Plan Review Details - Permit 14011102
| Plan Review Stops For Permit 14011102 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2014-05-06 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2014-05-06 |
Time |
15:52 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-05-06 |
Time |
06:59 |
Sent To |
|
|
| Notes |
| 2014-05-06 11:27:01 | BUILDING PLAN REVIEW | | | PERMIT: 14011102 | | | ADD: 1715 PALM BEACH LAKES | | | RED ROBIN GOURMET BURGERS & BREWS | | | CONTRACTOR: TO BE DETERMINED | | | CONTACT: A & J | | | TEL: (561) 373-3902 KARI | | | | | | 2010 FLORIDA BUILDING CODE W | | | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | | | RED ROBIN/ WEST PALM BEACH OUTLET MALL | | | 2ND REVIEW | | | DATE: TUES. MAY 06 /2014 | | | ACTION: | | | | | | | | | ROOF PRODUCT APPROVAL SUBMITTED AND REVIEWED UNDERTHIS | | | PERMIT. | | | DURO-LAST NOA 12-0529.09 | | | PAGE 9 OF 15 | | | SINGLE PLY | | | WOOD ,INSULATED | | | -90 PSF LIM # 7. | | | | | | BUILDING APPROVED WITH EXCEPTION! | | | THIS PLAN HAS BEEN APPROVED PROVISIONALLY. FAILURE TO | | | CORRECT THE LISTED DEFICIENCIES IN THIS PLAN PRIOR TO | | | INSPECTION WILL RESULT IN FAILED INSPECTION(S) AND THE | | | ASSESSMENT OF RE-INSPECTION FEE(S). REVISIONS REQUIRE | | | ADDITIONAL REVIEWS WITH ASSOCIATED FEES. | | | | | | 1 ) FL ADMINISTRATIVE CODE. 61G15-31.003 DESIGN OF | | | STRUCTURES UTILIZING PREFABRICATED WOOD TRUSSES. | | | (1) WHEN A STRUCTURAL ENGINEER OF RECORD AND A | | | DELEGATED ENGINEER EXIST AS MAY BE DETERMINED BY | | | APPLICABLE FLORIDA LAW, THE | | | APPORTIONMENT OF RESPONSIBILITIES BETWEEN THE | | | STRUCTURAL ENGINEER OF RECORD AND A DELEGATED ENGINEER | | | SHALL BE AS SET FORTH IN | | | CHAPTER 2 OF ANSI/TPI 1-1995, WHEREIN THE STRUCTURAL | | | ENGINEER OF RECORD IS THE BUILDING DESIGNER AND THE | | | DELEGATED ENGINEER IS | | | THE TRUSS DESIGNER AS THOSE TERMS ARE DEFINED IN SAID | | | STANDARD. | | | | | | (2) THE STRUCTURAL ENGINEER OF RECORD SHALL PROVIDE | | | DESIGN REQUIREMENTS IN WRITING TO THE DELEGATED | | | ENGINEER AND SHALL REVIEW THE | | | DESIGN DOCUMENTS OF THE DELEGATED ENGINEER FOR | | | CONFORMANCE TO HIS WRITTEN INSTRUCTIONS IN ACCORDANCE | | | WITH RULE 61G15-30.005, | | | F.A.C. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2014-04-12 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2014-04-12 |
Time |
18:26 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-04-12 |
Time |
14:30 |
Sent To |
|
|
| Notes |
| 2014-04-12 18:07:19 | BUILDING PLAN REVIEW | | | PERMIT: 14011102 | | | ADD: 1715 PALM BEACH LAKES | | | RED ROBIN GOURMET BURGERS & BREWS | | | CONTRACTOR: TO BE DETERMINED | | | CONTACT: A & J | | | TEL: (561) 373-3902 KARI | | | | | | 2010 FLORIDA BUILDING CODE W | | | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | | | RED ROBIN/ WEST PALM BEACH OUTLET MALL | | | 2ND REVIEW | | | DATE: SAT. APRIL 12/2014 | | | ACTION: DENIED | | | | | | 1-6) COMPLIED> | | | | | | 7) SEMI-COMPLIED. SHEET S8.0 DOES PROVIDE THE WIND | | | DESIGN CRITERIA IN VULT & VASD AS REQUESTEDAND WITH A C | | | EXPOSURE THE WIND DESIGN DOES NOT PROVIDE THE MEAN ROOF | | | HEIGHT AND THE ADJUSTMENT FACTOR FOR THE C EXPOSURE SEE | | | 2010 FBC-B TABLE 1609.7(2). | | | | | | 1ST REVIEW COMMENT.. SHEET S8.0 IDENTIFIES THE BASE | | | CODE 2009 IBC AS THE REFERENCED CODE, PLEASE CORRECT TO | | | THE 2010 FBC-B THE WIND DESIGN CRITERIA IS CORRECT, | | | PLEASE PROVIDE WIND PRESSURES FOR COMPONENTS AND | | | CLADDING AT 10 SQ FT, 20 SQ FT AS WELL AS THE 50 SQ FT | | | IN BOTH VULT AND VASD. FLORIDAS PRODUCT APPROVALS ARE | | | IN VASD. PLEASE NOTE WE USE 10 SQ FT AS THE WORST CASE | | | FOR ROOF FASTENERS. | | | | | | 8) 2ND REQUEST, FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS | | | RULE 9N-3 NOV. 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS | | | OR CONSTRUCTION SYSTEMS THAT WILL REQUIRE PRODUCT | | | APPROVALS: | | | | | | NOTE ONLY ONE SET OF PRODUCT APPROVALS WERE SUBMITTED. | | | | | | (31)(A) EXTERIOR DOORS, ROOF HATCHES. | | | SHEET A2.1 UNDER THE HEADING OF GENERAL NOTES LIST THE | | | EXTERIOR DOORS BY MANUFACTURER AND PRODUCT APPROVAL | | | NUMBER | | | 11-0228.04 KAWNEER 350 IR STOREFRONT DOORS DOOR AND | | | FRAME MAX. 98 1/2 INCHES IN HEIGHT. PLANS THE ENERGY | | | CALCS INDICATE A SHGC OF 0.4 PROVIDE DOCUMENTATION. | | | | | | EXTERIOR DOORS HE HARDWARE SCHEDULE INDICATED THE USE | | | OF A CONTINIOUS HINGE ON DOORS WHERE AS THE PRODUCT | | | APPROVALS DO NOT INDICATE A CONTINIOUS HINGE. | | | | | | SUBMITTED CECO DOORS NOA 09-0505.09 THIS PRODUCT IS NOT | | | LISTED ON SHEET A2.1, THE HOLLOW CORE METAL DOOR THAT | | | IS LISTED IS A NOA 09-0323.23 WHICH IS A DIFFERNT | | | MANUFACTURER, BUT IT IS ALSO A EXPIRED REPORT. | | | | | | REPORTS SUBMITTED BUT LISTED ON SHEET A2.1 ARE AS | | | FOLLOWS: | | | KAWNEER 11-1027.15 350 IR | | | FL 5851-R3 YKK AP | | | | | | NO ROOF HATCH PRODUCT APPROVALS WERE SUBMITTED, IS | | | LOCATED IN A ROOF ZONE 2 WITHIN 10'-0" OF THE EDGE OF | | | THE ROOF. | | | | | | (B) WINDOWS | | | SUBMITTED NOA 11-0915.06 KAWNEER IR-501 SERIES LMI | | | PLEASE NOTE OVERALL HEIGHT LIMITATION OF 120 INCHES | | | WHEREAS A2.1 WINDOW TYPE B SHOWS A OVERALL HEIGHT OF | | | 11'-10". PLEASE PROVIDE ADDITIONAL INFORMATION SHEET 3 | | | OF 9 INDICATES THE TYPE OF FASTENERS TO BE USED IN WOOD | | | OR METAL STUDS. THE DETAIL SHOWS 4 1/2 INCH STRUCTURAL | | | MEMBER THAT IS NOT SHOWN ON ANY A NOR S DRAWINGS, | | | PLEASE PROVIDE WHAT TYPE OF STRUCTURAL SUPPORT THIS IS | | | AND HOW IT WILL BE PART OF THE MWFRS. | | | PLEASE ALSO PROVIDE DOCUMENTATION FOR THE SHGC OF 0.4. | | | | | | (C) EFISWALL SYSTEMS, PLEASE PROVIDE THE MANUFACTURERS | | | INSTALATION BOOKLET. 2010 WEST PALM BEACH AMENDMENTS TO | | | THE FLORIDA BUILDING CODE, CHAPTER 1, ADMINISTRATION, | | | 2010 EDITION 107.2.4 EXTERIOR WALL ENVELOPE. | | | CONSTRUCTION DOCUMENTS FOR ALL BUILDINGS SHALL DESCRIBE | | | THE EXTERIOR WALL ENVELOPE IN SUFFICIENT DETAIL TO | | | DETERMINE COMPLIANCE WITH THIS CODE. THE CONSTRUCTION | | | DOCUMENTS SHALL PROVIDE DETAILS OF THE EXTERIOR WALL | | | ENVELOPE AS REQUIRED, INCLUDING FLASHING, INTERSECTIONS | | | WITH DISSIMILAR MATERIALS, CORNERS, END DETAILS, | | | CONTROL JOINTS, INTERSECTIONS AT ROOF, EAVES OR | | | PARAPETS, MEANS OF DRAINAGE, WATER-RESISTIVE MEMBRANE | | | AND DETAILS AROUND OPENINGS. THE CONSTRUCTION DOCUMENTS | | | SHALL INCLUDE MANUFACTURER?S INSTALLATION INSTRUCTIONS | | | THAT PROVIDE SUPPORTING DOCUMENTATION THAT THE PROPOSED | | | PENETRATION AND OPENING DETAILS DESCRIBED IN THE | | | CONSTRUCTION DOCUMENTS MAINTAIN THE WEATHER RESISTANCE | | | OF THE EXTERIOR WALL ENVELOPE. THE SUPPORTING | | | DOCUMENTATION SHALL FULLY DESCRIBE THE EXTERIOR WALL | | | SYSTEM WHICH WAS TESTED, WHERE APPLICABLE, AS WELL AS | | | THE TEST PROCEDURE USED. | | | | | | (D) ROOFING PRODUCTS AND ASSEMBLIES, ROOFING | | | INSULATION, ROOF CURBING | | | DURO-LAST NOA 12-0529.09 WAS SUBMITTED BUT NO | | | SUB-SYSTEM WAS IDENTIFIED WITH THE ASSOCIATED | | | PRESSURES. MAY REQUIRE ENHANCED FASTENING SEE | | | LIMITATION #7 VERSES #9. 107.2.1.2 FOR ROOF ASSEMBLIES | | | REQUIRED BY THE CODE, THE CONSTRUCTION DOCUMENTS SHALL | | | ILLUSTRATE, DESCRIBE AND DELINEATE THE TYPE OF ROOFING | | | SYSTEM, MATERIALS, FASTENING REQUIREMENTS, FLASHING | | | REQUIREMENTS AND WIND RESISTANCE RATING THAT ARE | | | REQUIRED TO BE INSTALLED. PRODUCT EVALUATION AND | | | INSTALLATION SHALL INDICATE COMPLIANCE WITH THE WIND | | | CRITERIA REQUIRED FOR THE SPECIFIC SITE OR A STATEMENT | | | BY AN ARCHITECT OR ENGINEER FOR THE SPECIFIC SITE MUST | | | BE SUBMITTED WITH THE CONSTRUCTION DOCUMENTS. | | | | | | NO PRODUCT APPROVALS WERE SUBMITTED FOR ROOF TOP CURBS. | | | | | | (G) PRE-ENGINEERED A/C STANDS SHEET A2.3 DOES SHOW ROOF | | | TOP CONDENSING UNITS THAT WILL REQUIRE ROOF TOP STANDS, | | | THESE STANDS WILL ALSO NEED TO CONSIDER THE AMOUNT OF | | | ROOF TOP INSULATION THAT WILL BE REQUIRED BY THE ENERGY | | | CODE SO THEY WILL STILL COMPLY WITH FBC-B TABLE 1509.7 | | | CLEARANCE BENEATH THE STAND TO THE FINISH ROOF TOP. | | | | | | 9) 2010 FBC 107.3.4.1 PRODUCT APPROVALS. THOSE PRODUCTS | | | WHICH ARE REGULATED BY THE DCA RULE 9N-03 SHALL BE | | | REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF | | | RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL. | | | FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR | | | SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS, | | | SHOP DRAWINGS ETC.. | | | | | | 10-11) COMPLIED. | | | | | | 12) 2ND REQUEST SEMI-COMPLIED. 1408.5 INSTALLATION. | | | INSTALLATION OF THE EIFS AND EIFS WITH DRAINAGE SHALL | | | BE IN ACCORDANCE WITH THE EIFS MANUFACTURER?S | | | INSTRUCTIONS. | | | | | | 13) 2ND REQUEST. PLEASE REVIEW THE DRYVIT NOA | | | 11-1108.01 AND THEIR INSTALATION INSTRUCTIONS FOR THE | | | REQUIEMENTS FOR SILL FLASHING DETAILS AND REQUIREMENTS, | | | PLEASE PROVIDE THE TYPE OF MATERIAL AND MINIMUM | | | THICKNESS OF THE SILL FLASHING, AND TYPE OF SEALANTS TO | | | BE USED IN THE INSTALATION. | | | PROVIDE FLASHING DETAILS FOR WINDOWS AND DOORS, 2010 | | | FBC-B 1405.4. FLASHING SHALL BE INSTALLED IN SUCH A | | | MANNER SO AS TO PREVENT MOISTURE FROM ENTERING THE WALL | | | OR TO REDIRECT IT TO THE EXTERIOR. FLASHING SHALL BE | | | INSTALLED AT THE PERIMETERS OF EXTERIOR DOOR AND WINDOW | | | ASSEMBLIES, PENETRATIONS AND TERMINATIONS OF EXTERIOR | | | WALL ASSEMBLIES, EXTERIOR WALL INTERSECTIONS WITH | | | ROOFS, CHIMNEYS, PORCHES, DECKS, BALCONIES AND SIMILAR | | | PROJECTIONS AND AT BUILT-IN GUTTERS AND SIMILAR | | | LOCATIONS WHERE MOISTURE COULD ENTER THE WALL. | | | | | | 14 )2ND REQUEST. THE TRUSS MANUFACTURER ONY DESIGNS THE | | | TRUSS TO TRUSS CONNECTIONS. THE STRUCTURAL ENGINEEER | | | PROVIDES A OVER ALL LAYOUT AND THE LOADS TO BE RESISTED | | | FOR EACH TRUSS. SHEET S2.0 PROVIDES A LAYOUT OF THE | | | TRUSSES AND GIRDERS, THE PLANS DOES NOT SHOW HOW THE | | | UPLIFT LOADS ARE GOING TO BE TRANSFERRED INTO THE WALLS | | | AND MWFRS. PROVIDE LOADS TO BE REISTED, PLEASE ALSO | | | PROVIDE WHAT ADDITIONAL TRUSS HARDWARE BEARING CLIPS | | | ETC FOR THE RED S BUILT TRUSS SYSTEM. | | | | | | FL ADMINISTRATIVE CODE. 61G15-31.003 DESIGN OF | | | STRUCTURES UTILIZING PREFABRICATED WOOD TRUSSES. | | | (1) WHEN A STRUCTURAL ENGINEER OF RECORD AND A | | | DELEGATED ENGINEER EXIST AS MAY BE DETERMINED BY | | | APPLICABLE FLORIDA LAW, THE APPORTIONMENT OF | | | RESPONSIBILITIES BETWEEN THE STRUCTURAL ENGINEER OF | | | RECORD AND A DELEGATED ENGINEER SHALL BE AS SET FORTH | | | IN CHAPTER 2 OF ANSI/TPI 1-1995, WHEREIN THE STRUCTURAL | | | ENGINEER OF RECORD IS THE BUILDING DESIGNER AND THE | | | DELEGATED ENGINEER IS THE TRUSS DESIGNER AS THOSE TERMS | | | ARE DEFINED IN SAID STANDARD. | | | (2) THE STRUCTURAL ENGINEER OF RECORD SHALL PROVIDE | | | DESIGN REQUIREMENTS IN WRITING TO THE DELEGATED | | | ENGINEER AND SHALL REVIEW THE DESIGN DOCUMENTS OF THE | | | DELEGATED ENGINEER FOR CONFORMANCE TO HIS WRITTEN | | | INSTRUCTIONS IN ACCORDANCE WITH RULE 61G15-30.005, | | | F.A.C. | | | | | | | | | 15) COMPLIED. | | | | | | | | | NEW COMMENTS | | | | | | 16) SHEET A1.1 DETAIL # 15 REVISION # 2 USES THE TERM | | | OR IN REGARDS TO SIMPSON A21 OR METAL BRACKETS. 107.2.1 | | | INFORMATION ON CONSTRUCTION DOCUMENTS. SUCH DRAWINGS | | | AND SPECIFICATIONS SHALL CONTAIN INFORMATION, IN THE | | | FORM OF NOTES OR OTHERWISE, AS TO THE QUALITY OF | | | MATERIALS, WHERE QUALITY IS ESSENTIAL TO CONFORMITY | | | WITH THE TECHNICAL CODES. SUCH INFORMATION SHALL BE | | | SPECIFIC, AND THE TECHNICAL CODES SHALL NOT BE CITED AS | | | A WHOLE OR IN PART, NOR SHALL THE TERM "LEGAL" OR ITS | | | EQUIVALENT BE USED AS A SUBSTITUTE FOR SPECIFIC | | | INFORMATION. | | | | | | 17) THE STRUCTURAL SHEETS S1.0, S3.0, S4.0, S5.0 & S8.0 | | | ARE ALL PHOTO-COPIED SIGNATURES NOT ORIGINALS. PLANS, | | | SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS PREPARED BY | | | THE DESIGN PROFESSIONAL AND BEING FILED FOR PUBLIC | | | RECORD SHALL HAVE THE SIGNATURE AND SEAL OF THE DESIGN | | | PROFESSIONAL AFFIXED TO THE DOCUMENT. | | | FL ADMIN CODE 61G15-23.002 ENGINEERS | | | EFFECTIVE DATE 05/06/2009 | | | | | | 18) WHEN RESUBMITTING PLANS PLEASE INDICATE THE | | | REVISION & REMOVE & REPLACE ANY PAGES AS NECESSARY. A | | | TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT | | | NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE THE | | | CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2014-02-22 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2014-02-22 |
Time |
16:48 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-02-22 |
Time |
14:01 |
Sent To |
|
|
| Notes |
| 2014-02-22 16:48:27 | BUILDING PLAN REVIEW | | | PERMIT: 14011102 | | | ADD: 1715 PALM BEACH LAKES | | | RED ROBIN GOURMET BURGERS & BREWS | | | CONTRACTOR: TO BE DETERMINED | | | CONTACT: A & J | | | TEL: (561) 373-3902 KARI | | | | | | 2010 FLORIDA BUILDING CODE W | | | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | | | 2010 EXISTING BUILDING CODE LEVEL II 701.3 | | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | | | 1ST REVIEW | | | DATE: SAT. FEB. 22/2014 | | | ACTION: DENIED | | | | | | 1) THE COVER SHEET CS1.0 INDICATES THIS BUILDING WAS | | | DESIGNED UNDER THE 2007 FBC, PLEASE BE AWARE FLORIDA | | | ADOPTED THE 2010 FLORIDA FAMILY OF CODES STATEWIDE | | | MARCH 15, 2012. PLEASE UPDATE PLANS ACCORDINGLY. | | | | | | 2) PLEASE PROVIDE ORIGINAL SOILS REPORTS 2010 FBC-B | | | 803.2 INVESTIGATIONS REQUIRED. GEOTECHNICAL | | | INVESTIGATIONS SHALL BE CONDUCTED IN ACCORDANCE WITH | | | SECTIONS 1803.3 THROUGH 1803.5. | | | | | | 3) THIS BUILDING IS CLASSIFIED AS A LL-B BUILDING, | | | PLEASE CONTACT THE MANAGER OF RESIDENT INSPECTORS TO | | | SEE IF A RESIDENT INSPECTOR WILL BE REQUIRED FOR THIS | | | BUILDING. 110.3.9 OTHER INSPECTIONS SERVICES. THE | | | BUILDING OFFICIAL MAY MAKE, OR CAUSE TO BE MADE BY | | | OTHERS, THE INSPECTIONS REQUIRED BY SECTION 109. HE/SHE | | | MAY ACCEPT REPORTS OF INSPECTORS OF RECOGNIZED | | | INSPECTION SERVICES, PROVIDED THAT AFTER INVESTIGATION | | | HE/SHE IS SATISFIED AS TO THEIR QUALIFICATIONS AND | | | RELIABILITY. A CERTIFICATE CALLED FOR BY ANY PROVISION | | | OF THE TECHNICAL CODES SHALL NOT BE BASED ON SUCH | | | REPORTS UNLESS THE SAME ARE IN WRITING AND CERTIFIED BY | | | A RESPONSIBLE OFFICER OF SUCH SERVICE. THE BUILDING | | | OFFICIAL MAY REQUIRE THE OWNER TO EMPLOY AN INSPECTION | | | SERVICE IN THE FOLLOWING INSTANCES: 1. FOR BUILDINGS OR | | | ADDITIONS OF TYPE I OR II CONSTRUCTION. | | | MANAGER OF THRESHOLD & RESIDENT INSPECTOR PROGRAM | | | KEN CONRAD | | | TEL 561-805-6666 | | | E-MAIL: [email protected] | | | | | | 4) THIS BUILDING BEING CLASSIFIED AS A BUILDING TYPE | | | LL-B CONSTRUCTION WILL REQUIRE ALL FRAMING, SHEATHING | | | AND OR DECKING TO BE FIRE RETARDANT TREATED WOOD. | | | 2010 FBC-B 603.1 ALLOWABLE MATERIALS. | | | COMBUSTIBLE MATERIALS SHALL BE PERMITTED IN BUILDINGS | | | OF TYPE I OR II CONSTRUCTION IN THE FOLLOWING | | | APPLICATIONS AND IN ACCORDANCE WITH SECTIONS 603.1.1 | | | THROUGH 603.1.3: | | | 1. FIRE-RETARDANT-TREATED WOOD SHALL BE PERMITTED IN: | | | 1.1. NONBEARING PARTITIONS WHERE THE REQUIRED | | | FIRE-RESISTANCE RATING IS 2 HOURS OR LESS. | | | 1.2. NONBEARING EXTERIOR WALLS WHERE NO FIRE RATING IS | | | REQUIRED. | | | 1.3. ROOF CONSTRUCTION, INCLUDING GIRDERS, TRUSSES, | | | FRAMING AND DECKING. | | | | | | 5) 2304.9.5.4 FASTENERS FOR FIRE-RETARDANT-TREATED WOOD | | | USED IN INTERIOR APPLICATIONS. | | | FASTENERS FOR FIRE-RETARDANT-TREATED WOOD USED IN | | | INTERIOR LOCATIONS SHALL BE IN ACCORDANCE WITH THE | | | MANUFACTURER?S RECOMMENDATIONS. IN THE ABSENCE OF | | | MANUFACTURER?S RECOMMENDATIONS, SECTION 2304.9.5.3 | | | SHALL APPLY. | | | | | | 6) SHEET S3.0 PROVIDES DETAILS FOR STEM WALL | | | CONSTRUCTION AND NOTES FOR VAPOR BARRIER BENEATH THE | | | SLAB BUT THERE IS NO MENTION OF HOW TERMITE PROTECTION | | | WILL BE ACHIEVED, SEE 2010 FBC-B 1816.1. | | | | | | 7) SHEET S8.0 IDENTIFIES THE BASE CODE 2009 IBC AS THE | | | REFERENCED CODE, PLEASE CORRECT TO THE 2010 FBC-B THE | | | WIND DESIGN CRITERIA IS CORRECT, PLEASE PROVIDE WIND | | | PRESSURES FOR COMPONENTS AND CLADDING AT 10 SQ FT, 20 | | | SQ FT AS WELL AS THE 50 SQ FT IN BOTH VULT AND VASD. | | | FLORIDAS PRODUCT APPROVALS ARE IN VASD. PLEASE NOTE WE | | | USE 10 SQ FT AS THE WORST CASE FOR ROOF FASTENERS. | | | | | | 8) FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS RULE 9N-3 | | | NOV. 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS OR | | | CONSTRUCTION SYSTEMS THAT WILL REQUIRE PRODUCT | | | APPROVALS: | | | (31)(A) EXTERIOR DOORS, ROOF HATCHES. | | | (B) WINDOWS | | | (C) PANEL WALLS: STOREFRONTS, CURTAIN WALLS, WALL | | | LOUVERS, EFISWALL SYSTEMS, | | | (D) ROOFING PRODUCTS AND ASSEMBLIES, ROOFING | | | INSULATION, ROOF CURBING | | | (E) SHUTTERS | | | (F) SKYLIGHTS | | | (G) EXTERIOR COOLER, FREEZERS & PRE-ENGINEERED A/C | | | STANDS | | | | | | 9) 2010 FBC 107.3.4.1 PRODUCT APPROVALS. THOSE PRODUCTS | | | WHICH ARE REGULATED BY THE DCA RULE 9N-03 SHALL BE | | | REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF | | | RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL. | | | FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR | | | SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS, | | | SHOP DRAWINGS ETC.. | | | | | | 10) SHEET A4.1 INDICATES THE USE OF STONE VENEER ON | | | METAL LATH OVER A WATER RESISTANT BARRIER. PLEASE SHOW | | | COMPLIANCE WITH: | | | FBC-B 1404.2.1 | | | WHERE CEMENT PLASTER (STUCCO) IS TO BE APPLIED TO LATH | | | OVER FRAME CONSTRUCTION, MEASURES SHALL BE TAKEN TO | | | PREVENT BONDING BETWEEN THE CEMENT PLASTER AND THE | | | WATER RESISTIVE BARRIER. A BOND BREAK SHALL BE PROVIDED | | | BETWEEN THE WATER RESISTIVE BARRIER AND THE CEMENT | | | PLASTER (STUCCO) CONSISTING OF ONE OF THE FOLLOWING: | | | 1. TWO LAYERS OF AN APPROVED WATER RESISTANT BARRIER OR | | | 2. ONE LAYER OF AN APPROVED WATER RESISTANT BARRIER | | | OVER AN APPROVED PLASTIC HOUSE WRAP, OR | | | 3. OTHER APPROVED METHODS OR MATERIALS APPLIED IN | | | ACCORDANCE WITH THE MANUFACTURER?S INSTALLATION | | | INSTRUCTIONS. | | | | | | 11) SHEET A4.1 DETAILS 3, 4 & 5 ALL SHOW THE USE OF | | | EFIS AS A EXTERIOR FINISH 1406.2 COMBUSTIBLE EXTERIOR | | | WALL COVERINGS. | | | COMBUSTIBLE EXTERIOR WALL COVERINGS SHALL COMPLY WITH | | | THIS SECTION. EXCEPTION: PLASTICS COMPLYING WITH | | | CHAPTER 26. PROVIDE DOCUMENTATION THAT THE EFIS PRODUCT | | | WILL MEET THIS CODE REQUIREMENT. 2603.4.1.4 EXTERIOR | | | WALLS?ONE-STORY BUILDINGS. | | | FOR ONE-STORY BUILDINGS, FOAM PLASTIC HAVING A FLAME | | | SPREAD INDEX OF 25 OR LESS, AND A SMOKE-DEVELOPED INDEX | | | OF NOT MORE THAN 450, SHALL BE PERMITTED WITHOUT | | | THERMAL BARRIERS IN OR ON EXTERIOR WALLS IN A THICKNESS | | | NOT MORE THAN 4 INCHES (102 MM) WHERE THE FOAM PLASTIC | | | IS COVERED BY A THICKNESS OF NOT LESS THAN | | | 0.032-INCH-THICK (0.81 MM) ALUMINUM OR | | | CORROSION-RESISTANT STEEL HAVING A BASE METAL THICKNESS | | | OF 0.0160 INCH (0.41 MM) AND THE BUILDING IS EQUIPPED | | | THROUGHOUT WITH AN AUTOMATIC SPRINKLER SYSTEM IN | | | ACCORDANCE WITH SECTION 903.3.1.1. | | | | | | 12) PLEASE SHOW COMPLIANCE WITH 2010 FBC-B 1408.3 | | | STRUCTURAL DESIGN. | | | THE UNDERLYING STRUCTURAL FRAMING AND SUBSTRATE SHALL | | | BE DESIGNED AND CONSTRUCTED TO RESIST LOADS AS REQUIRED | | | BY CHAPTER 16. | | | 1408.4 WEATHER RESISTANCE. | | | EIFS SHALL COMPLY WITH SECTION 1403 AND SHALL BE | | | DESIGNED AND CONSTRUCTED TO RESIST WIND AND RAIN IN | | | ACCORDANCE WITH THIS SECTION AND THE MANUFACTURER?S | | | APPLICATION INSTRUCTIONS. | | | 1408.4.1 EIFS WITH DRAINAGE. | | | EIFS WITH DRAINAGE SHALL HAVE AN AVERAGE MINIMUM | | | DRAINAGE EFFICIENCY OF 90 PERCENT WHEN TESTED IN | | | ACCORDANCE THE REQUIREMENTS OF ASTM E 2273 AND IS | | | REQUIRED ON FRAMED WALLS OF TYPE V CONSTRUCTION, GROUP | | | R1, R2, R3 AND R4 OCCUPANCIES. | | | 1408.4.1.1 WATER-RESISTIVE BARRIER. | | | FOR EIFS WITH DRAINAGE, THE WATER-RESISTIVE BARRIER | | | SHALL COMPLY WITH SECTION 1404.2 OR ASTM E 2570. | | | 1408.5 INSTALLATION. | | | INSTALLATION OF THE EIFS AND EIFS WITH DRAINAGE SHALL | | | BE IN ACCORDANCE WITH THE EIFS MANUFACTURER?S | | | INSTRUCTIONS. | | | | | | 13) PROVIDE FLASHING DETAILS FOR WINDOWS AND DOORS, | | | 2010 FBC-B 1405.4. FLASHING SHALL BE INSTALLED IN SUCH | | | A MANNER SO AS TO PREVENT MOISTURE FROM ENTERING THE | | | WALL OR TO REDIRECT IT TO THE EXTERIOR. FLASHING SHALL | | | BE INSTALLED AT THE PERIMETERS OF EXTERIOR DOOR AND | | | WINDOW ASSEMBLIES, PENETRATIONS AND TERMINATIONS OF | | | EXTERIOR WALL ASSEMBLIES, EXTERIOR WALL INTERSECTIONS | | | WITH ROOFS, CHIMNEYS, PORCHES, DECKS, BALCONIES AND | | | SIMILAR PROJECTIONS AND AT BUILT-IN GUTTERS AND SIMILAR | | | LOCATIONS WHERE MOISTURE COULD ENTER THE WALL. | | | | | | 14) SHEET S2.0 PROVIDES A LAYOUT OF THE TRUSSES AND | | | GIRDERS, THE PLANS DOES NOT SHOW HOW THE UPLIFT LOADS | | | ARE GOING TO BE TRANSFERRED INTO THE WALLS AND MWFRS. | | | PROVIDE LOADS TO BE REISTED, PLEASE ALSO PROVIDE WHAT | | | ADDITIONAL TRUSS HARDWARE BEARING CLIPS ETC FOR THE RED | | | S BUILT TRUSS SYSTEM. | | | | | | 15) THIS BUILDING IS BEING DESIGNED AS A TYPE II-B | | | BUILDING WHICH REQUIRES FIRE RETARANT WOOD WITHIN THE | | | FRAMING MEMBERS AS WELL AS TRUSSES. WILL THE RED BUILT | | | TRUSS SYSTEM COME AS A FIRE RETARDANT TREATED MATERIAL | | | OR WOULD THE TREATMENT OCCUR IN THE FIELD? WILL THIS | | | VOID THE WARRENTY. | | | | | | 16) WHEN RESUBMITTING PLANS PLEASE INDICATE THE | | | REVISION & REMOVE & REPLACE ANY PAGES AS NECESSARY. A | | | TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT | | | NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE THE | | | CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | A THOROUGH REVIEW CAN NOT BE MADE AT THIS TIME, AS A | | | RESULT OF THE ADDITIONAL INFORMATION REQUESTED | | | ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF | | | THIS REVIEW. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2014-03-27 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2014-03-27 |
Time |
12:45 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2014-03-27 |
Time |
12:31 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2014-02-18 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2014-02-18 |
Time |
12:13 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2014-02-18 |
Time |
09:23 |
Sent To |
|
|
| Notes |
| 2014-02-18 12:12:50 | 14011102 | | | 1715 PALM BEACH LAKES | | | RED ROBIN GOURMET BURGERS AND BREWS | | | | | | PLEASE REVISE THE PLANS IN RESPONSE TO THE FOLLOWING | | | REVIEW COMMENTS. | | | | | | FEEDERS TO THE MDP ARE UNDERSIZED. THE PLAN INDICATES | | | THE MAIN DISCONNECT IS 1000 AMPERES. NEC 310.16, 240.6, | | | 240.4(C) | | | PANEL LA, AND PANEL M REQUIRE LARGER FEEDERS. NEC 240.4 | | | | | | PROVIDE A LIGHTING DENSITY SUMMARY ON THE PLAN SHOWING | | | COMPLIANCE WITH THE FLORIDA BUILDING ENERGY CODE | | | REQUIREMENTS. FBC ENERGY CONSERVATION 505.3 | | | | | | PROVIDE VOLTAGE DROP CALCULATION VERIFYING COMPLIANCE | | | WITH THE ENERGY CODE. FBC-EC 505.7.3 | | | | | | PROVIDE A SAFETY LABELING SCHEDULE FOR FLASH PROTECTION | | | FOR THE SERVICE, PANEL BOARDS AND MAIN DISCONNECTING | | | MEANS. NEC 110.22, 110.16, 110.22 | | | | | | PROVIDE DIMENSIONS FOR THE DESIGNATED CLEAR WORKING | | | SPACES REQUIRED AROUND THE ELECTRICAL SERVICE EQUIPMENT | | | AND PANEL BOARDS. NEC 215.5, 110.26 | | | | | | WIRING METHODS FOR DATA WHICH ARE LOCATED BELOW GRADE | | | MUST BE LISTED FOR WET LOCATIONS. NEC 110.11 | | | | | | | | | NOTE: SEPARATE PERMITS AND PLANS ARE REQUIRED FOR SITE | | | LIGHTING, ALARM, SECURITY AND DATA SYSTEMS. | | | | | | ROBERT LECKY, CBO | | | ELECTRICAL PLANS REVIEW | | | 561-373-3701 | | | | | | | | | |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
2 |
Status |
P |
Date |
2014-03-31 |
|
|
Cont ID |
|
| Sent By |
mgonzale |
Date |
2014-03-31 |
Time |
|
Rev Time |
1.00 |
| Received By |
mgonzale |
Date |
2014-03-31 |
Time |
|
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
F |
Date |
2014-03-07 |
|
|
Cont ID |
|
| Sent By |
Mgonzale |
Date |
2014-03-07 |
Time |
|
Rev Time |
0.50 |
| Received By |
mgonzale |
Date |
2014-03-07 |
Time |
|
Sent To |
I |
|
| Notes |
| 2014-03-07 08:41:29 | INFO REQUEST - NO OTHER OBJECTIONS. | | | | | | EMAIL PERVIOUS AND IMPREVIOUS TOTALS FOR SITE OUT | | | PARCEL. | | | | | | [email protected] |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2014-03-17 |
|
|
Cont ID |
|
| Sent By |
scaldero |
Date |
2014-03-17 |
Time |
13:18 |
Rev Time |
0.00 |
| Received By |
scaldero |
Date |
2014-03-17 |
Time |
13:18 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2014-01-22 |
|
|
Cont ID |
|
| Sent By |
scaldero |
Date |
2014-01-22 |
Time |
12:19 |
Rev Time |
0.00 |
| Received By |
scaldero |
Date |
2014-01-22 |
Time |
11:45 |
Sent To |
|
|
| Notes |
| 2014-01-22 11:47:11 | PERMIT #14011102 | | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | | | *****FAIL COMMENTS**** | | | UPDATE THE CODE LIST TO REFERENCE THE 2010 EDITION OF | | | THE FLORIDA FIRE PREVENTION CODE WHICH CONTAINS THE | | | 2009 EDITION OF BOTH NFPA 1 AND NFPA 101 WITH FLORIDA | | | AMENDMENTS. | | | | | | PROVIDE DRAWING NOTE INDICATING ALL CONSTRUCTION AND | | | DEMOLITION WORK SHALL CONFORM TO THE REQUIREMENTS OF | | | NFPA 241. TRASH AND CONSTRUCTION DEBRIS SHALL BE | | | REMOVED FROM THE SITE DAILY. SMOKING SHALL BE | | | PROHIBITED EXCEPT IN DESIGNATED EXTERIOR AREAS. ALL | | | OTHER DEMOLITION OR CONSTRUCTION AREAS SHALL HAVE "NO | | | SMOKING" SIGNS POSTED. WHERE SMOKING IS PERMITTED, SAFE | | | RECEPTACLES FOR SMOKING MATERIALS SHALL BE PROVIDED. | | | | | | A THUMB TURN LOCK IS NOT PERMITTED ON THE MAIN ENTRY | | | DOOR(S). IN LIEU OF PANIC HARDWARE, THE MAIN ENTRY IS | | | PERMITTED TO BE EQUIPPED WITH A KEYED LOCK WITH | | | LOCK/UNLOCK INDICATOR WINDOW AND SIGNAGE STATING THE | | | DOOR IS TO REMAIN UNLOCKED DURING BUSINESS HOURS. NO | | | OTHER LOCKING OR LATCHING MECHANISMS ARE PERMITTED. | | | | | | ENGINEERED FIRE ALARM AND FIRE SPRINKLER CONSTRUCTION | | | DOCUMENTS ARE REQUIRED FOR A GENERAL BUILDING PERMIT. | | | AFTER THE BUILDING PERMIT HAS BEEN ISSUED, THE | | | SUBCONTRACTORS CAN THEN SUBMIT SHOP DRAWINGS | | | (CONFORMING TO THE ENGINEERED CONSTRUCTION DOCUMENTS) | | | FOR A SUB-PERMIT. | | | ****************************** | | | EACH FIRE BARRIER SHALL BE PERMANENTLY IDENTIFIED WITH | | | SIGNS OR STENCILING READING FIRE BARRIER-PROTECT ALL | | | OPENINGS. CHARACTERS SHALL BE AT LEAST 4-INCHES IN | | | HEIGHT AND HALF-INCH IN WIDTH. IDENTIFICATION SHALL BE | | | SPACED NOT MORE THAN 15 FEET ON CENTER. | | | | | | AN APPROVED WRITTEN EMERGENCY PLAN FOR THE EMERGENCY | | | EGRESS OF OCCUPANTS IS REQUIRED PRIOR TO OCCUPANCY. ALL | | | EMPLOYEES SHALL BE INSTRUCTED AND PERIODICALLY DRILLED | | | WITH RESPECT TO THEIR DUTIES UNDER THE PLAN. | | | | | | EMPLOYEES SHALL BE PERIODICALLY TRAINED OR INSTRUCTED | | | IN THE USE OF PORTABLE FIRE EXTINGUISHERS. | | | | | | WHERE MUSIC SYSTEMS ARE BEING INSTALLED IN TENANT | | | SPACES: THE SPEAKER SYSTEM WILL NEED TO BE TESTED | | | AGAINST THE FIRE ALARM SYSTEM TO ENSURE THAT THE | | | MINIMUM REQUIRED DECIBEL LEVELS OF THE FIRE ALARM | | | SYSTEM ARE BEING MET. PENDING RESULTS OF FIELD | | | INSPECTION/FIRE ALARM TEST, ADDITIONAL REQUIREMENTS MAY | | | BE NEEDED. | | | | | | PROVIDE PORTABLE FIRE EXTINGUISHERS. EXTINGUISHERS | | | SHALL HAVE A MINIMUM RATING OF 2A:10BC AND SHALL BE | | | TAGGED BY A LICENSED FIRE EXTINGUISHER COMPANY. TRAVEL | | | DISTANCE TO EXTINGUISHERS SHALL NOT EXCEED 75 FEET. | | | | | | EVERY ASSEMBLY OCCUPANCY ROOM NOT HAVING FIXED SEATS | | | SHALL HAVE THE OCCUPANT LOAD OF THE ROOM POSTED IN A | | | CONSPICUOUS PLACE NEAR THE MAIN EXIT FROM THE ROOM. | | | SIGNS SHALL BE DURABLE AND INDICATE THE NUMBER OF | | | OCCUPANTS PERMITTED FOR EACH ROOM. | | | | | | PROVIDE AN EXTERIOR KEY SAFE TO ALLOW EMERGENCY | | | RESPONDERS NON-FORCIBLE ENTRY INTO THE BUILDING DURING | | | NON-BUSINESS HOURS. A KEY SAFE CAN BE ORDERED FROM | | | WWW.KNOXBOX.COM. | | | | | | SUE ELLEN CALDERON | | | FIRE INSPECTOR & INVESTIGATOR | | | OFFICE OF THE FIRE MARSHAL | | | WEST PALM BEACH FIRE RESCUE | | | [email protected] | | | (561) 804-4751 | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2014-05-06 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2014-05-06 |
Time |
15:16 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-05-06 |
Time |
15:16 |
Sent To |
|
|
| Notes |
| 2014-05-06 15:16:48 | GAS REVIEWED UNDER THE MASTER SET OF PLANS, BUT WILL | | | REQUIRE A SEPARATE PERMIT. JW |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
N |
Date |
2014-05-06 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2014-05-06 |
Time |
15:15 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-05-06 |
Time |
15:15 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2014-05-14 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2014-05-14 |
Time |
12:41 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2014-04-25 |
Time |
16:54 |
Sent To |
|
|
| Notes |
| 2014-04-28 11:02:23 | SENT TO C-03 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2014-04-25 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2014-04-25 |
Time |
15:26 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2014-03-12 |
Time |
18:42 |
Sent To |
|
|
| Notes |
| 2014-03-12 18:43:09 | RESUBMITTAL SENT TO C3 SHELF FOR REVIEW. JG. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2014-03-11 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2014-03-07 |
Time |
11:14 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-01-21 |
Time |
13:21 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
P |
Date |
2014-03-24 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2014-03-24 |
Time |
17:16 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-03-24 |
Time |
17:16 |
Sent To |
|
|
| Notes |
| 2014-03-24 17:18:32 | PALM BEACH CTY IMPACT FEE ASSESSMENT | | | MU 2014-6094 | | | 5,974 SQ FT/ RESTAURANT | | | NO FEES | | | |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2014-03-11 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2014-02-22 |
Time |
14:01 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-02-22 |
Time |
14:00 |
Sent To |
|
|
| Notes |
| 2014-02-22 14:01:13 | IMPACT FEES TO BE PAID.BEFORE A PERMIT TO CONSTRUCT, | | | MAY BE ISSUED, IMPACT FEES MUST BE PAID TO PALM BEACH | | | COUNTY. THE ACTUAL PERMIT SET OF PLANS MUST BE STAMPED | | | BY THAT OFFICE, AND A COPY OF THE PAID RECEIPT ATTACHED | | | TO THE PERMIT APPLICATION. PLEASE CALL (561)233-5025 | | | FOR MORE INFORMATION. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2014-04-24 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2014-04-24 |
Time |
11:19 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2014-04-21 |
Time |
15:20 |
Sent To |
|
|
| Notes |
| 2014-04-24 11:18:55 | PLAN PASS PROVISO | | | 1) SEPARATE APPLICATION, PLAN AND PERMIT | | | REQUIRED FOR FIRE SUPPRESSION EXHAUST HOOD | | | AND WALK IN COOLERS. | | | 2) REFER TO SECTION 503.2.4.4 SHUT OFF DAMPER | | | CONTROLS 2010 FLORIDA ENERGY CODE | | | 3) PROVIDE TYPE AND SIZE OF FASTENERS USED | | | TO TIE DOWN CURDS TO ROOF AT FIRST INSPECTION. | | | PER SECTION 301.12 WIND RESISTANCE | | | PLAN REVIEW BY HAROLD MOSER | | | [email protected] | | | OFFICE 561-805-6732 | | | FAX 561-805-6676 | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2014-03-06 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2014-03-06 |
Time |
16:38 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2014-03-06 |
Time |
16:38 |
Sent To |
|
|
| Notes |
| 2014-03-06 16:39:49 | KITCHEN EXHAUST HOOD SYSTEM AND WALK-IN COOLERS | | | EXCLUDED FROM SCOPE OF THIS REVIEW. SEPARATE PLANS, | | | APPLICATION AND PERMIT REQUIRED FOR EACH. | | | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT: | | | RONALD J. REGUEIRO | | | 561.805.6719 | | | [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2014-05-06 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2014-05-06 |
Time |
08:15 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-05-06 |
Time |
06:59 |
Sent To |
|
|
| Notes |
| 2014-05-06 08:15:17 | PLUMBING PROVISO; | | | 1) THE SIZING & INSTALATION OF THE GREASE INTERCEPTOR | | | TO BE UNDER A SEPARATE PERMIT. | | | | | | 2) FUEL GAS REVIEWED, BUT REQUIRES A SEPARATE PERMIT. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | DEVELOPMENT SERVICES HOME PAGE | | | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP | | | | | | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS | | | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS | | | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO | | | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE | | | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. | | | | | | MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF | | | FLORIDA SAVING LIVES AND PROPERTY SINCE 1953 | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2014-04-15 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2014-04-15 |
Time |
16:08 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-04-15 |
Time |
09:55 |
Sent To |
|
|
| Notes |
| 2014-04-15 15:13:52 | PLUMBING PLAN REVIEW | | | PERMIT: 14011102 | | | ADD: 1715 PALM BEACH LAKES | | | RED ROBIN GOURMET BURGERS & BREWS | | | CONTRACTOR: TO BE DETERMINED | | | CONTACT: A & J | | | TEL: (561) 373-3902 KARI | | | | | | 2010 FLORIDA BUILDING CODE W | | | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | | 2012 FBC SUPPLEMENTS ADOPTED | | | APRIL 25/2013. | | | | | | 2ND REVIEW | | | DATE: TUESDAY APRIL 15/2014 | | | ACTION: DENIED | | | | | | 1) NOTICE ONLY: 2010 FBC-PLUMB.315.1 REQUIREMENTS. | | | PUBLIC FOOD SERVICE ESTABLISHMENTS AND FOOD | | | ESTABLISHMENTS, AS DEFINED IN CHAPTER 381 FLORIDA | | | STATUTES, CHAPTER 500 FLORIDA STATUTES AND CHAPTER 509 | | | FLORIDA STATUTES, SHALL COMPLY WITH THE APPLICABLE CODE | | | REQUIREMENTS FOUND IN THE FLORIDA BUILDING CODE, | | | BUILDING, CHAPTER 4, SPECIAL DETAILED REQUIREMENTS | | | BASED ON USE AND OCCUPANCY. PLEASE SEE DBPR WEBSITE FOR | | | ADDITIONAL INFO: | | | HTTP://WWW.MYFLORIDALICENSE.COM/DBPR/HR/LICENSING/ | | | PLANREVIEWINDEX.HTML | | | | | | 2) 2ND REVIEW THE REQUEST FOR REVIEW UNDER 2010 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1, ADMINISTRATION, 2010 EDITION | | | 104.11 ALTERNATE MATERIALS, DESIGN AND METHODS OF | | | CONSTRUCTION IS BEING REVIEWED BY THE BUILDING OFFICIAL | | | AND DIRECT WRITTEN RESPONCE FROM HIM. | | | PLEASE NOTE GREASE INTERCEPTORS REQUIRE A SEPERATE | | | PERMIT FOR RECORD RETENTION AND ENFORCEMENT OF THE | | | CITIES FOG PROGRAM TO KEEP FROM HARMING THE CITIES | | | SANITARY SYSTEM. PLEASE PROVIDE THE SIZE OF THE GREASE | | | INTERCEPTOR, LOCATION AND PROVIDE THE CALCULATION FOR | | | SIZING OF THE GREASE INTERCEPTOR. | | | GREASE INTERCEPTORS THAT ARE SIZED, CONSTRUCTED AND | | | APPROVED IN ACCORDANCE WITH RULE 64E-6, FLORIDA | | | ADMINISTRATIVE CODE AND THAT ARE LOCATED OUTSIDE THE | | | BUILDING SHALL USE THE FORUMULA FOUND IN FBC-P TABLE | | | 1003.5.1 FOR RESTARAUNTS. THIS CAN BE SUBMITTED UNDER | | | THIS REVIEW, NOTED FOR A TURN AROUND PERMIT WHEN | | | APPLIED FOR. | | | | | | 3) 2ND REQUEST. THE GAS REVIEW IS CURRENTLY BEING | | | COMPLETED UNDER THE PLUMBING PLAN REVIEW. IF THIS WAS | | | THE ONLY ISSUE WITH THE PLUMBING PLAN REVIEW IT WOULD | | | BE PULLED OUT AND TO THE SEPERATE FUEL GAS REVIEW. | | | THESE COMMENTS WILL REAPPEAR UNDER THE HEADING OF THE | | | GAS REVIEW. SEPARQATE PERMIT FOR GAS IS REQUIRED | | | BECAUSE OF THE INSPECTION CODES ARE NOT PART OF A | | | PLUMBING PERMIT, | | | | | | 3A) SHEET P3.2 DETAIL 1A A OVERALL GAS RISER DIAGRAM | | | INDICATES THE DESIGN TO BE NATURAL GAS, < THAN A 2 LB | | | SYSTEM (1/2 LB) WITH A TOTAL OVER DISTANCE OF 125 FEET | | | AND A PRESSURE DROP OF 0.3 IN W.C. AND SPECIFIC GRAVITY | | | OF 0.60. | | | | | | 3A)(1) WHEN READING THE LENGTH OF 125 FEET FOR 3 INCH | | | BLACK PIPE THE TABLES INDICATE 2,190 CFH WHERE AS THE | | | PLANS TOTAL LOAD IS 2,257 CFH WHICH IS LOW. | | | | | | 3A)(2) THE SAME DETAIL P3.2 DETAIL 1A SHOWS A 3 INCH | | | BRANCH OFF TO THE RTU UNITS ON THE ROOF. WHERE THIS T | | | OCCURS THE PLANS INDICATE THE SIZE OF THE BLACK STEEL | | | PIPE TO BE REDUCED TO 2 INCH (817 CFH, 125'). PLEASE | | | REVIEW TABLE 402.4(1) FOR 125 FT, IT IS ONLY GOOD FOR | | | 777 CFH ON A 1/2 LB SYSTEM | | | | | | 3A)(3) PLEASE PROVIDE A DETAIL FOR WHERE THE GAS LEAVES | | | THE METER, IT APPEARS TO BE A MANIFOLD WITH A 3 INCH | | | AND A 1 1/4 INCH PIPES LEAVING THE MANIFOLD. PLEASE | | | PROVIDE WHAT SIZE PIPING THE MANIFOLD WILL BE CREATED | | | FROM. ADDITIONAL INFORMATION IS REQUIRED.107.2.1.3. | | | | | | 3A)(4) SHEET P3.2 DETAIL 1A NOTES INCLOSED BY A BOX | | | INDICATE THE PIPE TO BE BLACK STEEL PIPE AND THE TABLE | | | 402.4(1) ALSO CONFIRMS SCHEDULE 40 METALLIC PIPE. | | | SHEET P3.1 DETAIL GAS DETAIL AT COOK LINE INDICATES AS | | | AN ALTERNATE TO WELDED FITTINGS TRACPIPE BY OMEGAFLEX | | | MAY BE USED. TWO ISSUES WITH THIS. | | | A) 2010 FBC-FUEL GAS 404.3 DOES NOT ALLOW FOR FITTINGS | | | OR UNIONS WITH IN WALLS. STEEL PIPE WOULD BE ALLOWED | | | WITH WELDS BUT THE TERM ALTERNATE IS NOT ALLWED. | | | B) 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | | 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | | SUCH DRAWINGS AND SPECIFICATIONS SHALL CONTAIN | | | INFORMATION, IN THE FORM OF NOTES OR OTHERWISE, AS TO | | | THE QUALITY OF MATERIALS, WHERE QUALITY IS ESSENTIAL TO | | | CONFORMITY WITH THE TECHNICAL CODES. SUCH INFORMATION | | | SHALL BE SPECIFIC, AND THE TECHNICAL CODES SHALL NOT BE | | | CITED AS A WHOLE OR IN PART, NOR SHALL THE TERM "LEGAL" | | | OR ITS EQUIVALENT BE USED AS A SUBSTITUTE FOR SPECIFIC | | | INFORMATION. | | | | | | 4) PLEASE PROVIDE COMPLIANCE WITH: 411.1.1 COMMERCIAL | | | COOKING APPLIANCES. | | | COMMERCIAL COOKING APPLIANCES INSTALLED ON CASTERS AND | | | APPLIANCES THAT ARE MOVED FOR CLEANING AND SANITATION | | | PURPOSES SHALL BE CONNECTED TO THE PIPING SYSTEM WITH | | | AN APPLIANCE CONNECTOR LISTED AS COMPLYING WITH ANSI | | | Z21.69 OR IN ACCORDANCE WITH ITEM 1 OR 3 OF SECTION | | | 411.1. | | | | | | 411.1.2 PROTECTION AGAINST DAMAGE. | | | CONNECTORS AND TUBING SHALL BE INSTALLED SO AS TO BE | | | PROTECTED AGAINST PHYSICAL DAMAGE. | | | | | | 411.1.3 CONNECTOR INSTALLATION. | | | APPLIANCE FUEL CONNECTORS SHALL BE INSTALLED IN | | | ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS AND | | | SECTIONS 411.1.3.1 THROUGH 411.1.3.4. | | | | | | 411.1.3.1 MAXIMUM LENGTH. | | | CONNECTORS SHALL HAVE AN OVERALL LENGTH NOT TO EXCEED 6 | | | FEET (1829 MM). MEASUREMENT SHALL BE MADE ALONG THE | | | CENTERLINE OF THE CONNECTOR. ONLY ONE CONNECTOR SHALL | | | BE USED FOR EACH APPLIANCE | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2014-02-24 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2014-02-24 |
Time |
15:53 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-02-22 |
Time |
16:48 |
Sent To |
|
|
| Notes |
| 2014-02-22 16:49:22 | PLUMBING PLAN REVIEW | | | PERMIT: 14011102 | | | ADD: 1715 PALM BEACH LAKES | | | RED ROBIN GOURMET BURGERS & BREWS | | | CONTRACTOR: TO BE DETERMINED | | | CONTACT: A & J | | | TEL: (561) 373-3902 KARI | | | | | | 2010 FLORIDA BUILDING CODE W | | | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | | 2012 FBC SUPPLEMENTS ADOPTED | | | APRIL 25/2013. | | | | | | 1ST REVIEW | | | DATE: SAT. FEB. 22/2014 | | | ACTION: DENIED | | | | | | 1) 2010 FBC-PLUMB.315.1 REQUIREMENTS. PUBLIC FOOD | | | SERVICE ESTABLISHMENTS AND FOOD ESTABLISHMENTS, AS | | | DEFINED IN CHAPTER 381 FLORIDA STATUTES, CHAPTER 500 | | | FLORIDA STATUTES AND CHAPTER 509 FLORIDA STATUTES, | | | SHALL COMPLY WITH THE APPLICABLE CODE REQUIREMENTS | | | FOUND IN THE FLORIDA BUILDING CODE, BUILDING, CHAPTER | | | 4, SPECIAL DETAILED REQUIREMENTS BASED ON USE AND | | | OCCUPANCY. PLEASE SEE DBPR WEBSITE FOR ADDITIONAL INFO: | | | HTTP://WWW.MYFLORIDALICENSE.COM/DBPR/HR/LICENSING/ | | | PLANREVIEWINDEX.HTML | | | | | | 2) PLEASE NOTE GREASE INTERCEPTORS REQUIRE A SEPERATE | | | PERMIT FOR RECORD RETENTION AND ENFORCEMENT OF THE | | | CITIES FOG PROGRAM TO KEEP FROM HARMING THE CITIES | | | SANITARY SYSTEM. PLEASE PROVIDE THE SIZE OF THE GREASE | | | INTERCEPTOR, LOCATION AND PROVIDE THE CALCULATION FOR | | | SIZING OF THE GREASE INTERCEPTOR. | | | GREASE INTERCEPTORS THAT ARE SIZED, CONSTRUCTED AND | | | APPROVED IN ACCORDANCE WITH RULE 64E-6, FLORIDA | | | ADMINISTRATIVE CODE AND THAT ARE LOCATED OUTSIDE THE | | | BUILDING SHALL USE THE FORUMULA FOUND IN FBC-P TABLE | | | 1003.5.1 FOR RESTARAUNTS. THIS CAN BE SUBMITTED UNDER | | | THIS REVIEW, NOTED FOR A TURN AROUND PERMIT WHEN | | | APPLIED FOR. | | | | | | 3) THE SHEET P3.2 DOES HAVE A GAS RISER PLAN BUT NOT | | | ENOUGH INFORMATION IS PROVIDED TO BE ABLE TO COMPLETE A | | | GAS REVIEW AT THIS TIME, A LIST OF REQUIREMENTS IS | | | LISTED BELOW. | | | 3.1. SUBMIT AN ISOMETRIC DRAWING THAT CLEARLY SHOWS ALL | | | CUT SECTIONS OF PIPE AND CORRESPONDING LENGTHS PER | | | FBC-2010 FUEL GAS. | | | | | | 3.2. SHOW TYPE OF PIPING MATERIAL BEING INSTALLED, ALL | | | PIPE SIZES, AND THE EDH NUMBER OF CORRUGATED STAINLESS | | | STEEL TUBING FOR EACH PIPE SIZE IF BEING USED. FUEL GAS | | | 402.3. | | | | | | 3.3. TYPE OF GAS, (LP OR NATURAL). | | | | | | 3.4. BTU LOAD OF EACH APPLIANCE AND THE TOTAL BTU LOAD | | | ON THE SYSTEM. REFER TO THE FBC-2010 FUEL GAS SECS. | | | 401.8 THRU 402.6.1 AND TABLES 402.4(1) THRU 402.4(35) | | | | | | 3.5. SHOW THE DISTANCE FROM THE POINT OF DELIVERY, | | | (METER), TO THE MOST REMOTE OUTLET IN THE BUILDING | | | AND/OR SYSTEM PER THE FBC-2010 FUEL GAS APPENDIX A ? | | | USE OF CAPACITY SECTION A.3.1(4) | | | | | | 3.6. SUBMIT CALCULATIONS FOR COMBUSTION AIR PER THE | | | FBC-2010 FUEL GAS CODE SEC. 304 | | | | | | 3.7 INDICATE THE DELIVERY PRESSURE (PSI) PER FBC-2010 | | | FUEL GAS SEC. 402.2. IF NATURAL GAS SPECIFY .5 PSI OR 2 | | | PSI. | | | | | | 3.8. SUBMIT A DETAIL SHOWING THE TYPE, LOCATION, SIZE | | | AND TERMINATION OF THE GAS VENTS PER FBC-2010 FUEL GAS | | | CODE SEC. 502 THRU 505. | | | | | | 3.9. SUBMIT MANUFACTURE SHEETS FOR ALL GAS EQUIPMENT TO | | | VERIFY COMPLIANCE WITH STANDARDS NFPA 54, NFPA 58, AND | | | FBC-2010 FUEL GAS SEC. 402.2 | | | | | | 4) SHEET A 2.3 THE ROOF PLAN PLEASE SIZE ROOF FOR | | | DRAINAGE, INCLUDE 1/2 THE HEIGTH OF THE PARAPET WALLS, | | | RAINFALL CHART FIGURE 1106.1 INDICATES PALM BEACH | | | COUNTY AS 4.5 INCHES 100 YEAR ONE HOUR RAIN FALL : | | | | | | 4A) SHEET A 2.3 INDICATES THE BACK HALF OF THE ROOF TO | | | BE DRAINED WITH THROUGH THE WALL SCUPPERS AND EMERGENCY | | | OVER FLOW THIS SAME SHEET INDICATES DETAILS 24 & 25 / | | | A4.2 THESE DETAILS CAN NOT BE FOUND. PLEASE SIZE | | | SCUPPERS AND OVERFLOWS TO TABLE FBC-P 1106.7. | | | | | | 4B) THE FRONT HALF OF THE ROOF IS SLOPED TO GUTTER, | | | DETAIL 4 OF A4.2 INDICATES THE GUTTER, BUT THE | | | ANCHORING OF THE GUTTER SYSTEM IS LACKING, NEITHER IS | | | THERE | | | SIZING OF THE GUTTER FOR THE 100 YEARRAIN FOR ONE HOUR | | | AT 4.5 INCHES NOR FOR THE VERTICAL CONDUCTORS OR | | | LEADERS, THE PLAN IS NOT CLEAR IF THEY ARE TO RUN | | | INSIDE OF THE BUILDING OR ON THE EXTERIOR. SEE TABLES | | | 1106.2 FOR VERTICAL & 1106.3 FOR HORIZONTAL PIPING. | | | | | | 4C) 2010 FBC-P 1107.1 REQUIRES A SECONDARY DRAINAGE | | | SYSTEM, WHAT PROVISIONS ARE BEING MADE FOR THE GUTTER | | | SYSTEM, IF THIS IS PLUGGED OR OVER FLOWS THE WATERS | | | WILL TRAVEL DOWN THE LOWER ROOF TO THE SCUPPERS AND | | | OVER FLOW SCUPPERS, PROVIDE ADDITIONAL INFORMATION, ARE | | | TO BE OVERSIZED FOR THIS TYPE OF SITUATION? | | | | | | 4D) PROVIDE HOW THE RAIN WATER RUN OFF WILL BE DRAINED | | | AWAY FROM THE BUILDING, CIVIL SHOWED THE TIE INTO THE | | | STORM DRAIN, WHAT WILL KEEP THE RAINWATER FROM BACKING | | | UP AND ONTO THE ROOF IF THE STORM SYSTEM IS BLOCKED OR | | | FULL? PROVISIONS FOR OVERFLOW? | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | | REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL | | | LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH | | | A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE | | | SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE | | | FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR | | | YOUR ANTICIPATED COOPERATION. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | |
|
|
| Review Stop |
POLICE |
POLICE |
| Rev No |
2 |
Status |
N |
Date |
2014-05-13 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2014-05-13 |
Time |
10:13 |
Rev Time |
0.00 |
| Received By |
eschneid |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2014-05-13 10:16:22 | CRIME PREVENTION THROUGH ENVIRONMENTAL DESIGN | | | THE CITY OF WEST PALM BEACH HAS RECOGNIZED THAT | | | TRADITIONAL CRIME PREVENTION STRATEGIES ARE NOT ENOUGH | | | IN TODAY'S SOCIETY AND A NEW APPROACH IS NEEDED. THE | | | NAME OF THIS APPROACH IS CRIME PREVENTION THROUGH | | | ENVIRONMENTAL DESIGN (CPTED). CPTED ACKNOWLEDGES THE | | | MANNER IN WHICH PHYSICAL SPACE IS DESIGNED OR USED HAS | | | A DIRECT BEARING ON CRIME AND SECURITY. | | | THE PHYSICAL ENVIRONMENT HAS A DRAMATIC EFFECT ON OUR | | | OWN BEHAVIOR AND THE WAY IN WHICH WE VIEW THE BEHAVIOR | | | OF OTHERS. CPTED IS A CONCEPT SUPPORTED BY A SERIES OF | | | OVERLAPPING PRINCIPLES BASED ON THE RELATIONSHIP OF THE | | | BUILT ENVIRONMENT TO THE PRESENCE OR ABSENCE OF | | | UNDESIRABLE BEHAVIOR. THE CPTED CONCEPT IS: "THE PROPER | | | DESIGN AND EFFECTIVE USE OF THE BUILT ENVIRONMENT CAN | | | LEAD TO A REDUCTION IN THE INCIDENCE AND FEAR OF CRIME | | | AND IMPROVEMENT IN THE QUALITY OF LIFE BY INCORPORATING | | | ACCESS CONTROL, NATURAL SURVEILLANCE AND TERRITORIAL | | | DEFENSIVE TACTICS.? | | | CPTED THEORY IS BASED UPON THE CONTENTION THAT | | | PLANNERS, DESIGNERS, ARCHITECTS, LANDSCAPERS AND LAW | | | ENFORCEMENT CAN COOPERATIVELY CREATE A 'SAFE' CLIMATE | | | WITHIN A BUILT ENVIRONMENT" RIGHT FROM THE BEGINNING. | | | SAFETY STRIKES AT THE VERY CORE OF WHAT IS GENERALLY | | | REFERRED TO IN A COMMUNITY AS "QUALITY OF LIFE." A SAFE | | | ENVIRONMENT IS ONE THAT REGULAR USERS PERCEIVE AS SAFE | | | AND NON-USERS (CRIMINALS) PERCEIVE AS HIGHLY RISKY TO | | | FREQUENT AND IN WHICH TO COMMIT CRIMES. | | | THE WEST PALM BEACH POLICE DEPARTMENT HAS OUTLINED | | | GUIDELINES WE WOULD LIKE TO SEE FOLLOWED. IN ADDITION | | | TO THE GUIDELINES, WE ENCOURAGE YOU TO PLEASE ADOPT | | | THESE MINIMUM STANDARDS: | | | | | | RESTAURANT SHALL BE EQUIPPED WITH THE FOLLOWING | | | SECURITY DEVICES AND STANDARDS: | | | (1) A FULLY FUNCTIONING AND OPERATIONAL CCTV SYSTEM | | | CAPABLE OF RECORDING AND RETRIEVING AN IDENTIFIABLE | | | IMAGE TO ASSIST IN OFFENDER IDENTIFICATION AND | | | APPREHENSION. | | | (2) A DROP SAFE OR CASH MANAGEMENT DEVICE FOR | | | RESTRICTED ACCESS TO CASH RECEIPTS. | | | (3) HEIGHT MARKERS AT THE ENTRANCE AND EXITS WHICH | | | DISPLAY HEIGHT MEASURES. | | | (4) A CASH MANAGEMENT POLICY TO LIMIT THE CASH ON HAND | | | AT ALL TIMES. | | | (5) REAR DOORS WILL HAVE A VIEWING WINDOW, DOOR CHIME | | | MOUNTED OUTSIDE AND CCTV COVERAGE | | | (6) WHERE WINDOW(S) ARE PRESENT, A CLEAR AND | | | UNOBSTRUCTED VIEW FROM OUTSIDE THE BUILDING INTO THE | | | BUILDING. | | | (7) RESTAURANT SHALL BE EQUIPPED WITH A SILENT ALARM AT | | | THE HOSTESS STAND, MANAGERS OFFICE, BAR AREA. | | | | | | OFFICER K. TUCKER-CARSILLO | | | CRIME PREVENTION UNIT | | | WEST PALM BEACH POLICE DEPT | | | 600 BANYAN BLVD | | | WEST PALM BEACH, FL 33401 | | | (561) 822-1620 OFFICE | | | (561) 822-1648 FAX | | | [email protected] | | | |
|
|
| Review Stop |
POLICE |
POLICE |
| Rev No |
1 |
Status |
F |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2014-02-25 |
Time |
|
Rev Time |
0.00 |
| Received By |
ktucker |
Date |
2014-02-25 |
Time |
13:49 |
Sent To |
|
|
| Notes |
| 2014-02-25 14:04:35 | 10.1 CONDITIONS FOR APPROVAL | | | PRIOR TO ISSUANCE OF THE FIRST BUILDING PERMIT, THE | | | APPLICANT SHALL PREPARE A CONSTRUCTION SITE SECURITY | | | AND MANAGEMENT PLAN FOR APPROVAL BY THE CITY OF WEST | | | PALM BEACH POLICE DEPARTMENT CPTED OFFICIAL. | | | A. AFTER SITE CLEARING AND PLACEMENT OF CONSTRUCTION | | | TRAILERS, THE DEVELOPER/PROJECT MANAGER SHALL INSTITUTE | | | SECURITY MEASURES TO REDUCE OR ELIMINATE OPPORTUNITIES | | | FOR THEFT. THE MANAGEMENT PLAN SHALL INCLUDE, BUT NOT | | | BE LIMITED TO, TEMPORARY LIGHTING, SECURITY PERSONNEL, | | | VEHICLE BARRIERS, CONSTRUCTION/VISITOR PASS, | | | REDUCE/MINIMIZE ENTRY/EXIT POINTS, ENCOURAGE | | | SUBCONTRACTORS TO SECURE MACHINERY, TOOLS AT END OF | | | WORK DAY, FENCING WITH SCREENING AND OR ANY OTHER | | | MEASURE DEEMED APPROPRIATE TO PROVIDE A SAFE AND SECURE | | | WORKING ENVIRONMENT. | | | B. THE SECURITY MANAGEMENT PLAN SHALL BE MAINTAINED | | | THROUGHOUT THE CONSTRUCTION PHASE OF THE PROJECT. | | | NON-COMPLIANCE WITH THE APPROVED PLAN SHALL RESULT IN A | | | STOP-WORK ORDER FOR THE ENTIRE PLANNED UNIT | | | DEVELOPMENT. | | | C. PROPERTY SHALL BE POST ?NO TRESPASSING? SIGNS EVERY | | | 500 FEET AROUND THE PERIMETER OF THE SITE. | | | | | | RESTAURANT SHALL BE EQUIPPED WITH THE FOLLOWING | | | SECURITY DEVICES AND STANDARDS: | | | (1) A FULLY FUNCTIONING AND OPERATIONAL CCTV SYSTEM | | | CAPABLE OF RECORDING AND RETRIEVING AN IDENTIFIABLE | | | IMAGE TO ASSIST IN OFFENDER IDENTIFICATION AND | | | APPREHENSION. | | | (2) A DROP SAFE OR CASH MANAGEMENT DEVICE FOR | | | RESTRICTED ACCESS TO CASH RECEIPTS. | | | (3) HEIGHT MARKERS AT THE ENTRANCE AND EXITS WHICH | | | DISPLAY HEIGHT MEASURES. | | | (4) A CASH MANAGEMENT POLICY TO LIMIT THE CASH ON HAND | | | AT ALL TIMES. | | | (5) REAR DOORS WILL HAVE A VIEWING WINDOW, DOOR CHIME | | | MOUNTED OUTSIDE AND CCTV COVERAGE | | | (6) WHERE WINDOW(S) ARE PRESENT, A CLEAR AND | | | UNOBSTRUCTED VIEW FROM OUTSIDE THE BUILDING INTO THE | | | BUILDING. | | | (7) RESTAURANT SHALL BE EQUIPPED WITH A SILENT ALARM AT | | | THE HOSTESS STAND, MANAGERS OFFICE, BAR AREA. | | | | | | | | | PLEASE SUBMIT A CCTV PLAN FOR THE INTERIOR AND EXTERIOR | | | OF THE RESTAURANT | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2014-05-13 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2014-05-13 |
Time |
10:12 |
Rev Time |
1.00 |
| Received By |
eschneid |
Date |
2014-05-13 |
Time |
10:12 |
Sent To |
PC |
|
| Notes |
| 2014-05-13 10:12:26 | PASSED W/PROVISO | | | | | | SEPARATE PERMITS ARE REQUIRED FOR THE FOLLOWING: | | | | | | A. PARKING LOT AND STRIPING. | | | B. LANDSCAPE - PLEASE NOTE THAT THE NEW BACKFLOW | | | PREVENTER IS NOT SHOWN IN THE SCOPE OF WORK, BUT IT | | | SHALL BE SCREENED IN ACCORDANCE WITH THE PALM BEACH | | | OUTLETS DESIGN GUIDELINES. | | | C. IRRIGATION | | | D. SIGNAGE | | | E. BICYCLE RACKS | | | | | 2014-04-29 15:03:54 | 4/29/14 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2014-04-02 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2014-04-02 |
Time |
13:53 |
Rev Time |
1.00 |
| Received By |
eschneid |
Date |
2014-04-01 |
Time |
10:59 |
Sent To |
|
|
| Notes |
| 2014-04-01 10:59:09 | FAILED | | | | | | PLEASE PROVIDE WRITTEN RESPONSES TO COMMENTS. | | | | | | 1) THE PALM BEACH OUTLETS MANAGEMENT APPROVAL STAMP WAS | | | NOT PROVIDED ON THE PLANS | | | | | | 2) REPEAT COMMENT: PROVIDE THE DETAILS AND DIMENSIONS | | | FOR THE BICYCLE RACKS AND PAD ON THE PLANS. CONTRARY TO | | | THE RESPONSE LETTER, NO NEW SHEETS WERE PROVIDED | | | SHOWING THE DIMENSIONS ON THE PLANS NOR WAS A RACK | | | DETAIL PROVIDED. THE DIMENSIONS SHALL BE SHOWN ON BOTH | | | THE ARCHITECTURAL SITE AND THE CIVIL SITE PLANS. | | | | | | 3) SEPARATE PERMITS ARE REQUIRED FOR THE FOLLOWING: | | | | | | A. PARKING LOT AND STRIPING. | | | B. LANDSCAPE - PLEASE NOTE THAT THE NEW BACKFLOW | | | PREVENTER IS NOT SHOWN IN THE SCOPE OF WORK, BUT IT | | | SHALL BE SCREENED IN ACCORDANCE WITH THE PALM BEACH | | | OUTLETS DESIGN GUIDELINES. | | | C. IRRIGATION | | | D. SIGNAGE | | | E. SITE SECURITY FENCE | | | F. BICYCLE RACKS | | | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1446. | | | | | | | | | | | 2014-03-20 15:25:40 | 3/20/14 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2014-02-13 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2014-02-13 |
Time |
10:52 |
Rev Time |
1.50 |
| Received By |
eschneid |
Date |
2014-02-13 |
Time |
10:52 |
Sent To |
|
|
| Notes |
| 2014-02-13 12:16:16 | FAILED | | | | | | PLEASE PROVIDE WRITTEN RESPONSES TO COMMENTS. | | | | | | 1) THE CONSTRUCTION SITE SECURITY PLAN SHALL BE UPDATED | | | TO INCLUDE THE RED ROBIN WORK AND BE SUBMITTED AND | | | APPROVE BY THE CITY'S CRIME PREVENTION OFFICER. | | | | | | 2) PROVIDE THE DETAILS AND DIMENSIONS FOR THE BICYCLE | | | RACKS AND PAD ON THE PLANS. | | | | | | 3) THE TRASH AREA RECYCLING ENCLOSURE GATE MAY NOT | | | CONSIST OF CHAIN LINK WITH MESH. IT IS REQUIRED TO BE A | | | SOLID GATE. THIS IS MISLEADING SINCE SOME SHEETS SHOW | | | THIS IN COMPLIANCE (NOTE THAT THE TAG FOR ELEVATION 8 A | | | 1.1 MAY REFERENCE AN INCORRECT VIEW WHICH THIS COMMENT | | | WAS BASED ON.) | | | | | | 4) THE EAST AND WEST ELEVATION LABELS ARE FLIPPED. | | | | | | 5) THE ELEVATIONS DO NOT COMPLY WITH THE PALM BEACH | | | OUTLETS DESIGN GUIDELINES BLANK WALL STANDARDS. THE | | | PRIOR ELEVATIONS SUBMITTED TO THE CITY AS PART OF THE | | | SITE PLAN APPROVAL PROCESS WERE IN COMPLIANCE AND | | | SHOWED THE "NATIVE CUSTOM STONE" BANDING AROUND THE | | | BUILDING WERE THE BRICK AND ANODIZED ALUMINUM DID NOT | | | GO TO THE GROUND. PLEASE SUBMIT THESE ELEVATIONS. | | | | | | 6) THE CURRENT ELEVATIONS CONTAIN LESS GLAZING ALONG | | | THE PALM BEACH LAKES BOULEVARD (EAST) FRONTAGE THAN THE | | | ELEVATIONS SUBMITTED WITH THE SITE PLANS. PLEASE | | | CONSIDER PROVIDING MORE GLAZING. | | | | | | 7) OTHER THEN A REFERENCE ON THE FOUNDATION PLAN, THERE | | | WERE NO SPECIFIC DETAILS PROVIDED FOR THE LOADING AREA | | | WALL. IS IT THE INTENT TO INCLUDE THE WALL WITH THIS | | | PERMIT? IF SO WALL DETAILS ARE REQUIRED. | | | | | | 8) SEPARATE PERMITS ARE REQUIRED FOR THE FOLLOWING: | | | | | | A. PARKING LOT AND STRIPING. | | | B. LANDSCAPE - PLEASE NOTE THAT THE NEW BACKFLOW | | | PREVENTER IS NOT SHOWN IN THE SCOPE OF WORK, BUT IT | | | SHALL BE SCREENED IN ACCORDANCE WITH THE PALM BEACH | | | OUTLETS DESIGN GUIDELINES. | | | C. IRRIGATION | | | D. SIGNAGE | | | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1446. | | | | | | | | 2014-01-27 14:22:05 | 1/27/14 |
|
|
|
Account Summary | Usage Policy | Privacy Policy