| 2014-04-07 13:30:49 | RESIDENTIAL (R3) REROOF, BUILDING REVIEW COMMENTS. |
| | CODE; 2010 FBC. |
| | |
| | 1- PROVIDE SIGNED AND SEALED RAS 117 CALCULATIONS FOR |
| | NAIL ENHANCING AT PERIMETER AND CORNER AREAS AS |
| | REQUIRED BY LIMITATION #5.6 OF FLORIDA PRODUCT APPROVAL |
| | FL2948 SUBMITTED. SEC. R301.2.1.4.3 OF 2010 |
| | FBC-RESIDENTIAL. |
| | |
| | ***NOTE: THIS PROPERTY IS LOCATED IN EXPOSURE "D". |
| | DESIGN PROFESSIONAL TO TAKE THIS INTO CONSIDERATION |
| | WHEN DOING THE RAS 117 CALCULATIONS. |
| | |
| | 2- THE SELECTED ASSEMBLY "W-1" DOESN'T MEET THE DESIGN |
| | PRESSURES OF SEC. R301.2.1.4.3 FOR ROOF ZONE #1. NEED |
| | TO SELECT ANOTHER ASSEMBLY AS REQUIRED BY LIMITATION |
| | #5.6 OF FLORIDA PRODUCT APPROVAL SUBMITTED. DESIGN |
| | PROFESSIONAL DOING THE RAS 117 CALCULATIONS TO |
| | COORDINATE THE CALCULATIONS WITH NEW SELECTED ASSEMBLY. |
| | |
| | 3- NEED TO PROVIDE THE LATEST REVISION OF FLORIDA |
| | PRODUCT APPROVAL FL2948. THE CURRENT FLORIDA PRODUCT |
| | APPROVAL IS FL2948-R8 NOT FL2948-R7. RESUBMIT CURRENT |
| | NOA AS REQUIRED BY DCA RULE 9N-3. ***NOTE: DESIGN |
| | PROFESSIONAL DOING THE RAS 117 CALCULATIONS TO |
| | COORDINATE WITH NEW FLORIDA PRODUCT APPROVAL. |
| | |
| | 4- PROVIDE 2 COPIES OF THE CURRENT FLORIDA PRODUCT |
| | APPROVAL. ONLY ONE COPY WAS SUBMITTED AT THIS TIME. |
| | SEC. 107.1 CITY AMENDMENTS TO FBC |
| | |
| | 5- PROVIDE TOTAL SQUARE FOOTAGE OF FLAT ROOF TO BE |
| | INSTALLED TO VERIFY COMPLIANCE WITH THE VALUATION OF |
| | THE PROJECT. SEC. 109.3 CITY AMENDMENTS TO FBC. |
| | |
| | 6- THE VALUE OF THE HOUSE IS OVER $300,000. NEED TO |
| | PROVIDE COMPLIANCE WITH THE ROOF TO WALL CONNECTIONS AS |
| | REQUIRED BY SEC. 611.8 OF 2010 FBC-EXISTING BUILDING. |
| | |
| | IF YOU HAVE ANY QUESTIONS, PLEASE CALL |
| | JULIO GOMEZ |
| | COMMERCIAL COMBINATION PLANS EXAMINER |
| | (561)805-6712 |