| Plan Review Stops For Permit 14020021 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2014-02-21 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2014-02-21 |
Time |
10:07 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2014-02-21 |
Time |
10:07 |
Sent To |
|
|
| Notes |
| 2014-02-21 10:07:43 | PROVISO | | | | | | ARCHITECT TO SUBMIT LETTER - | | | | | | FENCE/GATE TO MEET POOL BARRIER REQUIREMENTS | | | | | | PROPOSED IMPROVEMENT HAS BEEN DESIGNED TO RESIST | | | FLOTATION AND FLOOD LOADS | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2014-02-19 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2014-02-19 |
Time |
09:11 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2014-02-19 |
Time |
09:11 |
Sent To |
|
|
| Notes |
| 2014-02-19 10:47:10 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | COMMENTS FROM PREVIOUS LIST: | | | | | | 1.OK | | | | | | 3. PROPOSED SECOND FLOOR PLAN NOT CLEAR. A DOOR OR GATE | | | IS SHOWN BETWEEN THE TWO BUILDINGS. ARE THESE BUILDINGS | | | CONNECTED? WHERE DOES THE DOOR/GATE LEAD TO? | | | | | | 2ND REVIEW, IT APPEARS THAT THE GATE IS A PART OF THE | | | POOL BARRIER. PLEASE SEE FBC 2010 RESIDENTIAL | | | 4101.17.1.8 OR REVISE PLAN TO SHOW THAT THE PROPOSED | | | GATE IS NOT A PART OF THE POOL BARRIER. | | | | | | 4-6. OK | | | | | | 7. THIS PARCEL IS LOCATED IN FLOOD ZONE A5. PROVIDE A | | | COPY OF THE ELEVATION CERTIFICATE OR PROVIDE MORE | | | INFORMATION AS TO HOW THIS PROPOSED IMPROVEMENT WILL | | | MEET THE REQUIREMENTS OF R322.1.2. ELEVATION | | | CERTIFICATE MAY BE SENT VIA EMAIL SO THAT PLAN REVIEW | | | CAN BE COMPLETED AT THIS TIME. | | | | | | ELEVATION CERTIFICATE RECEIVED. AS THE PROPOSED | | | IMPROVEMENT IS BELOW THE BFE + FREEBOARD (7' + 6"), | | | REVISE PLAN TO INCLUDE DESIGN CRITERIA TO MEET | | | REQUIRMENTS OF 322.1.2. IT APPEARS THAT THE | | | STAIRS/LANDING/WALL FOOTING ARE BELOW 5'. | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2014-02-03 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2014-02-03 |
Time |
17:42 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2014-02-03 |
Time |
17:42 |
Sent To |
|
|
| Notes |
| 2014-02-03 18:10:09 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | 1. SHEET A1.0, FLOOR PLANS MAKE REFERENCE TO DD A1.2, | | | SHEET A1.2 NOT SUBMITTED. PLEASE CORRELATE. | | | | | | 2. PLAN REFERS TO STRUCTURAL DRAWINGS, BUT STRUCTURAL | | | DRAWINGS WERE NOT SUBMITTED. | | | | | | 3. PROPOSED SECOND FLOOR PLAN NOT CLEAR. A DOOR OR GATE | | | IS SHOWN BETWEEN THE TWO BUILDINGS. ARE THESE BUILDINGS | | | CONNECTED? WHERE DOES THE DOOR/GATE LEAD TO? | | | | | | 4. PROPOSED WALL LENGTH IS NOT CLEAR. COVER SHEET SITE | | | PLAN APPEARS TO SHOW A WALL JOINING THE TWO STRUCTURES. | | | A1.4 SHOWS THE WALL AS THE WIDTH OF THE LANDING. PLEASE | | | CLARIFY. | | | | | | 5. FOOTING SIZE NOT CLEAR; PLAN STATES "AS REQUIRED." | | | REVISE TO SPECIFY. FBC 301. | | | | | | 6. REVISE PLAN TO INCLUDE WIND DESIGN CRITERIA FBC 2010 | | | RESIDENTIAL 301. | | | | | | 7. THIS PARCEL IS LOCATED IN FLOOD ZONE A5. PROVIDE A | | | COPY OF THE ELEVATION CERTIFICATE OR PROVIDE MORE | | | INFORMATION AS TO HOW THIS PROPOSED IMPROVEMENT WILL | | | MEET THE REQUIREMENTS OF R322.1.2. ELEVATION | | | CERTIFICATE MAY BE SENT VIA EMAIL SO THAT PLAN REVIEW | | | CAN BE COMPLETED AT THIS TIME. | | | |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
2 |
Status |
P |
Date |
2014-02-14 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2014-02-14 |
Time |
09:19 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2014-02-14 |
Time |
09:19 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
P |
Date |
2014-02-04 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2014-02-04 |
Time |
16:30 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2014-02-04 |
Time |
16:30 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2014-02-19 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2014-02-19 |
Time |
10:47 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2014-02-10 |
Time |
15:32 |
Sent To |
|
|
| Notes |
| 2014-02-11 15:34:28 | SENT TO ZONING BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2014-02-11 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-02-11 |
Time |
15:56 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2014-02-03 |
Time |
14:15 |
Sent To |
|
|
| Notes |
| 2014-02-03 14:15:11 | TO ZONING | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2014-02-14 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2014-02-14 |
Time |
09:18 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2014-02-14 |
Time |
09:18 |
Sent To |
|
|
| Notes |
| 2014-02-13 12:29:38 | 2/13/14 - ZONING RECEIVED. SENT TO FM FOR Z REVIEW. LL |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2014-02-04 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2014-02-04 |
Time |
16:30 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2014-02-04 |
Time |
10:51 |
Sent To |
|
|
| Notes |
| 2014-02-04 16:31:11 | PLANS ARE NOT CLEAR. ARE THESE BUILDINGS CONNECTED? | | | PLEASE REVISE AND RESUBMIT. FRIEDERIKE MITTNER 822-1457 | | | SPOKE TO NAT HEALY 2/4/14. FILED UNDER DENIED "S". | | 2014-02-04 10:52:06 | 2/4/14 - ZONING RECEIVED. SENT TO FM FOR REVIEW. LL |
|
|