| | BUILDING PLAN REVIEW |
| | REVISION: 14030431 |
| | PERMIT: 13100374 |
| | ADD: 2921 N AUSTRALIAN AVE. |
| | CONT: DB K INDUSTRIES |
| | TEL: (561)827-4920 JAMES STINSON |
| | |
| | 1ST REVIEW |
| | DATE: SAT. MARCH 22/ 2014 |
| | ACTION: DENIED |
| | |
| | 1) SHOP DRAWING FOR HANDRAIL DOES NOT INDICATE WHERE |
| | THE LANDING IS LOCATED. IT APPEARS EITHER A SECTION IS |
| | INCORPORATED INTO THE ELEVATION DRAWING SHOWING THE |
| | BOTTOM POST AND SLAB BEING CORED OR ANOTHER RISER, |
| | PLEASE IDENTIFY WHAT IS BEING ILLUSTRATED. |
| | |
| | 2) THE SHOP DRAWING FOR A HANDRAIL WILL NEED TO COMPLY |
| | WITH THE 2010 FL ACCESSIBILITY CODE 504.6 HANDRAILS. |
| | STAIRS SHALL HAVE HANDRAILS COMPLYING WITH 505. |
| | 505.2 WHERE REQUIRED. HANDRAILS SHALL BE PROVIDED ON |
| | BOTH SIDES OF STAIRS AND RAMPS. |
| | |
| | 2A) 505.10 HANDRAIL EXTENSIONS. HANDRAIL GRIPPING |
| | SURFACES SHALL EXTEND BEYOND AND IN THE SAME DIRECTION |
| | OF STAIR FLIGHTS AND RAMP RUNS IN ACCORDANCE WITH |
| | 505.10. |
| | 2B) |
| | 05.10.2 TOP EXTENSION AT STAIRS. AT THE TOP OF A STAIR |
| | FLIGHT, HANDRAILS SHALL EXTEND HORIZONTALLY ABOVE THE |
| | LANDING FOR 12 INCHES (305 MM) MINIMUM BEGINNING |
| | DIRECTLY ABOVE THE FIRST RISER NOSING. EXTENSIONS SHALL |
| | RETURN TO A WALL, GUARD, OR THE LANDING SURFACE, OR |
| | SHALL BE CONTINUOUS TO THE HANDRAIL OF AN ADJACENT |
| | STAIR FLIGHT. |
| | |
| | 2C) 505.10.3 BOTTOM EXTENSION AT STAIRS. AT THE BOTTOM |
| | OF A STAIR FLIGHT, HANDRAILS SHALL EXTEND AT THE SLOPE |
| | OF THE STAIR FLIGHT FOR A HORIZONTAL DISTANCE AT LEAST |
| | EQUAL TO ONE TREAD DEPTH BEYOND THE LAST RISER NOSING. |
| | EXTENSION SHALL RETURN TO A WALL, GUARD, OR THE LANDING |
| | SURFACE, OR SHALL BE CONTINUOUS TO THE HANDRAIL OF AN |
| | ADJACENT STAIR FLIGHT. |
| | |
| | 3) PLEASE NOTE: THIS BUILDING IS BEING CONVERTED INTO A |
| | FUNERAL HOME. THE OWNER HAS NOT APPLIED FOR A CHANGE OF |
| | OCCUPANCY PERMIT. NOR WILL A CHANGE OF OCCUPANCY PERMIT |
| | BE GRANTED. THIS IS A ZONING ISSUE ANGELLIA JONES VANN |
| | MADE THE OWNER AWARE OF LAST YEAR. |
| | |
| | A THOROUGH REVIEW CAN NOT BE MADE AT THIS TIME, AS A |
| | RESULT OF THE ADDITIONAL INFORMATION REQUESTED |
| | ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF |
| | THIS REVIEW. |
| | |