Plan Review Details - Permit 14011599
| Plan Review Stops For Permit 14011599 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2014-04-28 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2014-04-28 |
Time |
14:31 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2014-04-09 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2014-04-09 |
Time |
16:42 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2014-04-09 |
Time |
16:42 |
Sent To |
|
|
| Notes |
| 2014-04-09 16:49:03 | ****CORRECTIONS**** | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | FBC FLORIDA BUILDING CODE 2010 | | | FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL | | | | | | 1. A CHANGE OF CONTRACTOR FORM WAS SUBMITTED. WHEN | | | RESUBMITTING, PLEASE THIS DONE AT THE FRONT COUNTER. A | | | $100 FEE WILL BE DUE AT THAT TIME. | | | | | | 2. SEE LAST PAGE OF THE NOA, GENERAL LIMITATION #7. | | | CALCULATIONS IN ACCORDANCE WITH RAS117 PREPARED BY AN | | | ARCHITECT, ENGINEER, OR REGISTERED ROOF CONSULTANT. | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2014-02-02 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2014-02-02 |
Time |
11:25 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2014-02-02 |
Time |
11:25 |
Sent To |
|
|
| Notes |
| 2014-02-02 11:27:47 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FBC 2010 RESIDENTIAL 301: | | | | | | 1. APPLICATION PROPOSES TO REPLACE ROOF SHINGLES AND TO | | | DO A REROOF ON A FLAT DECK. | | | | | | THE PRODUCT APPROVAL SUBMITTED IS FOR UNDERLAYMENT. | | | | | | PROVIDE FLORIDA STATE OR LOCAL PRODUCT APPROVAL FOR THE | | | SHINGLES AND FOR THE FLAT DECK. ON THE FLAT DECK | | | PRODUCT APPROVAL, INDICATE WHICH ASSEMBLY IS PROPOSED. | | | IF THE ASSEMBLY DOES NOT MEET WORST CASE DESIGN | | | PRESSURES, PROVIDE INFORMATION REGARDING HOW THE DP | | | REQUIREMENTS FOR ZONES 2 AND 3 AS APPLICABLE WILL BE | | | ADDRESSED. IF ENGINEERING IS REQUIRED BY THE PRODUCT | | | APPROVAL, PROVIDE ENGINEERING. | | | | | | TWO COMPLETE SETS OF DOCUMENTS WILL BE REQUIRED FOR | | | PERMIT ISSUANCE. | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2014-04-09 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2014-04-09 |
Time |
16:49 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2014-04-07 |
Time |
11:20 |
Sent To |
|
|
| Notes |
| 2014-04-08 11:20:50 | SENT TO S HILL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2014-02-02 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2014-02-02 |
Time |
11:30 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |