Plan Review Details - Permit 14031111
| Plan Review Stops For Permit 14031111 |
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2014-04-25 |
|
|
Cont ID |
|
| Sent By |
dhayes |
Date |
2014-04-25 |
Time |
08:51 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
2014-04-25 |
Time |
08:51 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2014-04-16 |
|
|
Cont ID |
|
| Sent By |
dhayes |
Date |
2014-04-16 |
Time |
08:50 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
2014-04-16 |
Time |
08:34 |
Sent To |
|
|
| Notes |
| 2014-04-16 08:50:09 | 907.1.2 FIRE ALARM SHOP DRAWINGS. [F] | | | | | | SHOP DRAWINGS FOR FIRE ALARM SYSTEMS SHALL BE SUBMITTED | | | FOR REVIEW AND APPROVAL PRIOR TO SYSTEM INSTALLATION, | | | AND SHALL INCLUDE, BUT NOT BE LIMITED TO, ALL OF THE | | | FOLLOWING: | | | 1. A FLOOR PLAN THAT INDICATES THE USE OF ALL ROOMS. | | | 2. LOCATIONS OF ALARM-INITIATING DEVICES. | | | 3. LOCATIONS OF ALARM NOTIFICATION APPLIANCES, | | | INCLUDING CANDELA RATINGS FOR VISIBLE ALARM | | | NOTIFICATION APPLIANCES. | | | 4. LOCATION OF FIRE ALARM CONTROL UNIT, TRANSPONDERS | | | AND NOTIFICATION POWER SUPPLIES. | | | 5. ANNUNCIATORS. | | | 6. POWER CONNECTION. | | | 7. BATTERY CALCULATIONS. | | | 8. CONDUCTOR TYPE AND SIZES. | | | 9. VOLTAGE DROP CALCULATIONS. | | | 10. MANUFACTURERS' DATA SHEETS INDICATING MODEL NUMBERS | | | AND LISTING INFORMATION FOR EQUIPMENT, DEVICES AND | | | MATERIALS. | | | 11. DETAILS OF CEILING HEIGHT AND CONSTRUCTION. | | | 12. THE INTERFACE OF FIRE SAFETY CONTROL FUNCTIONS. | | | 13. CLASSIFICATION OF THE SUPERVISING STATION. | | | | | | DAVID A. HAYES, ELECTRICAL PLANS EXAMINER. | | | [email protected] 561-508-6717 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2014-03-31 |
|
|
Cont ID |
|
| Sent By |
scaldero |
Date |
2014-03-31 |
Time |
12:54 |
Rev Time |
0.00 |
| Received By |
scaldero |
Date |
2014-03-31 |
Time |
12:54 |
Sent To |
E |
|
| Notes |
| 2014-03-31 12:55:05 | PERMIT # 14031111 | | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | | | PROVISO: | | | ADDITIONAL DEVICE(S) NEEDED FOR PROPER COVERAGE. | | | | | | | | | SUE ELLEN CALDERON | | | FIRE INSPECTOR & INVESTIGATOR | | | OFFICE OF THE FIRE MARSHAL | | | WEST PALM BEACH FIRE RESCUE | | | [email protected] | | | (561) 804-4751 | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2014-04-25 |
|
|
Cont ID |
|
| Sent By |
dhayes |
Date |
2014-04-25 |
Time |
08:52 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
2014-04-24 |
Time |
17:33 |
Sent To |
|
|
| Notes |
| 2014-04-24 17:34:06 | SENT TO D HAYES |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2014-04-16 |
|
|
Cont ID |
|
| Sent By |
dhayes |
Date |
2014-04-16 |
Time |
08:50 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
2014-03-31 |
Time |
11:16 |
Sent To |
|
|
| Notes |
| 2014-03-31 11:16:57 | ROUTED FIRE |
|
|
|