Plan Review Details - Permit 14020151
| Plan Review Stops For Permit 14020151 |
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2014-02-24 |
|
|
Cont ID |
|
| Sent By |
albarran |
Date |
2014-02-21 |
Time |
13:43 |
Rev Time |
0.00 |
| Received By |
albarran |
Date |
2014-02-21 |
Time |
13:04 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2014-02-12 |
|
|
Cont ID |
|
| Sent By |
albarran |
Date |
2014-02-12 |
Time |
17:52 |
Rev Time |
0.00 |
| Received By |
albarran |
Date |
2014-02-12 |
Time |
17:46 |
Sent To |
I |
|
| Notes |
| 2014-02-12 18:00:30 | 1. PLEASE PROVIDE A BIT MORE DETAIL OR DESCRIPTION OF | | | THE SCOPE OF WORK. IS THIS THE PRODUCT OF A KITCHEN | | | REMODEL ETC. | | | 2. PROVIDE AN EXPLANATION OF WHAT IS YOUR | | | INTERPRETATION OF A SERVICE CONVERSION. IF YOU ARE | | | CONVERTING FROM AERIAL TO UNDERGROUND, SUBMIT WITH YOUR | | | PLANS A SITE DRAWING REFLECTING BOTH THE METER AND | | | SERVICE POLE. IF THIS IS TO BE SIMPLY A PANEL | | | CONVERSION, STATE ACCORDINGLY AND PROVIDE THE LOCATION | | | OF THE NEW PANEL, MANUFACTURERS BRAND NAME AND LOAD | | | CALC. | | | 3. REPLACEMENT OUTLETS SHALL COMPLY WITH NEC 408.11, BY | | | BEING "TAMPER-RESISTANT" | | | 4. IF A KITCHEN REMODEL PROPER OUTLET PLACEMENT WILL BE | | | REQUIRED. | | | 5. AS PER FBC-R SMOKE DETECTORS SHALL BE REQUIRED. | | | | | | FOR ANY QUESTIONS OR COMMENTS ON THIS REVIEW, PLEASE | | | CONTACT: | | | MIKE ALBARRAN, ELECTRICAL PLANS EXAMINER, PX3353 | | | CITY OF WEST PALM BEACH DEVELOPMENT SERVICES DEPARTMENT | | | PH: (561) 805-6718, EMAIL: [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2014-02-21 |
|
|
Cont ID |
|
| Sent By |
albarran |
Date |
2014-02-21 |
Time |
15:15 |
Rev Time |
0.00 |
| Received By |
albarran |
Date |
2014-02-18 |
Time |
09:56 |
Sent To |
PC |
|
| Notes |
| 2014-02-21 15:14:50 | SAK BOX | | 2014-02-19 09:56:47 | RESUBMITTAL SENT TO ELECTRICAL UNDER $5000 SHELF FOR | | | REVIEW. JG. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2014-02-13 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2014-02-13 |
Time |
09:13 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2014-02-04 |
Time |
15:29 |
Sent To |
|
|
| Notes |
| 2014-02-12 18:00:53 | SAK | | 2014-02-04 15:29:26 | <5000 ELEC |
|
|
|
Account Summary | Usage Policy | Privacy Policy