Plan Review Details - Permit 14030382
| Plan Review Stops For Permit 14030382 |
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2014-03-25 |
|
|
Cont ID |
|
| Sent By |
dhayes |
Date |
2014-03-25 |
Time |
09:48 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
2014-03-25 |
Time |
09:48 |
Sent To |
FIRE |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2014-03-18 |
|
|
Cont ID |
|
| Sent By |
albarran |
Date |
2014-03-18 |
Time |
13:55 |
Rev Time |
0.00 |
| Received By |
albarran |
Date |
2014-03-18 |
Time |
13:31 |
Sent To |
I |
|
| Notes |
| 2014-03-18 13:54:56 | THIS APPLICATION FOR PERMIT CAME UP FOR REVIEW AND THE | | | FOLLOWING DEFICIENCIES WERE NOTED: | | | 1. PROVIDE A REASONABLE VALUATION BASED ON THE COST OF | | | THE WORK INCLUSIVE OF LABOR AND MATERIALS REGARDLESS OF | | | FEES CHARGED. | | | 2. AS PER THE FBC 907.1.2 YOUR SUBMITTAL IS MISSING THE | | | REQUIRED VOLTAGE DROP CALCULATIONS AND THE LOCATION OF | | | THE PRIMARY POWER SOURCE. | | | 3. PROVIDE AN INDICATION AS TO WHAT THE CK ROOM IS. | | | | | | IF YOU HAVE ANY QUESTIONS WITH REGARDS TO THIS REVIEW, | | | PLEASE DO NOT HESITATE TO CONTACT ME: | | | MIKE ALBARRAN, ELECTRICAL PLANS EXAMINER CITY OF WEST | | | PALM BEACH | | | PH: (561) 805-6718 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2014-03-25 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2014-03-25 |
Time |
16:58 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2014-03-25 |
Time |
16:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2014-03-14 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2014-03-14 |
Time |
13:39 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2014-03-14 |
Time |
13:39 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2014-03-25 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2014-03-25 |
Time |
16:58 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2014-03-24 |
Time |
08:50 |
Sent To |
|
|
| Notes |
| 2014-03-24 08:51:47 | INCOMIONG SENT TO <$5K ELECTRIC BOX. JW |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2014-03-18 |
|
|
Cont ID |
|
| Sent By |
albarran |
Date |
2014-03-18 |
Time |
14:13 |
Rev Time |
0.00 |
| Received By |
albarran |
Date |
2014-03-11 |
Time |
15:03 |
Sent To |
|
|
| Notes |
| 2014-03-18 14:14:29 | SMALL DENIED BIN "T" | | 2014-03-11 15:03:41 | FIRE | | | |
|
|
|