Plan Review Details - Permit 14030852
Plan Review Stops For Permit 14030852
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2014-03-26 Cont ID  
Sent By shill Date 2014-03-26 Time 13:21 Rev Time 0.00
Received By shill Date 2014-03-26 Time 13:21 Sent To  
Notes
2014-03-26 13:22:27****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 1. REVISE FLOOR PLAN TO PROVIDE THE FOLLOWING
 INFORMATION FOR BEDROOMS; FBC R310, FBC EB 604.1. THE
 CLEAR OPENING CANNOT BE REDUCED BY MORE THAN 5%:
  
 REVISE PLAN TO STATE WHAT TYPE OF WINDOW IS THERE NOW
 IN THE BEDROOMS - AWNING, CASEMENT, SINGLE HUNG?
  
 REVISE PLAN TO STATE WHAT THE EXISTING CLEAR OPENING
 DIMENSIONS ARE. CLEAR OPENING IS THE OPENING WHICH
 EXISTS WHEN THE WINDOW IS FULLY OPEN.
  
 REVISE PLAN TO STATE WHAT THE PROPOSED CLEAR OPENING
 DIMENSIONS ARE. THIS CAN BE OBTAINED FROM THE
 MANUFACTURER.
  
 2. . IMPACT PROTECTION REQUIRED,FBC1609.1.4, FBC R
 301.2.1.2. PROVIDE PRODUCT APPROVALS AND, IF SHUTTERS
 ARE USED, COMPLETE THE SAMPLE INSTALLATION SCHEDULE
 (AVAILABLE IN THE LOBBY AND AT HTTP://WWW.CITYOFWPB.COM
 /CONSTRUCTION/PDF/SCHEDULE_FOR_INSTALLATION.PDF)
  
 IF THIS FALLS UNDER THE 25% EXCEPTION FBC EB 606.4,
 PROVIDE CALCULATIONS.
  
  

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2014-03-26 Cont ID  
Sent By shill Date 2014-03-26 Time 13:22 Rev Time 0.00
Received By shill Date 2014-03-20 Time 13:02 Sent To  
Notes
2014-03-20 13:03:13ROUTED TO BLDG LESS THAN 5000