 |
Plan Review Details - Permit 14020179
| Plan Review Stops For Permit 14020179 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
6 |
Status |
P |
Date |
2015-02-05 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2015-02-05 |
Time |
15:39 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2015-02-05 |
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
F |
Date |
2015-01-06 |
|
|
Cont ID |
|
| Sent By |
JWITMER |
Date |
2015-01-06 |
Time |
08:35 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2015-01-06 |
Time |
07:30 |
Sent To |
|
|
| Notes |
| 2015-01-06 08:19:37 | BUILDING PLAN REVIEW | | | PERMIT: 14020179 | | | PCN: 00-42-43-24-00-000-5251 | | | P. B. C. TO BE ANNEXED | | | ADD: 2132 INDIAN RD | | | CONT: CREATIVE CONTRACTING GROUP | | | TEL: (561)333-1445 | | | | | | 2010 FLORIDA BUILDING CODE W | | | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | | | NOTICE:!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!! | | | !!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!! | | | !!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!! | | | CHAPTER 553.80(2)(B) FLORIDA STATUTES STATES THAT A | | | LOCAL GOVERNMENT SHALL IMPOSE A FEE OF FOUR TIMES THE | | | FEE FOR | | | PLAN REVIEW, IF PLANS ARE REJECTED (3) OR MORE TIMES | | | FOR REPEATED FAILURE TO CORRECT A CODE VIOLATION. | | | | | | 5TH REVIEW | | | DATE: TUES. JAN. 06/ 2015 | | | ACTION: DENIED | | | | | | 1) ADDRESS/ COMPLIED. | | | | | | 2) COMPLIED. | | | | | | 3) COMPLIED. SOILS REPORT. | | | | | | 4) COMPLIED. WIND EXPOSURE. | | | | | | 5) 5TH REQUEST. 2010 FBC-B 1609.1.2 PROTECTION OF | | | OPENINGS, 1609.6.4.41 COMPONENTS & CLADDING | | | FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS RULE 9N-3 NOV. | | | 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION | | | SYSTEMS THAT WILL REQUIRE PRODUCT APPROVALS: | | | | | | (31)(C) WALL PANELS. | | | | | | (31)(D) ROOFING PANELS. NOTE A SINGLE COPY OF A ROOFING | | | NOA 12-0716.16 WAS SUBMITTED, WHY WOULD A MODIFIED | | | BITUMEN ROOFING PRODUCT BE PUT ON A STRUCTURAL STEEL | | | PANEL ROOF. | | | | | | 6A) 5TH REQUEST. THE NEW STEEL BUILDING PLANS BY LUDWIG | | | WILL NEED TO PROVIDE PRODUCT APPROVALS FOR THE WALL | | | PANELS AND ROOFING SYSTEMS. 107.3.4.1 PRODUCT | | | APPROVALS. THOSE PRODUCTS WHICH ARE REGULATED BY THE | | | DCA RULE 9N-03 SHALL BE REVIEWED AND APPROVED IN | | | WRITING BY THE DESIGNER OF RECORD PRIOR TO SUBMITTAL | | | FOR JURISDICTIONAL APPROVAL. FL 61G1-23.015 (2) THE | | | ARCHITECT IS RESPONSIBLE FOR SUPERVISING AND REVIEWING | | | ALL PROJECT DATA, REPORTS, SHOP DRAWINGS ETC.. | | | | | | 6B) 5TH REQUEST. THE LUDWIG STEEL BUILDING PLANS ARE ON | | | 8 1/2 X 11 SHEETS OF PAPER, THEY DO NOT MEET THE | | | REQUIRED SIZE REQUIREMENTS FOR RECORD RETENTION. | | | 107.2.1.4 QUALITY OF BUILDING PLANS. BUILDING PLANS | | | SHALL BE DRAWN TO A MINIMUM 1/8 INCH SCALE UPON | | | SUBSTANTIAL PAPER, CLOTH OR OTHER ACCEPTABLE MEDIUM. | | | THE BUILDING OFFICIAL MAY ESTABLISH THROUGH | | | DEPARTMENTAL POLICY, OTHER STANDARDS FOR PLANS AND | | | SPECIFICATIONS, IN | | | ORDER TO PROVIDE CONFORMITY TO ITS RECORD RETENTION | | | PROGRAM. THIS POLICY MAY INCLUDE SUCH THINGS AS MINIMUM | | | SIZE, SHAPE, CONTRAST, CLARITY, OR OTHER ITEMS RELATED | | | TO RECORDS MANAGEMENT. | | | | | | 6C) 5TH REQUEST. WITH THE REDUCED SIZE OF THE ENGINEERS | | | SEAL THE PLANS DO NNOT MEET THE SEAL REQUIREMETS. | | | 61G15-23.001 SEALS ACCEPTABLE TO THE BOARD. SAID SEAL | | | SHALL BE A MINIMUM OF 1 7/8 INCHES IN DIAMETER, TO SAY | | | LICENSE NOT CERTIFICATE. ALL ENGINEERS MUST BE | | | UTILIZING SAID SEAL NO LATER THAN JANUARY 1, 2006. | | | | | | 7) 5TH REQUEST. SHEET S-6 & S-10 BOTH INDICATE THE USE | | | OF HELICAL PILES PER COLUMN, IS THERE A SUPPORTING | | | SOILS REPORT/ 2010 FBC-B 1803.5.2 QUESTIONABLE SOIL. | | | WHERE THE CLASSIFICATION, STRENGTH OR COMPRESSIBILITY | | | OF THE SOIL IS IN DOUBT OR WHERE A LOAD-BEARING VALUE | | | SUPERIOR TO THAT SPECIFIED IN THIS CODE IS CLAIMED, THE | | | BUILDING OFFICIAL SHALL BE PERMITTED TO REQUIRE THAT A | | | GEOTECHNICAL INVESTIGATION BE CONDUCTED. NO PRODUCT | | | INFORMATION FOR THE HELICAL PIERS SHEET S-10 DETAIL # 1 | | | INDICATES THE USE OF HELICAL PILE WHERE AS DETAIL 2 & 3 | | | BOTH LOOK LIKE AUGER PILE. 107.2.1.3 ADDITIONAL | | | INFORMATION IS REQUIRED. NO COMMENT RESPONCE FOR THIS | | | REQUEST. | | | | | | 8) 5TH REQUEST. BEFORE A PERMIT TO CONSTRUCT, MAY BE | | | ISSUED, IMPACT FEES MUST BE PAID TO PALM BEACH COUNTY. | | | THE ACTUAL PERMIT SET OF PLANS MUST BE STAMPED BY THAT | | | OFFICE, AND A COPY OF THE PAID RECEIPT ATTACHED TO THE | | | PERMIT APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | 9) 5 TH REQUEST. WHEN RESUBMITTING PLANS PLEASE | | | INDICATE THE REVISION & REMOVE & REPLACE ANY PAGES AS | | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2014-11-24 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2014-11-24 |
Time |
12:54 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-11-24 |
Time |
11:51 |
Sent To |
|
|
| Notes |
| 2014-11-24 12:54:37 | BUILDING PLAN REVIEW | | | PERMIT: 14020179 | | | PCN: 00-42-43-24-00-000-5251 | | | P. B. C. TO BE ANNEXED | | | ADD: 2132 INDIAN RD | | | CONT: CREATIVE CONTRACTING GROUP | | | TEL: (561)333-1445 | | | | | | 2010 FLORIDA BUILDING CODE W | | | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | | | NOTICE:!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!! | | | !!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!! | | | !!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!! | | | CHAPTER 553.80(2)(B) FLORIDA STATUTES STATES THAT A | | | LOCAL GOVERNMENT SHALL IMPOSE A FEE OF FOUR TIMES THE | | | FEE FOR | | | PLAN REVIEW, IF PLANS ARE REJECTED (3) OR MORE TIMES | | | FOR REPEATED FAILURE TO CORRECT A CODE VIOLATION. | | | | | | 4TH REVIEW | | | DATE: TUES. NOV. 224/ 2014 | | | ACTION: DENIED | | | | | | 1) ADDRESS/ COMPLIED. | | | | | | 2) 4TH REQUEST. THIS SITE IS BEING ANNEXED INTO THE | | | CITY, IT IS LOCATED WITHIN AN A8 FLOOD ZONE. THE | | | MINIMUM BASE FLOOD ELEVATION IS 16.00 FT NGVD THE CITY | | | OF WEST PALM BEACH REQUIRES AN ADDITIONAL 6 INCHES TO | | | THE BASE FLOOD OR A FINISH FLOOR OF 16.5 FT NGVD. | | | THE SURVEY INDICATES A FINISH FLOOR OF 16.53 NGVD. | | | | | | 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING | | | CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | | 107.3.5 MINIMUM PLAN REVIEW CRITERIA FOR BUILDINGS. | | | 107.3.5.1 COMMERCIAL BUILDINGS: | | | 107.3.5.1.1. BUILDING | | | 107.3.5.1.1.SITE REQUIREMENTS: FLOOD HAZARD AREAS, | | | FLOOD ZONES, AND DESIGN FLOOD ELEVATIONS PROVIDE WHAT | | | THE EXISTING FINISH FLOOR ELEVATION IS IN NDVD. | | | PLEASE PROVIDE A CURRENT SURVEY SIGNED AND SEALED (2) | | | ORIGINALS & FLOOD ZONE CERTIFICATES, THIS STRUCTURE IS | | | LOCATED IN A A8 FLOOD ZONE WITH A REQUIRED 16.00 ELE. | | | NGVD. THE CITY MUNI CODE FLOOD PREVENTION AND CONTROL | | | REQUIRES AN ADDITIONAL 6 INCH FREE BOARD FOR | | | RESIDENTIAL AND FOR COMMERCIAL FLOOD PROOFING FOR THE | | | SAME 6 INCHES PLUS A ADDITIONAL 6 INCHES IF FLOOD | | | PROOFING AND THE FLOOR NOT BEING ABOVE 16.5 FT. NGVD. | | | FBC BUILDING 3110.1.2 / CITY OF WPB CODE OF ORDINANCES | | | SECTION 94-546. STRUCTURE IS LOCATED IN AN "A" FLOOD | | | ZONE. A FLOOD ELEVATION CERTIFICATE WILL BE REQUIRED. | | | PLEASE REVIEW CITY ORDINANCE FOR THE CITY REQUIREMENTS | | | REQUIRE AN ADDITIONAL 6 INCHES OF ELEVATION | | | | | | NEW COMMENT: PLEASE BE AWARE : THE 2010 FBC-B 1612.4 | | | DESIGN AND CONSTRUCTION. | | | THE DESIGN AND CONSTRUCTION OF BUILDINGS AND STRUCTURES | | | LOCATED IN FLOOD HAZARD AREAS, INCLUDING FLOOD HAZARD | | | AREAS SUBJECT TO HIGH-VELOCITY WAVE ACTION, SHALL BE IN | | | ACCORDANCE WITH CHAPTER 5 OF ASCE 7 AND WITH ASCE | | | 24.TABLE 7.1 REQUIRES A 1 FT. HEIGHT FOR FINISH FLOOR | | | ABOVE THE BASE FLOOD ELEVATION FOR A BUILDING CATEGORY | | | II. | | | | | | | | | DURING THE PERMITTING OF THIS STRUCTURE THERE WILL BE | | | REQUIRED (3) DIFFERENT FLOOD ZONE CERTIFICATES | | | REQUIRED: | | | (1) A FLOOD ZONE CERTIFICATE IS REQUIRED AS PART OF THE | | | PLAN REVIEW DOCUMENTS WITH THE PROPOSED FINISH FLOOR | | | HEIGHT. | | | (2) ONCE THE FIRST FLOOR SLAB IS POURED THE 2ND | | | ELEVATION CERTIFICATE IS REQUIRED | | | (3) BEFORE THE ISSUANCE OF A CERTIFICATE OF OCCUPANCY | | | OR A CERTIFICATE OF COMPLETION THE 3RD FLOOD ZONE | | | CERTIFICATE IS REQUIRED WITH THE HEIGHT OF ALL EXTERIOR | | | ATTENDANT | | | A/C PADS OR OTHER SLABS FOR GENERATORS | | | | | | FEMA FORM OMB NO. 1660-0008 EXPIRES: | | | JULY 31,2015 | | | | | | FEMA'S NEW ELEVATION CERTIFICATE (EC) WAS APPROVED FOR | | | USE, EFFECTIVE AUGUST 1/ 2013, THROUGH JULY 31/ 2015. | | | | | | 2) SHEET S-2 SEMI-COMPLIED. THE PREVIOUS REVIEW THE | | | PLAN REVIEWER STATED THIS TO BE A S2 OCCUPANCY. FOR | | | AUTO REPAIR GAGARES AND BULK TIRE STORAGE WE ARE LOKING | | | AT A S-1 OCCUPANCY SEE THE 2010 FBC-B 311.2. THE | | | OCCUPANCY LOADING WOULD BE 300 GSF / 12 OCCUPANTS. | | | | | | 3) 4TH REQUEST. STRUCTURAL REQUIREMENTS SHALL INCLUDE: | | | SOIL CONDITIONS/ANALYSIS- MISSING | | | 2010 FBC-B 1803.5.2 QUESTIONABLE SOIL. | | | WHERE THE CLASSIFICATION, STRENGTH OR COMPRESSIBILITY | | | OF THE SOIL IS IN DOUBT OR WHERE A LOAD-BEARING VALUE | | | SUPERIOR TO THAT SPECIFIED IN THIS CODE IS CLAIMED, THE | | | BUILDING OFFICIAL SHALL BE PERMITTED TO REQUIRE THAT A | | | GEOTECHNICAL INVESTIGATION BE CONDUCTED. | | | 1803.6 REPORTING. | | | WHERE GEOTECHNICAL INVESTIGATIONS ARE REQUIRED, A | | | WRITTEN REPORT OF THE INVESTIGATIONS SHALL BE SUBMITTED | | | TO THE BUILDING OFFICIAL BY THE OWNER OR AUTHORIZED | | | AGENT AT THE TIME OF PERMIT APPLICATION | | | | | | 4) 4TH REQUEST. ENGINEERED PLANS FROM DERIK SCHENAVAR | | | INDICATE A "C" EXPOSURE BUT THE NEW LUDWIG STEEL | | | BUILDING PLANS INDICATE A "B" EXPOSURE. | | | | | | 5) 4TH REQUEST. 2010 FBC-B 1609.1.2 PROTECTION OF | | | OPENINGS, 1609.6.4.41 COMPONENTS & CLADDING | | | FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS RULE 9N-3 NOV. | | | 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION | | | SYSTEMS THAT WILL REQUIRE PRODUCT APPROVALS: | | | | | | (31)(C) WALL PANELS. | | | | | | (31)(D) ROOFING PANELS. | | | | | | 6A) 4TH REQUEST. THE NEW STEEL BUILDING PLANS BY LUDWIG | | | WILL NEED TO PROVIDE PRODUCT APPROVALS FOR THE WALL | | | PANELS AND ROOFING SYSTEMS. 107.3.4.1 PRODUCT | | | APPROVALS. THOSE PRODUCTS WHICH ARE REGULATED BY THE | | | DCA RULE 9N-03 SHALL BE REVIEWED AND APPROVED IN | | | WRITING BY THE DESIGNER OF RECORD PRIOR TO SUBMITTAL | | | FOR JURISDICTIONAL APPROVAL. FL 61G1-23.015 (2) THE | | | ARCHITECT IS RESPONSIBLE FOR SUPERVISING AND REVIEWING | | | ALL PROJECT DATA, REPORTS, SHOP DRAWINGS ETC.. | | | | | | 6B) 4TH REQUEST. THE LUDWIG STEEL BUILDING PLANS ARE ON | | | 8 1/2 X 11 SHEETS OF PAPER, THEY DO NOT MEET THE | | | REQUIRED SIZE REQUIREMENTS FOR RECORD RETENTION. | | | 107.2.1.4 QUALITY OF BUILDING PLANS. BUILDING PLANS | | | SHALL BE DRAWN TO A MINIMUM 1/8 INCH SCALE UPON | | | SUBSTANTIAL PAPER, CLOTH OR OTHER ACCEPTABLE MEDIUM. | | | THE BUILDING OFFICIAL MAY ESTABLISH THROUGH | | | DEPARTMENTAL POLICY, OTHER STANDARDS FOR PLANS AND | | | SPECIFICATIONS, IN | | | ORDER TO PROVIDE CONFORMITY TO ITS RECORD RETENTION | | | PROGRAM. THIS POLICY MAY INCLUDE SUCH THINGS AS MINIMUM | | | SIZE, SHAPE, CONTRAST, CLARITY, OR OTHER ITEMS RELATED | | | TO RECORDS MANAGEMENT. | | | | | | 6C) 4TH REQUEST. WITH THE REDUCED SIZE OF THE ENGINEERS | | | SEAL THE PLANS DO NNOT MEET THE SEAL REQUIREMETS. | | | 61G15-23.001 SEALS ACCEPTABLE TO THE BOARD. SAID SEAL | | | SHALL BE A MINIMUM OF 1 7/8 INCHES IN DIAMETER, TO SAY | | | LICENSE NOT CERTIFICATE. ALL ENGINEERS MUST BE | | | UTILIZING SAID SEAL NO LATER THAN JANUARY 1, 2006. | | | | | | 7) 4TH REQUEST. SHEET S-6 & S-10 BOTH INDICATE THE USE | | | OF HELICAL PILES PER COLUMN, IS THERE A SUPPORTING | | | SOILS REPORT/ 2010 FBC-B 1803.5.2 QUESTIONABLE SOIL. | | | WHERE THE CLASSIFICATION, STRENGTH OR COMPRESSIBILITY | | | OF THE SOIL IS IN DOUBT OR WHERE A LOAD-BEARING VALUE | | | SUPERIOR TO THAT SPECIFIED IN THIS CODE IS CLAIMED, THE | | | BUILDING OFFICIAL SHALL BE PERMITTED TO REQUIRE THAT A | | | GEOTECHNICAL INVESTIGATION BE CONDUCTED. NO PRODUCT | | | INFORMATION FOR THE HELICAL PIERS SHEET S-10 DETAIL # 1 | | | INDICATES THE USE OF HELICAL PILE WHERE AS DETAIL 2 & 3 | | | OTH LOOK LIKE AUGER PILE. 107.2.1.3 ADDITIONAL | | | INFORMATION IS REQUIRED. | | | | | | 8) 4TH REQUEST. BEFORE A PERMIT TO CONSTRUCT, MAY BE | | | ISSUED, IMPACT FEES MUST BE PAID TO PALM BEACH COUNTY. | | | THE ACTUAL PERMIT SET OF PLANS MUST BE STAMPED BY THAT | | | OFFICE, AND A COPY OF THE PAID RECEIPT ATTACHED TO THE | | | PERMIT APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | 9) 4TH REQUEST. WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY PAGES AS NECESSARY. | | | A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW | | | COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | | THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR | | | PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2014-09-23 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2014-09-23 |
Time |
14:23 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-09-23 |
Time |
12:02 |
Sent To |
|
|
| Notes |
| 2014-09-23 12:23:02 | BUILDING PLAN REVIEW | | | PERMIT: 14020179 | | | PCN: 00-42-43-24-00-000-5251 | | | P. B. C. TO BE ANNEXED | | | ADD: 2132 INDIAN RD | | | CONT: CREATIVE CONTRACTING GROUP | | | TEL: (561)333-1445 | | | | | | 2010 FLORIDA BUILDING CODE W | | | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | | | 2010 EXISTING BUILDING CODE LEVEL II 701.3 | | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | | | NOTICE:!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!! | | | !!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!! | | | !!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!! | | | CHAPTER 553.80(2)(B) FLORIDA STATUTES STATES THAT A | | | LOCAL GOVERNMENT SHALL IMPOSE A FEE OF FOUR TIMES THE | | | FEE FOR | | | PLAN REVIEW, IF PLANS ARE REJECTED (3) OR MORE TIMES | | | FOR REPEATED FAILURE TO CORRECT A CODE VIOLATION. | | | | | | 3RD REVIEW | | | DATE: TUES. SEPT. 23/ 2014 | | | ACTION: DENIED | | | | | | 1) ADDRESS/ COMPLIED. | | | | | | 2) 3RD REQUEST. THIS SITE IS BEING ANNEXED INTO THE | | | CITY, IT IS LOCATED WITHIN AN A8 FLOOD ZONE. THE | | | MINIMUM BASE FLOOD ELEVATION IS 16.00 FT NGVD THE CITY | | | OF WEST PALM BEACH REQUIRES AN ADDITIONAL 6 INCHES TO | | | THE BASE FLOOD OR A FINISH FLOOR OF 16.5 FT NGVD. | | | THE SURVEY INDICATES A FINISH FLOOR OF 16.53 NGVD. | | | | | | 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING | | | CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | | 107.3.5 MINIMUM PLAN REVIEW CRITERIA FOR BUILDINGS. | | | 107.3.5.1 COMMERCIAL BUILDINGS: | | | 107.3.5.1.1. BUILDING | | | 107.3.5.1.1.SITE REQUIREMENTS: FLOOD HAZARD AREAS, | | | FLOOD ZONES, AND DESIGN FLOOD ELEVATIONS PROVIDE WHAT | | | THE EXISTING FINISH FLOOR ELEVATION IS IN NDVD. | | | PLEASE PROVIDE A CURRENT SURVEY SIGNED AND SEALED (2) | | | ORIGINALS & FLOOD ZONE CERTIFICATES, THIS STRUCTURE IS | | | LOCATED IN A A8 FLOOD ZONE WITH A REQUIRED 16.00 ELE. | | | NGVD. THE CITY MUNI CODE FLOOD PREVENTION AND CONTROL | | | REQUIRES AN ADDITIONAL 6 INCH FREE BOARD FOR | | | RESIDENTIAL AND FOR COMMERCIAL FLOOD PROOFING FOR THE | | | SAME 6 INCHES PLUS A ADDITIONAL 6 INCHES IF FLOOD | | | PROOFING AND THE FLOOR NOT BEING ABOVE 16.5 FT. NGVD. | | | FBC BUILDING 3110.1.2 / CITY OF WPB CODE OF ORDINANCES | | | SECTION 94-546. STRUCTURE IS LOCATED IN AN "A" FLOOD | | | ZONE. A FLOOD ELEVATION CERTIFICATE WILL BE REQUIRED. | | | PLEASE REVIEW CITY ORDINANCE FOR THE CITY REQUIREMENTS | | | REQUIRE AN ADDITIONAL 6 INCHES OF ELEVATION | | | | | | DURING THE PERMITTING OF THIS STRUCTURE THERE WILL BE | | | REQUIRED (3) DIFFERENT FLOOD ZONE CERTIFICATES | | | REQUIRED: | | | (1) A FLOOD ZONE CERTIFICATE IS REQUIRED AS PART OF THE | | | PLAN REVIEW DOCUMENTS WITH THE PROPOSED FINISH FLOOR | | | HEIGHT. | | | (2) ONCE THE FIRST FLOOR SLAB IS POURED THE 2ND | | | ELEVATION CERTIFICATE IS REQUIRED | | | (3) BEFORE THE ISSUANCE OF A CERTIFICATE OF OCCUPANCY | | | OR A CERTIFICATE OF COMPLETION THE 3RD FLOOD ZONE | | | CERTIFICATE IS REQUIRED WITH THE HEIGHT OF ALL EXTERIOR | | | ATTENDANT | | | A/C PADS OR OTHER SLABS FOR GENERATORS | | | | | | FEMA FORM OMB NO. 1660-0008 EXPIRES: | | | JULY 31,2015 | | | | | | FEMA'S NEW ELEVATION CERTIFICATE (EC) WAS APPROVED FOR | | | USE, EFFECTIVE AUGUST 1/ 2013, THROUGH JULY 31/ 2015. | | | | | | 2) SHEET S-2 SEMI-COMPLIED. THE PREVIOUS REVIEW THE | | | PLAN REVIEWER STATED THIS TO BE A S2 OCCUPANCY. FOR | | | AUTO REPAIR GAGARES AND BULK TIRE STORAGE WE ARE LOKING | | | AT A S-1 OCCUPANCY SEE THE 2010 FBC-B 311.2. THE | | | OCCUPANCY LOADING WOULD BE 300 GSF / 12 OCCUPANTS. | | | | | | 3) 3RD REQUEST. STRUCTURAL REQUIREMENTS SHALL INCLUDE: | | | SOIL CONDITIONS/ANALYSIS- MISSING | | | 2010 FBC-B 1803.5.2 QUESTIONABLE SOIL. | | | WHERE THE CLASSIFICATION, STRENGTH OR COMPRESSIBILITY | | | OF THE SOIL IS IN DOUBT OR WHERE A LOAD-BEARING VALUE | | | SUPERIOR TO THAT SPECIFIED IN THIS CODE IS CLAIMED, THE | | | BUILDING OFFICIAL SHALL BE PERMITTED TO REQUIRE THAT A | | | GEOTECHNICAL INVESTIGATION BE CONDUCTED. | | | 1803.6 REPORTING. | | | WHERE GEOTECHNICAL INVESTIGATIONS ARE REQUIRED, A | | | WRITTEN REPORT OF THE INVESTIGATIONS SHALL BE SUBMITTED | | | TO THE BUILDING OFFICIAL BY THE OWNER OR AUTHORIZED | | | AGENT AT THE TIME OF PERMIT APPLICATION | | | | | | 4) SEMI -COMPLIED. ENGINEERED PLANS FROM DERIK | | | SCHENAVAR INDICATE A "C" EXPOSURE BUT THE NEW LUDWIG | | | STEEL BUILDING PLANS INDICATE A "B" EXPOSURE. | | | | | | 5) 2010 FBC-B 1609.1.2 PROTECTION OF OPENINGS, | | | 1609.6.4.41 COMPONENTS & CLADDING | | | FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS RULE 9N-3 NOV. | | | 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION | | | SYSTEMS THAT WILL REQUIRE PRODUCT APPROVALS: | | | | | | (31)(C) WALL PANELS. | | | | | | (31)(D) ROOFING PANELS. | | | | | | 6A) THE NEW STEEL BUILDING PLANS BY LUDWIG WILL NEED TO | | | PROVIDE PRODUCT APPROVALS FOR THE WALL PANELS AND | | | ROOFING SYSTEMS. 107.3.4.1 PRODUCT APPROVALS. THOSE | | | PRODUCTS WHICH ARE REGULATED BY THE DCA RULE 9N-03 | | | SHALL BE REVIEWED AND APPROVED IN WRITING BY THE | | | DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR | | | JURISDICTIONAL APPROVAL. FL 61G1-23.015 (2) THE | | | ARCHITECT IS RESPONSIBLE FOR SUPERVISING AND REVIEWING | | | ALL PROJECT DATA, REPORTS, SHOP DRAWINGS ETC.. | | | | | | 6B) THE LUDWIG STEEL BUILDING PLANS ARE ON 8 1/2 X 11 | | | SHEETS OF PAPER, THEY DO NOT MEET THE REQUIRED SIZE | | | REQUIREMENTS FOR RECORD RETENTION. | | | 107.2.1.4 QUALITY OF BUILDING PLANS. BUILDING PLANS | | | SHALL BE DRAWN TO A MINIMUM 1/8 INCH SCALE UPON | | | SUBSTANTIAL PAPER, CLOTH OR OTHER ACCEPTABLE MEDIUM. | | | THE BUILDING OFFICIAL MAY ESTABLISH THROUGH | | | DEPARTMENTAL POLICY, OTHER STANDARDS FOR PLANS AND | | | SPECIFICATIONS, IN | | | ORDER TO PROVIDE CONFORMITY TO ITS RECORD RETENTION | | | PROGRAM. THIS POLICY MAY INCLUDE SUCH THINGS AS MINIMUM | | | SIZE, SHAPE, CONTRAST, CLARITY, OR OTHER ITEMS RELATED | | | TO RECORDS MANAGEMENT. | | | | | | 6C) WITH THE REDUCED SIZE OF THE ENGINEERS SEAL THE | | | PLANS DO NNOT MEET THE SEAL REQUIREMETS. 61G15-23.001 | | | SEALS ACCEPTABLE TO THE BOARD. SAID SEAL SHALL BE A | | | MINIMUM OF 1 7/8 INCHES IN DIAMETER, TO SAY LICENSE NOT | | | CERTIFICATE. ALL ENGINEERS MUST BE UTILIZING SAID SEAL | | | NO LATER THAN JANUARY 1, 2006. | | | | | | 7) SHEET S-6 & S-10 BOTH INDICATE THE USE OF HELICAL | | | PILES PER COLUMN, IS THERE A SUPPORTING SOILS REPORT/ | | | 2010 FBC-B 1803.5.2 QUESTIONABLE SOIL. WHERE THE | | | CLASSIFICATION, STRENGTH OR COMPRESSIBILITY OF THE SOIL | | | IS IN DOUBT OR WHERE A LOAD-BEARING VALUE SUPERIOR TO | | | THAT SPECIFIED IN THIS CODE IS CLAIMED, THE BUILDING | | | OFFICIAL SHALL BE PERMITTED TO REQUIRE THAT A | | | GEOTECHNICAL INVESTIGATION BE CONDUCTED. NO PRODUCT | | | INFORMATION FOR THE HELICAL PIERS SHEET S-10 DETAIL # 1 | | | INDICATES THE USE OF HELICAL PILE WHERE AS DETAIL 2 & 3 | | | OTH LOOK LIKE AUGER PILE. 107.2.1.3 ADDITIONAL | | | INFORMATION IS REQUIRED. | | | | | | 8) BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL | | | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND | | | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT | | | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | 9) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION | | | & REMOVE & REPLACE ANY PAGES AS NECESSARY. A | | | TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT | | | NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE THE | | | CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2014-05-02 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2014-05-02 |
Time |
12:17 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-05-02 |
Time |
11:04 |
Sent To |
|
|
| Notes |
| 2014-05-02 12:16:57 | BUILDING PLAN REVIEW | | | PERMIT: 14020179 | | | PCN: 00-42-43-24-00-000-5251 | | | P. B. C. TO BE ANNEXED | | | ADD: 2132 INDIAN RD | | | CONT: CREATIVE CONTRACTING GROUP | | | TEL: (561)333-1445 | | | | | | 2010 FLORIDA BUILDING CODE W | | | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | | | 2010 EXISTING BUILDING CODE LEVEL II 701.3 | | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | | | 1ST REVIEW | | | DATE: TUES. FEB. 25/ 2014 | | | ACTION: DENIED | | | | | | 1) ADDRESS/ COMPLIED. | | | | | | 2) 2ND REQUEST. THIS SITE IS BEING ANNEXED INTO THE | | | CITY, IT IS LOCATED WITHIN AN A8 FLOOD ZONE. THE | | | MINIMUM BASE FLOOD ELEVATION IS 16.00 FT NGVD THE CITY | | | OF WEST PALM BEACH REQUIRES AN ADDITIONAL 6 INCHES TO | | | THE BASE FLOOD OR A FINISH FLOOR OF 16.5 FT NGVD. | | | THE SURVEY INDICATES A FINISH FLOOR OF 16.53 NGVD. | | | | | | 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING | | | CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | | 107.3.5 MINIMUM PLAN REVIEW CRITERIA FOR BUILDINGS. | | | 107.3.5.1 COMMERCIAL BUILDINGS: | | | 107.3.5.1.1. BUILDING | | | 107.3.5.1.1.SITE REQUIREMENTS: FLOOD HAZARD AREAS, | | | FLOOD ZONES, AND DESIGN FLOOD ELEVATIONS PROVIDE WHAT | | | THE EXISTING FINISH FLOOR ELEVATION IS IN NDVD. | | | | | | 2.2 COMPLIED. | | | SHEET S7 INDICATES THE OCCUPANCY AS A F1 LIGHT AUTO | | | REPAIR/ USED TIRE SALE, PLEASE REVIEW 2010 FBC-B 406.6 | | | REPAIR GARAGES ARE SPECIAL OCCUPANCIES LISTED AS A S2. | | | | | | 2.3)COMPLIED. | | | OCCUPANCY LOAD/EGRESS REQUIREMENTS SHALL INCLUDE: | | | SPECIFIC OCCUPANCY REQUIREMENTS | | | | | | 2.4 2ND REQUEST. STRUCTURAL REQUIREMENTS SHALL INCLUDE: | | | SOIL CONDITIONS/ANALYSIS- MISSING | | | BUILDING ENVELOPE: PRODUCT APPROVALS SEE COMMENT 6 | | | BELOW. | | | FOUNDATION MISSING ELEVATION CERTIFICATE. | | | FLOOD REQUIREMENTS IN ACCORDANCE WITH SECTION 1612, | | | INCLUDING LOWEST FLOOR ELEVATIONS, ENCLOSURES, FLOOD | | | DAMAGE-RESISTANT MATERIALS | | | | | | | | | 3) PLEASE PROVIDE A CURRENT SURVEY SIGNED AND SEALED | | | (2) ORIGINALS & FLOOD ZONE CERTIFICATES, THIS STRUCTURE | | | IS LOCATED IN A A8 FLOOD ZONE WITH A REQUIRED 16.00 | | | ELE. NGVD. THE CITY MUNI CODE FLOOD PREVENTION AND | | | CONTROL REQUIRES AN ADDITIONAL 6 INCH FREE BOARD FOR | | | RESIDENTIAL AND FOR COMMERCIAL FLOOD PROOFING FOR THE | | | SAME 6 INCHES PLUS A ADDITIONAL 6 INCHES IF FLOOD | | | PROOFING AND THE FLOOR NOT BEING ABOVE 16.5 FT. NGVD. | | | FBC BUILDING 3110.1.2 / CITY OF WPB CODE OF ORDINANCES | | | SECTION 94-546. STRUCTURE IS LOCATED IN AN "A" FLOOD | | | ZONE. A FLOOD ELEVATION CERTIFICATE WILL BE REQUIRED. | | | PLEASE REVIEW CITY ORDINANCE FOR THE CITY REQUIREMENTS | | | REQUIRE AN ADDITIONAL 6 INCHES OF ELEVATION | | | | | | DURING THE PERMITTING OF THIS STRUCTURE THERE WILL BE | | | REQUIRED (3) DIFFERENT FLOOD ZONE CERTIFICATES | | | REQUIRED: | | | (1) A FLOOD ZONE CERTIFICATE IS REQUIRED AS PART OF THE | | | PLAN REVIEW DOCUMENTS WITH THE PROPOSED FINISH FLOOR | | | HEIGHT. | | | (2) ONCE THE FIRST FLOOR SLAB IS POURED THE 2ND | | | ELEVATION CERTIFICATE IS REQUIRED | | | (3) BEFORE THE ISSUANCE OF A CERTIFICATE OF OCCUPANCY | | | OR A CERTIFICATE OF COMPLETION THE 3RD FLOOD ZONE | | | CERTIFICATE IS REQUIRED WITH THE HEIGHT OF ALL EXTERIOR | | | ATTENDANT | | | A/C PADS OR OTHER SLABS FOR GENERATORS | | | | | | FEMA FORM OMB NO. 1660-0008 EXPIRES: | | | JULY 31,2015 | | | | | | FEMA'S NEW ELEVATION CERTIFICATE (EC) WAS APPROVED FOR | | | USE, EFFECTIVE AUGUST 1/ 2013, THROUGH JULY 31/ 2015. | | | | | | 4) COMPLIED EXPOSURE C. | | | | | | 5) SEMI-COMPLIED. SEE COMMENT # 6 BELOW. 2010 FBC | | | 107.3.4.1 PRODUCT APPROVALS. THOSE PRODUCTS WHICH ARE | | | REGULATED BY THE DCA RULE 9N-03 SHALL BE REVIEWED AND | | | APPROVED IN WRITING BY THE DESIGNER OF RECORD PRIOR TO | | | SUBMITTAL FOR JURISDICTIONAL APPROVAL. | | | FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR | | | SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS, | | | SHOP DRAWINGS ETC.. | | | | | | 6) 2010 FBC-B 1609.1.2 PROTECTION OF OPENINGS, | | | 1609.6.4.41 COMPONENTS & CLADDING | | | FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS RULE 9N-3 NOV. | | | 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION | | | SYSTEMS THAT WILL REQUIRE PRODUCT APPROVALS: | | | | | | (31)(A) EXTERIOR DOORS. COMPLIED. | | | | | | (31)(C) WALL LOUVERS- REQUIRE PRODUCT APPROVALS 1ST | | | REVIEW! | | | | | | (D) 2ND REQUEST, NOA 12-0716.16 ROOFING PRODUCTS AND | | | ASSEMBLIES FOR FLAT ROOFS PLEASE IDENTIFY SUB-SYSTEMS | | | AND ASSOCIATED PRESSURES, REVIEW LIMITATIONS FOR THIS | | | APPROVAL. | | | NO SUB-SYSTEM WAS IDENTIED, DEPENDING ON WHICH | | | SUB-SYSTEM IS IDENTIFIED. ZONES 2 & 3, MAY REQUIRE | | | ENHANCED FASTENING SEE LIMITATION 7 & 9. | | | | | | 7) 2ND REQUEST, OWNERS SOILS REPORT PROVIDED. SHEET S-6 | | | & S-10 BOTH INDICATE THE USE OF HELICAL PILES PER | | | COLUMN, IS THERE A SUPPORTING SOILS REPORT/ 2010 FBC-B | | | 1803.5.2 QUESTIONABLE SOIL. | | | WHERE THE CLASSIFICATION, STRENGTH OR COMPRESSIBILITY | | | OF THE SOIL IS IN DOUBT OR WHERE A LOAD-BEARING VALUE | | | SUPERIOR TO THAT SPECIFIED IN THIS CODE IS CLAIMED, THE | | | BUILDING OFFICIAL SHALL BE PERMITTED TO REQUIRE THAT A | | | GEOTECHNICAL INVESTIGATION BE CONDUCTED. | | | | | | 8) 2ND REQUEST. NO PRODUCT INFORMATION FOR THE HELICAL | | | PIERS SHEET S-10 DETAIL # 1 INDICATES THE USE OF | | | HELICAL PILE WHERE AS DETAIL 2 & 3 OTH LOOK LIKE AUGER | | | PILE? 107.2.1.3 ADDITIONAL INFORMATION IS REQUIRED. | | | | | | 9) COMPLIED. | | | | | | 10) 406.6.1 GENERAL. | | | REPAIR GARAGES SHALL BE CONSTRUCTED IN ACCORDANCE WITH | | | THE FLORIDA FIRE PREVENTION CODE AND SECTIONS 406.6.1 | | | THROUGH 406.6.6. THIS OCCUPANCY SHALL NOT INCLUDE MOTOR | | | FUEL-DISPENSING FACILITIES, AS REGULATED IN SECTION | | | 406.5. | | | | | | 11) NOT USED. | | | | | | 12) WHEN RESUBMITTING PLANS PLEASE INDICATE THE | | | REVISION & REMOVE & REPLACE ANY PAGES AS NECESSARY. A | | | TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT | | | NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE THE | | | CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2014-02-25 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2014-02-25 |
Time |
11:50 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-02-25 |
Time |
09:41 |
Sent To |
|
|
| Notes |
| 2014-02-25 11:50:08 | BUILDING PLAN REVIEW | | | PERMIT: 14020179 | | | PCN: 00-42-43-24-00-000-5251 | | | P. B. C. TO BE ANNEXED | | | ADD: 2321 INDIAN RD VS. 2131 INDIAN RD | | | CONT: CREATIVE CONTRACTING GROUP | | | TEL: (561)333-1445 | | | | | | 2010 FLORIDA BUILDING CODE W | | | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | | | 2010 EXISTING BUILDING CODE LEVEL II 701.3 | | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | | | 1ST REVIEW | | | DATE: TUES. FEB. 25/ 2014 | | | ACTION: DENIED | | | | | | 1) PLEASE REVIEW THE ABOVE PROPERTY CONTROL NUMBER TO | | | VERIFY THIS IS THE PROPERTY THAT IS GOING TO BE ANNEXED | | | INTO THE CITY OF W.P.B. | | | NOTE THERE ARE TWO ADDRESSES LISTED IN THE ADDRESS | | | FIELD ABOVE. THE P.B.C. PROPERTY APPRAISERS SITE HAS | | | THE ADDRESS OF 2132 INDIAN RD. THE PERMIT APPLICATION | | | HAS THE ADDRESS AS 2312 INDIAN RD. PLEASE VERIFY THE | | | PROPERTY APPRAISERS SITE IS CORRECT AND CORRECT THE | | | ADDRESS ON THE PERMIT APPLICATION. WHEN THIS PROPERTY | | | IS TRANSFEERED, RECORDED THE ADDRESS NEEDS TO BE | | | CORRECT, WITH ALL RECORDS BEING SUBMITTED FOR | | | PERMITING. | | | | | | 2) 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | | 107.3.5 MINIMUM PLAN REVIEW CRITERIA FOR BUILDINGS. | | | 107.3.5.1 COMMERCIAL BUILDINGS: | | | 107.3.5.1.1 BUILDING | | | 2.1.SITE REQUIREMENTS: FLOOD HAZARD AREAS, FLOOD ZONES, | | | AND DESIGN FLOOD ELEVATIONS PROVIDE WHAT THE EXISTING | | | FINISH FLOOR ELEVATION IS IN NDVD | | | | | | 2.2 SHEET S7 INDICATES THE OCCUPANCY AS A F1 LIGHT AUTO | | | REPAIR/ USED TIRE SALE, PLEASE REVIEW 2010 FBC-B 406.6 | | | REPAIR GARAGES ARE SPECIAL OCCUPANCIES LISTED AS A S2. | | | | | | 2.3) OCCUPANCY LOAD/EGRESS REQUIREMENTS SHALL INCLUDE: | | | SPECIFIC OCCUPANCY REQUIREMENTS | | | | | | 2.4 STRUCTURAL REQUIREMENTS SHALL INCLUDE: | | | SOIL CONDITIONS/ANALYSIS | | | BUILDING ENVELOPE: PRODUCT APPROVALS | | | FOUNDATION | | | FLOOD REQUIREMENTS IN ACCORDANCE WITH SECTION 1612, | | | INCLUDING LOWEST FLOOR ELEVATIONS, ENCLOSURES, FLOOD | | | DAMAGE-RESISTANT MATERIALS | | | | | | | | | 3) PLEASE PROVIDE A CURRENT SURVEY SIGNED AND SEALED | | | (2) ORIGINALS & FLOOD ZONE CERTIFICATES, THIS STRUCTURE | | | IS LOCATED IN A A8 FLOOD ZONE WITH A REQUIRED 16.00 | | | ELE. NGVD. THE CITY MUNI CODE FLOOD PREVENTION AND | | | CONTROL REQUIRES AN ADDITIONAL 6 INCH FREE BOARD FOR | | | RESIDENTIAL AND FOR COMMERCIAL FLOOD PROOFING FOR THE | | | SAME 6 INCHES PLUS A ADDITIONAL 6 INCHES IF FLOOD | | | PROOFING AND THE FLOOR NOT BEING ABOVE 16.5 FT. NGVD. | | | FBC BUILDING 3110.1.2 / CITY OF WPB CODE OF ORDINANCES | | | SECTION 94-546. STRUCTURE IS LOCATED IN AN "A" FLOOD | | | ZONE. A FLOOD ELEVATION CERTIFICATE WILL BE REQUIRED. | | | PLEASE REVIEW CITY ORDINANCE FOR THE CITY REQUIREMENTS | | | REQUIRE AN ADDITIONAL 6 INCHES OF ELEVATION | | | | | | DURING THE PERMITTING OF THIS STRUCTURE THERE WILL BE | | | REQUIRED (3) DIFFERENT FLOOD ZONE CERTIFICATES | | | REQUIRED: | | | (1) A FLOOD ZONE CERTIFICATE IS REQUIRED AS PART OF THE | | | PLAN REVIEW DOCUMENTS WITH THE PROPOSED FINISH FLOOR | | | HEIGHT. | | | (2) ONCE THE FIRST FLOOR SLAB IS POURED THE 2ND | | | ELEVATION CERTIFICATE IS REQUIRED | | | (3) BEFORE THE ISSUANCE OF A CERTIFICATE OF OCCUPANCY | | | OR A CERTIFICATE OF COMPLETION THE 3RD FLOOD ZONE | | | CERTIFICATE IS REQUIRED WITH THE HEIGHT OF ALL EXTERIOR | | | ATTENDANT | | | A/C PADS OR OTHER SLABS FOR GENERATORS | | | | | | FEMA FORM OMB NO. 1660-0008 EXPIRES: | | | JULY 31,2015 | | | | | | FEMA'S NEW ELEVATION CERTIFICATE (EC) WAS APPROVED FOR | | | USE, EFFECTIVE AUGUST 1/ 2013, THROUGH JULY 31/ 2015. | | | | | | 4) SHEET S-6 INDICATES THE WIND DESIGN TO A EXPOSURE D/ | | | 170 MPH, 3 SECOND GUST. THE DESIGNER OF RECORD CAN | | | DESIGN TO THIS MORE STRINGENT DESIGN, THE BUILDING IS | | | LOCATED IN A WIND EXPOSURE C/ 170 MPH WIND ZONE. PLEASE | | | PROVIDE PRESSURES FOR COMPONENTS AND CLADDING FOR WALL | | | ZONES AND ROOF ZONES. PLEASE NOTE THAT WE DO USE 10 SQ | | | FT FOR COMPONENTS AND CLADDING FOR ROOFING MATERIALS. | | | 2010 FBC-B 1609.1.1 DETERMINATION OF WIND DESIGN- | | | CHAPTER 6 OF ASCE 7-10. | | | 1609.3 BASIC WIND SPEED FIGURE 1609.A-C | | | | | | 5) 2010 FBC 107.3.4.1 PRODUCT APPROVALS. THOSE PRODUCTS | | | WHICH ARE REGULATED BY THE DCA RULE 9N-03 SHALL BE | | | REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF | | | RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL. | | | FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR | | | SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS, | | | SHOP DRAWINGS ETC.. | | | | | | 6) 2010 FBC-B 1609.1.2 PROTECTION OF OPENINGS, | | | 1609.6.4.41 COMPONENTS & CLADDING | | | FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS RULE 9N-3 NOV. | | | 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION | | | SYSTEMS THAT WILL REQUIRE PRODUCT APPROVALS: | | | (31)(A) EXTERIOR DOORS. | | | (D) ROOFING PRODUCTS AND ASSEMBLIES FOR FLAT ROOFS | | | PLEASE IDENTIFY SUB-SYSTEMS AND ASSOCIATED PRESSURES, | | | REVIEW LIMITATIONS FOR THIS APPROVAL. | | | | | | 7) SHEET S-6 & S-10 BOTH INDICATE THE USE OF HELICAL | | | PILES PER COLUMN, IS THERE A SUPPORTING SOILS REPORT/ | | | 2010 FBC-B 1803.5.2 QUESTIONABLE SOIL. | | | WHERE THE CLASSIFICATION, STRENGTH OR COMPRESSIBILITY | | | OF THE SOIL IS IN DOUBT OR WHERE A LOAD-BEARING VALUE | | | SUPERIOR TO THAT SPECIFIED IN THIS CODE IS CLAIMED, THE | | | BUILDING OFFICIAL SHALL BE PERMITTED TO REQUIRE THAT A | | | GEOTECHNICAL INVESTIGATION BE CONDUCTED. | | | | | | 8) SHEET S-10 DETAIL # 1 INDICATES THE USE OF HELICAL | | | PILE WHERE AS DETAIL 2 & 3 OTH LOOK LIKE AUGER PILE? | | | 107.2.1.3 ADDITIONAL INFORMATION IS REQUIRED. | | | | | | 9) S12 THERE IS A NOTE TO HAVE THE ROLL ROOFING TO GO | | | OVER THE TOP OF THE WALL AND DOWNWARD ON THE WALL FOR | | | 16 INCHES? PLEASE EXPLAIN WHY THE ROOFING CONTINUES | | | DOWN THE WALL FOR 16 INCHES? ALSO SHOW COMPLIANCE WITH | | | 2010 FBC-B: 1503.4.3 GUTTERS. | | | GUTTERS AND LEADERS PLACED ON THE OUTSIDE OF BUILDINGS, | | | OTHER THAN GROUP R-3, PRIVATE GARAGES AND BUILDINGS OF | | | TYPE V CONSTRUCTION, SHALL BE OF NONCOMBUSTIBLE | | | MATERIAL OR A MINIMUM OF SCHEDULE 40 PLASTIC PIPE. | | | | | | 1503.7 PROTECTION AGAINST DECAY AND TERMITES. | | | CONDENSATE LINES AND ROOF DOWNSPOUTS SHALL DISCHARGE AT | | | LEAST 1 FOOT (305 MM) AWAY FROM THE STRUCTURE SIDEWALL, | | | WHETHER BY UNDERGROUND PIPING, TAIL EXTENSIONS, OR | | | SPLASH BLOCKS. GUTTERS WITH DOWNSPOUTS ARE REQUIRED ON | | | ALL BUILDINGS WITH EAVES OF LESS THAN 6 INCHES (152 MM) | | | HORIZONTAL PROJECTION EXCEPT FOR GABLE END RAKES OR ON | | | A ROOF ABOVE ANOTHER ROOF. | | | | | | SIZE TO THE GUTTER AND ROOF LEADERS TO BE SIZED TO THE | | | REQUIREMENTS FOUND IN THE 2010 FBC-P. | | | | | | 10) 406.6.1 GENERAL. | | | REPAIR GARAGES SHALL BE CONSTRUCTED IN ACCORDANCE WITH | | | THE FLORIDA FIRE PREVENTION CODE AND SECTIONS 406.6.1 | | | THROUGH 406.6.6. THIS OCCUPANCY SHALL NOT INCLUDE MOTOR | | | FUEL-DISPENSING FACILITIES, AS REGULATED IN SECTION | | | 406.5. | | | | | | 11) | | | | | | 12) WHEN RESUBMITTING PLANS PLEASE INDICATE THE | | | REVISION & REMOVE & REPLACE ANY PAGES AS NECESSARY. A | | | TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT | | | NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE THE | | | CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2014-10-28 |
|
|
Cont ID |
|
| Sent By |
dhayes |
Date |
2014-10-28 |
Time |
13:45 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2014-10-28 |
Time |
13:39 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2014-05-01 |
|
|
Cont ID |
|
| Sent By |
albarran |
Date |
2014-05-01 |
Time |
10:25 |
Rev Time |
0.00 |
| Received By |
albarran |
Date |
2014-05-01 |
Time |
09:12 |
Sent To |
|
|
| Notes |
| 2014-05-01 10:26:38 | PREVIOUS CORRECTION REQUESTS HAVE BEEN ADDRESSED |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2014-03-04 |
|
|
Cont ID |
|
| Sent By |
albarran |
Date |
2014-03-04 |
Time |
15:42 |
Rev Time |
0.00 |
| Received By |
albarran |
Date |
2014-03-04 |
Time |
14:40 |
Sent To |
|
|
| Notes |
| 2014-03-04 15:46:55 | AS PER FBC-B 406.6 REPAIR GARAGES, THIS TYPE OF | | | ESTABLISHMENT REQUIRES MECHANICAL VENTILATION WHICH IS | | | CONTROLLED AT THE ENTRANCE TO THE GARAGE. THE SUBMITTED | | | DRAWINGS DO NOT INCLUDE EITHER OF THE COMPONENTS | | | REQUIRED, THE EXHAUST FAN OR THE CONTROLLER. |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
2 |
Status |
P |
Date |
2014-06-14 |
|
|
Cont ID |
|
| Sent By |
mgonzale |
Date |
2014-06-14 |
Time |
|
Rev Time |
1.00 |
| Received By |
mgonzale |
Date |
2014-06-14 |
Time |
|
Sent To |
|
|
| Notes |
| 2014-06-14 11:58:26 | NO OBJECTION | | | |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
F |
Date |
2014-03-31 |
|
|
Cont ID |
|
| Sent By |
Mgonzale |
Date |
2014-03-31 |
Time |
|
Rev Time |
0.50 |
| Received By |
mgonzale |
Date |
2014-03-31 |
Time |
|
Sent To |
I |
|
| Notes |
| 2014-03-31 14:39:40 | NOTE: | | | PLAN SUBMITTED DOES NOT SHOW STORM WATER DRAINAGE | | | ELEMENTS. PLEASE BE ADVISED, THE CITY'S NPDES MS4 | | | PERMIT AUTHORIZES THE CITY TO DISCHARGE STORMWATERS OF | | | THE STATE IN ACCORDANCE WITH THE STORMWATER MANAGEMENT | | | PROGRAMS (SWMP). THE SWMP INCLUDES POLLUTION PREVENTION | | | MEASURES, TREATMENT OR REMOVAL TECHNIQUES AND OTHER | | | APPROPRIATE MEANS TO CONTROL THE QUALITY OF STORMWATER | | | DISCHARGED FROM THE MS4. ONE COMPONENT OF THE SWMP IS | | | TO REDUCE THE DISCHARGE OF POLLUTANTS IN STORMWATER | | | REDEVELOPED AREAS CONSISTENT WITH THE SFWMF ERP | | | REQUIREMENTS. | | | PER SFWMD CRITERIA, ALL PROJECTS SHALL PROVIDE ONSITE | | | RETENTION FOR A VOLUME EQUIVALENT TO THE FIRST INCH OF | | | RUNOFF FROM THE DEVELOPED PROJECT, OR THE TOTAL RUNOFF | | | OF 2.5 INCHES TIMES THE PERCENTAGE OF IMPERVIOUSNESS, | | | WHICHEVER IS THE GREATER. WATER SURFACE AND ROOFED | | | AREAS CAN BE DEDUCTED FROM SITE AREAS ONLY FOR | | | WATER-QUALITY PERVIOUS/IMPERVIOUS CALCULATIONS. | | | | | | MANUEL JULIAN GONZALEZ | | | ENGINEERING PROJECT COORDINATOR | | | ENGINEERING SERVICES AND PUBLIC WORKS DEPARTMENT | | | 401 CLEMATIS STREET, 4TH FLOOR | | | WEST PALM BEACH, FL 33401 | | | (MAILING ADDRESS: P.O. BOX 3366, ZIP 33402) | | | MAIN PHONE: (561) 822-1200 | | | DIRECT: (561) 494-1085 | | | FAX: (561) 494-1116 | | | EMAIL: [email protected] | | | WWW.WPB.ORG/ENGINEERING | | | | | | | | | | | | | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2014-10-28 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2014-10-27 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2014-10-27 |
Time |
15:19 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2014-04-28 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2014-04-28 |
Time |
12:30 |
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2014-04-28 |
Time |
12:10 |
Sent To |
E |
|
| Notes |
| 2014-04-24 10:48:13 | NEW SHEETS SUBMITTED. JG. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2014-02-27 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2014-02-27 |
Time |
15:40 |
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2014-02-27 |
Time |
14:20 |
Sent To |
|
|
| Notes |
| 2014-02-27 15:40:30 | THE FOLLOWING COMMENTS WERE SUBMITTED BY PETER LEDUC, | | | FIRE MARSHAL, BUREAU OF FIRE PREVENTION, WEST PALM | | | BEACH FIRE RESCUE. | | | | | | THE PERMIT IS APPROVED WITH THE FOLLOWING COMMENTS. | | | | | | 1. NOTICE REQUIRED FOR STRUCTURES WITH LIGHT-FRAME | | | TRUSS-TYPE CONSTRUCTION. ANY COMMERCIAL, INDUSTRIAL, OR | | | ANY MULTIUNIT RESIDENTIAL STRUCTURE OF THREE UNITS OR | | | MORE WHICH USES HORIZONTAL OR VERTICAL LIGHT-FRAME | | | TRUSS-TYPE CONSTRUCTION IN ANY PORTION SHALL BE MARKED | | | WITH AN APPROVED SYMBOL. THE APPROVED SYMBOL SHALL BE | | | PLACED WITHIN 24 INCHES TO THE LEFT OF THE MAIN ENTRY | | | DOOR. | | | | | | 2. BOLLARD PROTECTION FROM VEHICLE IMPACT AND | | | PEDESTRIAN EGRESS IS REQUIRED AT THE WAITING AREA AND | | | RESTROOM AS INDICATED/HIGHLIGHTED ON THE PLAN. | | | | | | 3. CO DECTECTORS ARE REQUIRED IN EACH BATHROOM, SERVICE | | | AND WAITING AREAS. | | | | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2015-02-05 |
|
|
Cont ID |
|
| Sent By |
|
Date |
2015-02-05 |
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
2015-02-05 |
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2015-01-06 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2015-01-06 |
Time |
08:35 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-12-22 |
Time |
07:47 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2014-11-24 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2014-11-24 |
Time |
12:54 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-10-20 |
Time |
11:45 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2014-09-23 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2014-09-23 |
Time |
14:23 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-09-05 |
Time |
16:57 |
Sent To |
|
|
| Notes |
| 2014-09-05 16:58:52 | INCOMING SENT TO C03 . JW |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2014-06-16 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2014-06-16 |
Time |
11:12 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2014-04-21 |
Time |
11:18 |
Sent To |
|
|
| Notes |
| 2014-04-24 11:19:10 | RESUBMITTAL SENT TO C2 SHELF FOR REVIEW. JG. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2014-03-31 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2014-03-31 |
Time |
17:15 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2014-02-05 |
Time |
11:43 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2014-03-26 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2014-03-26 |
Time |
12:41 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-03-26 |
Time |
12:41 |
Sent To |
|
|
| Notes |
| 2014-03-26 12:42:49 | NO MECHANICAL IN PLANS. JW |
|
|
| Review Stop |
NFIP |
NFIP REVIEW ACTIVITY |
| Rev No |
2 |
Status |
N |
Date |
2017-02-27 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2017-02-27 |
Time |
07:52 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2017-02-27 |
Time |
07:52 |
Sent To |
|
|
| Notes |
| 2017-02-27 07:53:08 | ****CORRECTIONS**** | | | ****PROVISO**** | | | FINISHED CONSTRUCTION ELEVATION CERTIFICATE PREPARED BY | | | DENNIS J. GABRIELE, ALL COUNTY SURVEYORS, DATED | | | 11/14/2014 | | | REVISE ELEVATION CERTIFICATE AS NOTED AND SUBMIT | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | 1. A3, PROPERTY DESCRIPTION PROVIDES PARCEL ID. THIS | | | HAS CHANGED AND IS NO LONGER IN UNINCORPORATED PALM | | | BEACH COUNTY, REVISE. | | | | | | 2. A5, THE LATITUDE/LONGITUDE PROVIDED IS NOT ACCURATE. | | | SEE INSTRUCTIONS, THIS LOCATION IS TO BE THE CENTER OF | | | THE BUILIDNG ACCURATE WITHIN 66'. | | | | | | |
|
|
| Review Stop |
NFIP |
NFIP REVIEW ACTIVITY |
| Rev No |
1 |
Status |
F |
Date |
2016-03-25 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2016-03-25 |
Time |
17:04 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2016-03-25 |
Time |
17:04 |
Sent To |
|
|
| Notes |
| 2016-03-25 17:10:07 | ****CORRECTIONS**** | | | PLAN REVIEW IN PROGRESS | | | FINISHED CONSTRUCTION ELEVATION CERTIFICATE PREPARED BY | | | DENNIS J. GABRIELE, ALL COUNTY SURVEYORS, DATED | | | 11/14/2014 | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | 1. A3, PROPERTY DESCRIPTION PROVIDES PARCEL ID. THIS | | | HAS CHANGED AND IS NO LONGER IN UNINCORPORATED PALM | | | BEACH COUNTY, REVISE. | | | | | | 2. A5, THE LATITUDE/LONGITUDE PROVIDED IS NOT ACCURATE. | | | SEE INSTRUCTIONS, THIS LOCATION IS TO BE THE CENTER OF | | | THE BUILIDNG ACCURATE WITHIN 66'. | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2014-11-01 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2014-11-01 |
Time |
08:42 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2014-11-01 |
Time |
08:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2014-09-22 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2014-09-22 |
Time |
08:43 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2014-09-22 |
Time |
07:05 |
Sent To |
|
|
| Notes |
| 2014-09-22 08:43:05 | 9/22/14 - DENIED | | | 1) SEPARATE SANITARY FACILITIES ARE REQUIRED FOR MALES | | | AND FEMALES PER THE 2010 FBC SEC.403.2 | | | 2) BOTH RESTROOMS SHALL BE HANDICAPPED ACCESSIBLE PER | | | THE 2010 FBC, ACCESSIBILITY, SEC.213.2. | | | 3) SHOW THE FIXTURE CLEARANCES IN THE "EMPLOYEE | | | RESTROOM". THE FIXTURE SPACEING SHALL COMPLY WITH THE | | | 2010 FBC ACCESSIBILITY. | | | 4) SUBMIT A WATER PIPNG DIAGRAM FOR REVIEW. THE WATER | | | SUPPLY SYSTEM SHALL COMPLY W/SEC.604 OF THE 2010 FPC | | | SEC.WPB AMEND. TO 2010 FBC SEC.107.2.1., 107.3.5.1. | | | 5) SUBMIT MANUF. SPECIFICATION SHEETS FOR THE EMERGENCY | | | EYEWASH/SHOWER AND THE WATERLESS URINAL. THE WATERLESS | | | URINAL SHALL COMPLY W/ANSI Z124.9 ( PLASTIC) OR ASME | | | A112.19.19 (VITREOUS CHINA). WPB AMEND. TO 2010 FBC | | | SEC.107.2.1, | | | FPC SEC. 419.1 | | | 6) CLEANOUTS ARE REQD. IN THE BASE OF EACH SOIL OR | | | WASTE STACK PER 2010 FBC SEC. 708.3.4. | | | 7) AS DRAWN, THE SERVICE SINK IS INSTALLED ON A | | | HORIZONTAL WET VENT WHICH IS NOT PERMITTED PER THE 2010 | | | FPC SEC.909.1. | | | 8) THE URINAL SHALL BE CONNECTED TO A VENTED WASTE | | | STACK IF IT IS WALL HUNG. 2010 FPC 901.2.1. | | | 9) THE VENTS THRU THE ROOF CAN BE 2" IN DIAMETER IN | | | LIEU OF 2". | | | 10) SHT. S-12 - INDICATE THE SLOPE OF THE RAIN GUTTERS | | | ON THE PLAN. THE PITCH OF THE GUTTERS AND THE ROOF AREA | | | DRAINED SHALL COMPLY WITH TABLE 1106.6 OF THE 2010 FPC. | | | | | | PLUMBING PLAN REVIEW | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | 561-805-6692 | | | [email protected] | | | | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2014-05-05 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2014-05-02 |
Time |
11:04 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-05-02 |
Time |
12:17 |
Sent To |
|
|
| Notes |
| 2014-05-02 12:27:26 | PLUMBING PLAN REVIEW | | | PERMIT: 14020179 | | | PCN: 00-42-43-24-00-000-5251 | | | P. B. C. TO BE ANNEXED | | | ADD: 2321 INDIAN RD VS. 2131 INDIAN RD | | | CONT: CREATIVE CONTRACTING GROUP | | | TEL: (561)333-1445 | | | | | | 2010 FLORIDA BUILDING CODE W | | | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | | | 2010 EXISTING BUILDING CODE LEVEL II 701.3 | | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | | | 2ND REVIEW | | | DATE:FRIDAY APRIL 02/ 2014 | | | ACTION: DENIED | | | | | | 1-2) COMPLIED. SHEET S7 INDICATES THE OCCUPANCY AS A F1 | | | LIGHT AUTO REPAIR/ USED TIRE SALE, PLEASE REVIEW 2010 | | | FBC-B 406.6 REPAIR GARAGES ARE SPECIAL OCCUPANCIES | | | LISTED AS A S2. | | | | | | 3) 2ND REQUEST. THE SANITARY PLANS ARE DRAWN USING A | | | WET VENT SYSTEM. WATER CLOSETS, AND SERVICE SINKS DO | | | NOT HAVE VENTS. SEE 2010 FBC-PLUMBING | | | 907.1 INDIVIDUAL VENT PERMITTED. | | | EACH TRAP AND TRAPPED FIXTURE IS PERMITTED TO BE | | | PROVIDED WITH AN INDIVIDUAL VENT. THE INDIVIDUAL VENT | | | SHALL CONNECT TO THE FIXTURE DRAIN OF THE TRAP OR | | | TRAPPED FIXTURE BEING VENTED. | | | 908.1 INDIVIDUAL VENT AS COMMON VENT. | | | AN INDIVIDUAL VENT IS PERMITTED TO VENT TWO TRAPS OR | | | TRAPPED FIXTURES AS A COMMON VENT. THE TRAPS OR TRAPPED | | | FIXTURES BEING COMMON VENTED SHALL BE LOCATED ON THE | | | SAME FLOOR LEVEL. | | | | | | 908.2 CONNECTION AT THE SAME LEVEL. | | | WHERE THE FIXTURE DRAINS BEING COMMON VENTED CONNECT AT | | | THE SAME LEVEL, THE VENT CONNECTION SHALL BE AT THE | | | INTERCONNECTION OF THE FIXTURE DRAINS OR DOWNSTREAM OF | | | THE INTERCONNECTION. | | | | | | 908.3 CONNECTION AT DIFFERENT LEVELS. | | | WHERE THE FIXTURE DRAINS CONNECT AT DIFFERENT LEVELS, | | | THE VENT SHALL CONNECT AS A VERTICAL EXTENSION OF THE | | | VERTICAL DRAIN. THE VERTICAL DRAIN PIPE CONNECTING THE | | | TWO FIXTURE DRAINS SHALL BE CONSIDERED THE VENT FOR THE | | | LOWER FIXTURE DRAIN, AND SHALL BE SIZED IN ACCORDANCE | | | WITH TABLE 908.3. THE UPPER FIXTURE SHALL NOT BE A | | | WATER CLOSET. | | | FLORIDA BUILDING CODE INFORMAL INTERPRETATION: | | | DATE: WED DEC 17 2003 | | | REPORT #: 2241 | | | CODE: PLUMBING | | | SECTION: 909.1 | | | QUESTION: | | | IS IT THE INTENT OF SECTION 909.1 WET VENTING TO | | | EXCLUDE URINALS AS A FIXTURE TO BE ALLOW AS PART OF A | | | WET | | | VENTED SYSTEM? | | | ANSWER: | | | NO. WET VENTING RELIES ON LOW FLOW VELOCITY, LOW FLOW | | | RATES, AND LOW PROBABILITY OF SIMULTANEOUS | | | DISCHARGE. FOR THAT REASON, WET VENTING IS LIMITED TO | | | TWO BATHROOM GROUPS, LOCATED ON THE SAME FLOOR LEVEL. | | | ALTHOUGH A BATHROOM GROUP BY DEFINITION DOES NOT | | | INCLUDE URINALS, URINALS MAY BE REGARDED AS SIMILAR IN | | | FUNCTION TO WATER CLOSETS (SEE 419.2), AND THEY PLACE | | | LESS RELATIVE LOAD ON THE DRAINAGE SYSTEM. URINALS, AS | | | WELL AS EMERGENCY FLOOR DRAINS AND DRINKING FOUNTAINS, | | | MAY BE INCLUDED IN A WET VENT SYSTEM, WITHIN THE | | | LIMITS OF TABLE 909.3. PLEASE NOTE! 12/17/2003-UPON | | | CHALLENGE AND FURTHER REVIEW | | | THIS INTERPRETATION IS MODIFIED AS FOLLOWS: 1) THE CODE | | | PERMITS WET VENTING OF BATHROOM | | | GROUPS, 2) THE DEFINITION OF A BATHROOM GROUP DOES NOT | | | SPECIFICALLY INCLUDE A URINAL, THEREFORE 3) A URINAL | | | MAY NOT BE A PART OF A WET VENT SYSTEM. | | | COMMENTARY: | | | KITCHEN SINKS, WASHING MACHINES AND SIMILAR HIGHER | | | VOLUME FIXTURES WOULD NOT BE PERMITTED ON A WET VENT | | | SYSTEM, AND WOULD HAVE TO DISCHARGE DOWNSTREAM OF THE | | | WET VENT. 12/17/2003-COMMENTARY | | | MODIFICATION: PROPERLY SIZED WET VENTING RESULTS IN | | | ADEQUATE AIRFLOW IN THE WET-VENTED PIPE TO | | | PREVENT THE FIXTURES FROM BEING SUBJECT TO SIPHONAGE OR | | | BACKPRESSURE (PLUS OR MINUS 1-INCH OF WATER | | | COLUMN). THE ORIGINAL INTERPRETATION MET THE INTENT, IF | | | NOT THE LETTER, OF THE CODE SINCE URINALS HAVE, FOR A | | | NUMBER OF YEARS NOW, BEEN LIMITED TO 1 GALLON PER | | | FLUSHING CYCLE. AS LONG AS THE WET VENT IS LIMITED TO | | | TWO | | | BATHROOM GROUPS, THERE IS PROBABLY NO FIELD | | | CONFIGURATION CONTAINING A URINAL THAT WOULD POSE A | | | PROBLEM | | | BUT STRICT APPLICATION OF THE CODE WILL NOT ALLOW IT. | | | | | | 4) COMPLIED. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | | REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL | | | LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH | | | A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE | | | SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE | | | FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR | | | YOUR ANTICIPATED COOPERATION. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2014-02-25 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2014-02-25 |
Time |
12:58 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-02-25 |
Time |
12:00 |
Sent To |
|
|
| Notes |
| 2014-02-25 12:09:50 | PLUMBING PLAN REVIEW | | | PERMIT: 14020179 | | | PCN: 00-42-43-24-00-000-5251 | | | P. B. C. TO BE ANNEXED | | | ADD: 2321 INDIAN RD VS. 2131 INDIAN RD | | | CONT: CREATIVE CONTRACTING GROUP | | | TEL: (561)333-1445 | | | | | | 2010 FLORIDA BUILDING CODE W | | | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | | | 2010 EXISTING BUILDING CODE LEVEL II 701.3 | | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | | | 1ST REVIEW | | | DATE: TUES. FEB. 25/ 2014 | | | ACTION: DENIED | | | | | | 1) SHEET S7 INDICATES THE OCCUPANCY AS A F1 LIGHT AUTO | | | REPAIR/ USED TIRE SALE, PLEASE REVIEW 2010 FBC-B 406.6 | | | REPAIR GARAGES ARE SPECIAL OCCUPANCIES LISTED AS A S2. | | | | | | 2) PLEASE REVIEW YOUR PLUMBING FIXTURE CALCULATIONS AS | | | A F1 3500/ 100= 35 OCCUPANTS AS A F1 OCCUPANCY THE | | | FIXTURE COUNT WILL REQUIRE 1 UNDER THE 2010 | | | FBC-PLUMBING TABLE 403.1 AND FOOTNOTE E WOULD REQUIRE | | | YOU TO GO TO THE ACCESSIBLITY CODE THAT WOULD REQUIRE A | | | HIGH AND LOW. | | | | | | REVIEW YOUR PLUMBING CALCULATION AS A S2 3500/300= 12 | | | OCCUPANTS. THE 2010 FBC-PLUMBING TABLE 403.1 FOOTNOTE F | | | DOES NOT REQUIRE DRINKING FOUNTAINS FOR OCCUPANT LOADS | | | OF 15 AND FEWER. | | | | | | 3) THE SANITARY PLANS ARE DRAWN USING A WET VENT SYSTEM | | | INCLUDED IS URINAL & DRINKING FOUNTAIN, IN THE | | | RESTOOMS, PLEASE SEE FLORIDA BUILDING CODE INFORMAL | | | INTERPRETATION: | | | DATE: WED DEC 17 2003 | | | REPORT #: 2241 | | | CODE: PLUMBING | | | SECTION: 909.1 | | | QUESTION: | | | IS IT THE INTENT OF SECTION 909.1 WET VENTING TO | | | EXCLUDE URINALS AS A FIXTURE TO BE ALLOW AS PART OF A | | | WET | | | VENTED SYSTEM? | | | ANSWER: | | | NO. WET VENTING RELIES ON LOW FLOW VELOCITY, LOW FLOW | | | RATES, AND LOW PROBABILITY OF SIMULTANEOUS | | | DISCHARGE. FOR THAT REASON, WET VENTING IS LIMITED TO | | | TWO BATHROOM GROUPS, LOCATED ON THE SAME FLOOR LEVEL. | | | ALTHOUGH A BATHROOM GROUP BY DEFINITION DOES NOT | | | INCLUDE URINALS, URINALS MAY BE REGARDED AS SIMILAR IN | | | FUNCTION TO WATER CLOSETS (SEE 419.2), AND THEY PLACE | | | LESS RELATIVE LOAD ON THE DRAINAGE SYSTEM. URINALS, AS | | | WELL AS EMERGENCY FLOOR DRAINS AND DRINKING FOUNTAINS, | | | MAY BE INCLUDED IN A WET VENT SYSTEM, WITHIN THE | | | LIMITS OF TABLE 909.3. PLEASE NOTE! 12/17/2003-UPON | | | CHALLENGE AND FURTHER REVIEW | | | THIS INTERPRETATION IS MODIFIED AS FOLLOWS: 1) THE CODE | | | PERMITS WET VENTING OF BATHROOM | | | GROUPS, 2) THE DEFINITION OF A BATHROOM GROUP DOES NOT | | | SPECIFICALLY INCLUDE A URINAL, THEREFORE 3) A URINAL | | | MAY NOT BE A PART OF A WET VENT SYSTEM. | | | COMMENTARY: | | | KITCHEN SINKS, WASHING MACHINES AND SIMILAR HIGHER | | | VOLUME FIXTURES WOULD NOT BE PERMITTED ON A WET VENT | | | SYSTEM, AND WOULD HAVE TO DISCHARGE DOWNSTREAM OF THE | | | WET VENT. 12/17/2003-COMMENTARY | | | MODIFICATION: PROPERLY SIZED WET VENTING RESULTS IN | | | ADEQUATE AIRFLOW IN THE WET-VENTED PIPE TO | | | PREVENT THE FIXTURES FROM BEING SUBJECT TO SIPHONAGE OR | | | BACKPRESSURE (PLUS OR MINUS 1-INCH OF WATER | | | COLUMN). THE ORIGINAL INTERPRETATION MET THE INTENT, IF | | | NOT THE LETTER, OF THE CODE SINCE URINALS HAVE, FOR A | | | NUMBER OF YEARS NOW, BEEN LIMITED TO 1 GALLON PER | | | FLUSHING CYCLE. AS LONG AS THE WET VENT IS LIMITED TO | | | TWO | | | BATHROOM GROUPS, THERE IS PROBABLY NO FIELD | | | CONFIGURATION CONTAINING A URINAL THAT WOULD POSE A | | | PROBLEM | | | BUT STRICT APPLICATION OF THE CODE WILL NOT ALLOW IT. | | | | | | 4A) PLEASE PROVIDE COMPLIANCE WITH 2010 FBC-B 503.7 | | | PROTECTION AGAINST DECAY AND TERMITES. CONDENSATE LINES | | | AND ROOF DOWNSPOUTS SHALL DISCHARGE AT LEAST 1 FOOT | | | (305 MM) AWAY FROM THE STRUCTURE SIDEWALL, WHETHER BY | | | UNDERGROUND PIPING, TAIL EXTENSIONS, OR SPLASH BLOCKS. | | | GUTTERS WITH DOWNSPOUTS ARE REQUIRED ON ALL BUILDINGS | | | WITH EAVES OF LESS THAN 6 INCHES (152 MM) HORIZONTAL | | | PROJECTION EXCEPT FOR GABLE END RAKES OR ON A ROOF | | | ABOVE ANOTHER ROOF. | | | | | | 4B) PROVIDE ROOF CALCULATIONS FOR ROOF DRAINAGE USING | | | THE 100-YEAR HOURLY RAINFALL RATE INDICATED IN 2010 | | | FBC-P FIGURE 1106.1 OR ON OTHER RAINFALL RATES | | | DETERMINED FROM APPROVED LOCAL WEATHER DATA. | | | | | | 4C) 2010 FBC-P 1106.6 SIZE OF ROOF GUTTERS. | | | THE SIZE OF SEMICIRCULAR GUTTERS SHALL BE BASED ON THE | | | MAXIMUM PROJECTED ROOF AREA IN ACCORDANCE WITH TABLE | | | 1106.6. | | | | | | 4D) 2010 FBC-P 1106.2 VERTICAL CONDUCTORS AND LEADERS. | | | VERTICAL CONDUCTORS AND LEADERS SHALL BE SIZED FOR THE | | | MAXIMUM PROJECTED ROOF AREA, IN ACCORDANCE WITH TABLES | | | 1106.2(1) AND 1106.2(2). | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | | REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL | | | LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH | | | A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE | | | SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE | | | FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR | | | YOUR ANTICIPATED COOPERATION. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
5 |
Status |
P |
Date |
2014-12-23 |
|
|
Cont ID |
|
| Sent By |
DKITTRED |
Date |
2014-12-23 |
Time |
13:58 |
Rev Time |
0.00 |
| Received By |
dkittred |
Date |
2014-12-23 |
Time |
13:18 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
F |
Date |
2014-10-29 |
|
|
Cont ID |
|
| Sent By |
dkittred |
Date |
2014-10-29 |
Time |
08:44 |
Rev Time |
0.00 |
| Received By |
dkittred |
Date |
2014-10-28 |
Time |
16:25 |
Sent To |
|
|
| Notes |
| 2014-11-13 09:18:49 | 11/13/14 - UPDATE - COMMENT REGARDING SUBMITTAL OF A | | | LANDSCAPING PERMIT HAS BEEN ADDRESSED (PERMIT. NO. | | | 14110360). DK | | 2014-10-29 08:44:04 | PLANNING AND ZONING COMMENTS: ***FAILED*** | | | | | | 10/29/14 | | | | | | PREVIOUS COMMENTS FROM ZONING HAVE NOT BEEN ADDRESSED | | | OR ACKNOWLEDGED IN THE RESUBMITTAL. COMMENTS ARE AS | | | FOLLOWS: | | | | | | 1. PREVIOUS COMMENT REGARDING SUBMITTAL OF A SEPARATE | | | LANDSCAPE PERMIT WAS NOT ADDRESSED. PLEASE SUBMIT A | | | SEPARATE LANDSCAPE PERMIT INDICATING WHAT THE PLANTINGS | | | WILL BE IN THE 5 FOOT LANDSCAPE BUFFER. PLEASE SUBMIT A | | | LANDSCAPE PERMIT INDICATING COMPLIANCE WITH THE BUFFER | | | REQUIREMENTS OF ZLDR SEC. 94-443. | | | | | | 2. BUILDING ELEVATIONS SHOW THAT FLOOD LIGHTS ARE BEING | | | PROPOSED ON THE EXTERIOR BUILDINGS, BUT ONLY SURFACE | | | MOUNTED FIXTURES WITH COMPACT FLUORESCENT LAMPS ARE | | | PROPOSED ON THE EXTERIOR OF THE BUILDING PER THE | | | ELECTRICAL PLAN. IF FLOOD LIGHTS ARE BEING PROVIDED ON | | | THE BUILDING A PHOTOMETRIC PLAN WILL NEED TO BE | | | PROVIDED TO DEMONSTRATE COMPLIANCE WITH ZLDR SEC. | | | 94-309 REQUIRING ALL OUTDOOR LIGHTING BE SHIELDED TO | | | REDUCE GLARE AND BE ARRANGED TO REFLECT LIGHT OR GLARE | | | AWAY FROM ADJACENT PUBLIC THOROUGHFARES. | | | | | | 3. ON A PREVIOUS PLAN A TIRE LOFT WAS PROPOSED INSIDE | | | THE BUILDING. THE CURRENT PLAN DOES NOT HAVE A TIRE | | | LOFT. WHERE ARE THE TIRES FOR THE BUSINESS GOING TO BE | | | STORED? | | | | | | 4. ANY PROPOSED SIGNAGE ON THE BUILDING WILL BE | | | REQUIRED TO BE SUBMITTED UNDER A SEPARATE PERMIT. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT: | | | | | | DANIELLE J. KITTREDGE, AICP | | | SENIOR PLANNER | | | PLANNING & ZONING DIVISION | | | PHONE: (561)-822-1443 | | | EMAIL: [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
F |
Date |
2014-09-12 |
|
|
Cont ID |
|
| Sent By |
dkittred |
Date |
2014-09-12 |
Time |
09:35 |
Rev Time |
0.00 |
| Received By |
dkittred |
Date |
2014-09-09 |
Time |
12:20 |
Sent To |
|
|
| Notes |
| 2014-09-12 09:35:49 | PLANNING AND ZONING COMMENTS: ***FAILED*** | | | | | | 9/12/14 | | | | | | 1. PREVIOUS COMMENT REGARDING SUBMITTAL OF A SEPARATE | | | LANDSCAPE PERMIT WAS NOT ADDRESSED. PLEASE SUBMIT A | | | SEPARATE LANDSCAPE PERMIT INDICATING WHAT THE PLANTINGS | | | WILL BE IN THE 5 FOOT LANDSCAPE BUFFER. PLEASE SUBMIT A | | | LANDSCAPE PERMIT INDICATING COMPLIANCE WITH THE BUFFER | | | REQUIREMENTS OF ZLDR SEC. 94-443. | | | | | | 2. BUILDING ELEVATIONS SHOW THAT FLOOD LIGHTS ARE BEING | | | PROPOSED ON THE EXTERIOR BUILDINGS, BUT ONLY SURFACE | | | MOUNTED FIXTURES WITH COMPACT FLUORESCENT LAMPS ARE | | | PROPOSED ON THE EXTERIOR OF THE BUILDING PER THE | | | ELECTRICAL PLAN. IF FLOOD LIGHTS ARE BEING PROVIDED ON | | | THE BUILDING A PHOTOMETRIC PLAN WILL NEED TO BE | | | PROVIDED TO DEMONSTRATE COMPLIANCE WITH ZLDR SEC. | | | 94-309 REQUIRING ALL OUTDOOR LIGHTING BE SHIELDED TO | | | REDUCE GLARE AND BE ARRANGED TO REFLECT LIGHT OR GLARE | | | AWAY FROM ADJACENT PUBLIC THROUGHFARES. | | | | | | 3. ON A PREVIOUS PLAN A TIRE LOFT WAS PROPOSED INSIDE | | | THE BUILDING. THE CURRENT PLAN DOES NOT HAVE A TIRE | | | LOFT. WHERE ARE THE TIRES FOR THE BUSINESS GOING TO BE | | | STORED? | | | | | | 4. ANY PROPOSED SIGNAGE ON THE BUILDING WILL BE | | | REQUIRED TO BE SUBMITTED UNDER A SEPARATE PERMIT. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT: | | | | | | DANIELLE J. KITTREDGE, AICP | | | SENIOR PLANNER | | | PLANNING & ZONING DIVISION | | | PHONE: (561)-822-1443 | | | EMAIL: [email protected] | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2014-04-25 |
|
|
Cont ID |
|
| Sent By |
dkittred |
Date |
2014-04-25 |
Time |
13:59 |
Rev Time |
0.00 |
| Received By |
dkittred |
Date |
2014-04-25 |
Time |
13:59 |
Sent To |
|
|
| Notes |
| 2014-04-25 14:00:53 | PLANNING AND ZONING COMMENTS: ***FAILED*** | | | | | | 4/25/2014 | | | | | | 1. PREVIOUS COMMENT REGARDING SUBMITTAL OF A SEPARATE | | | LANDSCAPE PERMIT WAS NOT ADDRESSED. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT: | | | | | | DANIELLE J. KITTREDGE, AICP | | | SENIOR PLANNER | | | PLANNING & ZONING DIVISION | | | PHONE: (561)-822-1443 | | | EMAIL: [email protected] | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2014-02-10 |
|
|
Cont ID |
|
| Sent By |
aaponte |
Date |
2014-02-10 |
Time |
18:45 |
Rev Time |
0.00 |
| Received By |
dkittred |
Date |
2014-02-10 |
Time |
17:12 |
Sent To |
|
|
| Notes |
| 2014-02-10 18:45:38 | PLANNING AND ZONING COMMENTS: | | | | | | 2/10/14 | | | | | | 1. NO LANDSCAPE PLAN WAS SUBMITTED TO INDICATED WHAT | | | THE PLANTINGS WILL BE IN THE 5 FOOT LANDSCAPE BUFFERS. | | | PLEASE SUBMIT A LANDSCAPE PERMIT INDICATING COMPLIANCE | | | WITH THE BUFFER REQUIREMENTS OF ZLDR SEC. 94-443. | | | | | | 2. THIS REVIEW DOES NOT INCLUDE SIGNAGE. A SEPARATE | | | PERMIT WILL BE REQUIRED FOR SIGNAGE. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT: | | | | | | DANIELLE J. KITTREDGE, AICP | | | SENIOR PLANNER | | | PLANNING & ZONING DIVISION | | | PHONE: (561)-822-1443 | | | EMAIL: [email protected] | | | | | 2014-02-10 16:20:04 | 2/10/14 |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |