Plan Review Details - Permit 14040145
Plan Review Stops For Permit 14040145
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2014-06-10 Cont ID  
Sent By jwitmer Date 2014-06-10 Time 16:08 Rev Time 0.00
Received By jwitmer Date 2014-06-10 Time 16:07 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2014-04-21 Cont ID  
Sent By jwitmer Date 2014-04-21 Time 06:18 Rev Time 0.00
Received By jwitmer Date 2014-04-21 Time 05:53 Sent To  
Notes
2014-04-21 06:18:41BUILDING PLAN REVIEW
 PERMIT: 14040145
 ADD: 701 S ROSEMARY AVE. # 128
 CONT: MASTER PLAN INC
 TEL: (561)683-9972
  
 2010 FLORIDA BUILDING CODE W
 * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION
 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013.
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: MON. APRIL 21/2014
 ACTION: DENIED
  
 1) PLANS DO NOT PROVIDE THE MINIMUM CRITERIA FOR PLAN
 REVIEW. 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010
 BUILDING PLAN REVIEW
 PERMIT: 14040145
  
 1) 1) PLANS DO NOT PROVIDE THE MINIMUM CRITERIA FOR
 PLAN REVIEW. 2010 WEST PALM BEACH AMENDMENTS TO THE
 FLORIDA BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010
 BUILDING PLAN REVIEW
 107.3.5 MINIMUM PLAN REVIEW CRITERIA FOR BUILDINGS.
 MINIMUM BUILDING TYPE
 OCCUPANCY TYPE/ ASSUMED MERCANTILE FOR THIS REVIEW
 SPRINKLERED/ NOT SPRINKLERED
 OCCUPANCY LOAD
 MEANS OF EGRESS
  
 2) ASSUMED THIS IS A MEERCANTILE OCCUPANCY WITH 30 SQ
 FT / OCCUPANT OVER 2100 SQ FT IN THE MERCANTILE AREA
 ALONE, OCCUPANT LOAD OVER 50 REQUIRING (2) EXITS,
 PLEASE PROVIDE COMPLIANCE WITH:
 2010 FBC-B 1014.2 EGRESS THROUGH INTERVENING SPACES.
 EGRESS THROUGH INTERVENING SPACES SHALL COMPLY WITH
 THIS SECTION.
 1. EGRESS FROM A ROOM OR SPACE SHALL NOT PASS THROUGH
 ADJOINING OR INTERVENING ROOMS OR AREAS, EXCEPT WHERE
 SUCH ADJOINING ROOMS OR AREAS AND THE AREA SERVED ARE
 ACCESSORY TO ONE OR THE OTHER, ARE NOT A GROUP H
 OCCUPANCY AND PROVIDE A DISCERNIBLE PATH OF EGRESS
 TRAVEL TO AN EXIT.
 EXCEPTION: MEANS OF EGRESS ARE NOT PROHIBITED THROUGH
 ADJOINING OR INTERVENING ROOMS OR SPACES IN A GROUP H,
 S OR F OCCUPANCY WHEN THE ADJOINING OR INTERVENING
 ROOMS OR SPACES ARE THE SAME OR A LESSER HAZARD
 OCCUPANCY GROUP.
  
 4. EGRESS SHALL NOT PASS THROUGH KITCHENS, STORAGE
 ROOMS, CLOSETS OR SPACES USED FOR SIMILAR PURPOSES.
 EXCEPTIONS:
 1. MEANS OF EGRESS ARE NOT PROHIBITED THROUGH A KITCHEN
 AREA SERVING ADJOINING ROOMS CONSTITUTING PART OF THE
 SAME DWELLING UNIT OR SLEEPING UNIT.
  
 2. MEANS OF EGRESS ARE NOT PROHIBITED THROUGH
 STOCKROOMS IN GROUP M OCCUPANCIES WHEN ALL OF THE
 FOLLOWING ARE MET:
  
 2.1. THE STOCK IS OF THE SAME HAZARD CLASSIFICATION AS
 THAT FOUND IN THE MAIN RETAIL AREA;
  
 2.2. NOT MORE THAN 50 PERCENT OF THE EXIT ACCESS IS
 THROUGH THE STOCKROOM;
  
 2.3. THE STOCKROOM IS NOT SUBJECT TO LOCKING FROM THE
 EGRESS SIDE; AND
  
 2.4. THERE IS A DEMARCATED, MINIMUM 44-INCH-WIDE (1118
 MM) AISLE DEFINED BY FULL- OR PARTIAL-HEIGHT FIXED
 WALLS OR SIMILAR CONSTRUCTION THAT WILL MAINTAIN THE
 REQUIRED WIDTH AND LEAD DIRECTLY FROM THE RETAIL AREA
 TO THE EXIT WITHOUT OBSTRUCTIONS.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2014-04-11 Cont ID  
Sent By wjolin Date 2014-04-11 Time 13:04 Rev Time 0.00
Received By wjolin Date 2014-04-11 Time 11:55 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2014-06-10 Cont ID  
Sent By jwitmer Date 2014-06-10 Time 16:08 Rev Time 0.00
Received By jwitmer Date 2014-05-22 Time 10:22 Sent To  
Notes
2014-05-23 10:22:585/23/2014 SENT TO ZONING FOR REVIEW. JW

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2014-06-10 Cont ID  
Sent By jwitmer Date 2014-06-10 Time 16:08 Rev Time 0.00
Received By jwitmer Date 2014-05-01 Time 14:55 Sent To Z
Notes
2014-05-01 14:57:30SENT TO ESCHNIDER, THEREAFTER, KINDLY FORWARD TO
 JWITMER.

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2014-04-21 Cont ID  
Sent By jwitmer Date 2014-04-21 Time 06:36 Rev Time 0.00
Received By jwitmer Date 2014-04-03 Time 10:40 Sent To  
Notes
2014-04-04 10:40:25SENT TO B7 SHELF FOR REVIEW. JG.

Review Stop P PLUMBING
Rev No 2 Status P Date 2014-06-10 Cont ID  
Sent By jwitmer Date 2014-06-10 Time 16:08 Rev Time 0.00
Received By jwitmer Date 2014-06-10 Time 16:08 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2014-04-21 Cont ID  
Sent By jwitmer Date 2014-04-21 Time 06:35 Rev Time 0.00
Received By jwitmer Date 2014-04-21 Time 06:19 Sent To  
Notes
2014-04-21 06:23:12PLUMBING PLAN REVIEW
 PERMIT: 14040145
 ADD: 701 S ROSEMARY AVE. # 128
 CONT: MASTER PLAN INC
 TEL: (561)683-9972
  
 2010 FLORIDA BUILDING CODE W
 * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION
 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013.
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: MON. APRIL 21/2014
 ACTION: DENIED
  
 1) THE PLANS DO NOT PROVIDE THE TENANTCY OCCUPANT LOAD
 OR OCCUPANCY. THE REQUIRED FIXTURE COUNT FOR PLUMBING
 FIXTURES IS NOT PROVIDED ON THE PLANS.
 PLANS DO NOT PROVIDE THE MINIMUM CRITERIA FOR PLAN
 REVIEW. 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010
 PLUMBING PLAN REVIEW
 107.3.5.1.3 MINIMUM PLAN REVIEW CRITERIA FOR PLUMBING.
 1. MINIMUM PLUMBING FACILITIES
 2. FIXTURE REQUIREMENTS
  
  
 2) THE PLANS INDICATE THE TOILET FACILITIES LOCATED
 WITHIN THE STCKROOM AREA. 2010 FBC-PLUMBING:
  
 403.3 REQUIRED PUBLIC TOILET FACILITIES.
 CUSTOMERS, PATRONS AND VISITORS SHALL BE PROVIDED WITH
 PUBLIC TOILET FACILITIES IN STRUCTURES AND TENANT
 SPACES INTENDED FOR PUBLIC UTILIZATION. THE NUMBER OF
 PLUMBING FIXTURES LOCATED WITHIN THE REQUIRED TOILET
 FACILITIES SHALL BE PROVIDED IN ACCORDANCE WITH SECTION
 403 FOR ALL USERS. EMPLOYEES SHALL BE PROVIDED WITH
 TOILET FACILITIES IN ALL OCCUPANCIES. EMPLOYEE TOILET
 FACILITIES SHALL BE EITHER SEPARATE OR COMBINED
 EMPLOYEE AND PUBLIC TOILET FACILITIES.
  
 403.3.1 ACCESS.
 THE ROUTE TO THE PUBLIC TOILET FACILITIES REQUIRED BY
 SECTION 403.3 SHALL NOT PASS THROUGH KITCHENS, STORAGE
 ROOMS OR CLOSETS. ACCESS TO THE REQUIRED FACILITIES
 SHALL BE FROM WITHIN THE BUILDING OR FROM THE EXTERIOR
 OF THE BUILDING. ALL ROUTES SHALL COMPLY WITH THE
 ACCESSIBILITY REQUIREMENTS OF THE FLORIDA BUILDING
 CODE, ACCESSIBILITY. THE PUBLIC SHALL HAVE ACCESS TO
 THE REQUIRED TOILET FACILITIES AT ALL TIMES THAT THE
 BUILDING IS OCCUPIED.
  
 3) THE PLANS INDICATE A 3 COMPARTMENT SINK AS WELL AS A
 SEPARATE HAND SINK. THESE ARE REQUIREMENTS FROM PUBLIC
 FOOD SERVICE ESTABLISHMENTS AND FOOD ESTABLISHMENTS, AS
 DEFINED IN CHAPTER 381 FLORIDA STATUTES, CHAPTER 500
 FLORIDA STATUTES AND CHAPTER 509 FLORIDA STATUTES,
 PLEASE PROVIDE ADDITIONAL INFORMATION AS TO THE USE OF
 THIS OCCUPANCY, A GREASE INTERCEPTOR MAY BE REQUIRED.
 107.2.1.3 ADDITIONAL INFORMATION IS REQUIED. FBC-P
 1003.3.1 GREASE INTERCEPTORS AND AUTOMATIC GREASE
 REMOVAL DEVICES REQUIRED.
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION &
 REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL
 LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH
 A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE
 SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE
 FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR
 YOUR ANTICIPATED COOPERATION.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]

Review Stop Z ZONING
Rev No 2 Status P Date 2014-05-14 Cont ID  
Sent By jwitmer Date 2014-06-10 Time 16:08 Rev Time 0.50
Received By eschneid Date 2014-05-14 Time 15:23 Sent To B
Notes
2014-05-12 17:21:415/12/14

Review Stop Z ZONING
Rev No 1 Status F Date 2014-04-17 Cont ID  
Sent By eschneid Date 2014-04-17 Time 11:53 Rev Time 1.00
Received By eschneid Date 2014-04-17 Time 11:53 Sent To  
Notes
2014-04-17 12:28:01FAILED
  
 PLEASE PROVIDE WRITTEN RESPONSES TO COMMENTS.
  
 1) ZONING STAFF IS UNABLE TO DETERMINE WHERE THE NEW
 STOREFRONT WILL BE LOCATED. PLEASE PROVIDE STAFF WITH
 INFORMATION TO PROVIDE A POINT OF REFERENCE TO REVIEW
 THE PERMIT. A SITE PLAN, PHOTO OR ELEVATIONS SHOWING
 MORE OF CITYPLACE WHICH HIGHLIGHT THE SPACE ARE
 ACCEPTABLE.
  
 2) SUITE 128 DOES NOT CURRENTLY EXIST WITHIN CITYPLACE
 AND THERE ARE NO VACANT SPACES IN THE VICINITY OF WHERE
 SUITE 128 WOULD GO. WHAT STORE(S) IS BEING REPLACED?
  
 3) SHEET A-1 INDICATES NEW WORK BY THE LANDLORD UNDER
 SEPARATE PERMIT YET SHEET A-2 IMPLIES THAT THE WORK
 (NEW SOFFIT, ETC.) WILL BE INCLUDED AS PART OF THIS
 PERMIT. PLEASE CLARIFY.
  
 4) THE PERMIT FOR THE LANDLORD WORK HAS NOT BEEN
 SUBMITTED. PLEASE PROVIDE MORE INFORMATION AS TO WHAT
 THE LANDLORD WORK WILL ENTAIL.
  
 CONTACT ERIC SCHNEIDER @ (561) 822-1446.
2014-04-14 11:38:234/14/14