Plan Review Details - Permit 14020305
Plan Review Stops For Permit 14020305
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2014-06-18 Cont ID  
Sent By S HILL Date 2014-06-18 Time 11:10 Rev Time 0.00
Received By jwitmer Date 2014-06-18 Time 10:54 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2014-02-26 Cont ID  
Sent By shill Date 2014-02-26 Time 18:35 Rev Time 0.00
Received By shill Date 2014-02-26 Time 18:35 Sent To  
Notes
2014-02-26 18:41:39****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 1. DOCUMENTS PREPARED BY AN ENGINEER AND SUBMITTED FOR
 PUBLIC RECORD ARE TO BE SIGNED, SEALED, DATED ORIGINALS
 AND ARE TO INCLUDE ALL INFORMATION FOR THE ENGINEER
 REQUIRED BY FAC61G15-23.002. IT IS NOT CLEAR WHICH OF
 THE VARIOUS COMPANY NAMES AND ADDRESSES ON THE PLAN ARE
 FOR THE ENGINEER. NO CERTIFICATE OF AUTHORIZATION
 NUMBER PROVIDED, AND THE ADDRESSES ON THE PLAN DO NOT
 MATCH DBPR RECORDS FOR THIS ENGINEER. PLEASE INCLUDE.
  
 2. FBC 107:
  
 ALL INFORMATION, DRAWINGS, SPECIFICATIONS AND
 ACCOMPANYING DATA SHALL BEAR THE NAME AND SIGNATURE OF
 THE PERSON RESPONSIBLE FOR THE DESIGN. (SEE ALSO
 SECTION 107.3.5).
  
 MANY SHEETS ARE NOT SIGNED AND SEALED AND ARE MARKED
 "INFORMATIONAL." SOME SHEETS HAVE FASTENING
 SPECIFICATIONS, SO THIS IS A DESIGN, NOT
 "INFORMATIONAL". PLEASE HAVE THE STRUCTURAL ENGINEER
 SIGN AND SEAL ANY SHEETS WITH STRUCTURAL
 SPECIFICATIONS. FOR EXAMPLE, A11, ITEM 5.
  
 3. FASTENING SPECIFICATIONS FOR ALL COMPONENTS REQUIRED
 TO BE COMPLETE - NUMBER OF FASTENERS, TYPE OF FASTENER,
 DIAMETER, MINIMUM EMBEDMENT IF APPLICABLE. FBC 1609.
  
 4. WIND DESIGN CRITERIA REQUIRED TO BE ON THE PLAN, FBC
 1603.1.4.
  
 5. SOME SHEETS ARE NOT LEGIBLE; FOR INSTANCE, DETAIL 6
 ON SHEET A4. PRIOR TO RESUBMITTAL, CONFIRM THAT ALL
 INFORMATION ON THE PLANS ARE LEGIBLE. IF THE
 INFORMATION IS NOT REQUIRED, REMOVE FROM THE PLAN, FBC
 107.
  
 6. CABINETS ARE SHOWN AS PROPOSED. PROVIDE DCA APPROVAL
 OR ENGINEERING FOR CABINETS, FBC 1609.
  
  

Review Stop E ELECTRICAL
Rev No 2 Status N Date 2014-07-22 Cont ID  
Sent By swierzko Date 2014-07-22 Time 07:45 Rev Time 0.00
Received By swierzko Date 2014-07-21 Time 16:33 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2014-03-18 Cont ID  
Sent By rlecky Date 2014-03-18 Time 11:15 Rev Time 0.00
Received By rlecky Date 2014-03-18 Time 10:59 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2014-07-22 Cont ID  
Sent By swierzko Date 2014-07-22 Time 08:12 Rev Time 0.00
Received By swierzko Date 2014-06-03 Time 09:17 Sent To  
Notes
2014-06-04 09:15:48B11

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2014-03-18 Cont ID  
Sent By rlecky Date 2014-03-18 Time 11:15 Rev Time 0.00
Received By rlecky Date 2014-02-07 Time 15:22 Sent To  
Notes
2014-02-07 15:22:40B02
  
  

Review Stop Z ZONING
Rev No 2 Status F Date 2014-06-09 Cont ID  
Sent By LLOUIE Date 2014-06-09 Time 16:02 Rev Time 0.00
Received By llouie Date 2014-06-09 Time 16:02 Sent To  
Notes
2014-06-09 16:03:06** FAILED **
  
 PLEASE ADDRESS THE FOLLOWING COMMENTS. RESPOND TO THE
 COMMENTS IN WRITING AND/OR ON THE PLANS WHERE
 APPLICABLE:
  
 1.) REPEAT COMMENT FROM 2/11/2014: ANY CHANGES TO THE
 APPROVED PLANS REQUIRE ADDITIONAL REVIEW AND APPROVAL
 FROM THE PLANNING DIVISION PRIOR TO BUILDING PERMIT.
 (REFERENCE APPROVAL: WCF #12-13)
  
 2.) REPEAT COMMENT FROM 2/11/2014: THE PLANNING
 DIVISION APPLICATION FOR IMPROVEMENTS TO A WIRELESS
 COMMUNICATION FACILITY CAN BE OBTAINED FOLLOWING THIS
 LINK: HTTP://WPB.ORG/PLANNIN
 G/WP-CONTENT/UPLOADS/SITES/37/2013/04/2013-WIRELESS-DEV
 ELOPMENT-APPLICATION-REVISED-06.19.2013.PDF
  
 PLEASE NOTE THAT ANY CHANGES ON THE RESUBMITTED PLANS
 MAY RESULT IN ADDITIONAL COMMENTS. CONTACT LINDA LOUIE
 @ (561) 822-1458 IF YOU HAVE QUESTIONS.
  

Review Stop Z ZONING
Rev No 1 Status F Date 2014-02-11 Cont ID  
Sent By llouie Date 2014-02-11 Time 14:35 Rev Time 0.00
Received By llouie Date 2014-02-11 Time 14:35 Sent To  
Notes
2014-02-11 14:36:02** FAILED **
  
 PLEASE ADDRESS THE FOLLOWING COMMENTS. RESPOND TO THE
 COMMENTS IN WRITING AND/OR ON THE PLANS WHERE
 APPLICABLE:
  
 ANY IMPROVEMENTS TO A WIRELESS COMMUNICATION FACILITY
 MUST BE REVIEWED AND APPROVED BY THE PLANNING DIVISION
 PRIOR TO BUILDING PERMIT. (ZLDR S.94-314)
  
 THE PLANNING DIVISION APPLICATION FOR IMPROVEMENTS TO A
 WIRELESS COMMUNICATION FACILITY CAN BE OBTAINED
 FOLLOWING THIS LINK: HTTP://WPB.ORG/PLANNIN
 G/WP-CONTENT/UPLOADS/SITES/37/2013/04/2013-WIRELESS-DEV
 ELOPMENT-APPLICATION-REVISED-06.19.2013.PDF
  
 PLEASE NOTE THAT ANY REVISIONS MAY RESULT IN ADDITIONAL
 COMMENTS. CONTACT LINDA LOUIE @ (561) 822-1458 IF YOU
 HAVE QUESTIONS.
  
2014-02-10 16:34:072/10/14


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved