| Plan Review Stops For Permit 14010472 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2014-06-19 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2014-06-19 |
Time |
12:07 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2014-06-19 |
Time |
12:07 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2014-05-28 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2014-05-28 |
Time |
08:51 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2014-05-28 |
Time |
08:51 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2014-05-17 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2014-05-17 |
Time |
07:25 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2014-05-17 |
Time |
07:25 |
Sent To |
|
|
| Notes |
| 2014-05-17 07:25:53 | 1ST REVIEW: | | | | | | THE APPLICANT HAS UPLOADED TWO SEPARATE DESIGNS FOR THE | | | SPACE. PLEASE RESUBMIT WITH THE DESIGN YOU PLAN TO | | | CONSTRUCT ONLY. NO REVIEW CAN PROCEED UNTIL THIS MATTER | | | IS CLARIFIED. DO THIS FOR THE ENTIRE FILE REGARDLESS OF | | | APPROVAL IN MECHANICAL AND FIRE. | | | | | | THANK YOU, | | | | | | | | | STEVEN KENNEDY, CBO | | | CHIEF PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES | | | BUILDING DIVISION | | | (561) 805-6710 | | | [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
N |
Date |
2014-04-21 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2014-04-21 |
Time |
13:43 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2014-04-21 |
Time |
13:43 |
Sent To |
|
|
| Notes |
| 2014-04-21 13:46:41 | NO REVIEW, REDESIGN TO BE RESUBMITTED. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2014-05-27 |
|
|
Cont ID |
|
| Sent By |
albarran |
Date |
2014-05-27 |
Time |
16:38 |
Rev Time |
0.00 |
| Received By |
albarran |
Date |
2014-05-27 |
Time |
15:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2014-05-06 |
|
|
Cont ID |
|
| Sent By |
albarran |
Date |
2014-05-06 |
Time |
18:44 |
Rev Time |
0.00 |
| Received By |
albarran |
Date |
2014-05-06 |
Time |
15:11 |
Sent To |
|
|
| Notes |
| 2014-05-06 18:47:08 | THESE DRAWINGS ARE NOT A MATCH ALL THE WAY THROUGH. | | | SEVERAL CHANGES HAVE BEEN MADE ON INDIVIDUAL PAGES W/O | | | CORRECTING THE SUBSEQUENT PAGES. SEE ELECTRICAL COMMENT | | | LAYER FOR DETAILS. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
N |
Date |
2014-04-21 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2014-04-21 |
Time |
13:46 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2014-04-21 |
Time |
13:46 |
Sent To |
|
|
| Notes |
| 2014-04-21 13:48:27 | NO REVIEW, REDESIGN TO BE RESUBMITTED. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
4 |
Status |
P |
Date |
2014-06-25 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2014-06-25 |
Time |
17:46 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2014-06-25 |
Time |
17:05 |
Sent To |
|
|
| Notes |
| 2014-06-25 17:46:14 | 1835 OKEECHOBEE ROAD | | | PERMIT #14010472 | | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | | | NEW COMMENT - SHEET A3.1: IN LIEU OF PANIC HARDWARE | | | (EXISTING STORE FRONT DOORS), KEY OPERATED LOCKS ARE | | | PERMISSIBLE ON THE MAIN ENTRANCE DOOR(S) IF THE | | | FOLLOWING IS PROVIDED: | | | (1) A READILY VISIBLE, DURABLE SIGN IN LETTERS NOT LESS | | | THAN 1-INCH HIGH ON A CONTRASTING BACKGROUND THAT READS | | | AS FOLLOWS IS LOCATED ON OR ADJACENT TO THE DOOR LEAF: | | | THIS DOOR TO REMAIN UNLOCKED WHEN THE BUILDING IS | | | OCCUPIED. | | | (2) THE LOCKING DEVICE IS OF A TYPE THAT IS READILY | | | DISTINGUISHABLE AS LOCKED (EQUIVALENT TO ADAMSRITE | | | #4089) | | | (3) A KEY IS IMMEDIATELY AVAILABLE TO ANY OCCUPANT | | | INSIDE THE BUILDING WHEN IT IS LOCKED. | | | | | | WESLEY JOLIN | | | ASSISTANT FIRE MARSHAL | | | FIRE INVESTIGATOR & INSPECTOR | | | OFFICE OF THE FIRE MARSHAL | | | WEST PALM BEACH FIRE RESCUE | | | [email protected] | | | (561) 805-6730 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
F |
Date |
2014-05-23 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2014-05-23 |
Time |
10:07 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2014-05-23 |
Time |
10:02 |
Sent To |
|
|
| Notes |
| 2014-05-23 10:07:29 | 1835 OKEECHOBEE ROAD | | | PERMIT #14010472 | | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | | | REPEAT COMMENT - SHEET A1.2: INDICATE THE COMMODITIES | | | THAT WILL BE STORED (FLOOR AND RACKING SYSTEM) AND THE | | | INTENDED HEIGHT OF STORAGE. NOTE: STORAGE EXCEEDING 12 | | | FEET IN ELEVATION IS CONSIDERED HIGH-PILED STORAGE AND | | | MAY REQUIRE SPECIAL SPRINKLER PROTECTION. | | | | | | REPEAT COMMENT - SHEET A3.1: PANIC HARDWARE WILL BE | | | REQUIRED ON ALL NEW AND EXISTING EXIT AND EXIT ACCESS | | | DOORS DUE TO THE ASSEMBLY OCCUPANT LOAD EXCEEDING 100 | | | PERSONS (50 PERSONS PER FBC) AND USING THE MIXED | | | NON-SEPARATED OCCUPANCY DESIGN (PER THE COVER SHEET | | | DESCRIPTION). IF SEPARATED OCCUPANCIES ARE DESIRED, THE | | | ASSEMBLY AND BUSINESS OCCUPANCIES WOULD BE PROHIBITED | | | FROM HAVING TO EXIT THROUGH THE STORAGE OCCUPANCY AS IS | | | CURRENTLY SHOWN. | | | | | | REPEAT COMMENT - GENERAL: PER SECTION 8.3.2.4, EACH | | | FIRE BARRIER SHALL BE PERMANENTLY IDENTIFIED WITH SIGNS | | | OR STENCILING READING FIRE BARRIER-PROTECT ALL | | | OPENINGS. CHARACTERS SHALL BE AT LEAST 4-INCHES IN | | | HEIGHT AND HALF-INCH IN WIDTH. IDENTIFICATION SHALL BE | | | SPACED NOT MORE THAN 15 FEET ON CENTER. | | | | | | REPEAT COMMENT - GENERAL: NO FIRE PROTECTION | | | ENGINEERING DOCENTS SUBMITTED. FOR ISSUANCE OF A | | | GENERAL BUILDING PERMIT, SECTION 105.3.1.2(2) OF THE | | | FLORIDA BUILDING CODE REQUIRES SEALED FIRE PROTECTION | | | CONSTRUCTION DOCUMENTS FOR THE DESIGN OR ALTERATION OF | | | 50 OR MORE AUTOMATIC FIRE SPRINKLERS. PER FLORIDA | | | ADMINISTRATIVE CODE SECTION 61G15-32.004, FIRE | | | PROTECTION ENGINEERING DOCUMENTS SHALL INCLUDE THE | | | POINT OF SERVICE FOR THE WATER SUPPLY, A LIST OF | | | APPLICABLE NFPA STANDARDS APPLICABLE TO THE PROJECT, | | | CLASSIFICATION OF HAZARD OCCUPANCY FOR EACH ROOM OR | | | AREA, SUPPRESSION SYSTEM TYPE, DESIGN DENSITIES, WATER | | | SUPPLY DATA (FIRE PUMP DATA, HYDRANT FLOW TEST DATA) | | | AND ANY PERFORMANCE BASED INFORMATION SUCH AS | | | PRE-ENGINEERED SYSTEMS. | | | | | | REPEAT COMMENT - DEMO: PROVIDE DRAWING NOTE INDICATING | | | ALL CONSTRUCTION AND DEMOLITION WORK SHALL CONFORM TO | | | THE REQUIREMENTS OF NFPA 241. TRASH AND CONSTRUCTION | | | DEBRIS SHALL BE REMOVED FROM THE SITE DAILY. SMOKING | | | SHALL BE PROHIBITED EXCEPT IN DESIGNATED EXTERIOR | | | AREAS. ALL OTHER DEMOLITION OR CONSTRUCTION AREAS SHALL | | | HAVE "NO SMOKING" SIGNS POSTED. WHERE SMOKING IS | | | PERMITTED, SAFE RECEPTACLES FOR SMOKING MATERIALS SHALL | | | BE PROVIDED. | | | | | | REPEAT COMMENT - DEMO: PROVIDE DRAWING NOTE INDICATING, | | | "FIRE PROTECTION SYSTEMS SHALL REMAIN ACTIVE DURING | | | DEMOLITION AND RENOVATION ACTIVITIES. IN THE EVENT A | | | FIRE PROTECTION SYSTEM IS OUT OF SERVICE FOR MORE THAN | | | 4-HOURS IN A 24-HOUR PERIOD, THE BUILDING SHALL BE | | | PLACED UNDER A FIRE WATCH. ALL FIRE WATCH REQUESTS MUST | | | BE SUBMITTED BY EMAIL ([email protected]) OR IN WRITING | | | (FAX: 561-804-4774) AND APPROVED BY THE OFFICE OF THE | | | FIRE MARSHAL LOCATED AT 500 NORTH DIXIE HIGHWAY." | | | | | | WESLEY JOLIN | | | ASSISTANT FIRE MARSHAL | | | FIRE INVESTIGATOR & INSPECTOR | | | OFFICE OF THE FIRE MARSHAL | | | WEST PALM BEACH FIRE RESCUE | | | [email protected] | | | (561) 805-6730 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
2014-04-25 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2014-04-25 |
Time |
17:37 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2014-04-25 |
Time |
17:22 |
Sent To |
|
|
| Notes |
| 2014-04-25 17:37:12 | 1835 OKEECHOBEE ROAD | | | PERMIT #14010472 | | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | | | REPEAT COMMENT - SHEET A1.2: INDICATE THE COMMODITIES | | | THAT WILL BE STORED (FLOOR AND RACKING SYSTEM) AND THE | | | INTENDED HEIGHT OF STORAGE. NOTE: STORAGE EXCEEDING 12 | | | FEET IN ELEVATION IS CONSIDERED HIGH-PILED STORAGE AND | | | MAY REQUIRE SPECIAL SPRINKLER PROTECTION. | | | | | | REPEAT COMMENT - SHEET A3.1: PANIC HARDWARE WILL BE | | | REQUIRED ON ALL NEW AND EXISTING EXIT AND EXIT ACCESS | | | DOORS DUE TO THE ASSEMBLY OCCUPANT LOAD EXCEEDING 100 | | | PERSONS (50 PERSONS PER FBC) AND USING THE MIXED | | | NON-SEPARATED OCCUPANCY DESIGN (PER THE COVER SHEET | | | DESCRIPTION). IF SEPARATED OCCUPANCIES ARE DESIRED, THE | | | ASSEMBLY AND BUSINESS OCCUPANCIES WOULD BE PROHIBITED | | | FROM HAVING TO EXIT THROUGH THE STORAGE OCCUPANCY AS IS | | | CURRENTLY SHOWN. | | | | | | REPEAT COMMENT - GENERAL: PER SECTION 8.3.2.4, EACH | | | FIRE BARRIER SHALL BE PERMANENTLY IDENTIFIED WITH SIGNS | | | OR STENCILING READING FIRE BARRIER-PROTECT ALL | | | OPENINGS. CHARACTERS SHALL BE AT LEAST 4-INCHES IN | | | HEIGHT AND HALF-INCH IN WIDTH. IDENTIFICATION SHALL BE | | | SPACED NOT MORE THAN 15 FEET ON CENTER. | | | | | | REPEAT COMMENT - GENERAL: NO FIRE PROTECTION | | | ENGINEERING DOCENTS SUBMITTED. FOR ISSUANCE OF A | | | GENERAL BUILDING PERMIT, SECTION 105.3.1.2(2) OF THE | | | FLORIDA BUILDING CODE REQUIRES SEALED FIRE PROTECTION | | | CONSTRUCTION DOCUMENTS FOR THE DESIGN OR ALTERATION OF | | | 50 OR MORE AUTOMATIC FIRE SPRINKLERS. PER FLORIDA | | | ADMINISTRATIVE CODE SECTION 61G15-32.004, FIRE | | | PROTECTION ENGINEERING DOCUMENTS SHALL INCLUDE THE | | | POINT OF SERVICE FOR THE WATER SUPPLY, A LIST OF | | | APPLICABLE NFPA STANDARDS APPLICABLE TO THE PROJECT, | | | CLASSIFICATION OF HAZARD OCCUPANCY FOR EACH ROOM OR | | | AREA, SUPPRESSION SYSTEM TYPE, DESIGN DENSITIES, WATER | | | SUPPLY DATA (FIRE PUMP DATA, HYDRANT FLOW TEST DATA) | | | AND ANY PERFORMANCE BASED INFORMATION SUCH AS | | | PRE-ENGINEERED SYSTEMS. | | | | | | REPEAT COMMENT - DEMO: PROVIDE DRAWING NOTE INDICATING | | | ALL CONSTRUCTION AND DEMOLITION WORK SHALL CONFORM TO | | | THE REQUIREMENTS OF NFPA 241. TRASH AND CONSTRUCTION | | | DEBRIS SHALL BE REMOVED FROM THE SITE DAILY. SMOKING | | | SHALL BE PROHIBITED EXCEPT IN DESIGNATED EXTERIOR | | | AREAS. ALL OTHER DEMOLITION OR CONSTRUCTION AREAS SHALL | | | HAVE "NO SMOKING" SIGNS POSTED. WHERE SMOKING IS | | | PERMITTED, SAFE RECEPTACLES FOR SMOKING MATERIALS SHALL | | | BE PROVIDED. | | | | | | REPEAT COMMENT - DEMO: PROVIDE DRAWING NOTE INDICATING, | | | "FIRE PROTECTION SYSTEMS SHALL REMAIN ACTIVE DURING | | | DEMOLITION AND RENOVATION ACTIVITIES. IN THE EVENT A | | | FIRE PROTECTION SYSTEM IS OUT OF SERVICE FOR MORE THAN | | | 4-HOURS IN A 24-HOUR PERIOD, THE BUILDING SHALL BE | | | PLACED UNDER A FIRE WATCH. ALL FIRE WATCH REQUESTS MUST | | | BE SUBMITTED BY EMAIL ([email protected]) OR IN WRITING | | | (FAX: 561-804-4774) AND APPROVED BY THE OFFICE OF THE | | | FIRE MARSHAL LOCATED AT 500 NORTH DIXIE HIGHWAY." | | | | | | WESLEY JOLIN | | | ASSISTANT FIRE MARSHAL | | | FIRE INVESTIGATOR & INSPECTOR | | | OFFICE OF THE FIRE MARSHAL | | | WEST PALM BEACH FIRE RESCUE | | | [email protected] | | | (561) 805-6730 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2014-01-17 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2014-01-17 |
Time |
11:19 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2014-01-17 |
Time |
09:21 |
Sent To |
|
|
| Notes |
| 2014-01-17 11:19:19 | 1835 OKEECHOBEE ROAD | | | PERMIT #14010472 | | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | | | SHEET A1.2: INDICATE THE COMMODITIES THAT WILL BE | | | STORED (FLOOR AND RACKING SYSTEM) AND THE INTENDED | | | HEIGHT OF STORAGE. NOTE: STORAGE EXCEEDING 12 FEET IN | | | ELEVATION IS CONSIDERED HIGH-PILED STORAGE AND MAY | | | REQUIRE SPECIAL SPRINKLER PROTECTION. | | | | | | SHEET A3.1: PANIC HARDWARE WILL BE REQUIRED ON ALL NEW | | | AND EXISTING EXIT AND EXIT ACCESS DOORS DUE TO THE | | | ASSEMBLY OCCUPANT LOAD EXCEEDING 100 PERSONS (50 | | | PERSONS PER FBC) AND USING THE MIXED NON-SEPARATED | | | OCCUPANCY DESIGN (PER THE COVER SHEET DESCRIPTION). IF | | | SEPARATED OCCUPANCIES ARE DESIRED, THE ASSEMBLY AND | | | BUSINESS OCCUPANCIES WOULD BE PROHIBITED FROM HAVING TO | | | EXIT THROUGH THE STORAGE OCCUPANCY AS IS CURRENTLY | | | SHOWN. | | | | | | SHEET FA2.1: NO FIRE ALARM NOTIFICATION APPLIANCE | | | LOCATED AT THE SOUTHEAST AREA OF THE SPACE. | | | | | | GENERAL: PER SECTION 8.3.2.4, EACH FIRE BARRIER SHALL | | | BE PERMANENTLY IDENTIFIED WITH SIGNS OR STENCILING | | | READING FIRE BARRIER-PROTECT ALL OPENINGS. CHARACTERS | | | SHALL BE AT LEAST 4-INCHES IN HEIGHT AND HALF-INCH IN | | | WIDTH. IDENTIFICATION SHALL BE SPACED NOT MORE THAN 15 | | | FEET ON CENTER. | | | | | | GENERAL: NO FIRE PROTECTION ENGINEERING DOCENTS | | | SUBMITTED. FOR ISSUANCE OF A GENERAL BUILDING PERMIT, | | | SECTION 105.3.1.2(2) OF THE FLORIDA BUILDING CODE | | | REQUIRES SEALED FIRE PROTECTION CONSTRUCTION DOCUMENTS | | | FOR THE DESIGN OR ALTERATION OF 50 OR MORE AUTOMATIC | | | FIRE SPRINKLERS. PER FLORIDA ADMINISTRATIVE CODE | | | SECTION 61G15-32.004, FIRE PROTECTION ENGINEERING | | | DOCUMENTS SHALL INCLUDE THE POINT OF SERVICE FOR THE | | | WATER SUPPLY, A LIST OF APPLICABLE NFPA STANDARDS | | | APPLICABLE TO THE PROJECT, CLASSIFICATION OF HAZARD | | | OCCUPANCY FOR EACH ROOM OR AREA, SUPPRESSION SYSTEM | | | TYPE, DESIGN DENSITIES, WATER SUPPLY DATA (FIRE PUMP | | | DATA, HYDRANT FLOW TEST DATA) AND ANY PERFORMANCE BASED | | | INFORMATION SUCH AS PRE-ENGINEERED SYSTEMS. | | | | | | DEMO: PROVIDE DRAWING NOTE INDICATING ALL CONSTRUCTION | | | AND DEMOLITION WORK SHALL CONFORM TO THE REQUIREMENTS | | | OF NFPA 241. TRASH AND CONSTRUCTION DEBRIS SHALL BE | | | REMOVED FROM THE SITE DAILY. SMOKING SHALL BE | | | PROHIBITED EXCEPT IN DESIGNATED EXTERIOR AREAS. ALL | | | OTHER DEMOLITION OR CONSTRUCTION AREAS SHALL HAVE "NO | | | SMOKING" SIGNS POSTED. WHERE SMOKING IS PERMITTED, SAFE | | | RECEPTACLES FOR SMOKING MATERIALS SHALL BE PROVIDED. | | | | | | DEMO: PROVIDE DRAWING NOTE INDICATING, ?FIRE PROTECTION | | | SYSTEMS SHALL REMAIN ACTIVE DURING DEMOLITION AND | | | RENOVATION ACTIVITIES. IN THE EVENT A FIRE PROTECTION | | | SYSTEM IS OUT OF SERVICE FOR MORE THAN 4-HOURS IN A | | | 24-HOUR PERIOD, THE BUILDING SHALL BE PLACED UNDER A | | | FIRE WATCH. ALL FIRE WATCH REQUESTS MUST BE SUBMITTED | | | BY EMAIL ([email protected]) OR IN WRITING (FAX: | | | 561-804-4774) AND APPROVED BY THE OFFICE OF THE FIRE | | | MARSHAL LOCATED AT 500 NORTH DIXIE HIGHWAY.? | | | | | | WESLEY JOLIN | | | ASSISTANT FIRE MARSHAL | | | FIRE INVESTIGATOR & INSPECTOR | | | OFFICE OF THE FIRE MARSHAL | | | WEST PALM BEACH FIRE RESCUE | | | [email protected] | | | (561) 805-6730 | | | | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2014-06-27 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2014-07-03 |
Time |
13:04 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2014-06-06 |
Time |
21:47 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2014-05-28 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2014-05-28 |
Time |
11:42 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2014-05-28 |
Time |
11:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2014-05-17 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2014-05-17 |
Time |
07:26 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2014-04-21 |
Time |
16:27 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2014-01-21 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2014-01-21 |
Time |
10:02 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2014-01-09 |
Time |
15:45 |
Sent To |
|
|
| Notes |
| 2014-01-21 10:03:02 | REVIEW CYCLE CLOSED DUE TO CUSTOMER REQUEST. SEE EMAIL | | | ATTACHED TO PERMIT RECORD. |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
N |
Date |
2014-05-17 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2014-05-17 |
Time |
07:09 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
N |
Date |
2014-04-21 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2014-04-21 |
Time |
13:47 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2014-04-21 |
Time |
13:47 |
Sent To |
|
|
| Notes |
| 2014-04-21 13:48:11 | NO REVIEW, REDESIGN TO BE RESUBMITTED. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2014-06-26 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2014-06-26 |
Time |
09:28 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2014-06-26 |
Time |
09:28 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2014-05-28 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2014-05-28 |
Time |
11:41 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2014-05-28 |
Time |
11:41 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2014-05-14 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2014-05-14 |
Time |
13:18 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2014-05-14 |
Time |
13:18 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2014-01-09 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2014-01-09 |
Time |
16:56 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2014-01-09 |
Time |
16:56 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2014-05-28 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2014-05-28 |
Time |
08:42 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2014-05-28 |
Time |
08:40 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2014-05-17 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2014-05-17 |
Time |
07:21 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2014-05-17 |
Time |
07:09 |
Sent To |
|
|
| Notes |
| 2014-05-17 07:25:11 | 1ST REVIEW: | | | | | | THE APPLICANT HAS UPLOADED TWO SEPARATE DESIGNS FOR THE | | | SPACE. PLEASE RESUBMIT WITH THE DESIGN YOU PLAN TO | | | CONSTRUCT ONLY. NO REVIEW CAN PROCEED UNTIL THIS MATTER | | | IS CLARIFIED. DO THIS FOR THE ENTIRE FILE REGARDLESS OF | | | APPROVAL IN MECHANICAL AND FIRE. | | | | | | THANK YOU, | | | | | | | | | STEVEN KENNEDY, CBO | | | CHIEF PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES | | | BUILDING DIVISION | | | (561) 805-6710 | | | [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
N |
Date |
2014-04-21 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2014-04-21 |
Time |
13:47 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2014-04-21 |
Time |
13:47 |
Sent To |
|
|
| Notes |
| 2014-04-21 13:48:41 | NO REVIEW, REDESIGN TO BE RESUBMITTED. |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2014-07-02 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2014-07-02 |
Time |
07:57 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2014-07-02 |
Time |
07:53 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2014-07-01 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2014-07-01 |
Time |
07:27 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2014-06-30 |
Time |
07:06 |
Sent To |
|
|
| Notes |
| 2014-07-01 07:27:48 | PEDDS MISSING FOR SHEETS GN, D1.1, A1.2, A3.2, A4.1, & | | | A4.2. |
|
|