| Plan Review Stops For Permit 14030725 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2014-05-06 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-05-06 |
Time |
18:50 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2014-05-15 |
Time |
14:42 |
Sent To |
|
|
| Notes |
| 2014-05-06 18:53:11 | CONTRACTOR CAME IN AND SIGNED THE ENERGY FORMS. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2014-04-28 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-04-28 |
Time |
17:39 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2014-04-28 |
Time |
17:38 |
Sent To |
E |
|
| Notes |
| 2014-04-28 17:41:46 | 2010 FBC | | | | | | DENIED BY BUILDING | | | | | | 1) THE OWNER/AGENT IS REQUIRED TO SIGN THE ENERGY | | | CALCULATIONS. FORM 405-10 HAS NOT BEEN SIGNED BY THE | | | OWNER/AGENT. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2014-03-24 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-03-24 |
Time |
18:19 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2014-03-24 |
Time |
06:42 |
Sent To |
|
|
| Notes |
| 2014-03-22 10:00:12 | 2010 FBC | | | | | | ACCORDING TO CITY RECORDS, THIS BUILDING WAS | | | CONSTRUCTED IN 1926 AS A GARAGE/APARTMENT. THESE PLANS | | | HAVE NOT BEEN REVIEWED BY ZONING AT THE TIME OF THIS | | | REVIEW. IT APPEARS THAT THE GARAGE PORTION OF THIS | | | BUILDING MAY HAVE BEEN ILLEGALLY CONVERTED TO LIVING | | | SPACE WITHOUT THE PROPER PERMITS OR INSPECTIONS. NOTE: | | | ZONING MAY NOT ALLOW THIS STRUCTURE TO HAVE A KITCHEN | | | OR BE USED AS A RENTAL UNIT. SEE ZONING REVIEW | | | COMMENTS. | | | | | | DENIED BY BUILDING | | | | | | 1) THE OWNER/AGENT IS REQUIRED TO SIGN THE ENERGY | | | CALCULATIONS. | | | | | | 2) THE ENERGY CALCULATIONS SPECIFY THAT THE ENTIRE 669 | | | SQFT STRUCTURE IS A CRAWL SPACE WITH R-19 INSULATION. | | | ONE OF THE WALL SECTIONS ON SHEET 2 SHOWS A CRAWL SPACE | | | AND THE OTHER SHOWS A SLAB. PLEASE CLARIFY. | | | | | | 3) SPECIFY THE LOCATION OF THE GAS WATER HEATER ON THE | | | PLANS. | | | | | | 4) SHOW COMPLIANCE WITH FBC R314 AND R315 FOR SMOKE AND | | | CARBON MONOXIDE ALARMS. | | | | | | 5) SHOW COMPLIANCE WITH FBC R310 FOR EMERGENCY ESCAPE | | | AND RESCUE OPENINGS AT SLEEPING ROOMS. | | | | | | 6) THE NEW WINDOWS ARE TAGGED "A" ON THE THE ELEVATIONS | | | ON SHEET 1 AND "B" ON THE FLOOR PLANS ON SHEETS 2 AND | | | 3. PLEASE CLARIFY. | | | | | | 7) THE WINDOW SCHEDULE ON SHEET 1, SPECIFIES 37" X 37" | | | WINDOWS FOR "A". THE ELEVATIONS APPEAR TO SHOW LARGER | | | HEIGHT WINDOWS. PLEASE CLARIFY. | | | | | | 8) THE WORK IS SPECIFIED AS A LEVEL 2 ALTERATION ON THE | | | PLANS. SINCE THE WORK AREA EXCEEDS 50 PERCENT OF THE | | | AREA OF THE BUILDING IT SHOULD BE CLASSIFIED AS A LEVEL | | | 3 ALTERATION AND A CHANGE OF OCCUPANCY ( CONVERTING THE | | | GARAGE TO LIVING AREA ). FBC EXISTING BUILDING SECTIONS | | | 405 AND 406 | | | | | | 9) THE PRODUCT APPROVALS FOR THE NEW WINDOWS ARE NOT | | | RATED FOR LARGE MISSILE IMPACT WHICH IS REQUIRED BY FBC | | | R301.2.1.2. SUBMIT TWO COPIES OF PRODUCT APPROVALS AS | | | REQUIRED BY DCA RULE 9N-3 THAT HAVE BEEN REVIEWED AND | | | APPROVED BY THE DESIGNER OF RECORD. | | | | | | 10) SUBMIT TWO SETS OF PRODUCT APPROVALS FOR THE TRUSS | | | ANCHORS AND STRAPS SPECIFIED ON THE PLANS. DCA RULE | | | 9N-3 | | | | | | 11) THE CITY DOES NOT HAVE A PERMIT RECORD THAT SHOWS | | | THAT THE DOORS AND WINDOWS IN THIS BUILDING WERE | | | REPLACED. IF THE DOORS AND WINDOWS THAT ARE SPECIFIED | | | AS EXISTING WERE INSTALLED RECENTLY WITHOUT PERMITS OR | | | INSPECTIONS, SUBMIT TWO SETS OF PRODUCT APPROVALS FOR | | | THEM AND THE REQUIRED IMPACT PROTECTION DEVICES. DCA | | | RULE 9N-3 | | | | | | | | | 12) IN ORDER TO SPEED THE REVIEW TIME OF YOUR | | | RE-SUBMITTAL, PLEASE SUBMIT A RESPONSE LETTER | | | INDICATING HOW THE REVIEW COMMENTS HAVE BEEN ADDRESSED. | | | | | | | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2014-05-06 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2014-05-06 |
Time |
11:50 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2014-05-06 |
Time |
10:34 |
Sent To |
|
|
| Notes |
| 2014-05-06 11:32:15 | PLANS SHOW THE SERVICE FOR THE MAIN HOUSE TO BE LOCATED | | | ON THE GUEST HOUSE WITH THE GUEST HOUSE SERVICE. MAIN | | | DISCONNECTS FOR EACH BUILDING ARE REQUIRED AT THAT | | | LOCATION AND ARE NOTED ON THE PLAN. NEC 230.70; 230.2 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2014-03-25 |
|
|
Cont ID |
|
| Sent By |
dharvey |
Date |
2014-03-25 |
Time |
08:57 |
Rev Time |
0.00 |
| Received By |
dharvey |
Date |
2014-03-25 |
Time |
08:57 |
Sent To |
|
|
| Notes |
| 2014-03-25 08:57:45 | PROVIDE LOAD CALCULATION IN COMPLIANCE WITH NEC 220 - | | | NUMEROUS SECTIONS | | | AIR CONDITIONING LOAD APPEARS TO EXCEED HEAT LOAD AND | | | MUST BE USED | | | GENERAL LIGHTING LOAD TO SHOW FLOOR AREA USED FOR THE | | | CALCULATION 220.12 | | | OTHER LOADS TO BE SHOWN AND CALCULATED AS PER 220.14 | | | SERVICE APPEARS TO BE INDICATED AS NEW, SHOW LOCATIONS | | | OF ALL EQUIPMENT ON BUILDINGS | | | OTHER NOTE INDICATES EXISTING AND ADDITION, SHOW LOAD | | | CALCULATION PER 220.16 | | | GROUNDING ELECTRODE SYSTEM(S) REQUIRED PER 250.50 | | | SHOW CONNECTION TO EACH ELECTRODE PRESENT PER 250.52 | | | SHOW LOCATION OF HANDHOLE OR RISER FOR FPL CONNECTION | | | THHN INSULATION IS NOT FOR WET LOCATION USE 310.13 | | | PROVIDE DETAILS OF METERMAIN COMBINATION, INCLUDING AIC | | | RATINGS 110.9 | | | LEVEL OF ALTERATION PER FBC-EB VOLUME IS CALLED OUT AS | | | LEVEL 2 | | | SMOKE ALARMS TO BE INDICATED ON DRAWINGS | | | FOR ALL NEW WORK OR THOSE AREAS IN THE WORK AREA: | | | GFCI REQUIRED PER 210.8 | | | ARC FAULT REQUIRED PER 210.12 | | | PROVIDE LOAD BALANCING PER 210.11 | | | CORRECTIONS ARE REQUIRED PRIOR TO CONTINUING REVIEW | | | |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
P |
Date |
2014-03-27 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2014-03-27 |
Time |
15:00 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2014-03-27 |
Time |
15:00 |
Sent To |
|
|
| Notes |
| 2014-03-27 15:01:11 | WINDOW FRAMES MUST BE WHITE, CLEAR GLASS. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2014-05-15 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2014-05-15 |
Time |
14:42 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2014-05-15 |
Time |
14:36 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2014-05-06 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2014-05-06 |
Time |
11:50 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2014-04-21 |
Time |
16:56 |
Sent To |
|
|
| Notes |
| 2014-04-21 16:57:14 | RESUBMITTAL SENT TO R. MCDOUGAL'S DESK FOR REVIEW. JG. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2014-04-02 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-04-02 |
Time |
13:16 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2014-03-18 |
Time |
11:18 |
Sent To |
|
|
| Notes |
| 2014-03-19 11:18:37 | SENT TO R1 SHELF FOR REVIEW. JG. |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
4 |
Status |
P |
Date |
2014-05-19 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-05-19 |
Time |
16:45 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2014-05-19 |
Time |
16:45 |
Sent To |
|
|
| Notes |
| 2014-05-19 16:47:00 | NO FEES WERE DUE. |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
3 |
Status |
P |
Date |
2014-05-15 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2014-05-15 |
Time |
14:42 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2014-05-15 |
Time |
14:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
F |
Date |
2014-04-28 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-04-28 |
Time |
17:53 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2014-04-28 |
Time |
17:53 |
Sent To |
|
|
| Notes |
| 2014-04-28 17:58:45 | AN IMPACT FEE REVIEW BY PALM BEACH COUNTY WILL BE | | | REQUIRED. AFTER THE PLANS HAVE BEEN APPROVED, ONE SET | | | OF THE PLANS CAN BE SIGNED OUT AND TAKEN TO PALM BEACH | | | COUNTY FOR IMPACT REVIEW. THE STAMPED PLANS AND A COPY | | | OF THE IMPACT FEE RECEIPT CAN THEN BE RETURNED AND THE | | | PERMIT CAN BE ISSUED. THE GARAGE PORTION OF THE GARAGE | | | APARTMENT THAT WAS CONVERTED TO LIVING SPACE WILL NEED | | | TO BE EVALUATED BY PALM BEACH COUNTY TO DETERMINE IF | | | ANY IMPACT FEES ARE DUE. |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2014-03-22 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-03-22 |
Time |
10:28 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2014-03-22 |
Time |
10:28 |
Sent To |
|
|
| Notes |
| 2014-03-22 10:32:58 | AN IMPACT FEE REVIEW BY PALM BEACH COUNTY WILL BE | | | REQUIRED. AFTER THE PLANS HAVE BEEN APPROVED, ONE SET | | | OF THE PLANS CAN BE SIGNED OUT AND TAKEN TO PALM BEACH | | | COUNTY FOR IMPACT REVIEW. THE STAMPED PLANS AND A COPY | | | OF THE IMPACT FEE RECEIPT CAN THEN BE RETURNED AND THE | | | PERMIT CAN BE ISSUED. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2014-05-12 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-05-12 |
Time |
13:57 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2014-05-12 |
Time |
13:57 |
Sent To |
|
|
| Notes |
| 2014-05-12 14:00:49 | EQUIPMENT SIZING CALCULATION SUMMARY WAS SUBMITTED. THE | | | STRUCTURE IS HISTORIC AND IS EXEMPT FROM ENERGY CODE. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2014-04-28 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-04-28 |
Time |
17:42 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2014-04-28 |
Time |
17:42 |
Sent To |
|
|
| Notes |
| 2014-04-28 17:47:01 | 2010 FBC | | | | | | DENIED BY MECHANICAL | | | | | | 1) SUBMIT TWO SETS OF EQUIPMENT SIZING CALCULATIONS | | | (MANUAL J CALCULATIONS) AS REQUIRED BY FBCR M1401.3. | | | NOTE: THE EQUIPMENT SCHEDULE ON THE MECHANICAL PLANS | | | MUST MATCH THE CALCULATIONS. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | [email protected] |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2014-03-22 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-03-22 |
Time |
10:33 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2014-03-22 |
Time |
10:33 |
Sent To |
|
|
| Notes |
| 2014-03-22 11:28:17 | 2010 FBC | | | | | | DENIED BY MECHANICAL | | | | | | 1) SUBMIT TWO SETS OF EQUIPMENT SIZING CALCULATIONS AS | | | REQUIRED BY FBCR M1401.3. NOTE: THE EQUIPMENT SCHEDULE | | | ON THE MECHANICAL PLANS MUST MATCH THE CALCULATIONS. | | | | | | 2) THE PLANS SHOW DUCT WORK IN THE CEILING. BASED ON | | | THE WALL SECTION ON SHEET 2, THIS STRUCTURE HAS A FLAT | | | ROOF AND A SINGLE ASSEMBLY ROOF/CEILING AND THE CEILING | | | HEIGHT IS SPECIFIED AS 8' 1" ON THE PLANS. THE DUCT | | | WORK WILL NEED TO BE INSTALLED IN A CHASE. PLEASE | | | CLARIFY. | | | | | | 3) THE PLANS SPECIFY THE AIR HANDLER LOCATED IN A | | | CLOSET ABOVE A STACKABLE WASHER/DRYER. THERE WILL NOT | | | BE ENOUGH ROOM TO INSTALL THE A/H AND HAVE IT | | | ACCESSIBLE FOR SERVICING. FBCR M1401.2 PLEASE CORRECT. | | | | | | 4) SPECIFY THE SIZE OF THE SUPPLY DUCT FOR THE | | | BATHROOM. NOTE: THE TRANSFER DUCT IS TO BE 1.5 TIMES | | | THE CROSS SECTIONAL AREA OF ALL THE DUCTS ENTERING THE | | | MASTER SUIT. FBC M1602.4 | | | | | | 5) SPECIFY THE LOCATION AND VENTING OF THE GAS WATER | | | HEATER. FBCR M1801 | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2014-04-28 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-04-28 |
Time |
17:43 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2014-04-28 |
Time |
17:43 |
Sent To |
|
|
| Notes |
| 2014-04-28 17:44:14 | REDLINED PLANS. CHANGED FROM LAV TO SINK AND ADDED TRAP | | | FOR TWO COMPARTMENT SINK AT KITCHEN. CHANGED FROM LAV | | | TO CLOTHES WASHER STANDPIPE. | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | 2014-04-21 16:55:28 | NEW SHEETS SUBMITTED. JG. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2014-03-22 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-03-22 |
Time |
10:21 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2014-03-22 |
Time |
10:21 |
Sent To |
|
|
| Notes |
| 2014-03-22 10:28:00 | REDLINED PLANS. CHANGED FROM LAV TO SINK AND ADDED TRAP | | | FOR TWO COMPARTMENT SINK AT KITCHEN. CHANGED FROM LAV | | | TO CLOTHES WASHER STANDPIPE. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2014-03-27 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2014-03-27 |
Time |
15:00 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2014-03-27 |
Time |
15:00 |
Sent To |
|
|
| Notes |
| 2014-03-20 16:01:35 | 3/20/14 |
|
|