Plan Review Details - Permit 14010888
Plan Review Stops For Permit 14010888
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2014-01-24 Cont ID  
Sent By jwitmer Date 2014-01-24 Time 07:15 Rev Time 0.00
Received By jwitmer Date 2014-01-24 Time 06:16 Sent To  
Notes
2014-01-24 07:15:03BUILDING PLAN REVIEW
 PERMIT: 14010888
 ADD: 1801 PALM BEACH LAKES SITE AMENITIES
 CONT: EMJ
 TEL: (561) 373-3902
  
 2010 FLORIDA BUILDING CODE W
 * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION
 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013.
  
 1ST REVIEW
 DATE: FRIDAY JAN. 24/2014
  
 ACTION: BUILDING PROVISO:
 BUILDING APPROVED WITH EXCEPTION!
 THIS PLAN HAS BEEN APPROVED PROVISIONALLY. FAILURE TO
 CORRECT THE LISTED DEFICIENCIES IN THIS PLAN PRIOR TO
 INSPECTION WILL RESULT IN FAILED INSPECTION(S) AND THE
 ASSESSMENT OF RE-INSPECTION FEE(S). REVISIONS REQUIRE
 ADDITIONAL REVIEWS WITH ASSOCIATED FEES.
  
  
 1) THE PERMIT APPLICATION INDICATES ZERO ( $0.00)
 DOLLARS FOR A VALUE OF WORK TO BE COMPLETED UNDER THIS
 PERMIT. THE DOLLAR AMOUNT ON THE BASE BUILDING AND
 TENANT BUILD-OUT WAS A LOW VALUE WHEN COMBINED. THE
 BUILDING OFFICIAL HAS REULED THIS IS A SEPERATE PERMIT
 AND VALUE NOT INCLUDED IN THE MASTER PERMIT WE WILL
 FIGURE THE COST IF A REASONABLE COST IS NOT SUBMITTED.
  
 W P B ADMINISTRTIVE CODE 108.2 SCHEDULE OF PERMIT FEES.
 ON BUILDINGS, STRUCTURES, ELECTRICAL, GAS, MECHANICAL,
 AND PLUMBING SYSTEMS OR ALTERATIONS REQUIRING A PERMIT,
 A FEE FOR EACH PERMIT SHALL BE PAID AS REQUIRED, IN
 ACCORDANCE WITH THE SCHEDULE ESTABLISHED BY THE
 APPLICABLE GOVERNING AUTHORITY.
  
 108.3* BUILDING PERMIT VALUATION.
 IF, IN THE OPINION OF THE BUILDING OFFICIAL, THE
 CLAIMED VALUATION OF BUILDING, ALTERATION, STRUCTURE,
 ELECTRICAL, GAS, MECHANICAL, OR PLUMBING SYSTEMS
 APPEARS TO BE UNDER ESTIMATED ON THE APPLICATION, THE
 PERMIT SHALL BE DENIED. FOR PERMITTING PURPOSES,
 VALUATION OF BUILDINGS AND SYSTEMS SHALL BE TOTAL
 REPLACEMENT PURPOSES, VALUATION OF BUILDINGS AND
 SYSTEMS SHALL BE THE TOTAL REPLACEMENT VALUE TO INCLUDE
 STRUCTURAL, ELECTRICAL, PLUMBING, MECHANICAL, INTERIOR
 FINISHES, NORMAL SITE WORK (EXCAVATION AND BACKFILL FOR
 BUILDINGS), ARCHITECTURAL AND DESIGN FEES, MARKETING
 COST, OVERHEAD AND PROFIT; EXCLUDING ONLY LAND VALUE.
 VALUATION REFRENCES MAY INCLUDE THE LATEST PUBLISHED
 DATA OF NATIONAL CONSTRUCTION COST ANALYSIS SERVICES
 (MARSHALL-SWIFT, MEANS, ETC) WITH REGIONAL ADJUSTMENTS
 FOR LOCATION AS PUBLISHED BY THE INTERNATIONAL CODE
 CONGRESS.
  
  
  
 2) MANUFACTUERERS SPECIFICATION SHEETS DO NOT PROVIDE
 DOCUMENTATION FOR CODE COMPLIANCE WITH THESE CODE
 SECTIONS. PLEASE PROVIDE:
 2010 FL ACCESSIBILITY CODE.
  
 1A) 220 AUTOMATIC TELLER MACHINES AND FARE MACHINES
 220.1 GENERAL.
 WHERE AUTOMATIC TELLER MACHINES OR SELF-SERVICE FARE
 VENDING, COLLECTION, OR ADJUSTMENT MACHINES ARE
 PROVIDED, AT LEAST ONE OF EACH TYPE PROVIDED AT EACH
 LOCATION SHALL COMPLY WITH 707. WHERE BINS ARE PROVIDED
 FOR ENVELOPES, WASTE PAPER, OR OTHER PURPOSES, AT LEAST
 ONE OF EACH TYPE SHALL COMPLY WITH 811.
  
 ADVISORY 220.1 GENERAL.
 IF A BANK PROVIDES BOTH INTERIOR AND EXTERIOR ATMS,
 EACH SUCH INSTALLATION IS CONSIDERED A SEPARATE
 LOCATION. ACCESSIBLE ATMS, INCLUDING THOSE WITH SPEECH
 AND THOSE THAT ARE WITHIN REACH OF PEOPLE WHO USE
 WHEELCHAIRS, MUST PROVIDE ALL THE FUNCTIONS PROVIDED TO
 CUSTOMERS AT THAT LOCATION AT ALL TIMES. FOR EXAMPLE,
 IT IS UNACCEPTABLE FOR THE ACCESSIBLE ATM ONLY TO
 PROVIDE CASH WITHDRAWALS WHILE INACCESSIBLE ATMS ALSO
 SELL THEATER TICKETS. 811 STORAGE
  
 811.1 GENERAL. STORAGE SHALL COMPLY WITH 811.
 811.2 CLEAR FLOOR OR GROUND SPACE. A CLEAR FLOOR OR
 GROUND SPACE COMPLYING WITH 305 SHALL BE PROVIDED.
  
 811.3 HEIGHT. STORAGE ELEMENTS SHALL COMPLY WITH AT
 LEAST ONE OF THE REACH RANGES SPECIFIED IN 308.
 811.4 OPERABLE PARTS. OPERABLE PARTS SHALL COMPLY WITH
 309.
  
 309 OPERABLE PARTS 309.1 GENERAL.OPERABLE PARTS SHALL
 COMPLY WITH 309.
 309.2 CLEAR FLOOR SPACE. A CLEAR FLOOR OR GROUND SPACE
 COMPLYING WITH 305 SHALL BE PROVIDED.
  
 309.3 HEIGHT. OPERABLE PARTS SHALL BE PLACED WITHIN ONE
 OR MORE OF THE REACH RANGES SPECIFIED IN 308.
  
 309.4 OPERATION. OPERABLE PARTS SHALL BE OPERABLE WITH
 ONE HAND AND SHALL NOT REQUIRE TIGHT GRASPING,
 PINCHING, OR TWISTING OF THE WRIST. THE FORCE REQUIRED
 TO ACTIVATE OPERABLE PARTS SHALL BE 5 POUNDS (22.2 N)
 MAXIMUM.
  
 308.2 FORWARD REACH. 308.2.1 UNOBSTRUCTED. WHERE A
 FORWARD REACH IS UNOBSTRUCTED, THE HIGH FORWARD REACH
 SHALL BE 48 INCHES (1220 MM) MAXIMUM AND THE LOW
 FORWARD REACH SHALL BE 15 INCHES (380 MM) MINIMUM ABOVE
 THE FINISH FLOOR OR GROUND.
  
 FIGURE 308.2.1 UNOBSTRUCTED FORWARD REACH 308.2.2
 OBSTRUCTED HIGH REACH. WHERE A HIGH FORWARD REACH IS
 OVER AN OBSTRUCTION, THE CLEAR FLOOR SPACE SHALL EXTEND
 BENEATH THE ELEMENT FOR A DISTANCE NOT LESS THAN THE
 REQUIRED REACH DEPTH OVER THE OBSTRUCTION. THE HIGH
 FORWARD REACH SHALL BE 48 INCHES (1220 MM) MAXIMUM
 WHERE THE REACH DEPTH IS 20 INCHES (510 MM) MAXIMUM.
 WHERE THE REACH DEPTH EXCEEDS 20 INCHES (510 MM), THE
 HIGH FORWARD REACH SHALL BE 44 INCHES (1120 MM) MAXIMUM
 AND THE REACH DEPTH SHALL BE 25 INCHES (635 MM)
 MAXIMUM.
  
 FIGURE 308.2.2 OBSTRUCTED HIGH FORWARD REACH 308.3 SIDE
 REACH. 308.3.1 UNOBSTRUCTED. WHERE A CLEAR FLOOR OR
 GROUND SPACE ALLOWS A PARALLEL APPROACH TO AN ELEMENT
 AND THE SIDE REACH IS UNOBSTRUCTED, THE HIGH SIDE REACH
 SHALL BE 48 INCHES (1220 MM) MAXIMUM AND THE LOW SIDE
 REACH SHALL BE 15 INCHES (380 MM) MINIMUM ABOVE THE
 FINISH FLOOR OR GROUND.
  
 707.5 SPEECH OUTPUT.
 MACHINES SHALL BE SPEECH ENABLED. OPERATING
 INSTRUCTIONS AND ORIENTATION, VISIBLE TRANSACTION
 PROMPTS, USER INPUT VERIFICATION, ERROR MESSAGES, AND
 ALL DISPLAYED INFORMATION FOR FULL USE SHALL BE
 ACCESSIBLE TO AND INDEPENDENTLY USABLE BY INDIVIDUALS
 WITH VISION IMPAIRMENTS. SPEECH SHALL BE DELIVERED
 THROUGH A MECHANISM THAT IS READILY AVAILABLE TO ALL
 USERS, INCLUDING BUT NOT LIMITED TO, AN INDUSTRY
 STANDARD CONNECTOR OR A TELEPHONE HANDSET. SPEECH SHALL
 BE RECORDED OR DIGITIZED HUMAN, OR SYNTHESIZED.
 EXCEPTIONS:
 1. AUDIBLE TONES SHALL BE PERMITTED INSTEAD OF SPEECH
 FOR VISIBLE OUTPUT THAT IS NOT DISPLAYED FOR SECURITY
 PURPOSES, INCLUDING BUT NOT LIMITED TO, ASTERISKS
 REPRESENTING PERSONAL IDENTIFICATION NUMBERS.
 2. ADVERTISEMENTS AND OTHER SIMILAR INFORMATION SHALL
 NOT BE REQUIRED TO BE AUDIBLE UNLESS THEY CONVEY
 INFORMATION THAT CAN BE USED IN THE TRANSACTION BEING
 CONDUCTED.
 3. WHERE SPEECH SYNTHESIS CANNOT BE SUPPORTED, DYNAMIC
 ALPHABETIC OUTPUT SHALL NOT BE REQUIRED TO BE AUDIBLE.
  
 ADVISORY 707.5 SPEECH OUTPUT. IF AN ATM PROVIDES
 ADDITIONAL FUNCTIONS SUCH AS DISPENSING COUPONS,
 SELLING THEATER TICKETS, OR PROVIDING COPIES OF MONTHLY
 STATEMENTS, ALL SUCH FUNCTIONS MUST BE AVAILABLE TO
 CUSTOMERS USING SPEECH OUTPUT. TO AVOID CONFUSION AT
 THE ATM, THE METHOD OF INITIATING THE SPEECH MODE
 SHOULD BE EASILY DISCOVERABLE AND SHOULD NOT REQUIRE
 SPECIALIZED TRAINING. FOR EXAMPLE, IF A TELEPHONE
 HANDSET IS PROVIDED, LIFTING THE HANDSET CAN INITIATE
 THE SPEECH MODE.
  
 707.5.1 USER CONTROL. SPEECH SHALL BE CAPABLE OF BEING
 REPEATED OR INTERRUPTED. VOLUME CONTROL SHALL BE
 PROVIDED FOR THE SPEECH FUNCTION.
 EXCEPTION: SPEECH OUTPUT FOR ANY SINGLE FUNCTION SHALL
 BE PERMITTED TO BE AUTOMATICALLY INTERRUPTED WHEN A
 TRANSACTION IS SELECTED.
  
 707.5.2 RECEIPTS. WHERE RECEIPTS ARE PROVIDED, SPEECH
 OUTPUT DEVICES SHALL PROVIDE AUDIBLE BALANCE INQUIRY
 INFORMATION, ERROR MESSAGES, AND ALL OTHER INFORMATION
 ON THE PRINTED RECEIPT NECESSARY TO COMPLETE OR VERIFY
 THE TRANSACTION.
 EXCEPTIONS:
  
 1. MACHINE LOCATION, DATE AND TIME OF TRANSACTION,
 CUSTOMER ACCOUNT NUMBER, AND THE MACHINE IDENTIFIER
 SHALL NOT BE REQUIRED TO BE AUDIBLE.
  
 2. INFORMATION ON PRINTED RECEIPTS THAT DUPLICATES
 INFORMATION AVAILABLE ON-SCREEN SHALL NOT BE REQUIRED
 TO BE PRESENTED IN THE FORM OF AN AUDIBLE RECEIPT.
  
 3. PRINTED COPIES OF BANK STATEMENTS AND CHECKS SHALL
 NOT BE REQUIRED TO BE AUDIBLE.
  
 707.6 INPUT. INPUT DEVICES SHALL COMPLY WITH 707.6.
 707.6.1 INPUT CONTROLS. AT LEAST ONE TACTILELY
 DISCERNIBLE INPUT CONTROL SHALL BE PROVIDED FOR EACH
 FUNCTION. WHERE PROVIDED, KEY SURFACES NOT ON ACTIVE
 AREAS OF DISPLAY SCREENS, SHALL BE RAISED ABOVE
 SURROUNDING SURFACES. WHERE MEMBRANE KEYS ARE THE ONLY
 METHOD OF INPUT, EACH SHALL BE TACTILELY DISCERNABLE
 FROM SURROUNDING SURFACES AND ADJACENT KEYS.
  
 707.6.2 NUMERIC KEYS. NUMERIC KEYS SHALL BE ARRANGED IN
 A 12-KEY ASCENDING OR DESCENDING TELEPHONE KEYPAD
 LAYOUT. THE NUMBER FIVE KEY SHALL BE TACTILELY DISTINCT
 FROM THE OTHER KEYS.
  
 ADVISORY 707.6.2 NUMERIC KEYS. TELEPHONE KEYPADS AND
 COMPUTER KEYBOARDS DIFFER IN ONE SIGNIFICANT FEATURE,
 ASCENDING VERSUS DESCENDING NUMERICAL ORDER. BOTH TYPES
 OF KEYPADS ARE ACCEPTABLE, PROVIDED THE COMPUTER-STYLE
 KEYPAD IS ORGANIZED SIMILARLY TO THE NUMBER PAD LOCATED
 AT THE RIGHT ON MOST COMPUTER KEYBOARDS, AND DOES NOT
 RESEMBLE THE LINE OF NUMBERS LOCATED ABOVE THE COMPUTER
 KEYS.
  
 FIGURE 707.6.2 NUMERIC KEY LAYOUT 707.6.3 FUNCTION
 KEYS. FUNCTION KEYS SHALL COMPLY WITH 707.6.3.
  
 707.6.3.1 CONTRAST. FUNCTION KEYS SHALL CONTRAST
 VISUALLY FROM BACKGROUND SURFACES. CHARACTERS AND
 SYMBOLS ON KEY SURFACES SHALL CONTRAST VISUALLY FROM
 KEY SURFACES. VISUAL CONTRAST SHALL BE EITHER
 LIGHT-ON-DARK OR DARK-ON-LIGHT.
  
 EXCEPTION: TACTILE SYMBOLS REQUIRED BY 707.6.3.2 SHALL
 NOT BE REQUIRED TO COMPLY WITH 707.6.3.1.
  
 707.6.3.2 TACTILE SYMBOLS. FUNCTION KEY SURFACES SHALL
 HAVE TACTILE SYMBOLS AS FOLLOWS: ENTER OR PROCEED KEY:
 RAISED CIRCLE; CLEAR OR CORRECT KEY: RAISED LEFT ARROW;
 CANCEL KEY: RAISED LETTER EX; ADD VALUE KEY: RAISED
 PLUS SIGN; DECREASE VALUE KEY: RAISED MINUS SIGN.
  
 707.7 DISPLAY SCREEN. THE DISPLAY SCREEN SHALL COMPLY
 WITH 707.7.
  
 EXCEPTION: DRIVE-UP ONLY AUTOMATIC TELLER MACHINES AND
 FARE MACHINES SHALL NOT BE REQUIRED TO COMPLY WITH
 707.7.1.
  
 707.7.1 VISIBILITY. THE DISPLAY SCREEN SHALL BE VISIBLE
 FROM A POINT LOCATED 40 INCHES (1015 MM) ABOVE THE
 CENTER OF THE CLEAR FLOOR SPACE IN FRONT OF THE
 MACHINE.
  
 707.7.2 CHARACTERS. CHARACTERS DISPLAYED ON THE SCREEN
 SHALL BE IN A SANS SERIF FONT. CHARACTERS SHALL BE 3/16
 INCH (4.8 MM) HIGH MINIMUM BASED ON THE UPPERCASE
 LETTER ?I?. CHARACTERS SHALL CONTRAST WITH THEIR
 BACKGROUND WITH EITHER LIGHT CHARACTERS ON A DARK
 BACKGROUND OR DARK CHARACTERS ON A LIGHT BACKGROUND.
  
 707.8 BRAILLE INSTRUCTIONS. BRAILLE INSTRUCTIONS FOR
 INITIATING THE SPEECH MODE SHALL BE PROVIDED. BRAILLE
 SHALL COMPLY WITH 703.3.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2014-02-06 Cont ID  
Sent By jwitmer Date 2014-02-06 Time 09:24 Rev Time 0.00
Received By jwitmer Date 2014-02-03 Time 16:03 Sent To  
Notes
2014-02-03 16:03:20TO ZONING
  

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2014-02-03 Cont ID  
Sent By shill Date 2014-01-30 Time 12:33 Rev Time 0.00
Received By shill Date 2014-01-17 Time 06:45 Sent To  
Notes
2014-01-31 07:40:481/31 ON SH DESK
  
2014-01-18 06:45:48SENT TO ZONING

Review Stop POLICE POLICE
Rev No 2 Status P Date   Cont ID  
Sent By   Date 2014-02-04 Time   Rev Time 0.00
Received By ktucker Date 2014-02-04 Time 14:29 Sent To  
Notes
2014-02-04 14:29:55CONTRACTOR WILL REMOVE ATM'S AND WILL RE SUBMIT.

Review Stop POLICE POLICE
Rev No 1 Status F Date 2014-01-31 Cont ID  
Sent By   Date 2014-01-31 Time   Rev Time 0.00
Received By ktucker Date 2014-01-31 Time 08:32 Sent To  
Notes
2014-01-31 08:33:23AUTOMATED TELLER MACHINES
  
  ATM LOCATIONS SHALL BE IN AREAS WITH THE GREATEST
 NATURAL SURVEILLANCE AND INDEPENDENT FROM THE
 BUILDING.
 A. AUTOMATED TELLER MACHINES (ATM?S) SHALL COMPLY WITH
 FSS 655-966.
 B. ATM?S SHALL BE LOCATED ON MAIN ROADS IF APPLICABLE
 AND BE VISIBLE FROM THE ROADWAY.
 C. ATM?S SHALL NOT BE HIDDEN BY ANY LANDSCAPING OR
 OTHER FIXED OBJECT THAT WOULD PREVENT CLEAR VISIBILITY.
 D. ATM?S SHALL HAVE HIGH-RESOLUTION COLOR DIGITAL VIDEO
 CAMERA SYSTEM INSTALLED.
 E. ATM?S SHALL HAVE HIGH ILLUMINATION OF WALKWAYS
 LEADING TO AND FROM IT.
 F. LIGHTING SHALL BE POSITIONED SO AS NOT TO CAUSE
 GLARE ON VIDEO RECORDING.
 G. CONVEX MIRROR SHALL BE INSTALLED AND STRATEGICALLY
 PLACED TO ALLOW ATM OPERATOR TO IDENTIFY ANY
 APPROACHING PERSON(S) AND/OR POTENTIAL SUSPECT(S).
 H. ATM?S SHALL HAVE AN ALARM SYSTEM COMPONENTS, SHOCK
 AND SEISMIC SENSORS, SUFFICIENT WEIGHT AND TENSILE
 STRENGTH, HEAT DETECTORS, DOOR CONTACTS AND LOCKING
 MECHANISMS, TO DETER ATTACKS TO THE MACHINE ITSELF.
 DEVICES ARE NEEDED TO PROVIDE EARLY WARNING OF AN
 IMPENDING ATTACK.
 I. ATM?S SHOULD HAVE DURESS ALARMS AND A SECURE CLOSET
 TO SERVICE THE MACHINE.
  
 PLEASE NOT THE FSS ABOVE AND PROVIDE THE NEEDED
 INFORMATION. IN ADDITION: PLEASE SHOW THE LOCATIONS OF
 THE SECURITY CAMERAS THAT WILL BE COVERING THESE
 MACHINES FROM THE MALL SECURITY PLAN. I AGREE WITH
 PLANNER E. SCHNEIDER, I WILL WAIT FOR THE FOLLOW UP.
  
  
  

Review Stop Z ZONING
Rev No 2 Status P Date 2014-02-05 Cont ID  
Sent By eschneid Date 2014-02-05 Time 20:20 Rev Time 0.25
Received By eschneid Date 2014-02-05 Time 20:20 Sent To PC
Notes
2014-02-05 20:20:44ATMS AND PEDESTRIAN SIGNS ON SEPARATE PERMITS.
2014-02-04 14:33:232/4/14 - ZONING RECEIVED. SENT TO ES FOR REVIEW. LL

Review Stop Z ZONING
Rev No 1 Status F Date 2014-01-30 Cont ID  
Sent By eschneid Date 2014-01-30 Time 13:15 Rev Time 2.00
Received By eschneid Date 2014-01-21 Time 08:27 Sent To B
Notes
2014-01-30 14:43:48FAILED
  
 PLEASE PROVIDE WRITTEN RESPONSE.
  
 1) THE SITE PLAN SHOWS 4 ATM LOCATIONS (FOOD COURT AND
 IN EACH OF THE N/S CORRIDORS). THE SPEC SHEETS SHOW 2
 DIFFERENT ATM MACHINES. A CENTURY BANK "BOX" AND A
 CHASE BANK TOWER/ATM. PLEASE INDICATE WHICH TYPE OF ATM
 GOES IN EACH LOCATION.
  
 2) THE SITE PLAN SHOWS THE ATMS AS APPROXIMATELY 2 FEET
 WIDE BY 2 FEET DEEP.
  
 A. THE CENTURY BANK ATM IS SHOWN ON THE CUT SHEETS AS
 4.6 FEET WIDE BY 7.2 FEET DEEP. THIS SEEMS INCREDIBLY
 LARGE FOR ATM MACHINES THAT WILL BE FREESTANDING IN
 AREAS OF HIGH FOOT TRAFFIC. IN FACT THE DEPTH OF THIS
 ATM EXCEEDS THE DEPTH OF THE RMUS. ADDITIONALLY, THE
 DRAWINGS SHALL NOT CITE THE CAMBRIDGE GALLERIA.
  
 B. THE CHASE BANK ATM IS SHOWN ON THE CUT SHEET AS A
 2.67 FEET WIDE BY 2.33 FEET DEEP FOR THE TOWER CABINET
 AND ATM COMBINED. HOWEVER THE CUT SHEET SHOWS AN
 ADDITIONAL WALL RECESS SURROUNDING THE TOWER/ATM.
 PLEASE EXPLAIN THIS CONDITION SINCE THE SITE PLAN SHOWS
 NO WALLED STRUCTURE CONSTRUCTED TO HOLD THE ATM.
  
 3) HOW ARE THE ATM MACHINES SECURED INTO PLACE?
  
 4) THE PEDESTRIAN DIRECTORY SIGNS REQUIRE PERMITTING AS
 SIGNS AND MAY NOT BE INCLUDED WITH THE SITE AMENITIES
 PERMIT. PLEASE NOTE THAT THE SIGN CUT SHEET INCLUDED
 WITH THE APPLICATION SHOWS A SIGN LARGER THAN WHAT IS
 PERMITTED BY THE SIGN REGULATIONS FOR THE PALM BEACH
 OUTLETS.
  
 5) THE BICYCLE RACKS ARE NOT PART OF THIS PERMIT, BUT
 RATHER PERMIT NO. 14010643.
  
 6) BILL DUFFY PROVIDED A VALUE OF THE FURNITURE AND
 POTS AT $143,000. PLEASE PROVIDE A VALUE OF THE ATMS
 AND THE SMART CARTS. PLEASE NOTE THAT SINCE THE
 MAJORITY OF THE COMMENTS FOR ZONING, THE POLICE
 COMMENTS AND THE BUILDING PROVISO ARE FOR THE ATM, IT
 MAY BE BENEFICIAL TO REMOVE THE ATMS FROM THIS PERMIT
 SO THE REMAINDER OF THE PERMIT ITEMS CAN HAVE A PERMIT
 ISSUED.
  
 PLEASE CONTACT ERIC SCHNEIDER AT (561) 822-1446.
  
  
2014-01-21 08:27:291/21/14 - ZONING RECEIVED. SENT TO ES FOR REVIEW. LL


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved