Plan Review Details - Permit 13121049
Plan Review Stops For Permit 13121049
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2014-01-11 Cont ID  
Sent By jwitmer Date 2014-01-11 Time 08:20 Rev Time 0.00
Received By jwitmer Date 2014-01-10 Time 16:05 Sent To  
Notes
2014-01-10 16:44:41BUILDING PLAN REVIEW
 PERMIT: 13121049
 ADD: 10130 NORTHLAKES BLVD # 218
 CONT: VENTURA ARCHITECTURE DEVELOPMENT
 TEL: (954) 423-1362
  
 2010 FLORIDA BUILDING CODE W
 * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION
 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013.
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 1STREVIEW
 DATE: FRIDAY JAN.10/ 2014
 ACTION: PROVISO APPROVED WITH EXCEPTION!
 THIS PLAN HAS BEEN APPROVED PROVISIONALLY. FAILURE TO
 CORRECT THE LISTED DEFICIENCIES IN THIS PLAN PRIOR TO
 INSPECTION WILL RESULT IN FAILED INSPECTION(S) AND THE
 ASSESSMENT OF RE-INSPECTION FEE(S). REVISIONS REQUIRE
 ADDITIONAL REVIEWS WITH ASSOCIATED FEES.
  
 1) THE PRODUCT APPROVAL SUBMITTED FOR THE GLAZED
 STOREFRONT NOA 11-1207.07 TRULITE REGISTER FG-4500/ 450
 EZ IS A NON-IMPACT GLAZED SYSTEM. PLEASE PROVIDE
 COMPLIANCE WITH 2010 FBC-B 1609.1.2 PROTECTION OF
 OPENINGS, 1609.6.4.41 COMPONENTS & CLADDING STORM
 SHUTTERS. FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS RULE
 9N-3 NOV. 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS OR
 CONSTRUCTION SYSTEMS THAT WILL REQUIRE PRODUCT
 APPROVALS:
 (31)(E) SHUTTER.
  
 PROVIDE STORM PANEL INFORMATION WITH INSTALLATION
 SCHEDULE AND KEY PLAN WITH SPECIFIC ANCHORS AND
 MOUNTING TO BE USED FOR ALL NON-IMPACT GLAZING. FBC
 1609.1.4.
  
 FL BLD CODE 2004 SECTION 106.3.3, 1609.1.4, 1714.5.1 &
 EXIST BUILD CODE 507.3. PROCEDURES: 1(B) A COMPLETE
 INSTALLATION SCHEDULE SUMMARIZING & IDENTIFYING OPENING
 SIZES, STORY HEIGHTS, UNIT MARK NUMBERS, UNIT
 SPANS/WIDTHS, UNIT BAR REINFORCING REQUIREMENTS, WALL
 PRESSURE ZONES, SLAT TYPES, ETC.
  
 2) SHEET A2 SECTIONS 1,2 & 3 2010 FBC-ENERGY 502.2.1.2
 CEILING INSULATION. INSULATION INSTALLED ON A SUSPENDED
 CEILING WITH REMOVABLE CEILING TILES SHALL NOT BE
 CONSIDERED PART OF THE MINIMUM THERMAL RESISTANCE OF
 THE ROOF INSULATION UNLESS THE ROOF/CEILING CAVITY IS
 SEALED FROM THE EXTERIOR ENVIRONMENT.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2014-01-30 Cont ID  
Sent By dharvey Date 2014-01-30 Time 13:21 Rev Time 0.00
Received By dharvey Date 2014-01-30 Time 12:05 Sent To  
Notes
2014-01-30 12:05:37BY RL

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2014-01-06 Cont ID  
Sent By scaldero Date 2014-01-06 Time 16:56 Rev Time 0.00
Received By scaldero Date 2014-01-06 Time 16:56 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2014-02-12 Cont ID  
Sent By jwitmer Date 2014-02-12 Time 07:48 Rev Time 0.00
Received By jwitmer Date 2014-02-12 Time 07:48 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2014-02-04 Cont ID  
Sent By hmoser Date 2014-02-04 Time 15:22 Rev Time 0.00
Received By hmoser Date 2013-12-26 Time 16:45 Sent To  
Notes
2013-12-26 16:45:51SENT TO C18 SHELF FOR REVIEW. JG.

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status N Date 2014-02-12 Cont ID  
Sent By jwitmer Date 2014-02-12 Time 07:48 Rev Time 0.00
Received By jwitmer Date 2014-02-12 Time 07:48 Sent To  
Notes
2014-02-12 07:49:27PLANS STAMPED $0.00 DUE. JW

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2014-01-10 Cont ID  
Sent By jwitmer Date 2014-01-10 Time 16:45 Rev Time 0.00
Received By jwitmer Date 2014-01-10 Time 16:45 Sent To  
Notes
2014-01-10 16:45:45BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT
 FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL
 PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND
 A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT
 APPLICATION. PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2014-02-04 Cont ID  
Sent By hmoser Date 2014-02-04 Time 15:21 Rev Time 0.00
Received By hmoser Date 2014-02-04 Time 14:53 Sent To  
Notes
2014-02-04 14:56:59REFER TO PERMIT NUMBER 14010007 SEPARATE APPLICATION,
 PLAN AND PERMIT REQUIRED FOR
 HOOD AND WALK IN COOLERS.
 PLAN REVIEW BY HAROLD MOSER
 [email protected]
 OFFICE 561-805-6732
 FAX 561-805-6676

Review Stop P PLUMBING
Rev No 1 Status P Date 2014-01-11 Cont ID  
Sent By jwitmer Date 2014-01-11 Time 08:26 Rev Time 0.00
Received By jwitmer Date 2014-01-11 Time 08:26 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status P Date 2014-01-29 Cont ID  
Sent By dkittred Date 2014-01-29 Time 15:03 Rev Time 0.00
Received By dkittred Date 2014-01-29 Time 14:26 Sent To  
Notes
2014-01-29 14:38:07PLANNING AND ZONING COMMENTS - 2ND REVIEW OF PLANS
 SUBMITTED ON 12/26/13
  
 REASON FOR RE-REVIEW: DRIVE-THRU USE AND ADDITIONAL
 SQUARE FOOTAGE WAS APPROVED BY ORD. 4502-14 ON 1/21/14.
 INFORMAL SITE PLAN REVIEW WAS APPROVED 1/28/14 FOR THE
 DUNKIN DONUTS DRIVE-THRU.
  
 PLANNING AND ZONING HAS APPROVED THE SUBMITTED BUILDING
 PERMIT WITH A NOTATION ADDED TO THE PLAN THAT THE
 WALK-IN FREEZER/COOLER WILL BE FULLY HIDDEN FROM VIEW
 BY A FENCE CONSISTENT WITH THE INFORMAL SITE PLAN
 APPROVAL. ANY CHANGE TO THIS WILL REQUIRE RE-REVIEW BY
 PLANNING.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT:
  
 DANIELLE J. KITTREDGE, AICP
 SENIOR PLANNER
 PLANNING & ZONING DIVISION
 PHONE: (561)-822-1443
 EMAIL: [email protected]
  

Review Stop Z ZONING
Rev No 1 Status F Date 2014-01-02 Cont ID  
Sent By dkittred Date 2014-01-02 Time 15:47 Rev Time 0.00
Received By dkittred Date 2014-01-02 Time 15:02 Sent To  
Notes
2014-01-02 15:46:55PLANNING AND ZONING COMMENTS: ***FAILED***
  
 1/2/2014
  
 1. SITE IS PENDING CITY COMMISSION APPROVAL OF A MAJOR
 PD AMENDMENT (TENTATIVE 1/6/14 - 1ST READING; 1/21/14 -
 2ND READING) TO ALLOW FOR A DRIVE-THRU RESTAURANT USE
 AND INCREASE THE BUILDING SIZE BY NO GREATER THAN 400
 SQUARE FEET. PLEASE VERIFY PROPOSED ADDITIONS
 (DRIVE-THRU WINDOW AREA AND COOLER/FREEZER) ARE NO
 GREATER THAN 400 SQUARE FEET.
  
 2. SITE IS PENDING SITE PLAN APPROVAL FOR BUILDING
 EXPANSION AND DRIVE-THRU. SITE PLAN REVIEW IS CURRENTLY
 IN PROGRESS.
  
 3. PLANNING DEPT. APPROVAL OF THE BUILDING PERMIT IS
 PENDING APPROVAL OF ITEMS 1 AND 2. BASED ON THE OUTCOME
 OF ITEMS 1 AND 2, ADDITIONAL COMMENTS ON THE PLANS MAY
 BE GENERATED.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT:
  
 DANIELLE J. KITTREDGE, AICP
 SENIOR PLANNER
 PLANNING & ZONING DIVISION
 PHONE: (561)-822-1443
 EMAIL: [email protected]
  
2014-01-02 11:56:461/2/14


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved