |
| | AUTHORIZED FOR ALTERNATE METHODS OF PROVIDING |
| | ACCESSIBILITY BUT THOSE ALTERNATE METHODS WILL NOT BE |
| | AFFORDED THE ?PRESUMPTION.? |
| | |
| | 5) SHEET A5.1 INDICATES THE USE OF CARPET THROUGH OUT |
| | THE STORE, THERE ARE 2 NOTE THAT DEAL WITH CARPET BUT |
| | NONE THAT INDICATE CONFORMANCE WITH 2010 FBC-B |
| | 804.4.1 MINIMUM CRITICAL RADIANT FLUX. |
| | INTERIOR FLOOR FINISH AND FLOOR COVERING MATERIALS IN |
| | EXIT ENCLOSURES, EXIT PASSAGEWAYS AND CORRIDORS SHALL |
| | NOT BE LESS THAN CLASS I IN GROUPS I-1, I-2 AND I-3 AND |
| | NOT LESS THAN CLASS II IN GROUPS A, B, E, H, M, R-1, |
| | R-2 AND S. IN ALL AREAS, FLOOR COVERING MATERIALS SHALL |
| | COMPLY WITH THE DOCFF-1 ?PILL TEST? (CPSC 16 CFR, PART |
| | 1630). |
| | |
| | EXCEPTION: WHERE A BUILDING IS EQUIPPED THROUGHOUT WITH |
| | AN AUTOMATIC SPRINKLER SYSTEM IN ACCORDANCE WITH |
| | SECTION 903.3.1.1 OR 903.3.1.2, CLASS II MATERIALS ARE |
| | PERMITTED IN ANY AREA WHERE CLASS I MATERIALS ARE |
| | REQUIRED, AND MATERIALS COMPLYING WITH THE DOC FF-1 |
| | ?PILL TEST? (CPSC 16 CFR, PART 1630) ARE PERMITTED IN |
| | ANY AREA WHERE CLASS II MATERIALS ARE REQUIRED. |
| | |
| | 6) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION |
| | & REMOVE & REPLACE ANY PAGES AS NECESSARY. A |
| | TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT |
| | NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, |
| | IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE THE |
| | CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. |
| | THANK YOU FOR YOUR ANTICIPATED COOPERATION. |
| | |
| | JAMES A. WITMER CBO |
| | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| | TEL: 561-805-6715 |
| | FAX: 561-805-6676 |
| | E-MAIL: [email protected] |
| | |
| | |