| Plan Review Stops For Permit 13120916 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2014-01-23 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2014-01-23 |
Time |
11:12 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-01-07 |
Time |
10:05 |
Sent To |
|
|
| Notes |
| 2014-01-23 11:12:51 | | | | BUILDING PLAN REVIEW | | | PERMIT: 13120916 | | | ADD: 1815 PALM BEACH LAKES SHELL BLDG "E" | | | CONT: EMJ | | | TEL: (561 | | | | | | 2010 FLORIDA BUILDING CODE W | | | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | | | 1ST REVIEW | | | DATE: THURSDAY JAN. 23/ 2014 | | | ACTION: BUILDING PROVISO | | | | | | 1) SHEET A141 ROOF PLAN INDICATES ZONE # 1 TO BE | | | MECHANICALLY FASTENED, NOTE ON PLAN ZONES 2 & 3 THE | | | ROOFING IS TO BE FULLY ADHERED SINGLE PLY TPO. | | | | | | NOA 12-0514.04 FIRESTONE 1-30 PAGES TPO OVER STEEL DECK | | | PAGE 12 HIGHLIGHTED SINGLE PLY TPO, STEEL INSULATED | | | DECK 22 GAUGE/ 6'-0" SPACING | | | ISO 95+GL MIN 2" THICK MAXIMUM DESIGN FOR MECH FASTENED | | | -75 PSI | | | | | | NO SHEETS HIGHLIGHTED IN THE NOA FOR FULLY ADHERED FOR | | | ZONES 2 & 3, ADDITIONAL INFORMATION IS REQUIRED. 2010 | | | WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING | | | CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | | 107.2.1.3. | | | | | | ======================================================= | | | ====================== | | | | | | NOA- 13-0603.19 GAF ENERGY GAURD |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2014-01-30 |
|
|
Cont ID |
|
| Sent By |
dharvey |
Date |
2014-01-30 |
Time |
12:03 |
Rev Time |
0.00 |
| Received By |
dharvey |
Date |
2014-01-30 |
Time |
10:23 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
P |
Date |
2014-01-29 |
|
|
Cont ID |
|
| Sent By |
mgonzale |
Date |
2014-01-29 |
Time |
|
Rev Time |
1.00 |
| Received By |
mgonzale |
Date |
2014-01-29 |
Time |
|
Sent To |
Z |
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2013-12-30 |
|
|
Cont ID |
|
| Sent By |
scaldero |
Date |
2013-12-30 |
Time |
10:19 |
Rev Time |
0.00 |
| Received By |
scaldero |
Date |
2013-12-30 |
Time |
10:19 |
Sent To |
|
|
| Notes |
| 2013-12-30 10:22:37 | PERMIT #13120916 | | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | | | FIRE PROTECTION SYSTEMS SHALL REMAIN ACTIVE DURING | | | DEMOLITION AND RENOVATION ACTIVITIES. IN THE EVENT A | | | FIRE PROTECTION SYSTEM IS OUT OF SERVICE FOR MORE THAN | | | 4-HOURS IN A 24-HOUR PERIOD, THE BUILDING SHALL BE | | | PLACED UNDER A FIRE WATCH. ALL FIRE WATCH REQUESTS MUST | | | BE SUBMITTED BY EMAIL ([email protected]) | | | ([email protected]) OR IN WRITING (FAX: 561-804-4774) AND | | | APPROVED BY THE OFFICE OF THE FIRE MARSHAL LOCATED AT | | | 500 NORTH DIXIE HIGHWAY. | | | | | | ENTRY DOORS: THUMB-TURN LOCK TO BE EQUIPPED WITH A | | | LOCK/UNLOCK INDICATOR. | | | | | | EACH FIRE BARRIER SHALL BE PERMANENTLY IDENTIFIED WITH | | | SIGNS OR STENCILING READING FIRE BARRIER-PROTECT ALL | | | OPENINGS. CHARACTERS SHALL BE AT LEAST 4-INCHES IN | | | HEIGHT AND HALF-INCH IN WIDTH. IDENTIFICATION SHALL BE | | | SPACED NOT MORE THAN 15 FEET ON CENTER. | | | | | | ALL CONSTRUCTION AND DEMOLITION WORK SHALL CONFORM TO | | | THE REQUIREMENTS OF NFPA 241. TRASH AND CONSTRUCTION | | | DEBRIS SHALL BE REMOVED FROM THE SITE DAILY. SMOKING | | | SHALL BE PROHIBITED EXCEPT IN DESIGNATED EXTERIOR | | | AREAS. ALL OTHER DEMOLITION OR CONSTRUCTION AREAS SHALL | | | HAVE "NO SMOKING" SIGNS POSTED. WHERE SMOKING IS | | | PERMITTED, SAFE RECEPTACLES FOR SMOKING MATERIALS SHALL | | | BE PROVIDED. | | | | | | SEPARATE PLANS AND PERMITS ARE REQUIRED FOR THE | | | INSTALLATION OR MODIFICATION OF THE FIRE SPRINKLER | | | SYSTEM AND/OR FIRE ALARM SYSTEM. | | | | | | SUE ELLEN CALDERON | | | FIRE INSPECTOR & INVESTIGATOR | | | OFFICE OF THE FIRE MARSHAL | | | WEST PALM BEACH FIRE RESCUE | | | [email protected] | | | (561) 804-4751 | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
N |
Date |
2014-02-26 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2014-02-26 |
Time |
12:26 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-02-26 |
Time |
12:06 |
Sent To |
|
|
| Notes |
| 2014-02-26 12:26:20 | FUEL GAS PLAN REVIEW | | | PERMIT: 13120916 | | | ADDRESS: 1815 PALM BEACH LAKES BLDG "SHELL" | | | CONT: EMJ | | | TEL: (423) 855-6857 | | | | | | 2010 FLORIDA BUILDING CODE W | | | * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS | | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | | | 2ND REVIEW | | | DATE: WED.26/ 2014 | | | ACTION: GAS PROVISO | | | | | | 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING | | | CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | | | | | 1) A SEPARATE GAS PERMIT IS REQUIRED, IT IS NOT COVERED | | | UNDER THE PLUMBING PERMIT OR PLAN REVIEW, THIS IS FOR | | | THE SHELL ONLY! | | | | | | 2) 2010 FUEL GAS SECTION: | | | 404.4 UNDERGROUND PENETRATIONS PROHIBITED. | | | GAS PIPING SHALL NOT PENETRATE BUILDING FOUNDATION | | | WALLS AT ANY POINT BELOW GRADE. GAS PIPING SHALL ENTER | | | AND EXIT A BUILDING AT A POINT ABOVE GRADE AND THE | | | ANNULAR SPACE BETWEEN THE PIPE AND THE WALL SHALL BE | | | SEALED. | | | 404.6 PIPING IN SOLID FLOORS. | | | PIPING IN SOLID FLOORS SHALL BE LAID IN CHANNELS IN THE | | | FLOOR AND COVERED IN A MANNER THAT WILL ALLOW ACCESS TO | | | THE PIPING WITH A MINIMUM AMOUNT OF DAMAGE TO THE | | | BUILDING. WHERE SUCH PIPING IS SUBJECT TO EXPOSURE TO | | | EXCESSIVE MOISTURE OR CORROSIVE SUBSTANCES, THE PIPING | | | SHALL BE PROTECTED IN AN APPROVED MANNER. AS AN | | | ALTERNATIVE TO INSTALLATION IN CHANNELS, THE PIPING | | | SHALL BE INSTALLED IN A CONDUIT OF SCHEDULE 40 STEEL, | | | WROUGHT IRON, PVC OR ABS PIPE IN ACCORDANCE WITH | | | SECTION 404.6.1 OR 404.6.2. | | | | | | 3) NOTE # 10 INDICATES THE GAS PIPE IS TO BE SIZED FOR | | | FUTURE TENANT CONNECTION. VERIFY TENANT GAS LOAD DEMAND | | | & PRESSURE REQUIREMENTS WITH TENANT IMPROVEMENT PLAN | | | PROR TO THE INSTALATION OF GAS LINE. GAS IS TO BE SIZED | | | TO THE MAXIMUM DEMAND 402.2.PROVIDE SIZING METHOD AND | | | TABLES FOR SIZING OF PIPE AND DEVELOPED LENGTH. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | | | | | | | | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2014-01-23 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2014-01-23 |
Time |
11:29 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-01-23 |
Time |
11:29 |
Sent To |
|
|
| Notes |
| 2014-01-23 11:29:28 | FUEL GAS PLAN REVIEW | | | PERMIT: 13120916 | | | ADDRESS: 1815 PALM BEACH LAKES BLDG "SHELL" | | | CONT: EMJ | | | TEL: (423) 855-6857 | | | | | | 2010 FLORIDA BUILDING CODE W | | | * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS | | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | | | 1ST REVIEW | | | DATE: THURS. JAN. 23/ 2014 | | | ACTION: DENIED | | | | | | 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING | | | CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | | | | | 1) A SEPARATE GAS PERMIT IS REQUIRED, IT IS NOT COVERED | | | UNDER THE PLUMBING PERMIT OR PLAN REVIEW, THIS IS FOR | | | THE FOUNDATION ONLY. | | | | | | 2) SHEET P101 NOTE # 9 INDICTES UNDERGROUND GAS LINE, | | | METER AND REGULATOR SHALL BE PROVIDED AND INSTALLED BY | | | THE GAS UTILITY COMPANY. NOTE # 10 GAS CAPPED FOR | | | FUTURE TENANT CONNECTION. VERIFY TENANT GAS LOAD DEMAND | | | & PRESSURE REQUIREMENTS WITH TENANT IMPROVEMENT PLAN | | | PROR TO THE INSTALATION OF GAS LINE. | | | | | | 2A) IT IS NOT CLEAR AS TO WHERE FLORIDA GAS UTIULITIES | | | METER IS TO BE SET. IT APPEARS THAT THE GAS LINES ARE | | | TO BE BENEATH THE SLAB. PLEASE REVIEW 2010 FBC-GAS | | | SECTIONS : | | | 404.4 UNGROUND PENETRATIONS PROHIBITED, AND 404.6 | | | PIPING IN SOLID FLOORS. | | | | | | 2B) NOTE # 10 INDICATES THE GAS PIPE IS TO BE SIZED FOR | | | FUTURE TENANT CONNECTION. VERIFY TENANT GAS LOAD DEMAND | | | & PRESSURE REQUIREMENTS WITH TENANT IMPROVEMENT PLAN | | | PROR TO THE INSTALATION OF GAS LINE. GAS IS TO BE SIZED | | | TO THE MAXIMUM DEMAND 402.2.PROVIDE SIZING METHOD AND | | | TABLES FOR SIZING OF PIPE AND DEVELOPED LENGTH. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | | | | | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2014-03-13 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2014-03-10 |
Time |
08:27 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2014-02-24 |
Time |
09:59 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2014-02-06 |
Time |
|
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2013-12-26 |
Time |
14:01 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
N |
Date |
2014-02-26 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2014-02-26 |
Time |
14:04 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-02-26 |
Time |
14:04 |
Sent To |
|
|
| Notes |
| 2014-02-26 14:05:58 | IMPACT FEE CREDITS STILL CONTINUES, RECEIPTS FROM PALM | | | BEACH COUNTY NO FEES DUE. JW |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2014-01-23 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2014-01-23 |
Time |
11:14 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-01-23 |
Time |
11:14 |
Sent To |
|
|
| Notes |
| 2014-01-23 11:14:50 | BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL | | | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND | | | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT | | | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2014-01-04 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2014-01-04 |
Time |
11:55 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2014-01-04 |
Time |
11:55 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2014-01-25 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2014-01-23 |
Time |
11:47 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-01-23 |
Time |
11:29 |
Sent To |
|
|
| Notes |
| 2014-01-23 11:56:33 | PLUMBING PLAN REVIEW | | | PERMIT: 13120916 | | | ADD: 1703 PALM BEACH LAKES / SHELL BUILDING-E | | | CONT: EMJ | | | TEL: (561) 373-3902 | | | CONTACT: KARI | | | | | | 2010 FLORIDA BUILDING CODE W | | | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | | | 1ST REVIEW | | | DATE: THURSDAY JAN. 23/ 2014 | | | ACTION: PLUMBING APPROVED WITH EXCEPTION! | | | THIS PLAN HAS BEEN APPROVED PROVISIONALLY. FAILURE TO | | | CORRECT THE LISTED DEFICIENCIES IN THIS PLAN PRIOR TO | | | INSPECTION WILL RESULT IN FAILED INSPECTION(S) AND THE | | | ASSESSMENT OF RE-INSPECTION FEE(S). REVISIONS REQUIRE | | | ADDITIONAL REVIEWS WITH ASSOCIATED FEES. | | | | | | 2010 CHAPTER 1 ADMINISTRATIVE CODE 105.13. | | | SPECIAL PHASED PERMIT APPROVAL | | | AFTER SUBMITTAL OF THE APPROPRIATE CONSTRUCTION | | | DOCUMENTS, THE BUILDING OFFICIAL IS AUTHORIZED TO ISSUE | | | A PERMIT FOR THE CONSTRUCTION OF SHELL OR ANY OTHER | | | PART OF A BUILDING OR STRUCTURE BEFORE THE CONSTRUCTION | | | DOCUMENTS FOR THE WHOLE BUILDING OR STRUCTURE HAVE BEEN | | | SUBMITTED. THE HOLDER OF SUCH PERMIT FOR THE SHELL OR | | | OTHER PARTS OF A BUILDING OR STRUCTURE SHALL PROCEED AT | | | THE HOLDER'S OWN RISK WITH THE BUILDING OPERATION AND | | | WITHOUT ASSURANCE THAT A PERMIT FOR THE ENTIRE | | | STRUCTURE WILL BE GRANTED. CORRECTIONS MAY BE REQUIRED | | | TO MEET THE REQUIREMENTS OF THE TECHNICAL CODES. THIS | | | PROVISION IS ONLY FOR THE FLORIDA BUILDING CODE, ALL | | | OTHER AGENCY APPROVALS NECESSARY FOR CONSTRUCTION MUST | | | BE SECURED PRIOR TO THIS PROVISION BEING APPLIED. | | | | | | SHEET P101 PLUMBING NOTES INDICATE THE EXTENT OF THIS | | | PERMIT FOR THE INTERIOR PLUMBING: | | | NOTE # 3 TO SUPPLY CW PIPING IN CEILING JOIST SPACE | | | VALVE AND CAP FOR FUURE TENANT CONNECTION. | | | NOTE # 4 TO PROVIDE 4 INCH SANITARY STUBBED UP IN AREA | | | OF SLAB LEAVE OUT AND CAPPED FOR FUTURE TENANT | | | CONNECTION. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2014-03-14 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2014-03-14 |
Time |
10:07 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2014-03-14 |
Time |
10:07 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2014-03-11 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2014-03-10 |
Time |
23:29 |
Rev Time |
0.75 |
| Received By |
eschneid |
Date |
2014-03-10 |
Time |
23:29 |
Sent To |
|
|
| Notes |
| 2014-03-11 00:08:50 | PASSED | | | | | | 1) PRIOR TO C.O., A REVISED SHEET A100 SHALL BE | | | SUBMITTED SHOWING THE DRIVE THROUGH CONFIGURATION AND | | | FEATURES AS APPROVED BY THE MARCH 10, 2014 MINOR | | | AMENDMENT APPROVAL LETTER. | | | | | | 2) SIGNS AND AWNINGS REQUIRE SEPARATE PERMITS. | | | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1446. | | | | | | | | 2014-03-03 14:58:00 | 3/3/14 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2014-02-06 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2014-02-06 |
Time |
13:50 |
Rev Time |
2.00 |
| Received By |
eschneid |
Date |
2014-02-06 |
Time |
13:50 |
Sent To |
|
|
| Notes |
| 2014-02-06 15:33:06 | FAILED | | | | | | 1) PROVIDE A SITE PLAN SHOWING THE DIMENSION FROM THE | | | NORTHEAST CORNER OF THE BUILDING TO THE PALM BEACH | | | LAKES BOULEVARD PROPERTY LINE. | | | | | | 2) SHOW CORRECT BICYCLE RACK AND PAD. | | | | | | 3) THE DRIVE THRU CONFIGURATION IS NOT CORRECTLY SHOWN | | | BASED ON THE RECENT DISCUSSIONS WITH URBAN DESIGN | | | KILDAY STUDIOS. | | | | | | 4) THE DUMPSTER ENCLOSURE, MENU BOARDS, SPEAKER POST, | | | GUARDRAIL, BICYCLE RACK, ETC. REQUIRE SEPARATE PERMITS, | | | WITH PLANS. | | | | | | 5) THE PARKING LOT, TO INCLUDE STRIPING, REQUIRES A | | | SEPARATE PERMIT, WITH PLANS. | | | | | | 6) PLEASE PROVIDE VERIFICATION THAT THIS OUTPARCEL IS | | | INCLUDED IN THE CONSTRUCTION SITE SECURITY PLAN. PLEASE | | | CONTACT OFFICER KELLY CARSILLO. | | | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1446. | | | | | 2014-01-02 11:56:01 | 1/2/14 |
|
|