Plan Review Details - Permit 14030027
Plan Review Stops For Permit 14030027
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2014-03-04 Cont ID  
Sent By skennedy Date 2014-03-04 Time 15:22 Rev Time 0.00
Received By skennedy Date 2014-03-04 Time 15:22 Sent To  
Notes
2014-03-04 15:38:10THIS SUBMITTAL IS PROVISIONALLY APROVED COMPLIANCE WITH
 THE FOLLOWING SECTIONS IS REQUIRED:
 R702.3.8 WATER-RESISTANT GYPSUM BACKING BOARD.
 GYPSUM BOARD USED AS THE BASE OR BACKER FOR ADHESIVE
 APPLICATION OF CERAMIC TILE OR OTHER REQUIRED
 NONABSORBENT FINISH MATERIAL SHALL CONFORM TO ASTM C
 1396, C 1178 OR C1278. USE OF WATER-RESISTANT GYPSUM
 BACKING BOARD SHALL BE PERMITTED ON CEILINGS WHERE
 FRAMING SPACING DOES NOT EXCEED 12 INCHES (305 MM) ON
 CENTER FOR 1/2-INCH-THICK (12.7 MM) OR 16 INCHES (406
 MM) FOR 5/8-INCH-THICK (16 MM) GYPSUM BOARD.
 WATER-RESISTANT GYPSUM BOARD SHALL NOT BE INSTALLED
 OVER A CLASS I OR II VAPOR RETARDER IN A SHOWER OR TUB
 COMPARTMENT. CUT OR EXPOSED EDGES, INCLUDING THOSE AT
 WALL INTERSECTIONS, SHALL BE SEALED AS RECOMMENDED BY
 THE MANUFACTURER.
  
 R702.4 CERAMIC TILE.
  
 R702.4.1 GENERAL.
 CERAMIC TILE SURFACES SHALL BE INSTALLED IN ACCORDANCE
 WITH ANSI A108.1, A108.4, A108.5, A108.6, A108.11,
 A118.1, A118.3, A136.1 AND A137.1.
  
 R702.4.2 FIBER-CEMENT, FIBER-MAT REINFORCED CEMENT,
 GLASS MAT GYPSUM BACKERS AND FIBER-REINFORCED GYPSUM
 BACKERS.
 FIBER-CEMENT, FIBER-MAT REINFORCED CEMENT, GLASS MAT
 GYPSUM BACKERS OR FIBER-REINFORCED GYPSUM BACKERS IN
 COMPLIANCE WITH ASTM C 1288, C 1325, C 1178 OR C 1278,
 RESPECTIVELY, AND INSTALLED IN ACCORDANCE WITH
 MANUFACTURERS? RECOMMENDATIONS SHALL BE USED AS BACKERS
 FOR WALL TILE IN TUB AND SHOWER AREAS AND WALL PANELS
 IN SHOWER AREAS.
  
 STEVEN KENNEDY, CBO
 CHIEF PLANS EXAMINER
 (561) 805-6710
 [email protected]
  
  

Review Stop E ELECTRICAL
Rev No 1 Status N Date 2014-03-04 Cont ID  
Sent By skennedy Date 2014-03-04 Time 15:22 Rev Time  
Received By skennedy Date   Time   Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2014-03-04 Cont ID  
Sent By skennedy Date 2014-03-04 Time 15:22 Rev Time 0.00
Received By skennedy Date 2014-03-03 Time 18:48 Sent To  
Notes
2014-03-03 18:49:05TO SK DESK
  

Review Stop P PLUMBING
Rev No 1 Status P Date 2014-03-04 Cont ID  
Sent By skennedy Date 2014-03-04 Time 15:22 Rev Time 0.00
Received By skennedy Date 2014-03-04 Time 15:22 Sent To  
Notes
***NONE***