| Plan Review Stops For Permit 14040298 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2014-08-27 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2014-08-27 |
Time |
18:08 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2014-08-27 |
Time |
18:08 |
Sent To |
|
|
| Notes |
| 2014-08-27 18:11:16 | ***PROVISO*** | | | | | | SEPARATE PERMIT REQUIRED FOR ROOF. SUBMIT PRODUCT | | | APPROVALS, SELECT ASSEMBLY PROPOSED, AND ENGINEERING | | | FOR ENHANCED FASTENING. | | | | | | ASSEMBLY SELECTED AND SUBMITTED FOR REVIEW HAD A | | | LIMITATION OF -52.5. ZONE 1 REQUIREMENT IS 59.38. SEE | | | RAS 117 8.1, DESIGN PRESSURE FOR THE SELECTED ASSEMBLY | | | IS TO APPLY TO ZONE 1. | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2014-04-26 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2014-04-26 |
Time |
13:58 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2014-04-26 |
Time |
13:58 |
Sent To |
|
|
| Notes |
| 2014-04-26 14:26:22 | ****CORRECTIONS**** | | | ****REVISED 6/14 TO REMOVE REFERENCE TO FBC 2010 | | | RESIDENTIAL 301.2.1.1 AND CHANGE CODE REFERENCE TO | | | 301.1.**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | 1. FBC 107.2.1, ALL INFORMATINO, DRAWINGS, | | | SPECIFICATIONS AND ACCOMPANYING DATA SHALL BEAR THE | | | NAME AND SIGNATURE OF THE PERSON RESPONSIBLE FOR THE | | | DESIGN. | | | | | | 2. SHEET 2.0, PAVER WORK PROPOSED WHICH IS NOT LOCATED | | | WITHIN THE BOUNDARIES OF THE PROPERTY FOR THIS PERMIT | | | APPLICATION. WORK ON ANOTHER PARCEL WILL REQUIRE A | | | SEPARATE PERMIT. | | | | | | 3. DRIVEWAY/PAVER WORK PROPOSED REQUIRES A SEPARATE | | | PERMIT, FBC 107. PERMIT #14040299 FOR PAVERS WAS | | | SUBMITTED. IT IS SUGGESTED THAT, WHEN RESUBMITTING, | | | PLANS RELATING TO THE PAVER WORK BE RESUBMITTED | | | SEPARATELY FROM THE PATIO/PORCH PERMIT. THIS WILL HELP | | | TO EXPEDITE BOTH PERMITS. | | | | | | 4. COVER SHEET STATES THIS IS A LEVEL 2 ALTERATION; SEE | | | FBC 2010 EXISTING BUILDING 202 AND REVISE. | | | | | | 5. FBC 2010 RESIDENTIAL 301.1, PLAN STATES THAT THIS | | | DESIGN IS IN ACCORDANCE WITH ASCE7-10. IF PLANS ARE NOT | | | PREPARED BY A DESIGN PROFESSIONAL, PROVIDE CALCULATIONS | | | FOR STRUCTURAL ELEMENTS (CONNECTORS, FOOTING SIZES, | | | COLUMN SIZES, SPANS, ETC). | | | | | | 6. ZONING HAS REDLINED SHEETS 2.0, 5.0, 9.0, AND OTHER | | | SHEETS. PLEASE INCORPORATE THE CHANGES INTO THE PLAN, | | | ALL SHEETS, AS THERE IS A REDUCTION IN SIZE AND AFFECTS | | | OTHER SHEETS, FBC 107. | | | | | | 7. FLORIDA STATE OR LOCAL PRODUCT APPROVAL REQUIRED FOR | | | THE SHINGLE ROOF, FBC 2010 RESIDENTIAL 301, FAC9N-3. | | | | | | 8. FOR THE FLAT ROOF, PROVIDE A CURRENT PRODUCT | | | APPROVAL. THE NOA SUBMITTED HAS BEEN SUPERSEDED. THE | | | CURRENT VERSION OF THIS APPROVAL IS AVAILABLE AT WWW.MI | | | AMIDADE.GOV/BUILDING/LIBRARY/PRODUCTCONTROL/NOA/1207161 | | | 8.PDF. PROVIDE TWO SETS. | | | | | | 9. FOR THE FLAT ROOF, INDICATE WHICH APPROVED ASSEMBLY | | | IS PROPOSED. | | | | | | 10. FOR THE FLAT ROOF, PROVIDE ENGINEERING FOR THE | | | ENHANCED FASTENING REQUIRED. | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2014-09-04 |
|
|
Cont ID |
|
| Sent By |
dhayes |
Date |
2014-09-04 |
Time |
13:02 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
2014-09-04 |
Time |
12:35 |
Sent To |
|
|
| Notes |
| 2014-09-04 13:04:43 | DATE: 9/4/2014 | | | PROJECT: COVERED PATIO | | | PERMIT#: 14040298 | | | CODE: 2008 EDITION OF THE NEC | | | 2010 EDITION OF THE FBC | | | 2010 WPB AMENDMENTS TO THE FBC, CHAPTER 1, | | | ADMINISTRATION, 2012 FBC SUPPLEMENTS. | | | | | | 1ST ELECTRICAL PLAN REVIEW | | | ACTION: PROVISO | | | | | | WHEN ALTERATIONS, REPAIRS, OR ADDITIONS REQUIRING A | | | PERMIT OCCUR, OR WHEN ONE OR MORE SLEEPING ROOMS ARE | | | ADDED OR CREATED IN EXISTING DWELLINGS, THE INDIVIDUAL | | | DWELLING UNIT SHALL BE EQUIPPED WITH SMOKE ALARMS | | | LOCATED AS REQUIRED FOR NEW DWELLINGS. FBC-RESIDENTIAL | | | 314 AND 315. | | | | | | DAVID HAYES, ELECTRICAL PLANS EXAMINER, PX3421, | | | 561-805-6717 OR [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2014-05-07 |
|
|
Cont ID |
|
| Sent By |
albarran |
Date |
2014-05-07 |
Time |
17:31 |
Rev Time |
0.00 |
| Received By |
albarran |
Date |
2014-05-07 |
Time |
16:26 |
Sent To |
|
|
| Notes |
| 2014-05-07 17:37:58 | FAILED ELECTRICAL REVIEW 5/7/14 | | | | | | 1 APPLICABLE ELECTRICAL CODE IN FORCE IS THE 2008 | | | EDITION OF THE NEC | | | 2. ARC-FAULT REQUIREMENTS AS PER THE CURRENT CODE DO | | | NOT MATCH THE NOTES AS SUBMITTED. | | | 3. NEED BETTER DETAIL ON THE ELECTRICAL PAGE TO SHOW | | | WHAT AREA WILL BE ENCLOSED AND WHAT WILL BE OPEN. | | | 4. ALL EXTERIOR OUTLETS SHALL BE GFCI PROTECTED. | | | 5. THE DISCONNECT FOR THE CONDENSING UNIT SHALL BE | | | WITHIN SIGHT OF EQUIPMENT. | | | 6. THE SERVICED OUTLET REQUIRED BY 210.63 SHALL NOT BE | | | BEHIND THE UNIT. | | | 7. MAKE MENTION OF THE NEC 314.27(A) REQUIREMENT FOR | | | THE CEILING BOXES. | | | | | | | | | FOR ANY QUESTIONS OR COMMENTS ON THIS REVIEW, PLEASE | | | CONTACT: | | | MIKE ALBARRAN, ELECTRICAL PLANS EXAMINER, PX3353 | | | CITY OF WEST PALM BEACH DEVELOPMENT SERVICES DEPARTMENT | | | PH: (561) 805-6718, EMAIL: [email protected] | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2014-09-04 |
|
|
Cont ID |
|
| Sent By |
dhayes |
Date |
2014-09-04 |
Time |
13:04 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
2014-06-30 |
Time |
18:15 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
P |
Date |
2014-05-17 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2014-05-17 |
Time |
12:20 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2014-04-09 |
Time |
10:03 |
Sent To |
|
|
| Notes |
| 2014-04-26 14:28:46 | R08 | | | | | 2014-04-09 20:10:13 | 4/9 TO MISC 2 | | | | | 2014-04-09 10:04:13 | SENT TO ZONING. JW |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2014-08-30 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2014-08-30 |
Time |
09:29 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2014-08-30 |
Time |
09:29 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2014-05-17 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2014-05-17 |
Time |
12:20 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2014-05-17 |
Time |
12:20 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
N |
Date |
2014-08-27 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2014-08-27 |
Time |
18:11 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2014-08-27 |
Time |
18:11 |
Sent To |
|
|
| Notes |
| 2014-08-27 18:17:00 | SEPARATE PERMIT REQUIRED FOR ROOF | | | ASSEMBLY SELECTED HAD A LIMITATION OF -52.5. ZONE 1 | | | REQUIREMENT IS 59.38. SEE RAS 117 8.1, DESIGN PRESSURE | | | FOR THE SELECTED ASSEMBLY IS TO APPLY TO ZONE 1. | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2014-07-08 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2014-07-08 |
Time |
14:47 |
Rev Time |
0.00 |
| Received By |
sgraham |
Date |
2014-07-08 |
Time |
14:47 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2014-04-09 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2014-04-09 |
Time |
14:31 |
Rev Time |
0.00 |
| Received By |
sgraham |
Date |
2014-04-09 |
Time |
14:31 |
Sent To |
B |
|
| Notes |
|
|