| Plan Review Stops For Permit 14010707 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2014-03-03 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2014-03-03 |
Time |
14:54 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2014-03-03 |
Time |
14:54 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2014-02-05 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2014-02-05 |
Time |
10:55 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2014-02-05 |
Time |
10:55 |
Sent To |
|
|
| Notes |
| 2014-02-05 13:24:32 | RESIDENTIAL (R3) ALTERATION/RENOVATION, BUILDING REVIEW | | | COMMENTS. | | | CODE: 2010 FBC. | | | | | | 1- PROVIDE HURRICANE SHUTTERS COMPLETE INSTALLATION | | | SCHEDULE. AND, CLEARLY SPECIFY MOUNTING CONDITIONS AND | | | ANCHOR TYPE AND SPACING. SEE CITY SAMPLE OR PROVIDE ANY | | | FORMAT THAT SHOWS ALL THE INFORMATION REQUIRED ON THE | | | CITY SAMPLE. SEC. 107.2.1 CITY AMENDMENTS TO FBC. | | | | | | 2- CLEARLY SPECIFY EXISTING BEDROOM WINDOW TYPE AND | | | SIZE AND PROPOSED WINDOW TYPE AND SIZE TO VERIFY | | | COMPLIANCE WITH THE EGRESS REQUIREMENTS OF SEC. R310 OF | | | 2010 FBC-RESIDENTIAL. | | | | | | 3- PROVIDE COPY OF SIGNED CONTRACT WITH THE CITY | | | AFFORDABLE HOUSING PROGRAM TO VERIFY VALUATION. SEC. | | | 109.3 CITY AMENDMENTS TO FBC. | | | | | | 4- ENERGY CALCULATIONS: | | | A) OWNER/AGENT TO CERTIFY AND DATE BOTTOM OF FORM. SEC. | | | 103.2.3.2 OF 2010 FBC-ENERGY CONSERVATION. | | | | | | B) ITEM #7: PROVIDE DOOR AND WINDOW MANUFACTURER'S | | | SPECS SHOWING THE U-FACTOR AND SHGC FACTOR SHOWN ON THE | | | CALCULATIONS AS REQUIRED BY SEC. 103.2.2 OF 2010 | | | FBC-ENERGY CONSERVATION. | | | | | | C) PAGE 2 OF 5 IS TAKING THE WHOLE HOUSE FAN CREDIT. | | | PROVIDE COMPLETE SPECIFICATIONS SHOWING HOW HOUSE IS | | | COMPLYING WITH THIS CREDIT. SEE SEC. 405.6.5 OF 2010 | | | FBC-ENERGY CONSERVATION. | | | | | | 5- PROVIDE SKETCH SHOWING LOCATION AND SIZE OF ALL | | | WINDOWS (INCLUDING ALL WINDOW MULLIONS) AND DOORS TO | | | VERIFY COMPLIANCE WITH THE DESIGN PRESSURES OF SEC. | | | R301 OF 2010 FBC-RESIDENTIAL. THIS BUILDING IS LOCATED | | | IN EXPOSURE 'D". | | | | | | 6- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY | | | DCA RULE 9N-3 FOR; | | | A) SINGLE HUNG WINDOWS THAT MEET THE DESIGN PRESSURES | | | FOR WINDOWS THAT ARE LOCATED CLOSE TO THE END WALLS. | | | DESIGN PRESSURES ARE HIGHER AT THE END WALLS ( 4'-0" | | | WITHIN THE CORNER). | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561)805-6712 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2014-02-27 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2014-03-03 |
Time |
17:22 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2014-02-27 |
Time |
12:12 |
Sent To |
|
|
| Notes |
| 2014-02-27 13:14:19 | ISSUED WITH PROVISO | | | | | | LOCATION OF NEW PANEL SHALL OBSERVE REQUIRED SAFETY | | | CLEARANCES. NEC 110.26 | | | | | | REMODELING OF AN EXISTING STRUCTURE IS REQUIRED TO | | | INCLUDE INTERCONNECTED SMOKE DETECTORS. IF THE | | | RESIDENCE HAS GAS APPLIANCES, AN ATTACHED GARAGE OR A | | | FIRE PLACE A CARBON MONOXIDE DETECTOR IS REQUIRED | | | WITHIN TEN FEET OF EACH ROOM USED FOR SLEEPING. FBC | | | R313 | | | | | | KITCHEN COUNTER TOP RECEPTACLES TO BE GFCI PROTECTED. | | | NEC 210.8 | | | | | | GFCI PROTECTED RECEPTACLES ARE REQUIRED AT FRONT AND | | | REAR ELEVATIONS. NEC 210.8 | | | | | | PROVIDE A 20 AMPERE BRANCH CIRCUIT FOR THE BATHROOMS. | | | NEC 210.11 (C)(3) | | | | | | THE LIVING AREA REQUIRES A SWITCHED RECEPTACLE OR LIGHT | | | AND SWITCH CONTROLLED OUTSIDE LIGHTS. NEC 210.70 | | | | | | ADD RECEPTACLES SO THAT NO WALL SPACE IS MORE THAN 6 | | | FEET FROM A RECEPTACLE AND ALL WALL SPACES MORE THAN 2 | | | FEET IN WIDTH HAVE A RECEPTACLE. NEC 210.52 | | | | | | | | | | | | ROBERT LECKY | | | ELECTRICAL PLANS EXAMINER | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2014-02-18 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2014-02-18 |
Time |
12:37 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2014-02-18 |
Time |
12:36 |
Sent To |
|
|
| Notes |
| 2014-02-18 12:38:01 | 14010707 | | | 1402 7TH STREET | | | REHABILITATION | | | | | | PLEASE REVISE THE PLANS IN RESPONSE TO THE FOLLOWING | | | ELECTRICAL REVIEW COMMENTS. | | | | | | THE SCOPE OF THE PROPOSED ELECTRICAL WORK IS NOT CLEAR. | | | PROVIDE A DETAILED ELECTRICAL PLAN FOR ALL | | | IMPROVEMENTS. | | | | | | INDICATE THE SIZE, RATING, LOCATION OF THE NEW ELECTRIC | | | SERVICE, MAIN DISCONNECT AND PANEL BOARD. SHOW SERVICE | | | AND PANEL BOARD LOCATIONS. SHOW NEW AND EXISTING | | | OUTLETS. INCLUDE A PANEL SCHEDULE WITH SUMMARY LOAD | | | CALCULATION. NEC 215.5 | | | | | | ALL NEW GENERAL PURPOSE OUTLETS MUST BE AFCI PROTECTED. | | | NEC 210.12 | | | | | | NEW RECEPTACLES MUST BE TAMPER RESISTANT. NEC 406.11 | | | | | | REMODELING OF AN EXISTING STRUCTURE IS REQUIRED TO | | | INCLUDE INTERCONNECTED SMOKE DETECTORS. IF THE | | | RESIDENCE HAS GAS APPLIANCES, AN ATTACHED GARAGE OR A | | | FIRE PLACE A CARBON MONOXIDE DETECTOR IS REQUIRED | | | WITHIN TEN FEET OF EACH ROOM USED FOR SLEEPING. FBC | | | R313 | | | | | | SHOW THE KITCHEN COUNTER TOP RECEPTACLES TO BE GFCI | | | PROTECTED. NEC 210.8 | | | | | | GFCI PROTECTED RECEPTACLES ARE REQUIRED AT FRONT AND | | | REAR ELEVATIONS. NEC 210.8 | | | | | | PROVIDE TWO OR MORE 20- AMPERE SMALL APPLIANCE BRANCH | | | CIRCUITS. NEC 210.52 | | | | | | PROVIDE A 20 AMPERE BRANCH CIRCUIT FOR THE BATHROOMS. | | | NEC 210.11 (C)(3) | | | | | | THE LIVING AREA REQUIRES A SWITCHED RECEPTACLE OR LIGHT | | | AND SWITCH CONTROLLED OUTSIDE LIGHTS. NEC 210.70 | | | | | | ADD RECEPTACLES SO THAT NO WALL SPACE IS MORE THAN 6 | | | FEET FROM A RECEPTACLE AND ALL WALL SPACES MORE THAN 2 | | | FEET IN WIDTH HAVE A RECEPTACLE. NEC 210.52 | | | | | | A BONDING STRIP IS REQUIRED AT THE ELECTRIC SERVICE | | | GROUND NEC 250.94 | | | | | | | | | ROBERT LECKY | | | ELECTRICAL PLANS EXAMINER | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2014-03-03 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2014-02-27 |
Time |
11:16 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2014-02-27 |
Time |
11:16 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2014-02-18 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2014-02-18 |
Time |
12:38 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2014-01-14 |
Time |
08:35 |
Sent To |
|
|
| Notes |
| 2014-01-15 08:36:02 | SENT TO R1 SHELF FOR REVIEW. JG. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2014-03-05 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2014-03-05 |
Time |
12:06 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2014-03-05 |
Time |
12:06 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2014-03-04 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2014-03-03 |
Time |
17:16 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2014-03-03 |
Time |
17:16 |
Sent To |
|
|
| Notes |
| 2014-03-03 17:17:57 | 1- TALKED TO MR. LIONEL. REVISE EQUIPMENT TO MATCH LOAD | | | CALCULATIONS. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2014-02-05 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2014-02-05 |
Time |
14:37 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2014-02-05 |
Time |
14:37 |
Sent To |
|
|
| Notes |
| 2014-02-05 14:38:37 | RESIDENTIAL (R3) ALTERATION/RENOVATION, MECHANICAL | | | REVIEW COMMENTS. | | | CODE: 2010 FBC. | | | | | | 1- A/C PLAN PROVIDED; | | | A) NEED TO PROVIDE ALL THE EQUIPMENT SPECIFICATIONS FOR | | | THE EQUIPMENT LISTED IN THE EQUIPMENT SIZING | | | CALCULATIONS. SEC. 103.2.2 OF 2010 FBC-ENERGY | | | CONSERVATION. | | | | | | B) WHERE IS THE CONDENSER UNIT LOCATED?. SEC. 103.2.2 | | | | | | C) PROVIDE THE NAME AND SIGNATURE OF THE PERSON | | | RESPONSIBLE FOR THE DESIGN. SEC. 107.2.1 CITY | | | AMENDMENTS TO FBC. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561)805-6712 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2014-02-05 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2014-02-05 |
Time |
16:32 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2014-02-05 |
Time |
16:32 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2014-01-27 |
|
|
Cont ID |
|
| Sent By |
dkittrid |
Date |
2014-01-27 |
Time |
14:52 |
Rev Time |
0.00 |
| Received By |
dkittred |
Date |
2014-01-27 |
Time |
14:41 |
Sent To |
|
|
| Notes |
| 2014-01-27 14:53:11 | 1/27/14 - SENT BACK R01 | | | | | 2014-01-27 14:52:17 | REMODEL WITH NO CHANGES OR ALTERATION IN BUILDING | | | FOOTPRINT. | | 2014-01-21 11:01:55 | 1/21/14 |
|
|