Plan Review Details - Permit 14020875
Plan Review Stops For Permit 14020875
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2014-04-22 Cont ID  
Sent By jwitmer Date 2014-04-22 Time 13:18 Rev Time 0.00
Received By jwitmer Date 2014-04-22 Time 13:18 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2014-03-14 Cont ID  
Sent By jwitmer Date 2014-03-14 Time 16:28 Rev Time 0.00
Received By jwitmer Date 2014-03-13 Time 14:35 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2014-04-29 Cont ID  
Sent By RLECKY Date 2014-04-29 Time 11:13 Rev Time 0.00
Received By rlecky Date 2014-04-29 Time 10:50 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2014-03-25 Cont ID  
Sent By rlecky Date 2014-03-25 Time 11:18 Rev Time 0.00
Received By rlecky Date 2014-03-25 Time 11:18 Sent To  
Notes
2014-03-25 11:20:0914020875
 901 45TH STREET
 ST. MARY?S INC. - TEMP DIALYSIS
  
 PLEASE REVISE THE PLANS IN RESPONSE TO THE FOLLOWING
 REVIEW COMMENTS.
  
 SHEET E001
  THE FEEDER FROM THE TEMPORARY GENERATOR TO THE ATS
 DOES NOT APPEAR TO BE PROPERLY SIZED. MAXIMUM
 OVERCURRENT PROTECTION FOR 3/0 CU. IS LIMITED TO 200
 AMPS. NEC 310.16
  
 SHEET E211
  INDICATE ON THE PLAN THE APPROPRIATE WIRING METHOD
 NECESSARY TO PROVIDE AN EFFECTIVE GROUND FAULT CURRENT
 PATH FOR THE BRANCH CIRCUITS AND PANEL BOARDS SERVING
 THE PATIENT CARE AREAS. NEC 517.13; 517.14
  
 NOTE: SEPARATE PERMITS AND PLANS ARE REQUIRED FOR THE
 GENERATOR, ALARM SYSTEMS, SECURITY AND DATA SYSTEMS.
  
 ROBERT LECKY, CBO
 ELECTRICAL PLANS REVIEW
 561-373-3701
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2014-03-04 Cont ID  
Sent By pleduc Date 2014-03-04 Time 14:05 Rev Time 0.00
Received By pleduc Date 2014-03-04 Time 13:15 Sent To  
Notes
2014-03-04 14:00:45THE PROJECT WAS REVIEWED BY PETER LEDUC, FIRE MARSHAL,
 BUREAU OF FIRE PREVENTION, WEST PALM BEACH FIRE RESCUE.
  
 NO COMMENTS WERE SUBMITTED AS PART OF THE APPROVAL
 PROCESS.

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2014-04-29 Cont ID  
Sent By rlecky Date 2014-04-29 Time 11:16 Rev Time 0.00
Received By rlecky Date 2014-04-11 Time 09:01 Sent To  
Notes
2014-04-12 09:01:20B25

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2014-03-25 Cont ID  
Sent By rlecky Date 2014-03-25 Time 11:21 Rev Time 0.00
Received By rlecky Date 2014-02-24 Time 11:32 Sent To  
Notes
2014-02-25 11:33:31SENT TO B14 SHELF FOR REVIEW. JG.

Review Stop P PLUMBING
Rev No 2 Status P Date 2014-04-22 Cont ID  
Sent By JWITMER Date 2014-04-22 Time 13:17 Rev Time 0.00
Received By jwitmer Date 2014-04-22 Time 12:17 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2014-03-14 Cont ID  
Sent By jwitmer Date 2014-03-14 Time 16:27 Rev Time 0.00
Received By jwitmer Date 2014-03-13 Time 14:35 Sent To  
Notes
2014-03-14 16:27:51PLUMBING PLAN REVIEW
 PERMIT:14020875
 ADD: 901 45TH ST
 CONT: WESTBROOKE
 TEL: (561)395-4126
  
 2010 FLORIDA BUILDING CODE W
 * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION
 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013.
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: FRIDAY MARCH 14/ 2014
 ACTION: DENIED
  
 1) PLEASE PROVIDE CONFIRMATION IN ROOMS 105 & 112 THERE
 ALREADY EXIST FLOOR SINKS, THEY DO NOT APPEAR ON THE
 DEMO PLAN, SHEET A111 THE FLOOR SINK IS INDICATED IN
 ROOM 101, IN ROOM 112 THERE REMAINS A CABINET AND SINK.
 NEITHER THE DEMO OR ARCHITECTURAL INDICATE AN EXISTING
 FLOOR SINK PLEASE VERIFY EXISTING OR IS THIS NEW WORK.
 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING
 CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION 107.2.1.3
 ADDITIONAL INFORMATION IS REQUIRED.
  
 2) SHEET P211 INDICATES THIS TO BE A GRAVITY WASTE
 PIPING SYSTEM, ACTUALLY 2 INDEPENDANT SYSTEMS. THE
 PLANS ARE NOT CLEAR IF THE GRAVITY LINES
 (PIPES) ARE LOCATED ABOVE THE FLOOR SLAB OR BELOW AND
 IF THE CENRALLY LOCATED SUMP PUMP TANK EXTENDS BENEATH
 THE FLOOR SLAB. A THERE ARE 2 CONCERNS OF INTEREST THAT
 WILL NEED TO BE STATISFIED OR CLARIFIED.
 2A) THE PLANS INDICATE ON THE SUMP PUMP CONTAINER THE
 USE OF A AIR ADMITANCE VALVE. 2010 FBC-P WOULD REQUIRE
 THE EXHAUSTS FROM A VACUUM PUMP SERVING A VACUUM (FLUID
 SUCTION) SYSTEM SHALL DISCHARGE SEPARATELY TO OPEN AIR
 ABOVE THE ROOF. IS THERE A VACUUM PUMP INSTALLED WITHIN
 THIS SYSTEM? IS THIS TRUELY 2 INDEPENDANT DISPOSAL
 SYSTEMS.
  
 2B) THE SECOND ISSUE IS THE SUMP DRAIN DETAIL FOUND ON
 P211 SHOWS A 2 INCH INDIRECT WASTE AND FUNNEL DRAIN.
 2010 FBC-P 713.7 CENTRAL VACUUM OR DISPOSAL SYSTEMS.
 WHERE THE WASTE FROM A CENTRAL VACUUM (FLUID SUCTION)
 SYSTEM OF THE BAROMETRIC-LAG, COLLECTION-TANK OR
 BOTTLE-DISPOSAL TYPE IS CONNECTED TO THE DRAINAGE
 SYSTEM, THE WASTE SHALL BE DIRECTLY CONNECTED TO THE
 SANITARY DRAINAGE SYSTEM THROUGH A TRAPPED WASTE. THIS
 IS INTENDED TO MINIMIZE POSSIBLE CONTAMINATION BY
 PREVENTING THE WASTE FROM BEING EXPOSED TO THE
 ATMOSPHERE.
  
 3) SHEET A111 ROOM 122 SHOW RO (REVERSE OSMOSIS)
 MACHINE, WATER SOFTNER, EXCHANGE CARBONS AND BUSTER
 PUMPS BUT THE PLUMBING PLANS DO NOT PROVIDE HOW THESE
 SYSTEMS OPERATE, THERE ARE NO MANUFACTURER CUT SHEET ON
 THIS EQUIPMENT, THERE IS NOT ENOUGH INFORMATION
 PROVIDED, A THOROUGH REVIEW CAN NOT BE MADE AT THIS
 TIME, AS A RESULT OF THE ADDITIONAL INFORMATION
 REQUESTED ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT
 PART OF THIS REVIEW.
  
  
  