Plan Review Details - Permit 14030725
Plan Review Stops For Permit 14030725
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2014-05-06 Cont ID  
Sent By rmcdouga Date 2014-05-06 Time 18:50 Rev Time 0.00
Received By skennedy Date 2014-05-15 Time 14:42 Sent To  
Notes
2014-05-06 18:53:11CONTRACTOR CAME IN AND SIGNED THE ENERGY FORMS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2014-04-28 Cont ID  
Sent By rmcdouga Date 2014-04-28 Time 17:39 Rev Time 0.00
Received By rmcdouga Date 2014-04-28 Time 17:38 Sent To E
Notes
2014-04-28 17:41:462010 FBC
  
 DENIED BY BUILDING
  
 1) THE OWNER/AGENT IS REQUIRED TO SIGN THE ENERGY
 CALCULATIONS. FORM 405-10 HAS NOT BEEN SIGNED BY THE
 OWNER/AGENT.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2014-03-24 Cont ID  
Sent By rmcdouga Date 2014-03-24 Time 18:19 Rev Time 0.00
Received By rmcdouga Date 2014-03-24 Time 06:42 Sent To  
Notes
2014-03-22 10:00:122010 FBC
  
 ACCORDING TO CITY RECORDS, THIS BUILDING WAS
 CONSTRUCTED IN 1926 AS A GARAGE/APARTMENT. THESE PLANS
 HAVE NOT BEEN REVIEWED BY ZONING AT THE TIME OF THIS
 REVIEW. IT APPEARS THAT THE GARAGE PORTION OF THIS
 BUILDING MAY HAVE BEEN ILLEGALLY CONVERTED TO LIVING
 SPACE WITHOUT THE PROPER PERMITS OR INSPECTIONS. NOTE:
 ZONING MAY NOT ALLOW THIS STRUCTURE TO HAVE A KITCHEN
 OR BE USED AS A RENTAL UNIT. SEE ZONING REVIEW
 COMMENTS.
  
 DENIED BY BUILDING
  
 1) THE OWNER/AGENT IS REQUIRED TO SIGN THE ENERGY
 CALCULATIONS.
  
 2) THE ENERGY CALCULATIONS SPECIFY THAT THE ENTIRE 669
 SQFT STRUCTURE IS A CRAWL SPACE WITH R-19 INSULATION.
 ONE OF THE WALL SECTIONS ON SHEET 2 SHOWS A CRAWL SPACE
 AND THE OTHER SHOWS A SLAB. PLEASE CLARIFY.
  
 3) SPECIFY THE LOCATION OF THE GAS WATER HEATER ON THE
 PLANS.
  
 4) SHOW COMPLIANCE WITH FBC R314 AND R315 FOR SMOKE AND
 CARBON MONOXIDE ALARMS.
  
 5) SHOW COMPLIANCE WITH FBC R310 FOR EMERGENCY ESCAPE
 AND RESCUE OPENINGS AT SLEEPING ROOMS.
  
 6) THE NEW WINDOWS ARE TAGGED "A" ON THE THE ELEVATIONS
 ON SHEET 1 AND "B" ON THE FLOOR PLANS ON SHEETS 2 AND
 3. PLEASE CLARIFY.
  
 7) THE WINDOW SCHEDULE ON SHEET 1, SPECIFIES 37" X 37"
 WINDOWS FOR "A". THE ELEVATIONS APPEAR TO SHOW LARGER
 HEIGHT WINDOWS. PLEASE CLARIFY.
  
 8) THE WORK IS SPECIFIED AS A LEVEL 2 ALTERATION ON THE
 PLANS. SINCE THE WORK AREA EXCEEDS 50 PERCENT OF THE
 AREA OF THE BUILDING IT SHOULD BE CLASSIFIED AS A LEVEL
 3 ALTERATION AND A CHANGE OF OCCUPANCY ( CONVERTING THE
 GARAGE TO LIVING AREA ). FBC EXISTING BUILDING SECTIONS
 405 AND 406
  
 9) THE PRODUCT APPROVALS FOR THE NEW WINDOWS ARE NOT
 RATED FOR LARGE MISSILE IMPACT WHICH IS REQUIRED BY FBC
 R301.2.1.2. SUBMIT TWO COPIES OF PRODUCT APPROVALS AS
 REQUIRED BY DCA RULE 9N-3 THAT HAVE BEEN REVIEWED AND
 APPROVED BY THE DESIGNER OF RECORD.
  
 10) SUBMIT TWO SETS OF PRODUCT APPROVALS FOR THE TRUSS
 ANCHORS AND STRAPS SPECIFIED ON THE PLANS. DCA RULE
 9N-3
  
 11) THE CITY DOES NOT HAVE A PERMIT RECORD THAT SHOWS
 THAT THE DOORS AND WINDOWS IN THIS BUILDING WERE
 REPLACED. IF THE DOORS AND WINDOWS THAT ARE SPECIFIED
 AS EXISTING WERE INSTALLED RECENTLY WITHOUT PERMITS OR
 INSPECTIONS, SUBMIT TWO SETS OF PRODUCT APPROVALS FOR
 THEM AND THE REQUIRED IMPACT PROTECTION DEVICES. DCA
 RULE 9N-3
  
  
 12) IN ORDER TO SPEED THE REVIEW TIME OF YOUR
 RE-SUBMITTAL, PLEASE SUBMIT A RESPONSE LETTER
 INDICATING HOW THE REVIEW COMMENTS HAVE BEEN ADDRESSED.
  
  
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2014-05-06 Cont ID  
Sent By rlecky Date 2014-05-06 Time 11:50 Rev Time 0.00
Received By rlecky Date 2014-05-06 Time 10:34 Sent To  
Notes
2014-05-06 11:32:15PLANS SHOW THE SERVICE FOR THE MAIN HOUSE TO BE LOCATED
 ON THE GUEST HOUSE WITH THE GUEST HOUSE SERVICE. MAIN
 DISCONNECTS FOR EACH BUILDING ARE REQUIRED AT THAT
 LOCATION AND ARE NOTED ON THE PLAN. NEC 230.70; 230.2

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2014-03-25 Cont ID  
Sent By dharvey Date 2014-03-25 Time 08:57 Rev Time 0.00
Received By dharvey Date 2014-03-25 Time 08:57 Sent To  
Notes
2014-03-25 08:57:45PROVIDE LOAD CALCULATION IN COMPLIANCE WITH NEC 220 -
 NUMEROUS SECTIONS
 AIR CONDITIONING LOAD APPEARS TO EXCEED HEAT LOAD AND
 MUST BE USED
 GENERAL LIGHTING LOAD TO SHOW FLOOR AREA USED FOR THE
 CALCULATION 220.12
 OTHER LOADS TO BE SHOWN AND CALCULATED AS PER 220.14
 SERVICE APPEARS TO BE INDICATED AS NEW, SHOW LOCATIONS
 OF ALL EQUIPMENT ON BUILDINGS
 OTHER NOTE INDICATES EXISTING AND ADDITION, SHOW LOAD
 CALCULATION PER 220.16
 GROUNDING ELECTRODE SYSTEM(S) REQUIRED PER 250.50
 SHOW CONNECTION TO EACH ELECTRODE PRESENT PER 250.52
 SHOW LOCATION OF HANDHOLE OR RISER FOR FPL CONNECTION
 THHN INSULATION IS NOT FOR WET LOCATION USE 310.13
 PROVIDE DETAILS OF METERMAIN COMBINATION, INCLUDING AIC
 RATINGS 110.9
 LEVEL OF ALTERATION PER FBC-EB VOLUME IS CALLED OUT AS
 LEVEL 2
 SMOKE ALARMS TO BE INDICATED ON DRAWINGS
 FOR ALL NEW WORK OR THOSE AREAS IN THE WORK AREA:
 GFCI REQUIRED PER 210.8
 ARC FAULT REQUIRED PER 210.12
 PROVIDE LOAD BALANCING PER 210.11
 CORRECTIONS ARE REQUIRED PRIOR TO CONTINUING REVIEW
  

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2014-03-27 Cont ID  
Sent By fmittner Date 2014-03-27 Time 15:00 Rev Time 0.00
Received By fmittner Date 2014-03-27 Time 15:00 Sent To  
Notes
2014-03-27 15:01:11WINDOW FRAMES MUST BE WHITE, CLEAR GLASS.

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2014-05-15 Cont ID  
Sent By skennedy Date 2014-05-15 Time 14:42 Rev Time 0.00
Received By skennedy Date 2014-05-15 Time 14:36 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2014-05-06 Cont ID  
Sent By rlecky Date 2014-05-06 Time 11:50 Rev Time 0.00
Received By rlecky Date 2014-04-21 Time 16:56 Sent To  
Notes
2014-04-21 16:57:14RESUBMITTAL SENT TO R. MCDOUGAL'S DESK FOR REVIEW. JG.

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2014-04-02 Cont ID  
Sent By rmcdouga Date 2014-04-02 Time 13:16 Rev Time 0.00
Received By rmcdouga Date 2014-03-18 Time 11:18 Sent To  
Notes
2014-03-19 11:18:37SENT TO R1 SHELF FOR REVIEW. JG.

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 4 Status P Date 2014-05-19 Cont ID  
Sent By rmcdouga Date 2014-05-19 Time 16:45 Rev Time 0.00
Received By rmcdouga Date 2014-05-19 Time 16:45 Sent To  
Notes
2014-05-19 16:47:00NO FEES WERE DUE.

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 3 Status P Date 2014-05-15 Cont ID  
Sent By skennedy Date 2014-05-15 Time 14:42 Rev Time 0.00
Received By skennedy Date 2014-05-15 Time 14:42 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status F Date 2014-04-28 Cont ID  
Sent By rmcdouga Date 2014-04-28 Time 17:53 Rev Time 0.00
Received By rmcdouga Date 2014-04-28 Time 17:53 Sent To  
Notes
2014-04-28 17:58:45AN IMPACT FEE REVIEW BY PALM BEACH COUNTY WILL BE
 REQUIRED. AFTER THE PLANS HAVE BEEN APPROVED, ONE SET
 OF THE PLANS CAN BE SIGNED OUT AND TAKEN TO PALM BEACH
 COUNTY FOR IMPACT REVIEW. THE STAMPED PLANS AND A COPY
 OF THE IMPACT FEE RECEIPT CAN THEN BE RETURNED AND THE
 PERMIT CAN BE ISSUED. THE GARAGE PORTION OF THE GARAGE
 APARTMENT THAT WAS CONVERTED TO LIVING SPACE WILL NEED
 TO BE EVALUATED BY PALM BEACH COUNTY TO DETERMINE IF
 ANY IMPACT FEES ARE DUE.

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2014-03-22 Cont ID  
Sent By rmcdouga Date 2014-03-22 Time 10:28 Rev Time 0.00
Received By rmcdouga Date 2014-03-22 Time 10:28 Sent To  
Notes
2014-03-22 10:32:58AN IMPACT FEE REVIEW BY PALM BEACH COUNTY WILL BE
 REQUIRED. AFTER THE PLANS HAVE BEEN APPROVED, ONE SET
 OF THE PLANS CAN BE SIGNED OUT AND TAKEN TO PALM BEACH
 COUNTY FOR IMPACT REVIEW. THE STAMPED PLANS AND A COPY
 OF THE IMPACT FEE RECEIPT CAN THEN BE RETURNED AND THE
 PERMIT CAN BE ISSUED.

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2014-05-12 Cont ID  
Sent By rmcdouga Date 2014-05-12 Time 13:57 Rev Time 0.00
Received By rmcdouga Date 2014-05-12 Time 13:57 Sent To  
Notes
2014-05-12 14:00:49EQUIPMENT SIZING CALCULATION SUMMARY WAS SUBMITTED. THE
 STRUCTURE IS HISTORIC AND IS EXEMPT FROM ENERGY CODE.

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2014-04-28 Cont ID  
Sent By rmcdouga Date 2014-04-28 Time 17:42 Rev Time 0.00
Received By rmcdouga Date 2014-04-28 Time 17:42 Sent To  
Notes
2014-04-28 17:47:012010 FBC
  
 DENIED BY MECHANICAL
  
 1) SUBMIT TWO SETS OF EQUIPMENT SIZING CALCULATIONS
 (MANUAL J CALCULATIONS) AS REQUIRED BY FBCR M1401.3.
 NOTE: THE EQUIPMENT SCHEDULE ON THE MECHANICAL PLANS
 MUST MATCH THE CALCULATIONS.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2014-03-22 Cont ID  
Sent By rmcdouga Date 2014-03-22 Time 10:33 Rev Time 0.00
Received By rmcdouga Date 2014-03-22 Time 10:33 Sent To  
Notes
2014-03-22 11:28:172010 FBC
  
 DENIED BY MECHANICAL
  
 1) SUBMIT TWO SETS OF EQUIPMENT SIZING CALCULATIONS AS
 REQUIRED BY FBCR M1401.3. NOTE: THE EQUIPMENT SCHEDULE
 ON THE MECHANICAL PLANS MUST MATCH THE CALCULATIONS.
  
 2) THE PLANS SHOW DUCT WORK IN THE CEILING. BASED ON
 THE WALL SECTION ON SHEET 2, THIS STRUCTURE HAS A FLAT
 ROOF AND A SINGLE ASSEMBLY ROOF/CEILING AND THE CEILING
 HEIGHT IS SPECIFIED AS 8' 1" ON THE PLANS. THE DUCT
 WORK WILL NEED TO BE INSTALLED IN A CHASE. PLEASE
 CLARIFY.
  
 3) THE PLANS SPECIFY THE AIR HANDLER LOCATED IN A
 CLOSET ABOVE A STACKABLE WASHER/DRYER. THERE WILL NOT
 BE ENOUGH ROOM TO INSTALL THE A/H AND HAVE IT
 ACCESSIBLE FOR SERVICING. FBCR M1401.2 PLEASE CORRECT.
  
 4) SPECIFY THE SIZE OF THE SUPPLY DUCT FOR THE
 BATHROOM. NOTE: THE TRANSFER DUCT IS TO BE 1.5 TIMES
 THE CROSS SECTIONAL AREA OF ALL THE DUCTS ENTERING THE
 MASTER SUIT. FBC M1602.4
  
 5) SPECIFY THE LOCATION AND VENTING OF THE GAS WATER
 HEATER. FBCR M1801
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop P PLUMBING
Rev No 2 Status P Date 2014-04-28 Cont ID  
Sent By rmcdouga Date 2014-04-28 Time 17:43 Rev Time 0.00
Received By rmcdouga Date 2014-04-28 Time 17:43 Sent To  
Notes
2014-04-28 17:44:14REDLINED PLANS. CHANGED FROM LAV TO SINK AND ADDED TRAP
 FOR TWO COMPARTMENT SINK AT KITCHEN. CHANGED FROM LAV
 TO CLOTHES WASHER STANDPIPE.
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
2014-04-21 16:55:28NEW SHEETS SUBMITTED. JG.

Review Stop P PLUMBING
Rev No 1 Status P Date 2014-03-22 Cont ID  
Sent By rmcdouga Date 2014-03-22 Time 10:21 Rev Time 0.00
Received By rmcdouga Date 2014-03-22 Time 10:21 Sent To  
Notes
2014-03-22 10:28:00REDLINED PLANS. CHANGED FROM LAV TO SINK AND ADDED TRAP
 FOR TWO COMPARTMENT SINK AT KITCHEN. CHANGED FROM LAV
 TO CLOTHES WASHER STANDPIPE.

Review Stop Z ZONING
Rev No 1 Status P Date 2014-03-27 Cont ID  
Sent By fmittner Date 2014-03-27 Time 15:00 Rev Time 0.00
Received By fmittner Date 2014-03-27 Time 15:00 Sent To  
Notes
2014-03-20 16:01:353/20/14