| Plan Review Stops For Permit 13120969 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2014-03-20 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2014-03-20 |
Time |
16:26 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2014-03-20 |
Time |
16:26 |
Sent To |
|
|
| Notes |
| 2014-03-20 16:27:03 | INSWING DOORS OK PER RB (OUTSWING DOORS WOULD ENCROACH | | | PUBLIC WAY) | | | PER TENANT (CLUB MANAGEMENT), DOORS WILL REMAIN OPEN | | | DURING BUSINESS HOURS | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2014-02-24 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2014-02-24 |
Time |
16:12 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2014-02-24 |
Time |
16:12 |
Sent To |
|
|
| Notes |
| 2014-02-24 16:15:50 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 | | | [email protected] | | | | | | FBC FLORIDA BUILDING CODE 2010 | | | | | | 1. THE DOORS PROPOSED DO NOT INCLUDE PANIC DEVICES (SEE | | | PREVIOUS LIST FOR CODE REFERENCES). THE PANIC DEVICE | | | PROPOSED IS NOT LISTED (SEE FBC 1008.1.10.1) AND | | | RETROFIT OF THE PROPOSED PANIC DEVICE ON TO THE | | | PROPOSED DOORS WOULD VIOLATE THE PRODUCT APPROVAL (WIND | | | RESISTANCE REQUIREMENTS AND TESTING, FBC 1609). | | | | | | THIS HAS BEEN CONFIRMED WITH THE MANUFACTURER OF THE | | | DOOR. PLEASE SELECT A DOOR WHICH HAS BEEN TESTED WITH A | | | UL LISTED PANIC DEVICE. | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2014-02-10 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2014-02-10 |
Time |
12:55 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2014-02-10 |
Time |
12:55 |
Sent To |
|
|
| Notes |
| 2014-02-10 12:57:01 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 | | | [email protected] | | | | | | FBC FLORIDA BUILDING CODE 2010 | | | | | | 1. PROVIDE FLORIDA STATE OR PRODUCT APPROVAL FOR THE | | | SLIDING GLASS DOORS FAC9N-3. ON THE PRODUCT APPROVAL | | | INDICATE PROPOSED THRESHOLD, FBC 1003.5, FBC 2010 | | | ACCESSIBILITY 404.25. | | | | | | 2ND REVIEW - WHEN RESUBMITTING, PLEASE PROVIDE THE | | | FLORIDA STATE PRODUCT APPROVAL COVER SHEET. THIS SHOWS | | | THE APPROVAL NUMBER AND STATUS. THIS MAY BE AVAILABLE | | | AT WWW.FLORIDABUILDING.ORG. | | | | | | 2. SEE FBC 1008.1, DOORS PROVIDED IN NUMBERS GREATER | | | THAN REQUIRED BY THIS CODE SHALL MEET THE REQUIREMENTS | | | OF FBC 1008; THEREFORE THE REQUIREMENTS OF 1008.1.4.3 | | | APPLY (SLIDING DOORS). SEE ALSO 1008.1.10 REGARDING | | | PANIC DEVICES (ENTRY DOOR). | | | | | | 2ND REVIEW, THE THRESHOLD APPEARS TOO TALL TO MEET | | | ACCESSIBILITY REQUIREMENTS. | | | | | | PANIC DEVICES REQUIRED; NOT AN OPTION FOR THE DOORS | | | PROPOSED. | | | | | | 3. OK |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2014-01-10 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2014-01-10 |
Time |
16:58 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2014-01-10 |
Time |
16:58 |
Sent To |
|
|
| Notes |
| 2014-01-10 17:07:37 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 | | | [email protected] | | | | | | FBC FLORIDA BUILDING CODE 2010 | | | | | | 1. PROVIDE FLORIDA STATE OR PRODUCT APPROVAL FOR THE | | | SLIDING GLASS DOORS FAC9N-3. ON THE PRODUCT APPROVAL | | | INDICATE PROPOSED THRESHOLD, FBC 1003.5, FBC 2010 | | | ACCESSIBILITY 404.25. | | | | | | 2. SEE FBC 1008.1, DOORS PROVIDED IN NUMBERS GREATER | | | THAN REQUIRED BY THIS CODE SHALL MEET THE REQUIREMENTS | | | OF FBC 1008; THEREFORE THE REQUIREMENTS OF 1008.1.4.3 | | | APPLY (SLIDING DOORS). SEE ALSO 1008.1.10 REGARDING | | | PANIC DEVICES (ENTRY DOOR). | | | | | | 3. REVISE PLAN TO INCLUDE COMPLIANCE METHOD, FBC 2010 | | | EXISTING BUILDING 101.5. SEE ALSO EXCEPTION. PLEASE | | | FEEL FREE TO CONTACT ME IF YOU WISH TO DISCUSS. | | | | | | | | 2014-01-06 09:27:34 | REQUEST FOR EXPEDITE. PLAN GIVEN TO SH. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
4 |
Status |
P |
Date |
2014-03-20 |
|
|
Cont ID |
|
| Sent By |
rferguso |
Date |
2014-03-20 |
Time |
11:50 |
Rev Time |
0.00 |
| Received By |
rferguso |
Date |
2014-03-20 |
Time |
11:50 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
F |
Date |
2014-03-20 |
|
|
Cont ID |
|
| Sent By |
rferguso |
Date |
2014-02-20 |
Time |
16:05 |
Rev Time |
0.00 |
| Received By |
rferguso |
Date |
2014-02-20 |
Time |
16:05 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
2014-02-10 |
|
|
Cont ID |
|
| Sent By |
rferguso |
Date |
2014-02-10 |
Time |
15:51 |
Rev Time |
0.00 |
| Received By |
rferguso |
Date |
2014-02-10 |
Time |
15:51 |
Sent To |
|
|
| Notes |
| 2014-02-10 15:54:22 | SEE BUILDING PLAN REVIEW COMMENTS. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2014-01-13 |
|
|
Cont ID |
|
| Sent By |
rferguso |
Date |
2014-01-13 |
Time |
13:57 |
Rev Time |
0.00 |
| Received By |
rferguso |
Date |
2014-01-13 |
Time |
13:57 |
Sent To |
|
|
| Notes |
| 2014-01-13 14:03:11 | 114 SOUTH NARCISSUS STREET | | | PERMIT #13120968 | | | | | | WEST PALM BEACH FIRE RESCUE PLAN REVIEW COMMENTS. | | | | | | SEE BUILDING PLAN REVIEW COMMENTS. | | | | | | RONALD E. FERGUSON, ASSISTANT FIRE MARSHAL | | | BUREAU OF FIRE PREVENTION | | | WEST PALM BEACH FIRE RESCUE | | | PHONE (561)804-4700 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2014-03-20 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2014-03-20 |
Time |
16:27 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2014-03-17 |
Time |
16:44 |
Sent To |
|
|
| Notes |
| 2014-03-20 16:13:38 | TO ANA APONTE DESK | | | | | 2014-03-20 16:13:17 | TO FIRE | | | | | 2014-03-17 16:45:14 | 3/17/2014 INCOMING SENT TO S HILL DESK. JW |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2014-02-24 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2014-02-24 |
Time |
16:15 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2014-02-14 |
Time |
07:09 |
Sent To |
|
|
| Notes |
| 2014-02-18 07:09:54 | SENT TO FIRE BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2014-02-10 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2014-02-10 |
Time |
17:03 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2014-02-07 |
Time |
15:38 |
Sent To |
|
|
| Notes |
| 2014-02-10 12:57:15 | TO RON FERGUSON | | | | | 2014-02-07 15:38:20 | TO SH DESK | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2014-01-13 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2014-01-13 |
Time |
17:44 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2013-12-26 |
Time |
10:32 |
Sent To |
|
|
| Notes |
| 2014-01-10 17:23:15 | 1/10 TO FIRE | | | | | 2013-12-26 10:32:50 | TO MISC 1 | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2014-03-20 |
|
|
Cont ID |
|
| Sent By |
aaponte |
Date |
2014-03-20 |
Time |
16:22 |
Rev Time |
0.00 |
| Received By |
aaponte |
Date |
2014-03-20 |
Time |
16:22 |
Sent To |
|
|
| Notes |
|
|