Plan Review Details - Permit 14011502
| Plan Review Stops For Permit 14011502 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2014-05-20 |
|
|
Cont ID |
|
| Sent By |
JWITMER |
Date |
2014-05-20 |
Time |
20:50 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-05-20 |
Time |
19:31 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2014-04-16 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2014-04-16 |
Time |
18:28 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-04-16 |
Time |
17:03 |
Sent To |
|
|
| Notes |
| 2014-04-16 18:28:05 | BUILDING PLAN REVIEW | | | PERMIT: 14011502 | | | ADD:7915 S DIXIE HWY SUITE # 7731 | | | CONT: SISCA CONSTRUCTION | | | TEL: (561)248-9041 | | | | | | 2010 FLORIDA BUILDING CODE W | | | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | | | 2010 EXISTING BUILDING CODE LEVEL II 701.3 | | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | | | 2ND REVIEW | | | DATE: WED. APRIL 16/ 2014 | | | ACTION: DENIED | | | | | | NOTE: ONE SET OF PLANS ARE MISSING A3.0, A4.0, A5.0, | | | A6.0 & A7.0 SHEETS. | | | | | | 1-5) COMPLIED. | | | | | | 6) 2ND REQUEST PROVIDE MANUFACTURERS CUT SHEETS FOR THE | | | RUBBER MATS, NO NEW A6.0 SHEET. SHEET A3.0 FLOOR | | | COVERINGS INDICATE THE USE OF RUBBER MATS RF-1 & RF-2, | | | PLEASE PROVIDE DOCUMENTATION THESE PRODUCTS ARE IN | | | OCMPLIANCE WITH THE 2010 FBC-B: | | | 804.4 INTERIOR FLOOR FINISH REQUIREMENTS. | | | IN ALL OCCUPANCIES, INTERIOR FLOOR FINISH AND FLOOR | | | COVERING MATERIALS IN EXIT ENCLOSURES, EXIT | | | PASSAGEWAYS, CORRIDORS AND ROOMS OR SPACES NOT | | | SEPARATED FROM CORRIDORS BY FULL-HEIGHT PARTITIONS | | | EXTENDING FROM THE FLOOR TO THE UNDERSIDE OF THE | | | CEILING SHALL WITHSTAND A MINIMUM CRITICAL RADIANT FLUX | | | AS SPECIFIED IN SECTION 804.4.1. | | | | | | 804.4.1 MINIMUM CRITICAL RADIANT FLUX. | | | INTERIOR FLOOR FINISH AND FLOOR COVERING MATERIALS IN | | | EXIT ENCLOSURES, EXIT PASSAGEWAYS AND CORRIDORS SHALL | | | NOT BE LESS THAN CLASS I IN GROUPS I-1, I-2 AND I-3 AND | | | NOT LESS THAN CLASS II IN GROUPS A, B, E, H, M, R-1, | | | R-2 AND S. IN ALL AREAS, FLOOR COVERING MATERIALS SHALL | | | COMPLY WITH THE DOCFF-1 ?PILL TEST? (CPSC 16 CFR, PART | | | 1630). | | | | | | EXCEPTION: WHERE A BUILDING IS EQUIPPED THROUGHOUT WITH | | | AN AUTOMATIC SPRINKLER SYSTEM IN ACCORDANCE WITH | | | SECTION 903.3.1.1 OR 903.3.1.2, CLASS II MATERIALS ARE | | | PERMITTED IN ANY AREA WHERE CLASS I MATERIALS ARE | | | REQUIRED, AND MATERIALS COMPLYING WITH THE DOC FF-1 | | | ?PILL TEST? (CPSC 16 CFR, PART 1630) ARE PERMITTED IN | | | ANY AREA WHERE CLASS II MATERIALS ARE REQUIRED. | | | | | | 7-8) COMPLIED | | | | | | 9) BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL | | | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND | | | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT | | | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2014-02-06 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2014-02-06 |
Time |
08:14 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-02-06 |
Time |
05:29 |
Sent To |
|
|
| Notes |
| 2014-02-06 06:03:18 | BUILDING PLAN REVIEW | | | PERMIT: 14011502 | | | ADD:7915 S DIXIE HWY SUITE # 7731 | | | CONT: SISCA CONSTRUCTION | | | TEL: (561)248-9041 | | | | | | 2010 FLORIDA BUILDING CODE W | | | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | | | 2010 EXISTING BUILDING CODE LEVEL II 701.3 | | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | | | 1ST REVIEW | | | DATE: THURS. FEB. 06/ 2014 | | | ACTION: DENIED | | | | | | NOTE: ONE SET OF PLANS ARE MISSING A3.0, A4.0, A5.0, | | | A6.0 & A7.0 SHEETS. | | | | | | 1-5) COMPLIED. | | | | | | 6) 2ND REQUEST PROVIDE MANUFACTURERS CUT SHEETS FOR THE | | | RUBBER MATS, NO NEW A6.0 SHEET. SHEET A3.0 FLOOR | | | COVERINGS INDICATE THE USE OF RUBBER MATS RF-1 & RF-2, | | | PLEASE PROVIDE DOCUMENTATION THESE PRODUCTS ARE IN | | | OCMPLIANCE WITH THE 2010 FBC-B: | | | 804.4 INTERIOR FLOOR FINISH REQUIREMENTS. | | | IN ALL OCCUPANCIES, INTERIOR FLOOR FINISH AND FLOOR | | | COVERING MATERIALS IN EXIT ENCLOSURES, EXIT | | | PASSAGEWAYS, CORRIDORS AND ROOMS OR SPACES NOT | | | SEPARATED FROM CORRIDORS BY FULL-HEIGHT PARTITIONS | | | EXTENDING FROM THE FLOOR TO THE UNDERSIDE OF THE | | | CEILING SHALL WITHSTAND A MINIMUM CRITICAL RADIANT FLUX | | | AS SPECIFIED IN SECTION 804.4.1. | | | | | | 804.4.1 MINIMUM CRITICAL RADIANT FLUX. | | | INTERIOR FLOOR FINISH AND FLOOR COVERING MATERIALS IN | | | EXIT ENCLOSURES, EXIT PASSAGEWAYS AND CORRIDORS SHALL | | | NOT BE LESS THAN CLASS I IN GROUPS I-1, I-2 AND I-3 AND | | | NOT LESS THAN CLASS II IN GROUPS A, B, E, H, M, R-1, | | | R-2 AND S. IN ALL AREAS, FLOOR COVERING MATERIALS SHALL | | | COMPLY WITH THE DOCFF-1 ?PILL TEST? (CPSC 16 CFR, PART | | | 1630). | | | | | | EXCEPTION: WHERE A BUILDING IS EQUIPPED THROUGHOUT WITH | | | AN AUTOMATIC SPRINKLER SYSTEM IN ACCORDANCE WITH | | | SECTION 903.3.1.1 OR 903.3.1.2, CLASS II MATERIALS ARE | | | PERMITTED IN ANY AREA WHERE CLASS I MATERIALS ARE | | | REQUIRED, AND MATERIALS COMPLYING WITH THE DOC FF-1 | | | ?PILL TEST? (CPSC 16 CFR, PART 1630) ARE PERMITTED IN | | | ANY AREA WHERE CLASS II MATERIALS ARE REQUIRED. | | | | | | 7-8) COMPLIED | | | | | | 9) BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL | | | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND | | | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT | | | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | 10) WHEN RESUBMITTING PLANS PLEASE INDICATE THE | | | REVISION & REMOVE & REPLACE ANY PAGES AS NECESSARY. A | | | TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT | | | NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE THE | | | CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | CONSTRUCTION SERVICES HOME PAGE | | | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP | | | | | | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS | | | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS | | | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO | | | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE | | | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. | | | | | | MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF | | | FLORIDA SAVING LIVES AND PROPERTY SINCE 1953 | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2014-05-27 |
|
|
Cont ID |
|
| Sent By |
DHARVEY |
Date |
2014-05-27 |
Time |
19:11 |
Rev Time |
0.00 |
| Received By |
albarran |
Date |
2014-05-27 |
Time |
18:27 |
Sent To |
I |
|
| Notes |
| 2014-05-27 19:12:33 | ELECTRICAL PROVISO: PERMIT 14011502 | | | BECAUSE ALL THESE SERVICES ARE EXISTING STRICT CODE | | | COMPLIANCE IS NOT BEING MANDATED, BUT IN THE INTEREST | | | OF LIFE SAFETY ALL SERVICES DEVIATING FROM NEC 230.2 OR | | | NEC 230.3 SHALL BE PERMANENTLY LABELED TO INDICATE | | | AREAS SERVED. | | | THESE PLANS WERE REVIEWED BY MIKE ALBARRAN, ELECTRICAL | | | PLANS EXAMINER | | | YOU ARE WELCOME TO REVIEW STATUS OR COMMENTS AT THE | | | FOLLOWING LINK: | | | | | | HTTP://ONESTOPSHOP.WPBGOV.COM/EGOVPLUS/PERMIT/PERM_STAT | | | US.ASPX | | | | | | ENTER YOUR PERMIT NUMBER (SEE SUBJECT LINE OF THIS | | | EMAIL FOR YOUR PERMIT #), CLICK ON THE PERMIT NUMBER, | | | AND THEN GO TO "PLAN REVIEWS" TO SEE YOUR COMMENTS (TAB | | | ABOVE THE SECOND PERMIT INFORMATION). | | | AFTER ISSUANCE, PLEASE CHECK YOUR PLAN CAREFULLY FOR | | | COMPLIANCE WITH ANY REDLINES, NOTES, PROVISOS, OR OTHER | | | PERMIT CONDITIONS. | | | FOR FURTHER ASSISTANCE, PLEASE FEEL FREE TO CONTACT ME. | | | I CAN BE REACHED AT 561-805-6718 OR | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2014-04-10 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2014-04-10 |
Time |
14:11 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2014-04-10 |
Time |
13:15 |
Sent To |
|
|
| Notes |
| 2014-04-10 14:20:23 | 14011502 | | | 7731 SOUTH DIXIE | | | PLANET FITNESS | | | 2ND REVIEW | | | | | | PLEASE REVISE THE PLANS IN RESPONSE TO THE FOLLOWING | | | REVIEW COMMENTS. | | | | | | THE ELECTRICAL SERVICE AS NOTED ON SHEET E4.1 INDICATES | | | A 600A, 277/480 VOLT SERVICE WHICH FEEDS AN EXISTING | | | 800A, 120/208 VOLT MDB. REVISE PLANS TO SHOW CORRECT | | | VOLTAGE AND PHASE. NEC 215.5 | | | | | | THE PLANS ARE NOT CLEAR REGARDING THE LIMITATIONS | | | PROVIDED WITHIN THE CODE FOR THE NUMBER OF SERVICES | | | ALLOWED TO THE BUILDING AND THE LOCATIONS OF THE MAIN | | | DISCONNECTS FOR THE EXISTING AND NEW OCCUPANCIES. FIRE | | | SEPARATIONS ARE ONE METHOD TO PROVIDE SEPARATION WITHIN | | | STRUCTURES FOR OCCUPANCIES REQUIRING THEIR OWN ELECTRIC | | | SERVICE. THE PLAN NEEDS TO VERIFY THAT THERE IS ONLY | | | ONE POINT OF SERVICE TO EACH BUILDING AND THAT THE | | | ELECTRICAL SERVICE MAINS FOR EACH SERVICE ARE SIX OR | | | LESS AND GROUPED IN ONE LOCATION. NEC 230.2, 230.71, | | | 230.72 | | | | | | | | | NOTE: SEPARATE PERMITS AND PLANS ARE REQUIRED FOR, FIRE | | | ALARM SYSTEMS, SECURITY AND DATA SYSTEMS. | | | | | | | | | ROBERT LECKY | | | ELECTRICAL PLANS REVIEW | | | 561-373-3701 | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2014-02-05 |
|
|
Cont ID |
|
| Sent By |
dharvey |
Date |
2014-02-05 |
Time |
12:43 |
Rev Time |
0.00 |
| Received By |
dharvey |
Date |
2014-02-05 |
Time |
10:37 |
Sent To |
|
|
| Notes |
| 2014-02-05 10:37:24 | 14011502 | | | 7731 SOUTH DIXIE | | | PLANET FITNESS | | | | | | PLEASE REVISE THE PLANS IN RESPONSE TO THE FOLLOWING | | | REVIEW COMMENTS. | | | | | | PROVIDE A SAFETY LABELING SCHEDULE FOR FLASH PROTECTION | | | FOR THE SERVICE, PANEL BOARDS AND MAIN DISCONNECTING | | | MEANS. NEC 110.22, 110.16, 110.22 | | | | | | PROVIDE DIMENSIONS FOR THE DESIGNATED CLEAR WORKING | | | SPACES REQUIRED AROUND THE ELECTRICAL SERVICE EQUIPMENT | | | AND PANEL BOARDS. NEC 215.5, 110.26 | | | | | | VERIFY THE EXISTING ELECTRICAL MDP HAS A FAULT CURRENT | | | RATING THAT IS SUFFICIENT AT NOMINAL CIRCUIT VOLTAGE | | | FOR THE CURRENT THAT MUST BE INTERRUPTED. NEC 110.9 | | | | | | VERIFY THE REQUIRED GFCI PROTECTED RECEPTACLE IS | | | AVAILABLE TO SERVICE ROOF TOP MECHANICAL EQUIPMENT. NEC | | | 210.8(B) | | | PROVIDE A STRUCTURAL DETAIL FOR HANGING THE B.A. FANS | | | AND TVS FROM THE EXISTING STRUCTURE. FBC 1604.1 | | | | | | PROVIDE A KEY PLAN SHOWING OCCUPANCY LOCATION WITH | | | ADJACENT TENANTS. INDICATE LOCATION OF ALL EXISTING OR | | | PROPOSED ELECTRICAL SERVICES WITH MAIN DISCONNECTS | | | SERVING THE PLAZA. NEC 230.2, 230.7 | | | | | | PROVIDE A LIGHTING DENSITY SUMMARY ON THE PLAN SHOWING | | | COMPLIANCE WITH THE FLORIDA BUILDING ENERGY CODE | | | REQUIREMENTS. FBC ENERGY CONSERVATION 505.3 | | | | | | NOTE: SEPARATE PERMITS AND PLANS ARE REQUIRED FOR, FIRE | | | ALARM, SECURITY AND DATA SYSTEMS. | | | | | | ROBERT LECKY | | | ELECTRICAL PLANS REVIEW | | | 561-373-3701 | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2014-05-19 |
|
|
Cont ID |
|
| Sent By |
WJOLIN |
Date |
2014-05-19 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2014-05-19 |
Time |
14:55 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
2014-04-17 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2014-04-17 |
Time |
15:47 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2014-04-17 |
Time |
15:04 |
Sent To |
|
|
| Notes |
| 2014-04-17 15:42:11 | 7731 SOUTH DIXIE HIGHWAY | | | PERMIT #14011502 | | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | | | RESPONSE COMMENT: THE ASTM E648 TEST RESULTS (CRITICAL | | | RADIANT FLUX) ARE FOR "ULTIMATE SYSTEMS LTD" FLOORING; | | | HOWEVER, SHEET A6.0 STILL INDICATES "EVERLAST" AND | | | "ECORE" FLOORING COMPANIES. | | | ORIGINAL COMMENT - SHEET A6.0: FLOOR COVERINGS (RUBBER | | | FLOORING), OTHER THAN CARPET, THAT MAY REPRESENT AN | | | UNUSUAL HAZARD SHALL HAVE A CRITICAL RADIANT FLUX OF AT | | | LEAST 0.1 W/CM2 (RESISTANCE TO FLAME PROPAGATION) AS | | | PER NFPA 253. | | | | | | REPEAT COMMENT - SHEET A6.0: FINISH GB-2 INDICATES SOME | | | SORT OF STYROFOAM. THE INTERIOR FINISH MATERIALS FOR | | | WALLS AND CEILINGS SHALL MEET THE SMOKE DEVELOPMENT | | | (0-450) AND FLAME SPREAD (76-200) REQUIREMENTS FOR | | | CLASS C INTERIOR FINISHES PER NFPA 101. | | | | | | REPEAT COMMENT - GENERAL: PROVIDE AN EXTERIOR KEY SAFE | | | TO ALLOW EMERGENCY RESPONDERS NON-FORCIBLE ENTRY INTO | | | THE BUILDING DURING NON-BUSINESS HOURS. A KEY SAFE CAN | | | BE ORDERED FROM WWW.KNOXBOX.COM. | | | | | | REPEAT COMMENT - GENERAL: PROVIDE DRAWING NOTE | | | INDICATING ALL CONSTRUCTION AND DEMOLITION WORK SHALL | | | CONFORM TO THE REQUIREMENTS OF NFPA 241. TRASH AND | | | CONSTRUCTION DEBRIS SHALL BE REMOVED FROM THE SITE | | | DAILY. SMOKING SHALL BE PROHIBITED EXCEPT IN DESIGNATED | | | EXTERIOR AREAS. ALL OTHER DEMOLITION OR CONSTRUCTION | | | AREAS SHALL HAVE "NO SMOKING" SIGNS POSTED. WHERE | | | SMOKING IS PERMITTED, SAFE RECEPTACLES FOR SMOKING | | | MATERIALS SHALL BE PROVIDED. | | | | | | REPEAT COMMENT - GENERAL: PROVIDE DRAWING NOTE | | | INDICATING, "FIRE PROTECTION SYSTEMS SHALL REMAIN | | | ACTIVE DURING DEMOLITION AND RENOVATION ACTIVITIES. IN | | | THE EVENT A FIRE PROTECTION SYSTEM IS OUT OF SERVICE | | | FOR MORE THAN 4-HOURS IN A 24-HOUR PERIOD, THE BUILDING | | | SHALL BE PLACED UNDER A FIRE WATCH. ALL FIRE WATCH | | | REQUESTS MUST BE SUBMITTED BY EMAIL ([email protected]) OR | | | IN WRITING (FAX: 561-804-4774) AND APPROVED BY THE | | | OFFICE OF THE FIRE MARSHAL LOCATED AT 500 NORTH DIXIE | | | HIGHWAY." | | | | | | REPEAT COMMENT - GENERAL: FOR ISSUANCE OF A GENERAL | | | BUILDING PERMIT, SECTION 105.3.1.2(2) OF THE FLORIDA | | | BUILDING CODE REQUIRES SEALED FIRE PROTECTION | | | CONSTRUCTION DOCUMENTS FOR THE DESIGN OR ALTERATION OF | | | 50 OR MORE AUTOMATIC FIRE SPRINKLERS. AFTER THE | | | BUILDING PERMIT HAS BEEN ISSUED, THE SUBCONTRACTORS CAN | | | THEN SUBMIT SHOP DRAWINGS (CONFORMING TO THE ENGINEERED | | | CONSTRUCTION DOCUMENTS) FOR A SUB-PERMIT. | | | | | | WESLEY JOLIN | | | ASSISTANT FIRE MARSHAL | | | FIRE INVESTIGATOR & INSPECTOR | | | OFFICE OF THE FIRE MARSHAL | | | WEST PALM BEACH FIRE RESCUE | | | [email protected] | | | (561) 805-6730 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2014-01-29 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2014-01-29 |
Time |
16:45 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2014-01-29 |
Time |
15:54 |
Sent To |
|
|
| Notes |
| 2014-01-29 16:45:25 | 7731 SOUTH DIXIE HIGHWAY | | | PERMIT #14011502 | | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | | | SHEET A6.0: FINISH GB-2 INDICATES SOME SORT OF | | | STYROFOAM. THE INTERIOR FINISH MATERIALS FOR WALLS AND | | | CEILINGS SHALL MEET THE SMOKE DEVELOPMENT (0-450) AND | | | FLAME SPREAD (76-200) REQUIREMENTS FOR CLASS C INTERIOR | | | FINISHES PER NFPA 101. | | | | | | SHEET A6.0: FLOOR COVERINGS (RUBBER FLOORING), OTHER | | | THAN CARPET, THAT MAY REPRESENT AN UNUSUAL HAZARD SHALL | | | HAVE A CRITICAL RADIANT FLUX OF AT LEAST 0.1 W/CM2 | | | (RESISTANCE TO FLAME PROPAGATION) AS PER NFPA 253. | | | | | | GENERAL: PROVIDE AN EXTERIOR KEY SAFE TO ALLOW | | | EMERGENCY RESPONDERS NON-FORCIBLE ENTRY INTO THE | | | BUILDING DURING NON-BUSINESS HOURS. A KEY SAFE CAN BE | | | ORDERED FROM WWW.KNOXBOX.COM. | | | | | | GENERAL: PROVIDE DRAWING NOTE INDICATING ALL | | | CONSTRUCTION AND DEMOLITION WORK SHALL CONFORM TO THE | | | REQUIREMENTS OF NFPA 241. TRASH AND CONSTRUCTION DEBRIS | | | SHALL BE REMOVED FROM THE SITE DAILY. SMOKING SHALL BE | | | PROHIBITED EXCEPT IN DESIGNATED EXTERIOR AREAS. ALL | | | OTHER DEMOLITION OR CONSTRUCTION AREAS SHALL HAVE "NO | | | SMOKING" SIGNS POSTED. WHERE SMOKING IS PERMITTED, SAFE | | | RECEPTACLES FOR SMOKING MATERIALS SHALL BE PROVIDED. | | | | | | GENERAL: PROVIDE DRAWING NOTE INDICATING, "FIRE | | | PROTECTION SYSTEMS SHALL REMAIN ACTIVE DURING | | | DEMOLITION AND RENOVATION ACTIVITIES. IN THE EVENT A | | | FIRE PROTECTION SYSTEM IS OUT OF SERVICE FOR MORE THAN | | | 4-HOURS IN A 24-HOUR PERIOD, THE BUILDING SHALL BE | | | PLACED UNDER A FIRE WATCH. ALL FIRE WATCH REQUESTS MUST | | | BE SUBMITTED BY EMAIL ([email protected]) OR IN WRITING | | | (FAX: 561-804-4774) AND APPROVED BY THE OFFICE OF THE | | | FIRE MARSHAL LOCATED AT 500 NORTH DIXIE HIGHWAY." | | | | | | GENERAL: PROVIDE TACTILE SIGNAGE AT ALL REQUIRED EXIT | | | DOORS WITH EXIT SIGNS. | | | | | | GENERAL: FOR ISSUANCE OF A GENERAL BUILDING PERMIT, | | | SECTION 105.3.1.2(2) OF THE FLORIDA BUILDING CODE | | | REQUIRES SEALED FIRE PROTECTION CONSTRUCTION DOCUMENTS | | | FOR THE DESIGN OR ALTERATION OF 50 OR MORE AUTOMATIC | | | FIRE SPRINKLERS. AFTER THE BUILDING PERMIT HAS BEEN | | | ISSUED, THE SUBCONTRACTORS CAN THEN SUBMIT SHOP | | | DRAWINGS (CONFORMING TO THE ENGINEERED CONSTRUCTION | | | DOCUMENTS) FOR A SUB-PERMIT. | | | | | | WESLEY JOLIN | | | ASSISTANT FIRE MARSHAL | | | FIRE INVESTIGATOR & INSPECTOR | | | OFFICE OF THE FIRE MARSHAL | | | WEST PALM BEACH FIRE RESCUE | | | [email protected] | | | (561) 805-6730 | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
3 |
Status |
P |
Date |
2014-05-20 |
|
|
Cont ID |
|
| Sent By |
JWITMER |
Date |
2014-05-20 |
Time |
20:36 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-05-20 |
Time |
19:51 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
F |
Date |
2014-04-16 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2014-04-16 |
Time |
19:13 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-04-16 |
Time |
18:29 |
Sent To |
|
|
| Notes |
| 2014-04-16 18:53:21 | GAS PLAN REVIEW | | | PERMIT: 14011502 | | | ADD:7915 S DIXIE HWY SUITE # 7731 | | | CONT: SISCA CONSTRUCTION | | | TEL: (561)248-9041 | | | | | | 2010 FLORIDA BUILDING CODE W | | | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | | | 2010 EXISTING BUILDING CODE LEVEL II 701.3 | | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | | | 2ND REVIEW | | | DATE: WED. APRIL 16/ 2014 | | | ACTION: DENIED | | | | | | A THOROUGH REVIEW CAN NOT BE MADE AT THIS TIME, AS A | | | RESULT OF THE ADDITIONAL INFORMATION REQUESTED | | | ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF | | | THIS REVIEW. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | | REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL | | | LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH | | | A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE | | | SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE | | | FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR | | | YOUR ANTICIPATED COOPERATION. | | | | | | | | | | | | GAS PLAN REVIEW NOT SUFFICIENT DOCUMENTATION FOR PLAN | | | REVIEW. | | | 1. SUBMIT AN ISOMETRIC DRAWING THAT CLEARLY SHOWS ALL | | | CUT SECTIONS OF PIPE AND CORRESPONDING LENGTHS PER | | | FBC-2010 FUEL GAS. | | | | | | 2. SHOW TYPE OF PIPING MATERIAL BEING INSTALLED, ALL | | | PIPE SIZES, AND THE EDH NUMBER OF CORRUGATED STAINLESS | | | STEEL TUBING FOR EACH PIPE SIZE IF BEING USED. FUEL GAS | | | 402.3. | | | | | | 3. TYPE OF GAS, (LP OR NATURAL). | | | | | | 4. BTU LOAD OF EACH APPLIANCE AND THE TOTAL BTU LOAD ON | | | THE SYSTEM. REFER TO THE FBC-2010 FUEL GAS SECS. 401.8 | | | THRU 402.6.1 AND TABLES 402.4(1) THRU 402.4(35) | | | | | | 5. SHOW THE DISTANCE FROM THE POINT OF DELIVERY, | | | (METER), TO THE MOST REMOTE OUTLET IN THE BUILDING | | | AND/OR SYSTEM PER THE FBC-2010 FUEL GAS APPENDIX A ? | | | USE OF CAPACITY SECTION A.3.1(4) | | | | | | 6. SUBMIT CALCULATIONS FOR COMBUSTION AIR PER THE | | | FBC-2010 FUEL GAS CODE SEC. 304 | | | | | | 7. INDICATE THE DELIVERY PRESSURE (PSI) PER FBC-2010 | | | FUEL GAS SEC. 402.2. IF NATURAL GAS SPECIFY .5 PSI OR 2 | | | PSI. | | | | | | 8. SUBMIT A DETAIL SHOWING THE TYPE, LOCATION, SIZE AND | | | TERMINATION OF THE GAS VENTS PER FBC-2010 FUEL GAS CODE | | | SEC. 502 THRU 505. | | | | | | | | | 9. SUBMIT MANUFACTURE SHEETS FOR ALL GAS EQUIPMENT TO | | | VERIFY COMPLIANCE WITH STANDARDS NFPA 54, NFPA 58, AND | | | FBC-2010 FUEL GAS SEC. 402.2 | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | DEVELOPMENT SERVICES HOME PAGE | | | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP | | | | | | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS | | | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS | | | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO | | | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE | | | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. | | | | | | MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF | | | FLORIDA SAVING LIVES AND PROPERTY SINCE 1953 | | | | | | | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2014-02-07 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2014-02-07 |
Time |
14:11 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-02-07 |
Time |
14:11 |
Sent To |
|
|
| Notes |
| 2014-02-07 14:29:14 | GAS PLAN REVIEW | | | PERMIT: 14011502 | | | ADD:7915 S DIXIE HWY SUITE # 7731 | | | CONT: SISCA CONSTRUCTION | | | TEL: (561)248-9041 | | | | | | 2010 FLORIDA BUILDING CODE W | | | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | | | 2010 EXISTING BUILDING CODE LEVEL II 701.3 | | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | | | 1ST REVIEW | | | DATE: FRI> . FEB. 07/ 2014 | | | ACTION: DENIED | | | | | | GAS PLAN REVIEW NOT SUFFICIENT DOCUMENTATION FOR PLAN | | | REVIEW. | | | 1. SUBMIT AN ISOMETRIC DRAWING THAT CLEARLY SHOWS ALL | | | CUT SECTIONS OF PIPE AND CORRESPONDING LENGTHS PER | | | FBC-2010 FUEL GAS. | | | | | | 2. SHOW TYPE OF PIPING MATERIAL BEING INSTALLED, ALL | | | PIPE SIZES, AND THE EDH NUMBER OF CORRUGATED STAINLESS | | | STEEL TUBING FOR EACH PIPE SIZE IF BEING USED. FUEL GAS | | | 402.3. | | | | | | 3. TYPE OF GAS, (LP OR NATURAL). | | | | | | 4. BTU LOAD OF EACH APPLIANCE AND THE TOTAL BTU LOAD ON | | | THE SYSTEM. REFER TO THE FBC-2010 FUEL GAS SECS. 401.8 | | | THRU 402.6.1 AND TABLES 402.4(1) THRU 402.4(35) | | | | | | 5. SHOW THE DISTANCE FROM THE POINT OF DELIVERY, | | | (METER), TO THE MOST REMOTE OUTLET IN THE BUILDING | | | AND/OR SYSTEM PER THE FBC-2010 FUEL GAS APPENDIX A ? | | | USE OF CAPACITY SECTION A.3.1(4) | | | | | | 6. SUBMIT CALCULATIONS FOR COMBUSTION AIR PER THE | | | FBC-2010 FUEL GAS CODE SEC. 304 | | | | | | 7. INDICATE THE DELIVERY PRESSURE (PSI) PER FBC-2010 | | | FUEL GAS SEC. 402.2. IF NATURAL GAS SPECIFY .5 PSI OR 2 | | | PSI. | | | | | | 8. SUBMIT A DETAIL SHOWING THE TYPE, LOCATION, SIZE AND | | | TERMINATION OF THE GAS VENTS PER FBC-2010 FUEL GAS CODE | | | SEC. 502 THRU 505. | | | | | | | | | 9. SUBMIT MANUFACTURE SHEETS FOR ALL GAS EQUIPMENT TO | | | VERIFY COMPLIANCE WITH STANDARDS NFPA 54, NFPA 58, AND | | | FBC-2010 FUEL GAS SEC. 402.2 | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | DEVELOPMENT SERVICES HOME PAGE | | | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP | | | | | | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS | | | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS | | | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO | | | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE | | | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. | | | | | | MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF | | | FLORIDA SAVING LIVES AND PROPERTY SINCE 1953 | | | | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2014-05-27 |
|
|
Cont ID |
|
| Sent By |
albarran |
Date |
2014-05-27 |
Time |
19:12 |
Rev Time |
0.00 |
| Received By |
albarran |
Date |
2014-05-12 |
Time |
17:35 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2014-04-21 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2014-04-21 |
Time |
13:24 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2014-04-09 |
Time |
08:35 |
Sent To |
|
|
| Notes |
| 2014-04-09 08:37:00 | INCOMING SENT TO B-13. JW |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2014-02-26 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2014-02-26 |
Time |
11:43 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2014-01-27 |
Time |
09:56 |
Sent To |
|
|
| Notes |
| 2014-01-28 09:57:02 | SENT TO B9 SHELF FOR REVIEW. JG. |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
N |
Date |
2014-05-20 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2014-05-20 |
Time |
20:13 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-05-20 |
Time |
20:13 |
Sent To |
|
|
| Notes |
| 2014-05-20 20:14:14 | PB COUNTY IMPACT FEE OFFICE- STAMPED NO FEES DUE. JW |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2014-02-07 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2014-02-07 |
Time |
14:57 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-02-07 |
Time |
14:57 |
Sent To |
|
|
| Notes |
| 2014-02-07 14:57:21 | BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL | | | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND | | | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT | | | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | CONSTRUCTION SERVICES HOME PAGE | | | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2014-04-21 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2014-04-21 |
Time |
13:24 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2014-04-21 |
Time |
13:11 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2014-02-25 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2014-02-25 |
Time |
15:26 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2014-02-25 |
Time |
15:01 |
Sent To |
|
|
| Notes |
| 2014-02-25 15:26:53 | PLAN DENIED | | | 1) PROVIDE A DETAIL FROM THE ENGINEER ON THE | | | RTU CURB TIE DOWN TO THE ROOF AND THE RTU | | | TO CURB TIE DOWN. PROVIDE THE SIZE AND SPACE | | | OF THE FASTENER USED. PROVIDE THE TYPE OF FASTENERS | | | USED. SAME FOR CENTRIFUGAL FAN ANCHORED TO THE ROOF. | | | PER SECTION 301.12 WIND RESISTANCE.2010 FBC (M) | | | PLAN REVIEW BY HAROLD MOSER | | | [email protected] | | | OFFICE 561-805-6732 | | | FAX 561-805-6676 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2014-05-20 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2014-05-20 |
Time |
20:36 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-05-20 |
Time |
19:41 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2014-04-16 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2014-04-16 |
Time |
18:29 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-04-16 |
Time |
18:28 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2014-02-07 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2014-02-07 |
Time |
14:56 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-02-07 |
Time |
14:09 |
Sent To |
|
|
| Notes |
| 2014-02-07 14:56:07 | PLUMBING PLAN REVIEW | | | PERMIT: 14011502 | | | ADD:7915 S DIXIE HWY SUITE # 7731 | | | CONT: SISCA CONSTRUCTION | | | TEL: (561)248-9041 | | | | | | 2010 FLORIDA BUILDING CODE W | | | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | | | 2010 EXISTING BUILDING CODE LEVEL II 701.3 | | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | | | 1ST REVIEW | | | DATE: FRI. FEB. 07/ 2014 | | | ACTION: DENIED | | | | | | 1) PROVIDE THE MANUFACTURERS SPECIFICATION FOR THE | | | LASCO ADA SHOWER, PLEASE PROVIDE COMPLIANCE WITH | | | THE2010 FL ACCESSIBLE REQUIREMENTS: | | | 608.2.1 TRANSFER TYPE SHOWER COMPARTMENTS. | | | TRANSFER TYPE SHOWER COMPARTMENTS SHALL BE 36 INCHES | | | (915 MM) BY 36 INCHES (915 MM) CLEAR INSIDE DIMENSIONS | | | MEASURED AT THE CENTER POINTS OF OPPOSING SIDES AND | | | SHALL HAVE A 36 INCH (915 MM) WIDE MINIMUM ENTRY ON THE | | | FACE OF THE SHOWER COMPARTMENT. CLEARANCE OF 36 INCHES | | | (915 MM) WIDE MINIMUM BY 48 INCHES (1220 MM) LONG | | | MINIMUM MEASURED FROM THE CONTROL WALL SHALL BE | | | PROVIDED. | | | | | | 2) 608.5.1 TRANSFER TYPE SHOWER COMPARTMENTS. | | | IN TRANSFER TYPE SHOWER COMPARTMENTS, THE CONTROLS, | | | FAUCETS, AND SHOWER SPRAY UNIT SHALL BE INSTALLED ON | | | THE SIDE WALL OPPOSITE THE SEAT 38 INCHES (965 MM) | | | MINIMUM AND 48 INCHES (1220 MM) MAXIMUM ABOVE THE | | | SHOWER FLOOR AND SHALL BE LOCATED ON THE CONTROL WALL | | | 15 INCHES (380 MM) MAXIMUM FROM THE CENTERLINE OF THE | | | SEAT TOWARD THE SHOWER OPENING. | | | | | | 3) 608.7 THRESHOLDS. | | | THRESHOLDS IN ROLL-IN TYPE SHOWER COMPARTMENTS SHALL BE | | | 1/2 INCH (13 MM) HIGH MAXIMUM IN ACCORDANCE WITH 303. | | | IN TRANSFER TYPE SHOWER COMPARTMENTS, THRESHOLDS 1/2 | | | INCH (13 MM) HIGH MAXIMUM SHALL BE BEVELED, ROUNDED, OR | | | VERTICAL. | | | EXCEPTION: A THRESHOLD 2 INCHES (51 MM) HIGH MAXIMUM | | | SHALL BE PERMITTED IN TRANSFER TYPE SHOWER COMPARTMENTS | | | IN EXISTING FACILITIES WHERE PROVISION OF A 1/2 INCH | | | (13 MM) HIGH THRESHOLD WOULD DISTURB THE STRUCTURAL | | | REINFORCEMENT OF THE FLOOR SLAB. | | | | | | 4) 610.3 SHOWER COMPARTMENT SEATS. | | | IN TRANSFER-TYPE SHOWERS, THE SEAT SHALL EXTEND FROM | | | THE BACK WALL TO A POINT WITHIN 3 INCHES (75 MM) OF THE | | | COMPARTMENT ENTRY. THE TOP OF THE SEAT SHALL BE 17 | | | INCHES (430 MM) MINIMUM AND 19 INCHES (485 MM) MAXIMUM | | | ABOVE THE BATHROOM FINISH FLOOR. SEATS SHALL COMPLY | | | WITH 610.3.1 OR 610.3.2. | | | | | | 5) SEE GAS COMMENTS SEPERATE REVIEW AND PERMIT | | | REQUIRED. PLANS CAN BE INCLUDED UNDER THE MASTER SET. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | | REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL | | | LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH | | | A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE | | | SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE | | | FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR | | | YOUR ANTICIPATED COOPERATION. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | DEVELOPMENT SERVICES HOME PAGE | | | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP | | | | | | | | | | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2014-02-10 |
|
|
Cont ID |
|
| Sent By |
llouie |
Date |
2014-02-10 |
Time |
17:24 |
Rev Time |
0.00 |
| Received By |
llouie |
Date |
2014-02-10 |
Time |
17:24 |
Sent To |
|
|
| Notes |
| 2014-02-10 17:27:02 | RENOVATION DOES NOT EXCEED 50 PERCENT OF THE VALUE OF | | | THE STRUCTURE; USE PERMITTED IN GC. | | | | | | | | 2014-02-10 16:11:48 | 2/10/14 |
|
|
|