Plan Review Details - Permit 14011764
Plan Review Stops For Permit 14011764
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2014-02-08 Cont ID  
Sent By jwitmer Date 2014-02-08 Time 08:36 Rev Time 0.00
Received By jwitmer Date 2014-02-08 Time 07:45 Sent To  
Notes
2014-02-08 08:36:14 
 BUILDING PLAN REVIEW
 PERMIT: 14011764
 ADD: 4121 PARKER AVE
 CONT: QUALITY HOME TEAM
 TEL: (561)704-1810
  
 2010 FLORIDA BUILDING CODE W
 * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION
 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013.
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
 LEVEL II ALTERATION NOT DECLARED.
  
 1ST REVIEW
 DATE: SATURDAY FEB. 08/2014
 ACTION: DENIED
  
 1) THE DESIGNER OF RECORD HAS NOT INDICATED UNDER WHAT
 METHOD OF DESIGN WAS UNDERTAKEN FOR THIS PLAN AND
 COMPLIANCE WITH:
 2010 FL EXST BLDG. CODE 101.5 COMPLIANCE METHODS.
 THE REPAIR, ALTERATION, CHANGE OF OCCUPANCY, ADDITION
 OR RELOCATION OF ALL EXISTING BUILDINGS SHALL COMPLY
 WITH ONE OF THE METHODS LISTED IN SECTIONS 101.5.1
 THROUGH 101.5.3 AS SELECTED BY THE APPLICANT.
 APPLICATION OF A METHOD SHALL BE THE SOLE BASIS FOR
 ASSESSING THE COMPLIANCE OF WORK PERFORMED UNDER A
 SINGLE PERMIT UNLESS OTHERWISE APPROVED BY THE CODE
 OFFICIAL. SECTIONS 101.5.1 THROUGH 101.5.3 SHALL NOT BE
 APPLIED IN COMBINATION WITH EACH OTHER.
  
 2A) IS THIS A CHANGE OF OCCUPANCY? EXST BUILDING CODE
 CHANGE OF OCCUPANCY. A CHANGE IN THE PURPOSE OR LEVEL
 OF ACTIVITY WITHIN A BUILDING THAT INVOLVES A CHANGE IN
 APPLICATION OF THE REQUIREMENTS OF THIS CODE.
 2B) ARE THERE MORE TENANTS ON THIS FLOOR? TENANT
 SEPERATION WALLS REQUIRE 1 HR SEPERATION IN
 UNSPRINKLERED BUILDINGS. 2010 FBC-B 709.1.6.
  
 3) 705.7 MEANS-OF-EGRESS LIGHTING. MEANS-OF-EGRESS
 LIGHTING SHALL BE IN ACCORDANCE WITH THIS SECTION, AS
 APPLICABLE. 705.7.1 ARTIFICIAL LIGHTING REQUIRED. MEANS
 OF EGRESS IN ALL WORK AREAS SHALL BE PROVIDED WITH
 ARTIFICIAL LIGHTING IN ACCORDANCE WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
 PLEASE PROVIDE EMERGENCY BACK UP LIGHTING TO THE EXIT.
 2010 FBC-B 1006.1.6 SOURCES OF ILLUMINATION. 1006.1.6.2
 BATTERY-OPERATED ELECTRIC LIGHTS AND OTHER TYPES OF
 PORTABLE LAMPS OR LANTERNS SHALL NOT BE USED FOR
 PRIMARY ILLUMINATION OF MEANS OF EGRESS.
 BATTERY-OPERATED ELECTRIC LIGHTS SHALL BE PERMITTED TO
 BE USED AS AN EMERGENCY SOURCE TO THE EXTENT PERMITTED
 UNDER SECTION 1006.2.3.4.
  
 4) PLANS DO NOT INDICATE COMPLIANCE WITH PORTABLE FIRE
 EXTINGUISHERS, 2010 FBC-B EVERY 75'-0" 906.2 GENERAL
 REQUIREMENTS. PORTABLE FIRE EXTINGUISHERS SHALL BE
 SELECTED, INSTALLED AND MAINTAINED IN ACCORDANCE WITH
 THIS SECTION AND NFPA 10.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2014-02-20 Cont ID  
Sent By rlecky Date 2014-02-20 Time 10:51 Rev Time 0.00
Received By rlecky Date 2014-02-20 Time 10:43 Sent To  
Notes
2014-02-20 10:51:01PROVIDE ELECTRIC PLAN SHOWING EXISTING LIGHTING AND
 RECEPTACLES. INCLUDE PANEL SCHEDULE AND ELECTRICAL
 RISER PLAN FOR THE ELECTRIC SERVICE. SHOW LOCATION OF
 ELECTRICAL PANEL BOARD WITH REQUIRED SAFEY CLEARANCES.
 NEC 215.5
  
 ROBERT LECKY, CBO
 ELECTRICAL PLANS REVIEW
  
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2014-02-14 Cont ID  
Sent By wjolin Date 2014-02-14 Time 11:29 Rev Time 0.00
Received By wjolin Date 2014-02-14 Time 11:07 Sent To E
Notes
2014-02-14 11:29:452141 PARKER AVENUE
 PERMIT #14011764
 REVIEW COMMENTS - FIRE DEPARTMENT
  
 THE PARCEL NUMBER (921 ALAMANDA RD) AND PROJECT ADDRESS
 (2141 PARKER AVENUE) ON THE PLANS DO NOT MATCH.
  
 INDICATE THE LOCATIONS OF THE EXISTING EXIT SIGNS.
 ADDITIONAL ILLUMINATED SIGNS MAY BE NEEDED TO ACCOUNT
 FOR THE NEW WALL.
  
 THE PLANS INDICATE NO ELECTRICAL CHANGES HOWEVER, THERE
 ARE NEW FULL AND PARTIAL HEIGHT WALLS BEING INSTALLED.
 INDICATE THE EXISTING CEILING LIGHTING LOCATIONS AND
 ELECTRICAL OUTLETS TO BE UTILIZED FOR THESE NEW SPACES.
  
 WESLEY JOLIN
 ASSISTANT FIRE MARSHAL
 FIRE INVESTIGATOR & INSPECTOR
 OFFICE OF THE FIRE MARSHAL
 WEST PALM BEACH FIRE RESCUE
 [email protected]
 (561) 805-6730
  

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2014-02-20 Cont ID  
Sent By rlecky Date 2014-02-20 Time 10:53 Rev Time 0.00
Received By rlecky Date 2014-01-30 Time 10:43 Sent To  
Notes
2014-01-31 10:43:56INCOMING SENT TO B16 BOX. JW

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2014-02-08 Cont ID  
Sent By jwitmer Date 2014-02-08 Time 08:36 Rev Time 0.00
Received By jwitmer Date 2014-02-08 Time 08:36 Sent To  
Notes
2014-02-08 08:36:59BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT
 FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL
 PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND
 A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT
 APPLICATION. PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]