Plan Review Details - Permit 14030035
Plan Review Stops For Permit 14030035
Review Stop E ELECTRICAL
Rev No 1 Status P Date 2014-03-03 Cont ID  
Sent By albarran Date 2014-03-03 Time 19:46 Rev Time 0.00
Received By albarran Date 2014-03-03 Time 19:25 Sent To I
Notes
2014-03-03 19:47:04314.27 OUTLET BOXES.
 (A) BOXES AT LUMINAIRE OUTLETS. BOXES USED AT LUMINAIRE
 OR LAMPHOLDER OUTLETS IN A CEILING SHALL BE DESIGNED
 FOR THE
 PURPOSE AND SHALL BE REQUIRED TO SUPPORT A LUMINAIRE
 WEIGHING
 A MINIMUM OF 23 KG (50 LB). BOXES USED AT LUMINAIRE OR
 LAMPHOLDER OUTLETS IN A WALL SHALL BE DESIGNED FOR THE
 PURPOSE
 AND SHALL BE MARKED TO INDICATE THE MAXIMUM WEIGHT
 OF THE LUMINAIRE THAT IS PERMITTED TO BE SUPPORTED BY
 THE
 BOX IN THE WALL, IF OTHER THAN 23 KG (50 LB). AT EVERY
 OUTLET
 USED EXCLUSIVELY FOR LIGHTING, THE BOX SHALL BE
 DESIGNED OR
 INSTALLED SO THAT A LUMINAIRE MAY BE ATTACHED.
  

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2014-03-03 Cont ID  
Sent By albarran Date 2014-03-03 Time 19:47 Rev Time 0.00
Received By albarran Date 2014-03-03 Time 11:43 Sent To PC
Notes
2014-03-03 19:47:33SAK BOX
  
2014-03-03 11:43:48<5000 ELEC