| 2014-03-14 15:35:09 | PLEASE PROVIDE THE FOLLOWING INFORMATION PER |
| | FLORIDA BUILDING CODE 107.3.5.3 RESIDENTIAL (ONE AND |
| | TWO-FAMILY) |
| | DEMONSTRATE WHICH IMPROVEMENTS HAVE BEEN LEGALLY |
| | ESTABLISHED AND WHICH OTHER IMPROVEMENTS PROPOSED WITH |
| | THIS APPLICATION. PROVIDE ALL OF THE FOLLOWING OR |
| | INDICATE WHETHER EXISTING. |
| | 1. SITE REQUIREMENTS |
| | SET BACK/SEPARATION (ASSUMED PROPERTY LINES) |
| | LOCATION OF SEPTIC TANKS |
| | 2. FIRE-RESISTANT CONSTRUCTION (IF REQUIRED) |
| | 3. SMOKE DETECTOR LOCATIONS |
| | 4. EGRESS |
| | EGRESS WINDOW SIZE AND LOCATION STAIRS CONSTRUCTION |
| | REQUIREMENTS |
| | 5. STRUCTURAL REQUIREMENTS SHALL INCLUDE: |
| | WALL SECTION FROM FOUNDATION THROUGH ROOF, INCLUDING |
| | ASSEMBLY AND MATERIALS CONNECTOR |
| | TABLES |
| | TERMITE PROTECTION |
| | DESIGN LOADS |
| | WIND REQUIREMENTS |
| | BUILDING ENVELOPE |
| | STRUCTURAL CALCULATIONS (IF REQUIRED) |
| | FOUNDATION |
| | WALL SYSTEMS |
| | FLOOR SYSTEMS |
| | ROOF SYSTEMS |
| | 6. ACCESSIBILITY REQUIREMENTS: SHOW/IDENTIFY ACCESSIBLE |
| | BATH |
| | 7. IMPACT RESISTANT COVERINGS OR SYSTEMS |
| | 8. FLOOD HAZARD AREAS, FLOOD ZONES, DESIGN FLOOD |
| | ELEVATIONS, LOWEST FLOOR ELEVATIONS, |
| | ENCLOSURES, EQUIPMENT, AND FLOOD DAMAGE-RESISTANT |
| | MATERIALS |
| | 9. ELECTRICAL: |
| | ELECTRIC SERVICE RISER WITH WIRE SIZES, CONDUIT DETAIL |
| | AND GROUNDING DETAIL. COMPLETE |
| | LOAD CALCULATIONS, PANEL SCHEDULES |
| | 10.MECHANICAL: |
| | EQUIPMENT AND LOCATION, DUCT SYSTEMS |
| | 11.PLUMBING: |
| | PLUMBING RISER |
| | 12.GAS: |
| | GAS PIPING |
| | VENTING |
| | COMBUSTION AIR |
| | CHIMNEYS AND VENTS |
| | APPLIANCES |
| | TYPE OF GAS |
| | FIREPLACES |
| | LP TANK LOCATION |
| | RISER DIAGRAM/SHUTOFFS |
| | 13.ENERGY CALCULATIONS |
| | |
| | PLEASE NOTE: |
| | PLEASE BE ADVISED THE INSPECTOR MAY REQUIRE PREVIOUSLY |
| | COMPLETED WORK TO BE MADE ACCESSIBLE AND OPEN FOR |
| | INSPECTION OR REQUIRE ADDITIONAL DOCUMENTATION FOR ALL |
| | CONCEALED WORK PREVIOUSLY COMPLETED PURSUANT TO FBC 110 |
| | & FBC 117. |
| | |
| | FBC 110.1 GENERAL. CONSTRUCTION OR WORK FOR WHICH A |
| | PERMIT IS REQUIRED SHALL BE SUBJECT TO INSPECTION BY |
| | THE BUILDING OFFICIAL AND SUCH CONSTRUCTION OR WORK |
| | SHALL REMAIN ACCESSIBLE AND EXPOSED FOR INSPECTION |
| | PURPOSES UNTIL APPROVED. |
| | |
| | FBC 117 - THE BUILDING OFFICIAL MAY REQUIRE TESTS OR |
| | TEST REPORTS AS PROOF OF COMPLIANCE. REQUIRED TESTS ARE |
| | TO BE MADE AT THE EXPENSE OF THE OWNER, OR AGENT, BY AN |
| | APPROVED TESTING LABORATORY OR OTHER APPROVED AGENCY. |
| | |
| | STEVEN KENNEDY, CBO |
| | CHIEF PLANS EXAMINER |
| | (561) 805-6710 |
| | [email protected] |
| | |
| | |
| | |
| | |
| | |