Plan Review Details - Permit 14040120
Plan Review Stops For Permit 14040120
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2014-04-10 Cont ID  
Sent By jwitmer Date 2014-04-10 Time 14:34 Rev Time 0.00
Received By jwitmer Date 2014-04-10 Time 14:34 Sent To  
Notes
2014-04-10 14:40:50BUILDING PLAN REVIEW
 PERMIT: 14040120
 ADD: 2400 N FLAGLER DR
 CONT: BAYSHORE CONSTRUCTION
 TEL: (941)927-8565
  
 2010 FLORIDA BUILDING CODE W
 * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION
 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013.
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 2ND REVIEW
 DATE: THURSDAY APRIL 10/2014
 ACTION: APPROVED, SEE B. O. COMMENTS
 REPAIR/ REPLACEMENT
  
 PROVISO: SHOW COMPLIANCE WITH THE FOLLOWING SECTION,
 2010 FL ACCESSIBILITY CODE1005.2.1 HEIGHT.
 AT LEAST 25 PERCENT OF THE RAILINGS, GUARDS, OR
 HANDRAILS SHALL BE 34 INCHES (865 MM) MAXIMUM ABOVE THE
 GROUND OR DECK SURFACE.
 EXCEPTION: WHERE A GUARD COMPLYING WITH SECTIONS
 1003.2.12.1 AND 1003.2.12.2 OF THE INTERNATIONAL
 BUILDING CODE (2000 EDITION) OR SECTIONS 1012.2 AND
 1012.3 OF THE INTERNATIONAL BUILDING CODE (2003
 EDITION) (INCORPORATED BY REFERENCE, SEE ?REFERENCED
 STANDARDS? IN CHAPTER 1) IS PROVIDED, THE GUARD SHALL
 NOT BE REQUIRED TO COMPLY WITH 1005.2.1.
 1005.2.1.1 DISPERSION.
 RAILINGS, GUARDS, OR HANDRAILS REQUIRED TO COMPLY WITH
 1005.2.1 SHALL BE DISPERSED THROUGHOUT THE FISHING PIER
 OR PLATFORM.
 ADVISORY 1005.2.1.1 DISPERSION.
 PORTIONS OF THE RAILINGS THAT ARE LOWERED TO PROVIDE
 FISHING OPPORTUNITIES FOR PERSONS WITH DISABILITIES
 MUST BE LOCATED IN A VARIETY OF LOCATIONS ON THE
 FISHING PIER OR PLATFORM TO GIVE PEOPLE A VARIETY OF
 LOCATIONS TO FISH. DIFFERENT FISHING LOCATIONS MAY
 PROVIDE VARYING WATER DEPTHS, SHADE (AT CERTAIN TIMES
 OF THE DAY), VEGETATION, AND PROXIMITY TO THE SHORELINE
 OR BANK.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2014-04-09 Cont ID  
Sent By shill Date 2014-04-09 Time 19:40 Rev Time 0.00
Received By shill Date 2014-04-09 Time 19:40 Sent To  
Notes
2014-04-10 12:34:09ON 4/10/14, ROBERT BROWN ADDED:
 REVIEWED COST BREAKDOWN LINE ITEMS WITH DOUG MARTIN OF
 BAYSHORE CONSTRUCTION INC. THE MAJORTIY OF THE SCOPE OF
 WORK, INCLUDING DECK MATERIAL REPLACEMENT, GURADRAIL
 TOP AND BOTTOM RAIL REPLACEMENT, ETC. IS
 REPAIR/REPLACEMENT SCOPE THAT WOULD NOT REQUIRE THE
 SERVICES OF AN ARCHITECT OR ENGINEER. THE NEW DESIGN
 WORK IS LIMITED TO THE INSTALLATION OF THE FISHING
 STATION AND THE NEW BENCHES, AND THE COMBINED COST OF
 THAT WORK IS SIGNIFICANTLY LESS THAN THE $75,000 LIMIT
 FOR THE ARCITECTURE AND ENGINEERING EXEMPTIONS PER
 FLORIDA STATUTE.
 NO ARCHITECT OR ENGINEER PLANS ARE REQUIRED.
  
  
2014-04-09 19:43:09****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 1. SEE FBC 107.3.5 FOR MINIMUM PLAN REVIEW CRITERIA.
 THERE IS NO EXEMPTION TO ARCHITECTURE OR ENGINEERING
 FOR THIS SCOPE, SEE FLORIDA STATUTES 471 AND 481.
  
 PLAN REVIEW WILL BE COMPLETED AFTER PLANS ARE
 SUBMITTED.
  

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2014-04-09 Cont ID  
Sent By shill Date 2014-04-09 Time 19:43 Rev Time 0.00
Received By shill Date 2014-04-03 Time 10:58 Sent To  
Notes
2014-04-04 10:59:02SENT TO ZONING SHELF FOR REVIEW. JG.

Review Stop Z ZONING
Rev No 1 Status P Date 2014-04-07 Cont ID  
Sent By sgraham Date 2014-04-07 Time 12:05 Rev Time 0.00
Received By sgraham Date 2014-04-07 Time 12:05 Sent To B
Notes
***NONE***