| Plan Review Stops For Permit 14010716 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2014-03-03 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2014-03-03 |
Time |
17:24 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2014-03-03 |
Time |
17:24 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2014-02-06 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2014-02-06 |
Time |
09:08 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2014-02-06 |
Time |
09:08 |
Sent To |
|
|
| Notes |
| 2014-02-06 09:08:37 | RESIDENTIAL (R3) ALTERATION/RENOVATION BUILDING REVIEW | | | COMMENTS. | | | CODE: 2010 FBC | | | | | | 1- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY | | | DCA RULE 9N-3 FOR ROOF SHINGLES. NOA 11-0223.11 | | | SUBMITTED WAS SUPERSEDED BY MIAMI-DADE. NEED TO PROVIDE | | | CURRENT NOA. VISIT THE MIAMI-DADE WEBSITE AND DOWNLOAD | | | CURRENT NOA. | | | | | | 2- CLEARLY SPECIFY EXISTING BEDROOM WINDOW TYPE AND | | | SIZE AND PROPOSED WINDOW TYPE AND SIZE TO VERIFY | | | COMPLIANCE WITH THE EGRESS REQUIREMENTS OF SEC. R310 OF | | | 2010 FBC-RESIDENTIAL. | | | | | | 3- PROVIDE ENERGY CALCULATIONS. SEC. 101.4.3 OF 2010 | | | FBC-ENERGY CONSERVATION. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561)805-6712 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2014-02-27 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2014-03-03 |
Time |
17:52 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2014-02-27 |
Time |
11:49 |
Sent To |
B |
|
| Notes |
| 2014-02-27 12:09:55 | ISSUED WITH PROVISO: | | | ALL NEW GENERAL PURPOSE OUTLETS MUST BE AFCI PROTECTED. | | | NEC 210.12 | | | NEW RECEPTACLES MUST BE TAMPER RESISTANT. NEC 406.11 | | | REMODELING OF AN EXISTING STRUCTURE IS REQUIRED TO | | | INCLUDE INTERCONNECTED SMOKE DETECTORS. IF THE | | | RESIDENCE HAS GAS APPLIANCES, AN ATTACHED GARAGE OR A | | | FIRE PLACE A CARBON MONOXIDE DETECTOR IS REQUIRED | | | WITHIN TEN FEET OF EACH ROOM USED FOR SLEEPING. FBC | | | R313 | | | KITCHEN COUNTER TOP RECEPTACLES TO BE GFCI PROTECTED. | | | NEC 210.8 | | | GFCI PROTECTED RECEPTACLES ARE REQUIRED AT FRONT AND | | | REAR ELEVATIONS. NEC 210.8 | | | PROVIDE TWO OR MORE 20- AMPERE SMALL APPLIANCE BRANCH | | | CIRCUITS. NEC 210.52 | | | PROVIDE A 20 AMPERE BRANCH CIRCUIT FOR THE BATHROOMS. | | | NEC 210.11 (C)(3) | | | THE LIVING AREA REQUIRES A SWITCHED RECEPTACLE OR LIGHT | | | AND SWITCH CONTROLLED OUTSIDE LIGHTS. NEC 210.70 | | | | | | | | | RL |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2014-02-18 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2014-02-18 |
Time |
12:42 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2014-02-18 |
Time |
12:42 |
Sent To |
|
|
| Notes |
| 2014-02-18 12:43:34 | 14010716 | | | 3816 SHELLY RD. S. | | | SFD REMODEL | | | | | | PLEASE REVISE THE PLANS IN RESPONSE TO THE FOLLOWING | | | ELECTRICAL REVIEW COMMENTS. | | | | | | THE SCOPE OF THE PROPOSED ELECTRICAL WORK IS NOT CLEAR. | | | PROVIDE A DETAILED ELECTRICAL PLAN FOR ALL | | | IMPROVEMENTS. | | | | | | INDICATE THE SIZE, RATING, LOCATION OF THE ELECTRIC | | | SERVICE, MAIN DISCONNECT AND PANEL BOARD. SHOW SERVICE | | | AND PANEL BOARD LOCATIONS. SHOW NEW AND EXISTING | | | OUTLETS. INCLUDE A PANEL SCHEDULE WITH SUMMARY LOAD | | | CALCULATION. NEC 215.5 | | | | | | ALL NEW GENERAL PURPOSE OUTLETS MUST BE AFCI PROTECTED. | | | NEC 210.12 | | | | | | NEW RECEPTACLES MUST BE TAMPER RESISTANT. NEC 406.11 | | | | | | REMODELING OF AN EXISTING STRUCTURE IS REQUIRED TO | | | INCLUDE INTERCONNECTED SMOKE DETECTORS. IF THE | | | RESIDENCE HAS GAS APPLIANCES, AN ATTACHED GARAGE OR A | | | FIRE PLACE A CARBON MONOXIDE DETECTOR IS REQUIRED | | | WITHIN TEN FEET OF EACH ROOM USED FOR SLEEPING. FBC | | | R313 | | | | | | SHOW THE KITCHEN COUNTER TOP RECEPTACLES TO BE GFCI | | | PROTECTED. NEC 210.8 | | | | | | GFCI PROTECTED RECEPTACLES ARE REQUIRED AT FRONT AND | | | REAR ELEVATIONS. NEC 210.8 | | | | | | PROVIDE TWO OR MORE 20- AMPERE SMALL APPLIANCE BRANCH | | | CIRCUITS. NEC 210.52 | | | | | | PROVIDE A 20 AMPERE BRANCH CIRCUIT FOR THE BATHROOMS. | | | NEC 210.11 (C)(3) | | | | | | THE LIVING AREA REQUIRES A SWITCHED RECEPTACLE OR LIGHT | | | AND SWITCH CONTROLLED OUTSIDE LIGHTS. NEC 210.70 | | | | | | ADD RECEPTACLES SO THAT NO WALL SPACE IS MORE THAN 6 | | | FEET FROM A RECEPTACLE AND ALL WALL SPACES MORE THAN 2 | | | FEET IN WIDTH HAVE A RECEPTACLE. NEC 210.52 | | | | | | A BONDING STRIP IS REQUIRED AT THE ELECTRIC SERVICE | | | GROUND NEC 250.94 | | | | | | | | | ROBERT LECKY | | | ELECTRICAL PLANS EXAMINER | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2014-03-03 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2014-02-27 |
Time |
11:09 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2014-02-27 |
Time |
11:09 |
Sent To |
E |
|
| Notes |
| 2014-02-27 11:10:07 | GIVEN TO RLECKY. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2014-02-18 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2014-02-18 |
Time |
12:43 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2014-01-14 |
Time |
08:33 |
Sent To |
|
|
| Notes |
| 2014-01-15 08:33:37 | SENT TO R1 SHELF FOR REVIEW. JG. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2014-03-03 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2014-03-03 |
Time |
17:44 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2014-03-03 |
Time |
17:44 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2014-02-06 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2014-02-06 |
Time |
15:50 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2014-02-06 |
Time |
15:50 |
Sent To |
|
|
| Notes |
| 2014-02-06 16:01:25 | RESIDENTIAL (R3) ALTERATION/RENOVATION, MECHANICAL | | | REVIEW COMMENTS. | | | CODE: 2010 FBC. | | | | | | 1- A/C CONTRACTOR TO PROVIDE COMPLETE INFORMATION FOR | | | EXACT CHANGE OUT EQUIPMENT. SEE CITY SAMPLES FOR OPTION | | | 1 OR OPTION 2 COMPLIANCE. SEC. 101.4.7.1 OF 2010 | | | FBC-ENERGY CONSERVATION. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561)805-6712 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2014-02-06 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2014-02-06 |
Time |
15:50 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2014-02-06 |
Time |
15:50 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2014-03-03 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2014-03-03 |
Time |
17:53 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2014-03-03 |
Time |
17:53 |
Sent To |
|
|
| Notes |
| 2014-03-03 17:54:39 | 1- GAF SHINGLES NOA 12-0905.14. | | | | | | 2- COBRA RIDGE VENT NOA 13-0509.07. |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2014-02-06 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2014-02-06 |
Time |
14:46 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2014-02-06 |
Time |
14:46 |
Sent To |
|
|
| Notes |
| 2014-02-06 14:48:09 | 1- SHINGLES NOA 11-0223.11 SUBMITTED WAS SUPERSEDED BY | | | MIAMI-DADE. NEED TO PROVIDE CURRENT NOA. | | | | | | 2- COBRA RIDGE VENT NOA 13-0509.07 IS OK. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2014-01-28 |
|
|
Cont ID |
|
| Sent By |
dkittred |
Date |
2014-01-27 |
Time |
17:19 |
Rev Time |
0.00 |
| Received By |
dkittred |
Date |
2014-01-27 |
Time |
14:41 |
Sent To |
|
|
| Notes |
| 2014-01-27 15:03:57 | 1/27/14 - SENT BACK TO R01 | | | | | 2014-01-27 15:03:34 | HOUSE REMODEL WITH NO CHANGE OR ALTERATION TO BUILDING | | | FOOTPRINT. | | 2014-01-21 11:02:35 | 1/21/14 |
|
|