2014-01-24 07:15:03 | BUILDING PLAN REVIEW |
| PERMIT: 14010888 |
| ADD: 1801 PALM BEACH LAKES SITE AMENITIES |
| CONT: EMJ |
| TEL: (561) 373-3902 |
| |
| 2010 FLORIDA BUILDING CODE W |
| * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA |
| BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION |
| 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. |
| |
| 1ST REVIEW |
| DATE: FRIDAY JAN. 24/2014 |
| |
| ACTION: BUILDING PROVISO: |
| BUILDING APPROVED WITH EXCEPTION! |
| THIS PLAN HAS BEEN APPROVED PROVISIONALLY. FAILURE TO |
| CORRECT THE LISTED DEFICIENCIES IN THIS PLAN PRIOR TO |
| INSPECTION WILL RESULT IN FAILED INSPECTION(S) AND THE |
| ASSESSMENT OF RE-INSPECTION FEE(S). REVISIONS REQUIRE |
| ADDITIONAL REVIEWS WITH ASSOCIATED FEES. |
| |
| |
| 1) THE PERMIT APPLICATION INDICATES ZERO ( $0.00) |
| DOLLARS FOR A VALUE OF WORK TO BE COMPLETED UNDER THIS |
| PERMIT. THE DOLLAR AMOUNT ON THE BASE BUILDING AND |
| TENANT BUILD-OUT WAS A LOW VALUE WHEN COMBINED. THE |
| BUILDING OFFICIAL HAS REULED THIS IS A SEPERATE PERMIT |
| AND VALUE NOT INCLUDED IN THE MASTER PERMIT WE WILL |
| FIGURE THE COST IF A REASONABLE COST IS NOT SUBMITTED. |
| |
| W P B ADMINISTRTIVE CODE 108.2 SCHEDULE OF PERMIT FEES. |
| ON BUILDINGS, STRUCTURES, ELECTRICAL, GAS, MECHANICAL, |
| AND PLUMBING SYSTEMS OR ALTERATIONS REQUIRING A PERMIT, |
| A FEE FOR EACH PERMIT SHALL BE PAID AS REQUIRED, IN |
| ACCORDANCE WITH THE SCHEDULE ESTABLISHED BY THE |
| APPLICABLE GOVERNING AUTHORITY. |
| |
| 108.3* BUILDING PERMIT VALUATION. |
| IF, IN THE OPINION OF THE BUILDING OFFICIAL, THE |
| CLAIMED VALUATION OF BUILDING, ALTERATION, STRUCTURE, |
| ELECTRICAL, GAS, MECHANICAL, OR PLUMBING SYSTEMS |
| APPEARS TO BE UNDER ESTIMATED ON THE APPLICATION, THE |
| PERMIT SHALL BE DENIED. FOR PERMITTING PURPOSES, |
| VALUATION OF BUILDINGS AND SYSTEMS SHALL BE TOTAL |
| REPLACEMENT PURPOSES, VALUATION OF BUILDINGS AND |
| SYSTEMS SHALL BE THE TOTAL REPLACEMENT VALUE TO INCLUDE |
| STRUCTURAL, ELECTRICAL, PLUMBING, MECHANICAL, INTERIOR |
| FINISHES, NORMAL SITE WORK (EXCAVATION AND BACKFILL FOR |
| BUILDINGS), ARCHITECTURAL AND DESIGN FEES, MARKETING |
| COST, OVERHEAD AND PROFIT; EXCLUDING ONLY LAND VALUE. |
| VALUATION REFRENCES MAY INCLUDE THE LATEST PUBLISHED |
| DATA OF NATIONAL CONSTRUCTION COST ANALYSIS SERVICES |
| (MARSHALL-SWIFT, MEANS, ETC) WITH REGIONAL ADJUSTMENTS |
| FOR LOCATION AS PUBLISHED BY THE INTERNATIONAL CODE |
| CONGRESS. |
| |
| |
| |
| 2) MANUFACTUERERS SPECIFICATION SHEETS DO NOT PROVIDE |
| DOCUMENTATION FOR CODE COMPLIANCE WITH THESE CODE |
| SECTIONS. PLEASE PROVIDE: |
| 2010 FL ACCESSIBILITY CODE. |
| |
| 1A) 220 AUTOMATIC TELLER MACHINES AND FARE MACHINES |
| 220.1 GENERAL. |
| WHERE AUTOMATIC TELLER MACHINES OR SELF-SERVICE FARE |
| VENDING, COLLECTION, OR ADJUSTMENT MACHINES ARE |
| PROVIDED, AT LEAST ONE OF EACH TYPE PROVIDED AT EACH |
| LOCATION SHALL COMPLY WITH 707. WHERE BINS ARE PROVIDED |
| FOR ENVELOPES, WASTE PAPER, OR OTHER PURPOSES, AT LEAST |
| ONE OF EACH TYPE SHALL COMPLY WITH 811. |
| |
| ADVISORY 220.1 GENERAL. |
| IF A BANK PROVIDES BOTH INTERIOR AND EXTERIOR ATMS, |
| EACH SUCH INSTALLATION IS CONSIDERED A SEPARATE |
| LOCATION. ACCESSIBLE ATMS, INCLUDING THOSE WITH SPEECH |
| AND THOSE THAT ARE WITHIN REACH OF PEOPLE WHO USE |
| WHEELCHAIRS, MUST PROVIDE ALL THE FUNCTIONS PROVIDED TO |
| CUSTOMERS AT THAT LOCATION AT ALL TIMES. FOR EXAMPLE, |
| IT IS UNACCEPTABLE FOR THE ACCESSIBLE ATM ONLY TO |
| PROVIDE CASH WITHDRAWALS WHILE INACCESSIBLE ATMS ALSO |
| SELL THEATER TICKETS. 811 STORAGE |
| |
| 811.1 GENERAL. STORAGE SHALL COMPLY WITH 811. |
| 811.2 CLEAR FLOOR OR GROUND SPACE. A CLEAR FLOOR OR |
| GROUND SPACE COMPLYING WITH 305 SHALL BE PROVIDED. |
| |
| 811.3 HEIGHT. STORAGE ELEMENTS SHALL COMPLY WITH AT |
| LEAST ONE OF THE REACH RANGES SPECIFIED IN 308. |
| 811.4 OPERABLE PARTS. OPERABLE PARTS SHALL COMPLY WITH |
| 309. |
| |
| 309 OPERABLE PARTS 309.1 GENERAL.OPERABLE PARTS SHALL |
| COMPLY WITH 309. |
| 309.2 CLEAR FLOOR SPACE. A CLEAR FLOOR OR GROUND SPACE |
| COMPLYING WITH 305 SHALL BE PROVIDED. |
| |
| 309.3 HEIGHT. OPERABLE PARTS SHALL BE PLACED WITHIN ONE |
| OR MORE OF THE REACH RANGES SPECIFIED IN 308. |
| |
| 309.4 OPERATION. OPERABLE PARTS SHALL BE OPERABLE WITH |
| ONE HAND AND SHALL NOT REQUIRE TIGHT GRASPING, |
| PINCHING, OR TWISTING OF THE WRIST. THE FORCE REQUIRED |
| TO ACTIVATE OPERABLE PARTS SHALL BE 5 POUNDS (22.2 N) |
| MAXIMUM. |
| |
| 308.2 FORWARD REACH. 308.2.1 UNOBSTRUCTED. WHERE A |
| FORWARD REACH IS UNOBSTRUCTED, THE HIGH FORWARD REACH |
| SHALL BE 48 INCHES (1220 MM) MAXIMUM AND THE LOW |
| FORWARD REACH SHALL BE 15 INCHES (380 MM) MINIMUM ABOVE |
| THE FINISH FLOOR OR GROUND. |
| |
| FIGURE 308.2.1 UNOBSTRUCTED FORWARD REACH 308.2.2 |
| OBSTRUCTED HIGH REACH. WHERE A HIGH FORWARD REACH IS |
| OVER AN OBSTRUCTION, THE CLEAR FLOOR SPACE SHALL EXTEND |
| BENEATH THE ELEMENT FOR A DISTANCE NOT LESS THAN THE |
| REQUIRED REACH DEPTH OVER THE OBSTRUCTION. THE HIGH |
| FORWARD REACH SHALL BE 48 INCHES (1220 MM) MAXIMUM |
| WHERE THE REACH DEPTH IS 20 INCHES (510 MM) MAXIMUM. |
| WHERE THE REACH DEPTH EXCEEDS 20 INCHES (510 MM), THE |
| HIGH FORWARD REACH SHALL BE 44 INCHES (1120 MM) MAXIMUM |
| AND THE REACH DEPTH SHALL BE 25 INCHES (635 MM) |
| MAXIMUM. |
| |
| FIGURE 308.2.2 OBSTRUCTED HIGH FORWARD REACH 308.3 SIDE |
| REACH. 308.3.1 UNOBSTRUCTED. WHERE A CLEAR FLOOR OR |
| GROUND SPACE ALLOWS A PARALLEL APPROACH TO AN ELEMENT |
| AND THE SIDE REACH IS UNOBSTRUCTED, THE HIGH SIDE REACH |
| SHALL BE 48 INCHES (1220 MM) MAXIMUM AND THE LOW SIDE |
| REACH SHALL BE 15 INCHES (380 MM) MINIMUM ABOVE THE |
| FINISH FLOOR OR GROUND. |
| |
| 707.5 SPEECH OUTPUT. |
| MACHINES SHALL BE SPEECH ENABLED. OPERATING |
| INSTRUCTIONS AND ORIENTATION, VISIBLE TRANSACTION |
| PROMPTS, USER INPUT VERIFICATION, ERROR MESSAGES, AND |
| ALL DISPLAYED INFORMATION FOR FULL USE SHALL BE |
| ACCESSIBLE TO AND INDEPENDENTLY USABLE BY INDIVIDUALS |
| WITH VISION IMPAIRMENTS. SPEECH SHALL BE DELIVERED |
| THROUGH A MECHANISM THAT IS READILY AVAILABLE TO ALL |
| USERS, INCLUDING BUT NOT LIMITED TO, AN INDUSTRY |
| STANDARD CONNECTOR OR A TELEPHONE HANDSET. SPEECH SHALL |
| BE RECORDED OR DIGITIZED HUMAN, OR SYNTHESIZED. |
| EXCEPTIONS: |
| 1. AUDIBLE TONES SHALL BE PERMITTED INSTEAD OF SPEECH |
| FOR VISIBLE OUTPUT THAT IS NOT DISPLAYED FOR SECURITY |
| PURPOSES, INCLUDING BUT NOT LIMITED TO, ASTERISKS |
| REPRESENTING PERSONAL IDENTIFICATION NUMBERS. |
| 2. ADVERTISEMENTS AND OTHER SIMILAR INFORMATION SHALL |
| NOT BE REQUIRED TO BE AUDIBLE UNLESS THEY CONVEY |
| INFORMATION THAT CAN BE USED IN THE TRANSACTION BEING |
| CONDUCTED. |
| 3. WHERE SPEECH SYNTHESIS CANNOT BE SUPPORTED, DYNAMIC |
| ALPHABETIC OUTPUT SHALL NOT BE REQUIRED TO BE AUDIBLE. |
| |
| ADVISORY 707.5 SPEECH OUTPUT. IF AN ATM PROVIDES |
| ADDITIONAL FUNCTIONS SUCH AS DISPENSING COUPONS, |
| SELLING THEATER TICKETS, OR PROVIDING COPIES OF MONTHLY |
| STATEMENTS, ALL SUCH FUNCTIONS MUST BE AVAILABLE TO |
| CUSTOMERS USING SPEECH OUTPUT. TO AVOID CONFUSION AT |
| THE ATM, THE METHOD OF INITIATING THE SPEECH MODE |
| SHOULD BE EASILY DISCOVERABLE AND SHOULD NOT REQUIRE |
| SPECIALIZED TRAINING. FOR EXAMPLE, IF A TELEPHONE |
| HANDSET IS PROVIDED, LIFTING THE HANDSET CAN INITIATE |
| THE SPEECH MODE. |
| |
| 707.5.1 USER CONTROL. SPEECH SHALL BE CAPABLE OF BEING |
| REPEATED OR INTERRUPTED. VOLUME CONTROL SHALL BE |
| PROVIDED FOR THE SPEECH FUNCTION. |
| EXCEPTION: SPEECH OUTPUT FOR ANY SINGLE FUNCTION SHALL |
| BE PERMITTED TO BE AUTOMATICALLY INTERRUPTED WHEN A |
| TRANSACTION IS SELECTED. |
| |
| 707.5.2 RECEIPTS. WHERE RECEIPTS ARE PROVIDED, SPEECH |
| OUTPUT DEVICES SHALL PROVIDE AUDIBLE BALANCE INQUIRY |
| INFORMATION, ERROR MESSAGES, AND ALL OTHER INFORMATION |
| ON THE PRINTED RECEIPT NECESSARY TO COMPLETE OR VERIFY |
| THE TRANSACTION. |
| EXCEPTIONS: |
| |
| 1. MACHINE LOCATION, DATE AND TIME OF TRANSACTION, |
| CUSTOMER ACCOUNT NUMBER, AND THE MACHINE IDENTIFIER |
| SHALL NOT BE REQUIRED TO BE AUDIBLE. |
| |
| 2. INFORMATION ON PRINTED RECEIPTS THAT DUPLICATES |
| INFORMATION AVAILABLE ON-SCREEN SHALL NOT BE REQUIRED |
| TO BE PRESENTED IN THE FORM OF AN AUDIBLE RECEIPT. |
| |
| 3. PRINTED COPIES OF BANK STATEMENTS AND CHECKS SHALL |
| NOT BE REQUIRED TO BE AUDIBLE. |
| |
| 707.6 INPUT. INPUT DEVICES SHALL COMPLY WITH 707.6. |
| 707.6.1 INPUT CONTROLS. AT LEAST ONE TACTILELY |
| DISCERNIBLE INPUT CONTROL SHALL BE PROVIDED FOR EACH |
| FUNCTION. WHERE PROVIDED, KEY SURFACES NOT ON ACTIVE |
| AREAS OF DISPLAY SCREENS, SHALL BE RAISED ABOVE |
| SURROUNDING SURFACES. WHERE MEMBRANE KEYS ARE THE ONLY |
| METHOD OF INPUT, EACH SHALL BE TACTILELY DISCERNABLE |
| FROM SURROUNDING SURFACES AND ADJACENT KEYS. |
| |
| 707.6.2 NUMERIC KEYS. NUMERIC KEYS SHALL BE ARRANGED IN |
| A 12-KEY ASCENDING OR DESCENDING TELEPHONE KEYPAD |
| LAYOUT. THE NUMBER FIVE KEY SHALL BE TACTILELY DISTINCT |
| FROM THE OTHER KEYS. |
| |
| ADVISORY 707.6.2 NUMERIC KEYS. TELEPHONE KEYPADS AND |
| COMPUTER KEYBOARDS DIFFER IN ONE SIGNIFICANT FEATURE, |
| ASCENDING VERSUS DESCENDING NUMERICAL ORDER. BOTH TYPES |
| OF KEYPADS ARE ACCEPTABLE, PROVIDED THE COMPUTER-STYLE |
| KEYPAD IS ORGANIZED SIMILARLY TO THE NUMBER PAD LOCATED |
| AT THE RIGHT ON MOST COMPUTER KEYBOARDS, AND DOES NOT |
| RESEMBLE THE LINE OF NUMBERS LOCATED ABOVE THE COMPUTER |
| KEYS. |
| |
| FIGURE 707.6.2 NUMERIC KEY LAYOUT 707.6.3 FUNCTION |
| KEYS. FUNCTION KEYS SHALL COMPLY WITH 707.6.3. |
| |
| 707.6.3.1 CONTRAST. FUNCTION KEYS SHALL CONTRAST |
| VISUALLY FROM BACKGROUND SURFACES. CHARACTERS AND |
| SYMBOLS ON KEY SURFACES SHALL CONTRAST VISUALLY FROM |
| KEY SURFACES. VISUAL CONTRAST SHALL BE EITHER |
| LIGHT-ON-DARK OR DARK-ON-LIGHT. |
| |
| EXCEPTION: TACTILE SYMBOLS REQUIRED BY 707.6.3.2 SHALL |
| NOT BE REQUIRED TO COMPLY WITH 707.6.3.1. |
| |
| 707.6.3.2 TACTILE SYMBOLS. FUNCTION KEY SURFACES SHALL |
| HAVE TACTILE SYMBOLS AS FOLLOWS: ENTER OR PROCEED KEY: |
| RAISED CIRCLE; CLEAR OR CORRECT KEY: RAISED LEFT ARROW; |
| CANCEL KEY: RAISED LETTER EX; ADD VALUE KEY: RAISED |
| PLUS SIGN; DECREASE VALUE KEY: RAISED MINUS SIGN. |
| |
| 707.7 DISPLAY SCREEN. THE DISPLAY SCREEN SHALL COMPLY |
| WITH 707.7. |
| |
| EXCEPTION: DRIVE-UP ONLY AUTOMATIC TELLER MACHINES AND |
| FARE MACHINES SHALL NOT BE REQUIRED TO COMPLY WITH |
| 707.7.1. |
| |
| 707.7.1 VISIBILITY. THE DISPLAY SCREEN SHALL BE VISIBLE |
| FROM A POINT LOCATED 40 INCHES (1015 MM) ABOVE THE |
| CENTER OF THE CLEAR FLOOR SPACE IN FRONT OF THE |
| MACHINE. |
| |
| 707.7.2 CHARACTERS. CHARACTERS DISPLAYED ON THE SCREEN |
| SHALL BE IN A SANS SERIF FONT. CHARACTERS SHALL BE 3/16 |
| INCH (4.8 MM) HIGH MINIMUM BASED ON THE UPPERCASE |
| LETTER ?I?. CHARACTERS SHALL CONTRAST WITH THEIR |
| BACKGROUND WITH EITHER LIGHT CHARACTERS ON A DARK |
| BACKGROUND OR DARK CHARACTERS ON A LIGHT BACKGROUND. |
| |
| 707.8 BRAILLE INSTRUCTIONS. BRAILLE INSTRUCTIONS FOR |
| INITIATING THE SPEECH MODE SHALL BE PROVIDED. BRAILLE |
| SHALL COMPLY WITH 703.3. |
| |
| JAMES A. WITMER CBO |
| SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| TEL: 561-805-6715 |
| FAX: 561-805-6676 |
| E-MAIL: [email protected] |
| |