Plan Review Details - Permit 14020538
| Plan Review Stops For Permit 14020538 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2014-03-11 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2014-03-11 |
Time |
07:44 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2014-03-05 |
Time |
15:38 |
Sent To |
|
|
| Notes |
| 2014-03-11 08:31:55 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | 1. DOCUMENTS PREPARED BY AN ENGINEER AND SUBMITTED FOR | | | PUBLIC RECORD ARE TO BE SIGNED, SEALED, DATED ORIGINALS | | | FS471. | | | | | | 2. ALL INFORMATION REQUIRED BY FAC61G15-23.002 REQUIRED | | | ON EACH SHEET (CERTIFICATE OF AUTHORIZATION). | | | | | | 3. SCOPE NOT CLEAR. SOME SHEETS MARKED INFORMATIONAL | | | HAVE STRUCTURAL/INSTALLATION SPECIFICATIONS. IF THIS | | | EQUIPMENT IS EXISTING, REVISE TO STATE THAT THE | | | EQUIPMENT IS EXISTING. ALL NEW INSTALLATIONS ARE TO | | | INCLUDE SPECIFICATIONS FOR INSTALLATION AND WIND DESIGN | | | CRITERIA FBC 1609. | | | | | | 4. VALUE IS TO INCLUDE LABOR, MATERIALS, OVERHEAD, | | | PROFIT, ENGINEERING, EVEN IF THESE ITEMS ARE SUPPLIED | | | TO THE CONTRACTOR. REVISE. A VERIFIABLE CONTRACT MAY BE | | | REQUIRED, FBC 109. | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2014-03-04 |
|
|
Cont ID |
|
| Sent By |
dhayes |
Date |
2014-03-04 |
Time |
14:59 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
2014-03-04 |
Time |
14:48 |
Sent To |
|
|
| Notes |
| 2014-03-04 14:58:43 | PLANS HAVE INCONSISTANCIES. SHEET E-2 SHOWS A 480V | | | UTILITY SERVICE WITH A 240V PANEL. PANEL SCHEDULE LOAD | | | CALCS ARE INCONSISTANT WITH INFORMATION GIVEN IN THE | | | PANEL SCHEDULES. GROUNDING DETAILS SHOWN ON SHEET E-5 | | | BUT NOT SPECIFIED ON SHEET E-2. DAH |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2014-03-11 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2014-03-11 |
Time |
08:31 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2014-02-13 |
Time |
11:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2014-02-27 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2014-03-05 |
Time |
15:41 |
Rev Time |
0.00 |
| Received By |
ajones |
Date |
2014-02-18 |
Time |
10:06 |
Sent To |
B |
|
| Notes |
| 2014-02-18 10:08:33 | 2/14/14 SENT TO AV FOR REVIEW. SG |
|
|
|