Plan Review Details - Permit 14021103
| Plan Review Stops For Permit 14021103 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2014-04-14 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-04-14 |
Time |
10:31 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2014-04-14 |
Time |
08:58 |
Sent To |
|
|
| Notes |
| 2014-04-14 08:59:39 | 2010 FBC | | | | | | DENIED BY BUILDING | | | | | | 1) THE STRUCTURE IS LOCATED IN EXPOSURE CATEGORY 'C' | | | AND HAS A 170 MPH VULT WINDSPEED. THE DESIGN PRESSURE | | | FOR THE MULE-HIDE SELF ADHERED ROOF SYSTEM ON PAGE 18 | | | OF NOA NO. 13-0514.12 IS 52.5 PSF. THIS IS NOT ADEQUATE | | | FOR THE PERIMETER AND CORNERS AREAS OF THE FLAT ROOF. | | | SUBMIT TWO SETS OF SIGNED AND SEALED RAS 117 | | | CALCULATIONS FOR ENHANCED FASTENING OF THE BASE SHEET | | | AS REQUIRED BY LIMITATION NUMBER 7 ON PAGE 24 OF THE | | | NOA. FBCR 301.2.1 | | | | | | 2) SPECIFY WHICH METHOD OF ATTACHMENT LISTED IN THE | | | ENTEGRA ROOF TILE PRODUCT APPROVAL (NOA NO.10-1202.01) | | | WILL BE USED TO INSTALL THE ROOF TILE SO THAT IT IS | | | CAPABLE OF RESISTING THE REQUIRED OVERTURN MOMENT. IF | | | AN ADHESIVE WILL BE USED TO ATTACH THE TILE, SUBMIT TWO | | | COPIES OF THE PRODUCT APPROVALS FOR IT. FBCR 301.2.1 & | | | DCA RULE 9N-3 | | | | | | 3) THE VALUE FOR THE WORK IS SPECIFIED AS $2000.00 ON | | | THE APPLICATION. THIS VALUE IS TOO LOW TO RE-ROOF THE | | | SLOPE AND FLAT AREAS OF THIS STRUCTURE. BASED ON | | | MARSHALL AND SWIFT VALUATIONS, THE TOTAL VALUE FOR | | | RE-ROOFING THE 1380 SQFT SLOPED TILE ROOF AND THE 1207 | | | SQFT FLAT ROOF IS $13,200.00. THE VALUE FOR THE WORK | | | HAS BEEN ADJUSTED FROM $2000.00 TO $13,200.00. CITY | | | AMENDMENTS 109.3 | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2014-03-03 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2014-03-03 |
Time |
18:00 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2014-03-03 |
Time |
18:00 |
Sent To |
|
|
| Notes |
| 2014-03-03 18:05:17 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | 1. SCOPE NOT CLEAR. APPLICATION STATES THAT EXISTING | | | ROOFING WILL BE REMOVED, AND "SECURE SLOPED ROOF." WHAT | | | DOES THIS MEAN? | | | | | | 2. THE PRODUCT APPROVAL SUBMITTED IS FOR A RECOVER ON A | | | CONCRETE DECK. THE SUBSTRATE AT THIS PROPERTY APPEARS | | | TO BE A WOOD DECK. APPLICATION STATES THAT EXISTING | | | ROOF IS TO BE REMOVED. | | | | | | 3. A VALUATION ADJUSTMENT WILL BE DONE AFTER SCOPE HAS | | | BEEN DETERMINED. | | | | | | |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
2 |
Status |
P |
Date |
2014-04-09 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2014-04-09 |
Time |
14:26 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2014-04-09 |
Time |
14:26 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
P |
Date |
2014-03-03 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2014-03-03 |
Time |
13:54 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2014-03-03 |
Time |
13:54 |
Sent To |
|
|
| Notes |
| 2014-03-03 13:55:05 | APPROVED FOR FLAT ROOF ONLY. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2014-03-03 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2014-03-03 |
Time |
18:05 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2014-03-03 |
Time |
18:05 |
Sent To |
|
|
| Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |