| Plan Review Stops For Permit 14030509 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2014-04-17 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2014-04-17 |
Time |
14:33 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-04-17 |
Time |
14:33 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2014-03-25 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2014-03-25 |
Time |
07:57 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-03-25 |
Time |
07:49 |
Sent To |
|
|
| Notes |
| 2014-03-25 07:57:26 | BUILDING PLAN REVIEW | | | PERMIT: 14030509 | | | ADDRESS: 1801 PALM BEACH LAKES | | | CONT: EMJ | | | TEL: (561) 401-1349 | | | | | | 1ST REVIEW | | | DATE: TUESDAY MARCH 25/ 2014 | | | ACTION: DENIED | | | | | | 2010 FLORIDA BUILDING CODE W | | | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | | | 2010 EXISTING BUILDING CODE LEVEL II 701.3 | | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | | | 1) NO PLANS SUBMITTED FOR THE MANUFACTURERED BUILDING. | | | MOST OF THESE TEMPORARY OFFICES ARE STATE APPROVED | | | PLANS, NO SUCH PLAN WAS SUBMITTED. SINCE THIS IS FOR | | | CONSTRUCTION USE, WILL THIS UNIT BE USED LESS THAN 6 | | | MONTHS IF SO PROVIDE DATE TO BE INSTALLED AND DATE TO | | | BE REMOVED. | | | | | | 2) NO TIE DOWN OR FOUNDATION WAS SUBMITTED FOR THE | | | MANUFACTUREREED BUILDING, OR STAIR CONFIGURATION INTO | | | THE BUILDING. | | | | | | | | | 107.3.5.1 COMMERCIAL BUILDINGS: | | | 107.3.5.1.1 BUILDING | | | OCCUPANCY GROUP AND SPECIAL OCCUPANCY REQUIREMENTS | | | SHALL BE DETERMINED. | | | MINIMUM TYPE OF CONSTRUCTION SHALL BE DETERMINED (SEE | | | TABLE 503). | | | OCCUPANCY LOAD/EGRESS REQUIREMENTS SHALL INCLUDE: | | | OCCUPANCY LOAD | | | GROSS | | | NET | | | MEANS OF EGRESS | | | STRUCTURAL REQUIREMENTS SHALL INCLUDE: | | | DESIGN LOADS | | | WIND REQUIREMENTS | | | BUILDING ENVELOPE | | | STRUCTURAL CALCULATIONS (IF REQUIRED) | | | FOUNDATION | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2014-04-24 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2014-04-24 |
Time |
11:46 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2014-04-24 |
Time |
11:46 |
Sent To |
|
|
| Notes |
| 2014-04-24 11:47:55 | SEE PERMIT #1404058 FOR ELECTRIC. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2014-04-21 |
|
|
Cont ID |
|
| Sent By |
albarran |
Date |
2014-04-21 |
Time |
16:55 |
Rev Time |
0.00 |
| Received By |
albarran |
Date |
2014-04-21 |
Time |
16:21 |
Sent To |
I |
|
| Notes |
| 2014-04-21 17:01:56 | NO ELECTRICAL DATA PROVIDED.. THE ELECTRICAL SPECS | | | SUBMITTED ARE FOR A MANUFACTURED TRAILER THAT IS BEING | | | DELIVERED TO THE SITE ALREADY INSPECTED BY THE STATE OF | | | FLORIDA. THE ELECTRICAL DATA REQUIRED IS A SERVICE | | | RISER DIAGRAM WITH LOAD CALCS; A SITE PLAN INDICATING | | | WHERE THE POWER FOR THIS/THESE UNITS IS BEING OBTAINED | | | FROM AND A DESCRIPTION OF ALL THIS IS GOING TO GET PUT | | | TOGETHER. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2014-04-03 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2014-04-03 |
Time |
11:06 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2014-04-03 |
Time |
11:06 |
Sent To |
|
|
| Notes |
| 2014-04-03 11:07:13 | 14030509 | | | 1801 PALM BEACH LAKES BLVD. | | | OFFICE TRAILER | | | | | | PLEASE REVISE THE PLANS IN RESPONSE TO THE FOLLOWING | | | REVIEW COMMENTS. | | | | | | PROVIDE AN ELECTRIC PERMIT WITH PLANS FOR THE | | | ELECTRICAL SERVICE CONNECTION OF THE TRAILER. NEC 215.5 | | | | | | ROBERT LECKY, CBO | | | ELECTRICAL PLANS REVIEW | | | 561-373-3701 | | | | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2014-03-17 |
|
|
Cont ID |
|
| Sent By |
scaldero |
Date |
2014-03-17 |
Time |
13:25 |
Rev Time |
0.00 |
| Received By |
scaldero |
Date |
2014-03-17 |
Time |
13:25 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2014-04-24 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2014-04-24 |
Time |
11:48 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2014-04-24 |
Time |
11:48 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2014-04-21 |
|
|
Cont ID |
|
| Sent By |
albarran |
Date |
2014-04-21 |
Time |
17:04 |
Rev Time |
0.00 |
| Received By |
albarran |
Date |
2014-04-04 |
Time |
08:58 |
Sent To |
|
|
| Notes |
| 2014-04-21 17:05:50 | SPOKE W/LEXIE AND GAVE HER STATUS UPDATE. SENT TO SMALL | | | DENIED "E" | | 2014-04-08 08:59:08 | B10 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2014-04-03 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2014-04-03 |
Time |
11:07 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2014-03-13 |
Time |
17:17 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
N |
Date |
2014-04-03 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2014-04-03 |
Time |
11:07 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2014-04-03 |
Time |
11:07 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2014-04-01 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2014-04-01 |
Time |
10:17 |
Rev Time |
0.25 |
| Received By |
eschneid |
Date |
2014-04-01 |
Time |
10:17 |
Sent To |
|
|
| Notes |
| 2014-03-28 09:48:39 | 3/28/14 |
|
|