Plan Review Details - Permit 14010350
Plan Review Stops For Permit 14010350
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2014-03-11 Cont ID  
Sent By jwitmer Date 2014-03-11 Time 13:37 Rev Time 0.00
Received By jwitmer Date 2014-03-11 Time 13:27 Sent To  
Notes
2014-03-11 13:35:20BUILDING PLAN REVIEW
 PERMIT: 14010350
 ADD: 1801 PALM BEACH LAKES
 CONT: EMJ CONSTRUCTION
 TEL: (561)373-3902
  
 2010 FLORIDA BUILDING CODE W
 * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION
 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013.
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
 2ND REVIEW
 DATE: TUES. MARCH 11/ 2014
 ACTION:
 BUILDING PROVISO
  
 1) THE COVERSHEET OF THE STATE APPROVED PLANS SITE
 INSTALLED ITEMS # 2, STAIRS & RAMPS. THIS STRUCTURE IS
 BEING USED FOR THE STORAGE OF MATERIALS AND OFFICE FOR
 THE CONSRUCTION PURPOSES ONLY, NO PUBLIC WILL BE
 INVITED INTO THIS STRUCTURE.
  
 AS DISCUSSED IN EARLIER MEETINGS THIS MANUFACTURERED
 BUILDING IS ON SITE AND BEING MOVED TO A NEW LOCATION
 ON THE SAME SITE. THE SITE BUILT STAIRS AND GAURDRAIL/
 HANDRAIL SYSTEM WILL ALSO BE RELOCATED ALONG WITH THE
 MANUFACTURED BUILDING.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2014-01-13 Cont ID  
Sent By jwitmer Date 2014-01-13 Time 10:56 Rev Time 0.00
Received By jwitmer Date 2014-01-13 Time 10:55 Sent To  
Notes
2014-01-13 11:14:49BUILDING PLAN REVIEW
 PERMIT: 14010350
 ADD: 1801 PALM BEACH LAKES
 CONT: EMJ CONSTRUCTION
 TEL: (561)373-3902
  
 2010 FLORIDA BUILDING CODE W
 * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION
 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013.
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
 1ST
 REVIEW
 DATE: MON. JAN. 13/ 2014
 ACTION: DENIED
  
 1) THE COVERSHEETOF THE STATE APPROVED PLANS SITE
 INSTALLED ITEMS # 2, STAIRS & RAMPS. IF THIS STRUCTURE
 IS BEING USED FOR THE STORAGE OF MATERIALS ONLY THEN
 PLANS FOR THE STAIR, LANDING AND GAURDRAIL/ HANDRAIL
 SYSTEM WILL BE REQUIRED. IF THIS STRUCTURE WILL BE USED
 AS OFFICES WHERE PUBLIC, SUB-CONTRACTORS, MATERIAL
 VENDORS WILL BE CONDUCTING BUSINESS THEN ACCESSIBLE
 RAMPS WILL BE REQUIRED WITH GAURDRAIL/ HANDRAIL
 SYSTEMS.
 * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION
 107.3.5 MINIMUM PLAN REVIEW CRITERIA FOR BUILDINGS. THE
 EXAMINATION OF THE DOCUMENTS BY THE BUILDING OFFICIAL
 SHALL INCLUDE THE FOLLOWING MINIMUM CRITERIA AND
 DOCUMENTS:
  
 COMMERCIAL BUILDINGS: 107.3.5.1.1
 1) ACCESSIBLE SITE PARKING
 2) OCCUPANCY LOAD/EGRESS REQUIREMENTS SHALL INCLUDE:
 EXIT DISCHARGE, STAIR & RAMP CONSTRUCTION/GEOMETRY
 3) STRUCTURAL REQUIREMENTS SHALL INCLUDE: STRUCTURAL
 CALCULATIONS STAIRS & RAMPS DESINED IN ACCORDANCE TO
 TABLE 1607.1.
  
 2) SITE PLAN PROVIDED INDICATES THIS BUILDING AS BLDG D
 A 6000 SQ FT RETAIL STORE, DRAWN ON PLAN 24 X60?
 ADDITIONAL INFORMATION REQUIRED?
  
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  
  
  

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2014-01-29 Cont ID  
Sent By albarran Date 2014-01-29 Time 09:25 Rev Time 0.00
Received By albarran Date 2014-01-29 Time 09:00 Sent To I
Notes
2014-01-29 09:28:42IN LIEU OF A PROPERLY DETAILED ELECTRICAL RISER
 DIAGRAM. THIS PERMIT WAS APPROVED WITH A PROVISO
 INDICATING THAT ALL CODE REQUIREMENTS SHALL BE MET AND
 FINAL APPROVAL WILL BE SUBJECT TO FIELD INSPECTOR'S
 APPROVAL.

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2014-01-28 Cont ID  
Sent By albarran Date 2014-01-28 Time 19:59 Rev Time 0.00
Received By albarran Date 2014-01-28 Time 19:44 Sent To  
Notes
2014-01-28 20:05:10AS PER THE MANUFACTURER, THESE UNITS REQUIRE A 100 AMP
 SERVICE EACH. YOU SHALL SUBMIT A RISER DIAGRAM
 INDICATING WHERE THE SOURCE OF ELECTRIC POWER WILL BE
 OBTAINED FROM. IF THE SERVICE WILL BE MOUNTED ON A SELF
 SUPPORTING STAND, PROVIDE ENGINEERING TO MEET THE
 MINIMUM WIND LOADS.

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2014-02-10 Cont ID  
Sent By scaldero Date 2014-02-10 Time 10:55 Rev Time 0.00
Received By scaldero Date 2014-02-10 Time 10:55 Sent To I
Notes
2014-02-10 11:00:03PERMIT #14010350
 REVIEW COMMENTS - FIRE DEPARTMENT
  
 PROVISO:
 ADEQUATE EMERGENCY LIGHTING REQUIRED.
  
  
 SUE ELLEN CALDERON
 FIRE INSPECTOR & INVESTIGATOR
 OFFICE OF THE FIRE MARSHAL
 WEST PALM BEACH FIRE RESCUE
 [email protected]
 (561) 804-4751
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2014-03-11 Cont ID  
Sent By jwitmer Date 2014-03-11 Time 13:37 Rev Time 0.00
Received By jwitmer Date 2014-03-03 Time 14:31 Sent To  
Notes
2014-03-03 14:31:24TO JW DESK
  

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2014-02-26 Cont ID  
Sent By shill Date 2014-02-10 Time 17:01 Rev Time 0.00
Received By shill Date 2014-01-08 Time 17:15 Sent To  
Notes
2014-01-29 09:29:12SENT TO SH DESK
2014-01-09 17:15:51SENT TO B3 SHELF FOR REVIEW. JG.

Review Stop P PLUMBING
Rev No 2 Status P Date 2014-03-11 Cont ID  
Sent By jwitmer Date 2014-03-11 Time 13:37 Rev Time 0.00
Received By jwitmer Date 2014-03-11 Time 13:35 Sent To  
Notes
2014-03-11 13:36:50THE MANUFACTURERED BUILDING WILL HAVE A HOLDING TANK
 FOR SEPTIC SEWAGE REMOVAL.

Review Stop P PLUMBING
Rev No 1 Status F Date 2014-01-13 Cont ID  
Sent By jwitmer Date 2014-01-13 Time 11:14 Rev Time 0.00
Received By jwitmer Date 2014-01-13 Time 10:55 Sent To  
Notes
2014-01-13 11:21:53PLUMBING PLAN REVIEW
 PERMIT: 14010350
 ADD: 1801 PALM BEACH LAKES
 CONT: EMJ CONSTRUCTION
 TEL: (561)373-3902
  
 2010 FLORIDA BUILDING CODE W
 * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION
 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013.
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
 1ST
 REVIEW
 DATE: MON. JAN. 13/ 2014
 ACTION: DENIED
  
 1) THE STATE APPROVED PLANS SHOW A RESTROOM WHICH IS
 STATE APPROVED, WHAT IS NOT SHOWN NOR ANY INFORMATION
 PROVIDED IS COMPLIANCE WITH 2010 FBC-P 701.2 SEWER
 REQUIRED.
 EVERY BUILDING IN WHICH PLUMBING FIXTURES ARE INSTALLED
 AND ALL PREMISES HAVING DRAINAGE PIPING SHALL BE
 CONNECTED TO A PUBLICLY OWNED OR INVESTOR-OWNED SEWAGE
 SYSTEM, WHERE AVAILABLE, OR AN APPROVED ONSITE SEWAGE
 TREATMENT AND DISPOSAL SYSTEM IN ACCORDANCE WITH
 CHAPTER 64E-6, FLORIDA ADMINISTRATIVE CODE, STANDARDS
 FOR ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEMS.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  

Review Stop Z ZONING
Rev No 1 Status P Date 2014-02-06 Cont ID  
Sent By escneid Date 2014-02-06 Time 17:09 Rev Time 0.25
Received By eschneid Date 2014-02-06 Time 17:09 Sent To  
Notes
2014-01-27 14:26:451/27/14