| 2014-01-23 18:28:15 | BUILDING PLAN REVIEW |
| | PERMIT: 14011385 |
| | ADD: 1793 PALM BEACH LAKES # W409 |
| | CONT: TO BE DETERMINED |
| | TEL: (561)373-3902 |
| | |
| | 2010 FLORIDA BUILDING CODE W |
| | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA |
| | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION |
| | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. |
| | |
| | 2010 EXISTING BUILDING CODE LEVEL II 701.3 |
| | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, |
| | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS |
| | OF THE FLORIDA BUILDING CODE, BUILDING. |
| | |
| | 1ST REVIEW |
| | DATE: THURSDAY JAN. 23/2014 |
| | ACTION: DENIED |
| | |
| | THE PERMIT APPLICATION WILL NEED TO BE UPDATED, UNDER |
| | THE DESCRIPTION OF WORK, ADDING STOCKROOM WALLS. PLEASE |
| | NOTE THIS SPACE IS A SHELL ONLY SPACE, THERE HAS NEVER |
| | BEEN A TENANT TO RECEIVE A CERTIFICATE OF OCCUPANCY. |
| | THIS IS A TENANT BUILD-OUT THAT WILL RECIEVE A |
| | CERTIFICATE OF OCCUPANCY. |
| | |
| | 1) PB OUTLET MALLS: |
| | A LETTER FROM THE QUALIFIER OF BOTH THE SHELL |
| | CONTRACTOR (EMJ CORPORATION) AND TENANT BUILD-OUT |
| | CONTRACTOR MUST BE PROVIDED BEFORE TENANT BUILD-OUT |
| | PERMIT CAN BE ISSUED, IF THE TENANT BUILD-OUT |
| | CONTRACTOR WISHES TO START WORK BEFORE THE SHELL WORK |
| | HAS RECEIVED A CERTIFICATE OF COMPLETION, AGREEING THEY |
| | WILL WORK TOGETHER TO ACHIEVE CODE COMPLIANCE. THESE |
| | DOCUMENTS WILL NEED TO BE SIGNED BY THE QUALIFIER. |
| | |
| | 2) VALUE IS LOW FOR THE AMOUNT OF WORK TO BE COMPLETED |
| | UNDER THE SCOPE OF THIS PERMIT. HOLD WILL BE PUT OM |
| | PERMIT UNTILS FEES ARE INCREASED. |
| | |
| | W P B ADMINISTRTIVE CODE 108.2 SCHEDULE OF PERMIT FEES. |
| | ON BUILDINGS, STRUCTURES, ELECTRICAL, GAS, MECHANICAL, |
| | AND PLUMBING SYSTEMS OR ALTERATIONS REQUIRING A PERMIT, |
| | A FEE FOR EACH PERMIT SHALL BE PAID AS REQUIRED, IN |
| | ACCORDANCE WITH THE SCHEDULE ESTABLISHED BY THE |
| | APPLICABLE GOVERNING AUTHORITY. |
| | |
| | 108.3* BUILDING PERMIT VALUATION. |
| | IF, IN THE OPINION OF THE BUILDING OFFICIAL, THE |
| | CLAIMED VALUATION OF BUILDING, ALTERATION, STRUCTURE, |
| | ELECTRICAL, GAS, MECHANICAL, OR PLUMBING SYSTEMS |
| | APPEARS TO BE UNDER ESTIMATED ON THE APPLICATION, THE |
| | PERMIT SHALL BE DENIED. FOR PERMITTING PURPOSES, |
| | VALUATION OF BUILDINGS AND SYSTEMS SHALL BE TOTAL |
| | REPLACEMENT PURPOSES, VALUATION OF BUILDINGS AND |
| | SYSTEMS SHALL BE THE TOTAL REPLACEMENT VALUE TO INCLUDE |
| | STRUCTURAL, ELECTRICAL, PLUMBING, MECHANICAL, INTERIOR |
| | FINISHES, NORMAL SITE WORK (EXCAVATION AND BACKFILL FOR |
| | BUILDINGS), ARCHITECTURAL AND DESIGN FEES, MARKETING |
| | COST, OVERHEAD AND PROFIT; EXCLUDING ONLY LAND VALUE. |
| | VALUATION REFRENCES MAY INCLUDE THE LATEST PUBLISHED |
| | DATA OF NATIONAL CONSTRUCTION COST ANALYSIS SERVICES |
| | (MARSHALL-SWIFT, MEANS, ETC) WITH REGIONAL ADJUSTMENTS |
| | FOR LOCATION AS PUBLISHED BY THE INTERNATIONAL CODE |
| | CONGRESS. |
| | |
| | 3) PLEASE REVIEW SHEET LS01 EGRESS THRU STOCK ROOM SEE |
| | SECTION: |
| | 2010 FBC-B 1014.2 EGRESS THROUGH INTERVENING SPACES. |
| | EGRESS THROUGH INTERVENING SPACES SHALL COMPLY WITH |
| | THIS SECTION. |
| | 4. EGRESS SHALL NOT PASS THROUGH KITCHENS, STORAGE |
| | ROOMS, CLOSETS OR SPACES USED FOR SIMILAR PURPOSES. |
| | EXCEPTIONS: |
| | 2. MEANS OF EGRESS ARE NOT PROHIBITED THROUGH |
| | STOCKROOMS IN GROUP M OCCUPANCIES WHEN ALL OF THE |
| | FOLLOWING ARE MET: |
| | 2.1. THE STOCK IS OF THE SAME HAZARD CLASSIFICATION AS |
| | THAT FOUND IN THE MAIN RETAIL AREA; |
| | 2.2. NOT MORE THAN 50 PERCENT OF THE EXIT ACCESS IS |
| | THROUGH THE STOCKROOM; |
| | 2.3. THE STOCKROOM IS NOT SUBJECT TO LOCKING FROM THE |
| | EGRESS SIDE; AND |
| | 2.4. THERE IS A DEMARCATED, MINIMUM 44-INCH-WIDE (1118 |
| | MM) AISLE DEFINED BY FULL- OR PARTIAL-HEIGHT FIXED |
| | WALLS OR SIMILAR CONSTRUCTION THAT WILL MAINTAIN THE |
| | REQUIRED WIDTH AND LEAD DIRECTLY FROM THE RETAIL AREA |
| | TO THE EXIT WITHOUT OBSTRUCTIONS. |
| | |
| | 4) PLANS ARE DEFICIENT, EGRESS PATHS CAN NOT BE CHECKED |
| | FOR COMPLIANCE WITH 2010 FBC-B 1017.3 AISLE ACCESSWAYS |
| | IN MERCANTILE OCCUPANCIES. |
| | |
| | 5) PLANS ARE DEFICIENT, EGRESS PATHS CAN NOT BE CHECKED |
| | FOR COMPLIANCE SHOW ACCESSIBLE AISLES 2010 FL |
| | ACCESSIBILITY CODE 403.5.1. |
| | |
| | 6) PLANS DO NOT PROVIDE ENOUGH INFORMATION AS TO IF |
| | EITHER TENANT SPACE WILL REQUIRE DRESSING ROOMS, IF IF |
| | SO THEN COMPLIANCE WITH 2010 FL ACCESSIBILITY CODE |
| | 903.4.1-5. |
| | |
| | 7) PLANS ALSO FAIL TO PROVIDE COMPLIANCE WITH 2010 FL |
| | ACCESSIBILITY CODE 904.3.2 ,904.4.1-2. |
| | |
| | 8) WITH THE OCCUPANT LOAD FOR THIS TENANT, 2 RESTROOMS |
| | ARE REQUIRED, ONE OF THE RESTROOMS CAN BE COUNTED WITH |
| | THE COMMON RESTROOMS IN BUILDING J09, THE SECOND |
| | RESTROOM WILL STILL NEED TO COMPLY WITH 2010 FBC-P |
| | 403.3.1 ACCESS. |
| | THE ROUTE TO THE PUBLIC TOILET FACILITIES REQUIRED BY |
| | SECTION 403.3 SHALL NOT PASS THROUGH KITCHENS, STORAGE |
| | ROOMS OR CLOSETS. ACCESS TO THE REQUIRED FACILITIES |
| | SHALL BE FROM WITHIN THE BUILDING OR FROM THE EXTERIOR |
| | OF THE BUILDING. ALL ROUTES SHALL COMPLY WITH THE |
| | ACCESSIBILITY REQUIREMENTS OF THE FLORIDA BUILDING |
| | CODE, ACCESSIBILITY. THE PUBLIC SHALL HAVE ACCESS TO |
| | THE REQUIRED TOILET FACILITIES AT ALL TIMES THAT THE |
| | BUILDING IS OCCUPIED. |
| | |