| Plan Review Stops For Permit 14020415 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2014-05-27 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-05-27 |
Time |
09:12 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2014-05-24 |
Time |
11:06 |
Sent To |
|
|
| Notes |
| 2014-05-27 09:22:45 | PROVISO | | | | | | 1) SUBMIT A LETTER FROM THE MANUFACTURER'S TECHNICAL | | | REPRESENTATIVE THAT STATES THE WOLF OUTDOOR GRILL CAN | | | BE USED UNDER THE WOOD CEILING ON THE COVERED PORCH. | | | | | | 2) SUBMIT TWO SETS OF PRODUCT APPROVALS THAT HAVE BEEN | | | APPROVED IN WRITING BY THE DESIGNER OF RECORD FOR THE | | | FIBERGLASS DOOR #3 AND THE 1/2 CLAD FRENCH DOOR #4 AS | | | REQUIRED BY DCA RULE 9N-3. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2014-05-06 |
|
|
Cont ID |
|
| Sent By |
RMCDOUGA |
Date |
2014-05-06 |
Time |
17:44 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2014-05-02 |
Time |
08:56 |
Sent To |
|
|
| Notes |
| 2014-05-05 08:58:57 | 2010 FBC | | | | | | DENIED BY BUILDING | | | | | | 1) THE PRE-CONSTRUCTION ELEVATION CERTIFICATE THAT WAS | | | SUBMITTED HAS A COUPLE OF DISCREPANCIES WITH THE PLANS. | | | PLEASE CORRECT. | | | (A) THE PLANS SHOW ENGINEERED FLOOD OPENINGS AT THE | | | GARAGE AND ITEM A9 ON THE ELEVATION CERTIFICATE | | | SPECIFIES THAT THERE ARE NOT ANY FLOOD VENTS. | | | (B) THE PLANS STATE THAT ALL EQUIPMENT IS TO BE AT OR | | | ABOVE 7.5 FEET NGVD AND SECTION C2 (E) SPECIFIES THE | | | LOWEST EQUIPMENT AT 8.00 FEET. | | | | | | 2) THE FLOOD VENTS IN THE GARAGE ARE REQUIRED TO BE ON | | | AT LEAST TWO SIDES OF EACH ENCLOSED AREA AND ONLY THE | | | PORTION OF THE FLOOD VENT OPENING THAT IS BELOW THE | | | 7.5' BFE CAN BE COUNTED TOWARD THE REQUIRED NET OPEN | | | AREA. ONE SQUARE INCH OF NET OPEN AREA IS REQUIRED FOR | | | EACH SQUARE FOOT OF ENCLOSED AREA. SEE FEMA TECHNICAL | | | BULLETIN 1 / AUGUST 2008. PLEASE REVISE PLANS AND | | | PROVIDE CALCULATIONS TO SHOW COMPLIANCE. CITY OF WEST | | | PALM BEACH FLOOD ORDINANCE AND FBCR322. | | | | | | 3) THERE ARE SOME DISCREPANCIES IN THE ROOF PITCH THAT | | | IS SPECIFIED ON THE ON THE PLANS. ON SHEETS A4 & A5 THE | | | PITCH IS 5/12 AND ON SHEETS A3, T2, S3, S4 AND S5 THE | | | PITCH IS 6/12. SHEET T1 HAS A 5/12 ROOF SLOPE WITH A | | | 6/12 RAKE BEAM SPECIFIED. PLEASE COORDINATE THE ROOF | | | PITCH ON ALL PLANS, ELEVATIONS AND DETAILS. CITY | | | AMENDMENTS 107.2.1 | | | | | | 4) THE INSTALLATION INSTRUCTIONS FOR THE WOLF OUTDOOR | | | GRILL SPECIFY THAT IT IS NOT TO BE LOCATED UNDER | | | OVERHEAD COMBUSTIBLES. THE PLANS INDICATE THAT THE | | | CEILING OF THE OUTDOOR KITCHEN ABOVE THE GRILL WILL BE | | | WOOD. INDICATE HOW THIS WILL BE RESOLVED. CITY | | | AMENDMENTS 107.2.1 | | | | | | 5) CLARIFY WHETHER ROLL DOWN SCREENS OR ROLL DOWN STORM | | | PANELS WILL BE INSTALLED AT THE OUTDOOR KITCHEN. SUBMIT | | | MANUFACTURER'S INSTALLATION REQUIREMENTS FOR ROLL DOWN | | | SCREENS AND PRODUCT APPROVALS FOR ROLL DOWN STORM | | | PANELS. CITY AMENDMENTS 107.2.1 AND DCA RULE 9N-3 | | | | | | 6) THE RESPONSE LETTER INDICATES THAT THE SURFACE WATER | | | DRAINAGE PLAN SHOWING COMPLIANCE WITH FBC R401.3 IS ON | | | CIVIL DRAWING C-1. THERE WAS NO SHEET C-1 IN THE PLANS | | | THAT WERE SUBMITTED. PLEASE PROVIDE THE DRAWINGS THAT | | | SHOW COMPLIANCE. | | | | | | 7) SUBMIT TWO COPIES OF PRODUCT APPROVALS FOR THE | | | FOLLOWING: 8" WIDE PRECAST LINTELS, STRUCTURAL WINDOW | | | MULLIONS, CUSTOM MAHOGANY FRONT DOOR WITH SIDELITES AND | | | TRANSOM ASSEMBLY, FIBER GLASS RAISED PANEL SWING DOOR | | | AND FRENCH DOORS AS REQUIRED BY DCA RULE 9N-3. | | | | | | 8) PRODUCT APPROVALS REQUIRED BY RULE 9N-3 ARE REQUIRED | | | TO BE REVIEWED AND APPROVED IN WRITING BY THE DESIGNER | | | OF RECORD FOR THE PROJECT. CITY AMENDMENTS 107.3.4.1 | | | | | | 9) PROVIDE STRAPPING AND CONNECTOR DETAILS FOR THE FAUX | | | CHIMNEY TO PROVIDE A CONTINUOUS LOAD PATH. FBC R301.1 | | | | | | 10) IN ORDER TO REDUCED REVIEW TIME, PLEASE SUBMIT A | | | RESPONSE LETTER INDICATING HOW EACH OF THE REVIEW | | | COMMENTS WAS ADDRESSED. | | | | | | NOTE: SEPARATE APPLICATIONS, PERMITS AND REVIEWS ARE | | | REQUIRED FOR THE GENERATOR, POOL, FIRE PIT, NATURAL | | | GAS, RETAINING WALL, FENCES AND SITE WALLS. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2014-04-01 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-03-29 |
Time |
12:29 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2014-03-29 |
Time |
10:23 |
Sent To |
E |
|
| Notes |
| 2014-03-29 11:07:46 | 2010 BC | | | | | | DENIED BY BUILDING | | | | | | 1) THE PROPOSED CONSTRUCTION IS LOCATED IN AN A5 FLOOD | | | ZONE WITH A 7' BASE FLOOD ELEVATION. THE CITY OF WEST | | | PALM BEACH' S FLOOD ORDINANCE REQUIRES A 6" FREE-BOARD. | | | THEREFORE, THE SINGLE FAMILY DWELLING AND ALL OF THE | | | EQUIPMENT THAT SERVICE THE STRUCTURE ARE REQUIRED TO | | | HAVE A MINIMUM FINISH FLOOR ELEVATION AT OR ABOVE 7.5' | | | BFE NGVD 1929. SPECIFY THE PROPOSED ELEVATIONS FOR THE | | | DWELLING AND EQUIPMENT ON THE PLANS. BECAUSE THE | | | CURRENT FEMA FLOOD INSURANCE RATE MAPS (FIRM) THAT ARE | | | ADOPTED BY THE CITY OF WPB USE THE NGVD 1929 FOR | | | DETERMINING ELEVATIONS, PLEASE SPECIFY ALL ELEVATIONS | | | IN NGVD 1929 ON THE PLANS. CITY AMENDMENTS 107.2.1 AND | | | FBC R322 | | | | | | 2) SUBMIT TWO SETS OF ELEVATION CERTIFICATES FOR THE | | | PROPOSED DWELLING. ADDITIONAL ELEVATION CERTIFICATES | | | WILL BE REQUIRED PRIOR TO FINAL INSPECTION. CITY | | | AMENDMENTS 107.2.1 AND FBC R322 | | | | | | 3) SUBMIT TWO SETS OF PLANS THAT SHOW COMPLIANCE WITH | | | FBC R401.3 FOR SURFACE WATER DRAINAGE AWAY FROM THE | | | STRUCTURE AND TO AN APPROVED POINT OF COLLECTION. | | | | | | 4) THE STRUCTURE IS LOCATED ON THE INTER-COASTAL WATER | | | WAY AND IS CONSIDERED TO BE EXPOSURE D PER FBC | | | R301.2.1.4.3. THE PLANS SPECIFY IT AS EXPOSURE C. | | | PLEASE REVISE THE PLANS AS NECESSARY. | | | | | | 5) SUBMIT TWO COPIES OF THE MANUFACTURER'S INSTALLATION | | | INSTRUCTIONS AND LISTING FOR THE VENT-LESS FIREPLACE. | | | CITY AMENDMENTS 107.2.1 AND FBC R1004.1 | | | | | | 6) SUBMIT TWO COPIES OF THE PRODUCT EVALUATION AND THE | | | MANUFACTURER'S INSTALLATION INSTRUCTIONS FOR THE SPRAY | | | FOAM INSULATION THAT WILL BE INSTALLED. | | | | | | 7) SUBMIT TWO COPIES OF THE MANUFACTURER'S INSTALLATION | | | INSTRUCTIONS AND LISTING FOR THE GAS BBQ GRILL LOCATED | | | ON THE COVERED PATIO. CITY AMENDMENTS 107.2 AND FBCR | | | M1901.2 | | | | | | 8) SUBMIT TWO COPIES OF PRODUCT APPROVALS FOR THE | | | FOLLOWING: METAL ROOFING, ROOFING MATERIAL FOR FLAT | | | ROOF, WATER PROOFING SYSTEM THAT WILL BE USED ON SECOND | | | FLOOR BALCONY, 8" PRECAST LINTELS, FIXED WINDOWS, | | | STRUCTURAL WINDOW MULLIONS, CUSTOM MAHOGANY FRONT DOOR | | | ASSEMBLY, FIBER GLASS RAISED PANEL SWING DOOR AND | | | FRENCH DOORS AS REQUIRED BY DCA RULE 9N-3. | | | | | | 9) PRODUCT APPROVALS REQUIRED BY RULE 9N-3 ARE REQUIRED | | | TO BE REVIEWED AND APPROVED IN WRITING BY THE DESIGNER | | | OF RECORD FOR THE PROJECT. CITY AMENDMENTS 107.3.4.1 | | | | | | 10) IN ORDER TO REDUCED REVIEW TIME, PLEASE SUBMIT A | | | RESPONSE LETTER INDICATING HOW EACH OF THE REVIEW | | | COMMENTS WAS ADDRESSED. | | | | | | NOTE: SEPARATE APPLICATIONS, PERMITS AND REVIEWS ARE | | | REQUIRED FOR THE GENERATOR, POOL, FIRE PIT, NATURAL | | | GAS, RETAINING WALL, FENCES AND SITE WALLS. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2014-05-21 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-05-27 |
Time |
10:27 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
2014-05-20 |
Time |
17:46 |
Sent To |
|
|
| Notes |
| 2014-05-21 07:50:19 | PREAPRED TO ISSUE WITH ELECTRICAL PROVISO: | | | | | | 1) PROVIDE SMOKE DETECTORS AS REQUIRED FOR NEW | | | DWELLINGS. FBC-R314.3.1, 315.1, FBC 107.3.5 PLEASE | | | PROVIDE ONE ADDITIONAL SMOKE/CO DETECTOR AT THE FIRST | | | AND SECOND FL LANDINGS. | | | | | | 2) RECESSED LIGHTS. REQUIRES THAT RECESSED LUMINAIRES | | | BE SEALED, AIR TIGHT, IC RATED. 2010 FBC 402.4.5 | | | | | | 3) PROTECTION FROM PHYSICAL DAMAGE TO BE PROVIDED FOR | | | ELECTRICAL PANELS IN GARAGE. NEC 110.27 B | | | | | | 4) PROVIDE THE ARC FAULT CALCULATION TO INDICATE THE | | | AIC RATING ON SERVICE SWITCHGEAR. NEC 110.9 AND 110.10 | | | | | | 5) PROVIDE CUT SHEETS ON INFLOOR UP LIGHTS AND DROP | | | DOWN SCREENS TO INDICATE COMPLIANCE WITH THE NEC 110.3 | | | | | | 6) ALL NEW RECEPTACLES MUST BE TAMPER RESISTANT. THOSE | | | OUTLETS IN WET LOCATIONS SHALL BE GFI & WEATHER | | | RESISTANT NEC 406.8(B), 406.11 | | | | | | DAVID HAYES, ELECTRICAL PLANS EXAMINER, PX3421. | | | 561-805-6717 OR [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2014-04-29 |
|
|
Cont ID |
|
| Sent By |
DHAYES |
Date |
2014-04-29 |
Time |
14:55 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
2014-04-29 |
Time |
09:46 |
Sent To |
|
|
| Notes |
| 2014-04-29 14:44:13 | INDICATE THE FAULT CURRENT CAPACITY REQUIRED FOR THE | | | ELECTRICAL SERVICE AND SWITCH GEAR. NEC 110.9, 110.10 | | | SPECIFICATIONS AND CUT SHEETS FOR THE ELEVATOR, | | | GENERATOR AND THE ATS IN ORDER TO DO A COMPLETE | | | ELECTRICAL REVIEW 110.3 | | | AN INTERSYSTEM BONDING STRIP IS REQUIRED AT THE MAIN | | | SERVICE GROUND. NEC 250.94 | | | A SIGN IS REQUIRED AT THE SERVICE ENTRANCE TO INDICATE | | | THE TYPE AND LOCATION OF THE OPTIONAL STANDBY SYSTEM. | | | 702 | | | EQUIPMENT GROUNDING CONDUCTORS IN PARALLEL TO BE FULL | | | SIZED 250.122 (F) PLANS DO NOT INDICATE AN EQUIPMENT | | | GROUND FROM THE GENERATOR AS REQUIRED 250.122. PLEASE | | | ADJUST THE RISER TO INDICATE A FULL SIZE EQUIPMENT | | | GROUNDING CONDUCTOR RUN WITH THE GENERATOR FEEDERS. | | | EQUIPMENT GROUNDING CONDUCTOR NOT REQUIRED AT SERVICE | | | ENTRANCE. PLEASE ADJUST THE RISER TO INDICATE ONLY THE | | | SERVICE ENTRANCE CONDUCTORS WITH THE NEUTRAL (GROUNDED | | | CONDUCTOR) AT THE 1ST MEANS OF DISCONNECT. AN EQUIPMENT | | | GOUNDING CONDUCTOR IS REQUIRED AFTER THE 1ST MEANS OF | | | DISCONNECT BUT NOT BEFORE. 250.6 & 250.24 | | | EQUIPMENT GOUNDING CONDUCTOR AT THE GENERATOR SHALL BE | | | BONDED TO THE GOUNDING ELECTRODE. 702.10.B | | | GAS SERVICE IS REQUIRED TO BE BONDED. 250.104.B. PLEASE | | | INCLUDE THE GAS SERVICE PIPING IN YOUR GROUNDING | | | ELECTRODE SYSTEM LINE DAGRAM. | | | RECESSED LIGHTING TO BE AIRTIGHT. FBC 402.5 PLEASE | | | INCLUDE A LIGHTING FIXTURE SCHEDULE AND CUT SHEETS FOR | | | RECESSED LIGHTING. | | | A MINIMUM OF 50% OF THE LIGHTING INSTALLED SHALL BE | | | ENERGY EFFICIENT. FBC 404.1 | | | AT LEAST ONE COUNTERTOP OUTLET IS REQUIRED AT THE | | | KITCHEN ISLAND. 210.52.C | | | THE ELEVATOR, GENERATOR, SWIMMING POOL, REQUIRES A | | | SEPARATE PERMIT. | | | | | | DAVID HAYES, ELECTRICAL PLANS EXAMINER. 561-805-6717, | | | [email protected]. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2014-03-31 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-04-01 |
Time |
10:15 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
2014-03-31 |
Time |
15:01 |
Sent To |
|
|
| Notes |
| 2014-03-31 15:08:55 | GENERATOR, SWIMMING POOL AND DOCK NOT INCLUDED IN THIS | | | PLAN REVIEW. ADDITIONAL DETAIL AND SUBMITTALS REQUIRED | | | PRIOR TO PROCESSING THOSE ITEMS FOR PERMIT. | | | PROTECTION FROM PHYSICAL DAMAGE TO BE PROVIDED FOR | | | ELECTRICAL PANELS IN GARAGE. NEC 110.27 B. | | | PUT IN R11 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2014-05-27 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-05-27 |
Time |
10:27 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2014-05-19 |
Time |
16:46 |
Sent To |
E |
|
| Notes |
| 2014-05-20 16:47:33 | TO DHAYSE DESK, SEND TO Z, LL THEREAFTER. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2014-05-06 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-05-06 |
Time |
17:44 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2014-04-10 |
Time |
18:59 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2014-04-01 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-04-01 |
Time |
10:16 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2014-02-12 |
Time |
06:40 |
Sent To |
|
|
| Notes |
| 2014-02-12 06:44:27 | INCOMING SENT TO R-11 BOX. JW |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
P |
Date |
2014-05-02 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-05-02 |
Time |
18:22 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2014-05-02 |
Time |
18:22 |
Sent To |
|
|
| Notes |
| 2014-05-02 18:23:53 | MU 2014 - 4814 |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2014-03-26 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-03-26 |
Time |
11:09 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2014-03-26 |
Time |
11:09 |
Sent To |
|
|
| Notes |
| 2014-03-26 11:14:16 | AN IMPACT FEE REVIEW BY PALM BEACH COUNTY IS REQUIRED. | | | AFTER THE PLANS HAVE BEEN APPROVED, ONE SET OF PLANS | | | CAN BE SIGNED OUT AND TAKEN TO PALM BEACH COUNTY FOR AN | | | IMPACT FEE REVIEW. THE PLANS WITH THE COUNTY IMPACT | | | REVIEW STAMP AND A COPY OF THE IMPACT FEE RECIEPT CAN | | | THEN BE RETURNED TO THE CITY BUILDING DEPARTMENT. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2014-05-02 |
|
|
Cont ID |
|
| Sent By |
RMCDOUGA |
Date |
2014-05-02 |
Time |
17:52 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2014-05-02 |
Time |
08:56 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2014-03-29 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-03-29 |
Time |
09:54 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2014-03-29 |
Time |
09:54 |
Sent To |
|
|
| Notes |
| 2014-03-29 10:23:21 | 2010 FBC | | | | | | DENIED BY MECHANICAL | | | | | | 1) SUBMIT TWO SETS OF MECHANICAL PLANS. SHOW EQUIPMENT | | | LOCATION AND DUCT SYSTEMS. SPECIFY ALL DUCT SIZES, | | | GRILL SIZES, CFMS AT EACH GRILL. CITY AMENDMENTS | | | 107.3.5 | | | | | | 2) SHOW COMPLIANCE WITH FBC M1602.4 FOR BALANCED RETURN | | | AIR. | | | | | | 3) SUBMIT TWO SETS OF HEATING AND COOLING EQUIPMENT | | | SIZING CALCULATIONS IN COMPLIANCE WITH FBCR M1401.3. | | | | | | 4) PROVIDE AN EQUIPMENT SCHEDULE ON THE MECHANICAL | | | PLANS THAT MATCHES THE EQUIPMENT SIZING CALCULATIONS. | | | CITY AMENDMENTS 107.2.1 | | | | | | 5) THE PRINTED NAME, SIGNATURE AND LICENSE NUMBER OF | | | THE PERSON RESPONSIBLE FOR THE DESIGN IS REQUIRED ON | | | THE PLANS. CITY AMENDMENTS 107.2.1 | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2014-03-26 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-03-26 |
Time |
13:41 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2014-03-26 |
Time |
11:09 |
Sent To |
|
|
| Notes |
| 2014-03-26 13:42:57 | RED-LINED PLUMBING RISER DIAGRAM TO ADD THE SECOND | | | FLOOR SINK THAT WAS MISSING. |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
P |
Date |
2014-05-27 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-05-27 |
Time |
14:53 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2014-05-27 |
Time |
14:53 |
Sent To |
|
|
| Notes |
| 2014-05-27 14:56:37 | ROOFING PRODUCT APPROVALS THAT WERE SUBMITTED. | | | | | | 1) ENGLERT METAL ROOFING, FL# 11727.3 R6 | | | 2) PECORA DECK 800 SERIES COATING SYSTEM, NOA NO. | | | 12-0308.27 | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2014-05-22 |
|
|
Cont ID |
|
| Sent By |
llouie |
Date |
2014-05-22 |
Time |
09:01 |
Rev Time |
0.00 |
| Received By |
llouie |
Date |
2014-05-22 |
Time |
09:01 |
Sent To |
B |
|
| Notes |
| 2014-05-22 09:03:30 | SEPARATE PERMITS AND REVIEWS REQUIRED FOR: GENERATOR, | | | POOL, FIRE PIT, NATURAL GAS, RETANING WALL, DRIVEWAY, | | | LANDSCAPING, AND FENCES AND SITE WALL. | | | | | | | | | | | | | | | | | 2014-05-21 11:20:36 | 5/21/14 ZONING RECEIVED SENT TO LL> SG | | 2014-05-20 16:48:30 | SEND TO RMCDOUGA LAST |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2014-04-18 |
|
|
Cont ID |
|
| Sent By |
LLOUIE |
Date |
2014-04-18 |
Time |
11:32 |
Rev Time |
0.00 |
| Received By |
llouie |
Date |
2014-04-18 |
Time |
11:32 |
Sent To |
|
|
| Notes |
| 2014-04-18 11:38:17 | ** FAILED ** | | | | | | PLEASE ADDRESS THE FOLLOWING COMMENTS. RESPOND TO THE | | | COMMENTS IN WRITING AND/OR ON THE PLANS WHERE | | | APPLICABLE: | | | | | | 1.) PURSUANT TO SECTION 94-306(A) OF THE ZONING AND | | | LAND DEVELOPMENT REGULATIONS, THE HEIGHT OF THE CHIMNEY | | | CANNOT EXCEED 10 PERCENT OF THE MAXIMUM ALLOWABLE | | | BUILDING HEIGHT OF THE DISTRICT (30 FT.). THE PROPOSED | | | CHIMNEY EXCEEDS THE 3 FT. HEIGHT LIMITATION ABOVE THE | | | 30 FT. MAXIMUM BUILDING HEIGHT. PLEASE ADDRESS. | | | | | | 2.) THE FOUNTAIN, LOCATED ALONG THE SOUTH PROPERTY | | | LINE, SHALL BE SETBACK AT LEAST 5 FT. FROM THE SIDE | | | PROPERTY LINE. (ZLDR S.94-304(B)(2)) | | | | | | 3.) THE EASEMENT CONSENT DOES NOT SPECIFY THE PROPOSED | | | STRUCTURES/IMPROVEMENTS WITHIN THE FPL EASEMENT. IT IS | | | NOT CLEAR TO WHETHER OR NOT FPL HAS ANY OBJECTIONS TO | | | THE PROPOSED STRUCTURES/IMPROVEMENTS WITHIN THEIR | | | UTILITY EASEMENT. | | | | | | 4.) REPEAT COMMENT: MECHANICAL EQUIPMENT, INCLUDING THE | | | GENERATOR, LOCATED ON THE SOUTH SIDE OF THE PROPERTY, | | | MAY NOT PROJECT MORE THAN 4 FT. INTO A SETBACK. (ZLDR | | | S.94-305(B)(4)) | | | | | | PLEASE NOTE THAT ANY CHANGES ON THE RESUBMITTED PLANS | | | MAY RESULT IN ADDITIONAL COMMENTS. CONTACT LINDA LOUIE | | | @ (561) 822-1458 IF YOU HAVE QUESTIONS. | | | | | | NOTES: | | | * LANDSCAPE PLAN MUST BE CONSISTENT WITH THE REVISIONS | | | TO THE SITE PLAN. | | | * SEPARATE PERMITS REQUIRED FOR: DRIVEWAY, SWIMMING | | | POOL, FIRE PIT, WALL/FENCE. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2014-02-20 |
|
|
Cont ID |
|
| Sent By |
llouie |
Date |
2014-02-20 |
Time |
10:31 |
Rev Time |
0.00 |
| Received By |
llouie |
Date |
2014-02-20 |
Time |
10:31 |
Sent To |
|
|
| Notes |
| 2014-02-20 10:35:34 | ** FAILED ** | | | | | | PLEASE ADDRESS THE FOLLOWING COMMENTS. RESPOND TO THE | | | COMMENTS IN WRITING AND/OR ON THE PLANS WHERE | | | APPLICABLE: | | | | | | 1.) THE SITE PLAN SHOWS A 10 FT. UTILITY EASEMENT ON | | | THE NORTH SIDE OF THE PROPERTY AND A 7 FT. 6-INCH | | | UTILITY EASEMENT ON THE SOUTH SIDE OF THE PROPERTY; | | | HOWEVER, THESE EASEMENTS ARE NOT SHOWN IN THE SURVEY. | | | ARE THESE EASEMENTS EXISTING OR PROPOSED, AND TO WHICH | | | PROVIDER DO THEY BELONG TO? PROVIDE DOCUMENTATION ON | | | THESE EASEMENTS. | | | | | | 2.) THE SITE PLAN SHOW PROPOSED STRUCTURES WITHIN THE | | | 10 FT. AND 7 FT. 6-INCHES UTILITY EASEMENTS. EASEMENT | | | CONSENT FROM THE UTILITY PROVIDER(S) IS NECESSARY IN | | | ORDER TO BUILD WITHIN THESE EASEMENTS. | | | | | | 3.) PLEASE IDENTIFY WHAT THE 4 FT. BY 4 FT. CONCRETE | | | PAD AT THE NORTHWEST CORNER OF THE PROPERTY WILL BE | | | UTILIZED FOR. | | | | | | 4.) THE MAXIMUM BUILDING HEIGHT IN THE SF7 RESIDENTIAL | | | ZONING DISTRICT IS 30 FT. THE PROPOSED RESIDENCE | | | EXCEEDS THIS MAXIMUM REQUIREMENT. (ZLDR S.94-72(A)(3)) | | | | | | 5.) MECHANICAL EQUIPMENT, INCLUDING THE CONCRETE PAD TO | | | WHICH THE EQUIPMENT WILL SIT ON, MAY NOT PROJECT MORE | | | THAN 4 FT. INTO A SETBACK. THE A/C EQUIPMENT ON THE | | | NORTH SIDE, AND THE A/C EQUIPMENT AND GENERATOR ON THE | | | SOUTH SIDE OF THE PROPERTY DOES NOT MEET THIS | | | REQUIREMENT. (ZLDR S.94-305(B)(4)) | | | | | | 6.) PROVIDE CLARIFICATION ON THE SQUARE ELEMENT IN THE | | | PROPOSED ATRIUM. THIS ELEMENT IS NOT VISIBLE ON ANY OF | | | THE PLANS, WITH EXCEPTION TO THE SITE PLAN (SHEET SP1). | | | | | | 7.) THE RETAINING WALL W/ FENCE ON TOP SHALL NOT EXCEED | | | 4 FT. IN HEIGHT WITHIN THE FIRST 25 FT. OF THE FRONT | | | LOT LINE. PLEASE DOCUMENT/ILLUSTRATE THAT THIS | | | REQUIREMENT IS MET. | | | | | | 8.) A LANDSCAPE PLAN IS REQUIRED FOR THIS PROJECT AND | | | SHALL BE SUBMITTED AND APPROVED BY A SEPARATE PERMIT. | | | (ZLDR S.94-441(B)) | | | | | | 9.) THE FOLLOWING LANDSCAPING REQUIREMENTS SHALL BE | | | ADDRESSED IN THE LANDSCAPE PLAN. INCLUDE ALL LANDSCAPE | | | CALCULATIONS TO ILLUSTRATE THAT THE PROJECT COMPLIES | | | WITH ZLDR, ARTICLE XIV : | | | | | | - AT LEAST ONE SHADE, FLOWERING OR FRUIT TREE SHALL BE | | | PLANTED FOR EACH 1,200 SQ. FT. OF OPEN SPACE OR PORTION | | | THEREOF. (ZLDR S.94-442(B)(2) A.) | | | | | | - AT LEAST ONE (1) SHRUB SHALL BE PLANTED FOR EACH 500 | | | SQ. FT. OF OPEN SPACE OR PORTION THEREOF. (ZLDR | | | S.94-442(B)(2) A.) | | | | | | 10.) THE FRONT YARD (MEASURED FROM THE FRONT BUILDING | | | FACADE TO THE PROPERTY LINE) SHALL HAVE A MINIMUM OF | | | 1,000 SQ. FT. OR 75 PERCENT OF LANDSCAPED AREA. (ZLDR | | | S. 94-482(A)) | | | | | | 11.) THERE SEEMS TO BE EXISTING TREES/PALMS ON THE | | | PROPERTY. PLEASE NOTE THAT A TREE ALTERATION PERMIT IS | | | REQUIRED PRIOR TO THE REMOVAL AND/OR RELOCATION OF ANY | | | TREE IN THE CITY. PLEASE SUBMIT AN APPLICATION FOR A | | | TREE ALTERATION PERMIT. | | | | | | 12.) A TREE ALTERATION PERMIT CAN BE OBTAINED ON THE | | | CITY'S WEBSITE FOLLOWING THIS PATH: | | | HTTP://WPB.ORG/PLANNING/WP | | | -CONTENT/UPLOADS/SITES/37/2013/04/TREEALTERATIONPERMITR | | | EVISED03-12-09.PDF | | | | | | PLEASE NOTE THAT ANY REVISIONS MAY RESULT IN ADDITIONAL | | | COMMENTS. CONTACT LINDA LOUIE @ (561) 822-1458 IF YOU | | | HAVE QUESTIONS. | | | | | 2014-02-18 15:11:57 | 2/18/14 |
|
|