Plan Review Details - Permit 14030614
Plan Review Stops For Permit 14030614
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2014-08-26 Cont ID  
Sent By jwitmer Date 2014-08-26 Time 10:41 Rev Time 0.00
Received By jwitmer Date 2014-08-26 Time 09:30 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2014-04-17 Cont ID  
Sent By jwitmer Date 2014-04-17 Time 11:55 Rev Time 0.00
Received By jwitmer Date 2014-04-17 Time 11:37 Sent To  
Notes
2014-04-17 11:55:04BUILDING PLAN REVIEW
 PERMIT: 14030614
 ADD: 6651 N JOG RD
 CONT: CDM CONSTRUCTORS
 TEL: (561)616-4522
  
 2010 FLORIDA BUILDING CODE W
 * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION
 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013.
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: THURSDAY APRIL 17/2014
 ACTION: DENIED
  
 1) THE SUBMITTED PHOTOVOLTAIC CANOPY HAS NOT APPLIED
 FOR A PERMIT TO MAKE A WHOLE ASSEMBLY. SHEET 710-A5-500
 NOTES INDICATE THE CANOPY MANUFACTURER SHALL DESIGN,
 MANUFACTURE, AND INSTALL PARKING CANOPY, PARKING CANOPY
 FOUNDATION CANOPY COMPONENTS AND PHOTOVOLTAIC ARRAY.
  
 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING
 CODE, CHAPTER 1, ADMINISTRATION, 2010
 107.3.5 MINIMUM PLAN REVIEW CRITERIA FOR BUILDINGS. THE
 EXAMINATION OF THE DOCUMENTS BY THE
 BUILDING OFFICIAL SHALL INCLUDE THE FOLLOWING MINIMUM
 CRITERIA AND DOCUMENTS: A FLOOR PLAN; SITE
 PLAN; FOUNDATION PLAN
 107.3.5.1 COMMERCIAL BUILDINGS:
 107.3.5.1.1 BUILDING
 MINIMUM BUILDING TYPE
 OCCUPANY TYPE
 STRUCTURAL REQUIREMENTS SHALL INCLUDE:
 SOIL CONDITIONS/ANALYSIS
 DESIGN LOADS
  
 WIND REQUIREMENTS
 2010 FBC-B 1609.1.1 DETERMINATION OF WIND DESIGN-
 CHAPTER 6 OF ASCE 7-10.
 1609.3 BASIC WIND SPEED FIGURE 1609.A-C
 1609.3 WIND SPEED CONVERSION
 1) THE BASIC WIND SPEED, VU, SHALL BE DETERMINED IN
 ACCORDANCE WITH 1609.3.1 & ASCE 7-10
 2) AN IMPORTANCE FACTOR, FIGURE 1609 A-C, ASCE 7-10.
 3) AN EXPOSURE CATEGORY SHALL BE DETERMINED IN
 ACCORDANCE WITH 1609.4 & ASCE 7-10
 4) A HEIGHT AND EXPOSURE ADJUSTMENT COEFFICIENT, *
 SHALL BE DETERMINED FROM TABLE 1609.7.2. ASCE 7-10.
 5) COMPONENTS & CLADDING PRESSURES POSITVE & NEGATIVE
 TABLE 1609.2(2) .
  
 PRODUCT APPROVALSFL 61G1-23.015 (2) THE ARCHITECT IS
 RESPONSIBLE FOR SUPERVISING AND REVIEWING ALL PROJECT
 DATA, REPORTS, SHOP DRAWINGS ETC..
 2010 FBC-B 1609.1.2 PROTECTION OF OPENINGS, 1609.6.4.41
 COMPONENTS & CLADDING
  
 FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS RULE 9N-3 NOV.
 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION
 SYSTEMS THAT WILL REQUIRE PRODUCT APPROVALS:
 (31)(D) ROOFING PRODUCTS AND ASSEMBLIES
  
 A THOROUGH REVIEW CAN NOT BE MADE AT THIS TIME, AS A
 RESULT OF THE ADDITIONAL INFORMATION REQUESTED
 ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF
 THIS REVIEW.
 WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION &
 REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL
 LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH
 A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE
 SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE
 FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR
 YOUR ANTICIPATED COOPERATION.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2014-09-03 Cont ID  
Sent By dhayes Date 2014-09-03 Time 16:32 Rev Time 0.00
Received By dhayes Date 2014-09-03 Time 16:32 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2014-04-16 Cont ID  
Sent By albarran Date 2014-04-16 Time 12:15 Rev Time 0.00
Received By albarran Date 2014-04-14 Time 17:55 Sent To  
Notes
2014-04-16 12:17:43PASSED ELECTRICAL REVIEW AS NOTED ON PLANS
2014-04-14 18:07:33WAITING FOR INVITE FROM STEVE

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2014-09-04 Cont ID  
Sent By cpuell Date 2014-09-04 Time 23:25 Rev Time 0.00
Received By cpuell Date 2014-08-11 Time 14:17 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2014-04-17 Cont ID  
Sent By jwitmer Date 2014-04-17 Time 11:55 Rev Time 0.00
Received By jwitmer Date 2014-03-27 Time 16:55 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2014-09-29 Cont ID  
Sent By skennedy Date 2014-09-29 Time 14:21 Rev Time 0.00
Received By skennedy Date 2014-09-26 Time 15:58 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status P Date 2014-09-03 Cont ID  
Sent By eschneid Date 2014-09-03 Time 09:35 Rev Time 0.25
Received By eschneid Date 2014-09-03 Time 09:34 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2014-04-14 Cont ID  
Sent By eschneid Date 2014-04-14 Time 15:21 Rev Time 0.25
Received By eschneid Date 2014-04-14 Time 15:21 Sent To  
Notes
2014-03-28 10:04:123/28/14


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved