Plan Review Details - Permit 13121023
Plan Review Stops For Permit 13121023
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2014-02-13 Cont ID  
Sent By jgomez Date 2014-02-13 Time 15:49 Rev Time 0.00
Received By jgomez Date 2014-02-13 Time 14:41 Sent To  
Notes
2014-02-13 16:43:28RESIDENTIAL (R3) ADDITION/ALTERATION, BUILDING REVIEW
 COMMENTS.
 CODE: 2010 FBC.
  
 1- A) PROVIDE COMPLETE CONSTRUCTION DOCUMENTS DRAWN TO
 SCALE AND WITH ALL THE DIMENSIONS AS REQUIRED BY SEC.
 107.2.1 CITY AMENDMENTS TO FBC. CLEARLY SPECIFY
 LOCATION OF PROPOSED WORK.
  
 B) PERSON RESPONSIBLE FOR THE DESIGN NEEDS TO PROVIDE
 NAME AND SIGNATURE AS REQUIRED BY SEC. 107.2.1 CITY
 AMENDMENTS.
  
 C) CONSTRUCTION DOCUMENTS TO SPECIFY CURRENT CODE 2010
 FBC-RESIDENTIAL, AND PROVIDE ALL THE DESIGN CRITERIA
 INCLUDING WIND LOADS, AND OPENINGS DESIGN PRESSURES AS
 REQUIRED BY SEC. R301 OF 2010 FBC-RESIDENTIAL.
  
 2- SPECIFY BATHROOM VENTILATION AS REQUIRED BY SEC.
 R303.3 OF 2010 FBC-RESIDENTIAL.
  
 3- ACCORDING TO PROPERTY APPRAISER THE OWNER LIVES AT
 4122 ONEGA CIRCLE. WPB, FL 33409. AND, CLAIMS HOMESTEAD
 EXEMPTION ON THIS ADDRESS ALSO. IT LOOKS LIKE OWNER
 CAN'T QUALIFY AS AN OWNER/BUILDER UNDER FLORIDA STATUTE
 SEC. 489.103. NEED LICENSED CONTRACTOR TO APPLY FOR THE
 REQUIRED PERMITS.
  
 4- VALUATION DECLARED IN THE PERMIT APPLICATION IS TOO
 LOW. AS REQUIRED BY SEC. 109.3 CITY AMENDMENTS
 VALUATION TO INCLUDE ALL LABOR, MATERIALS, OVERHEAD AND
 PROFIT AND ALL DESIGN PROFESSIONAL FEES. REVISE
 VALUATION AS REQUIRED TO INCLUDE ALL SCOPE OF WORK.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561)805-6712
2014-02-12 11:29:32SENT TO JGOMEZ TO COMPLETE REVIEW AND PROCESS.

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2014-02-12 Cont ID  
Sent By skennedy Date 2014-02-12 Time 11:22 Rev Time 0.00
Received By skennedy Date 2014-02-12 Time 11:20 Sent To  
Notes
2014-02-12 11:28:21FBC- 107.3.5.3 ? PROVIDE AN ELECTRICAL PLAN TO
 DEMONSTRATE PROPOSED OR EXISTING ELECTRICAL. INCLUDE
 LOCATION AND TYPE OF SWITCHES, AND OUTLETS INDICATE
 CIRCUITS ON FLOOR PLAN AND MAKE REFERENCE TO PANEL
 INFORMATION AND OVERCURRENT PROTECTION (BREAKER SIZE,
 WIRE SIZE, GFI PROTECTION)

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2014-02-14 Cont ID  
Sent By jgomez Date 2014-02-14 Time 08:58 Rev Time 0.00
Received By jgomez Date 2013-12-26 Time 16:19 Sent To  
Notes
2013-12-26 16:20:01SENT TO R14 SHELF FOR REVIEW. JG.

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status N Date 2014-02-14 Cont ID  
Sent By jgomez Date 2014-02-13 Time 16:44 Rev Time 0.00
Received By jgomez Date 2014-02-13 Time 16:43 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2014-02-13 Cont ID  
Sent By jgomez Date 2014-02-13 Time 16:59 Rev Time 0.00
Received By jgomez Date 2014-02-13 Time 16:59 Sent To  
Notes
2014-02-13 17:05:24RESIDENTIAL (R3) ADDITION/ALTERATION PLUMBING REVIEW
 COMMENTS.
 CODE: 2010 FBC
  
 1- PROVIDE PLUMBING RISER DIAGRAM AS REQUIRED BY SEC.
 107.3.5.3 OF CITY AMENDMENTS TO FBC.
  
 2- PROVIDE PLANS SHOWING ALL DIMENSIONS TO VERIFY
 COMPLIANCE WITH DIMENSIONS AND CLEARANCES REQUIRED BY
 SEC. P2705 AND SEC. P2708 OF 2010 FBC-RESIDENTIAL.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561)805-6712

Review Stop Z ZONING
Rev No 1 Status F Date 2014-02-14 Cont ID  
Sent By sgraham Date 2014-02-14 Time 08:39 Rev Time 0.00
Received By sgraham Date 2014-02-14 Time 08:38 Sent To  
Notes
2014-02-14 08:42:372/14/14 ZONING FAILED.
 1. NEED A SURVEY OF THE PROPERTY.
 2. PLEASE INDICATE IF THE UTILITY ROOM IS EXISTING,IF
 NOT PLEASE SHOW THE ADDITION ON THE SITE.